warning - hvacdirect.com...this appliance may be installed in an aftermarket, permanently located,...

64
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. WARNING If not installed, operated and maintained in accordance with the manufacturer’s instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness. WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death or property damage. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Leave the building immediately. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer, service agency or the gas supplier. HOT GLASS DO NOT TOUCH NEVER WILL CAUSE BURNS. GLASS UNTIL COOLED. ALLOW CHILDREN TO TOUCH GLASS. WARNING A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. NOTICE: Barrier required. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. DIRECT VENT ZERO CLEARANCE GAS FIREPLACE HEATER MODEL SERIES: MULTIFUNCTION REMOTE (MF) DVLL72BP90(N,P)-1 UL FILE NO. MH30033 GAS-FIRED INSTALLATION INSTRUCTIONS 38217

Upload: others

Post on 07-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

WARNINGIf not installed, operated and maintained in accordance with the manufacturer’s instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness.

WARNINGFIRE OR EXPLOSION HAZARDFailure to follow safety warnings exactly could result in serious injury, death or property damage.

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electrical switch; do

not use any phone in your building.• Leave the building immediately.• Immediately call your gas supplier

from a neighbor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

— Installation and service must be performed by a qualified installer, service agency or the gas supplier.

HOT GLASS

DO NOT TOUCH

NEVER

WILLCAUSE BURNS.

GLASSUNTIL COOLED.

ALLOW CHILDRENTO TOUCH GLASS.

WARNING

A barrier designed to reduce the risk of burns from thehot viewing glass is provided with this appliance and shallbe installed for the protection of children and other at-riskindividuals.

NOTICE: Barrier required.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

DIRECT VENT ZERO CLEARANCE

GAS FIREPLACE HEATERMODEL SERIES:

MULTIFUNCTION REMOTE (MF)

DVLL72BP90(N,P)-1UL FILE NO. MH30033

GAS-FIRED

INSTALLATION INSTRUCTIONS 38217

Page 2: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 2

BEFORE YOU STARTSAMPLE WARNINGS AND DEFINITIONS:

DANGERIndicates a hazardous situation which, if not avoided, will result in death or serious injury.

WARNINGIndicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTIONIndicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Addresses practices not related to personal injury.

1. Read the safety information on pages 57 - 58.2. If located in the Commonwealth of Massachusetts, please

note the special requirements on page 59.3. Areyougoingtoinstallablowerintothefireplace?See

pages 8 - 10.4. Whereareyougoingtoinstallthefireplace?Seepage13.5. Frametheopening.Seepage20.6. Installthegaslines.Seepages16-17.7. Installthewiring.Seepages18-19.8. Installtheventing.Seepages26-35.9. Installthefireplace.Seepages20-25.10. Installtheremotesystem.Seepages40-46.11. Linerrequirements.Seepage38.12. Installtheglassmedia.Seepage39.13. Lightthefireplaceandtroubleshoot.Seepage47.14. Showthehomeownerhowtooperatethefireplace.15. Showthehomeownerhowtodothebasicmaintenance.

UNPACKING THE FIREPLACE1. Cut binding straps and shrink wrap.2. Remove top board and corner posts.3. Liftfireplaceoffofthepallet.4. Remove non-combustible boards from pallet and set aside.5. Verifythatthefireplaceandcomponentshavenotbeen

damaged during shipping.6. Setfireplaceinalocationneartoitsfinalinstallationlocation.

INSTALLATION CONSIDERATIONS - FIREPLACE INSTALLATION GUIDELINESWhenplanningafireplaceinstallation,it’snecessarytodetermine:• Gassupplypiping(rightsideentrance).• Electricalsupplyrequirements

(120V,60Hz,1Amp)(rightsideentrance)• DVLL72BPmodelsincludethefactoryinstalledLEDLight

assembly. • Properopeningsizeofframingrequiredforinstallationof

thefireplace.Theframingofthefireplacewilldeterminehowthefireplacefinishingmaterialswillbeapplied.Refertotheinstallation information on pages 20 to 23.

• Theblowerkitiseasiertoinstallatthetimeoffireplaceinstallations.Seeblowerinstallationsectiononpages8to10.

Inplanningtheinstallationforthefireplace,determinewherethefireplaceistobeinstalledandwhetheroptionalaccessoriesaredesired.Gassupplypipingshouldalsobeplannedatthistime.Thefireplacecanbemountedonanyofthesesurfaces:1. Aflathardcombustibleornon-combustiblesurface.2. A raised platform of combustible or non-combustible

material.

Ifthefireplaceisinstalleddirectlyoncarpeting,tileorothercombustiblematerialotherthanwoodflooring,itshouldbeinstalled on a metal or wood panel extending the full width and depthofthefireplace.Thefireplaceisdesignedtobeinstalledinazero-clearanceenclosure.Thismeansthatcombustiblematerialsmustbelocatedatclearancesspecifiedorprovidedbystandoffsorspacersattachedtothefireplace.Combustible materials can come in contact with the nailing flangesprovided.

HOMEOWNER REFERENCE INFORMATIONRecordthefollowinginformationaboutyourfireplace.

Model: ____________________________________ Datepurchased/installed: ____________________

SerialNumber: _____________________________ Locationonfireplace: _______________________

Dealership: ________________________________ DealerPhone: ____________________________

Notes: _______________________________________________________________________________

_____________________________________________________________________________________

Page 3: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 3

CARTON CONTENTS & HARDWARE PACK

Items not shown to scale.

INDEX NUMBER DESCRIPTION PART

NO.QUANTITY SUPPLIED

1 DoorRemovalTool(attachedtofireplace) 35978 1

2 Product Registration Card 29804 13 AA Battery B076529 44 AAA Battery R10600 3

5 WallThimbleSpacer(attachedtofireplace) 33331 1

6 Mounting Bracket 36827 17 RemoteTransmitter R11550 18 Junction Box Cover R3491 19 DuplexReceptacle R3492 1

10 Flue Restrictor Assembly 34054 111 Remote Receiver R11584 112 Bushing,5/8DIA R1536 113 Wall Plate R12296 114 Wall Mounted Control Box R12295 115 ButtonSwitch R11921 2

16 WireHarnessModuleToInterface R11552 1

A #10x1/2Screw R2737 22B #8x1Self-DrillingScrew* R11509 15C NailingFlange 28450 4

D#4x3/8PhillipsPanHeadScrew

R12300 4

*Foruseinmountingnon-combustibleboardtostandoffs.SeePartsListsonpages50fororderingreplacementparts.Donotorderbatteries,bolts,screws,washersornuts.Theyarestandard hardware items and can be purchased at any local hardware store.

1615

1413

1211

109

87

65

43

21 A

B

C

D

1” PHILLIPS SELF DRILLING SCREW

#10 X ½” HEX HEAD SCREW

NAILING FLANGES

3/8”

#10x1/2”HEXHEADSCREW

1”PHILLIPSSELFDRILLINGSCREW

NAILINGFLANGES

#4x3/8”STAINLESSPHILLIPSHEADSCREW

Page 4: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 4

TABLE OF CONTENTS

BeforeYouStart.............................................................................................................................2HomeownerReferenceInformation ...............................................................................................2CartonContentsandHardwarePack ............................................................................................3Introduction ....................................................................................................................................5Specifications.................................................................................................................................6Accessories ...................................................................................................................................7FBB20 Blower Installation...................................................................................................... 8 - 10FireplaceDimensions ..................................................................................................................11Clearances...................................................................................................................................12Optional Fireplace Locations .......................................................................................................13VentTerminationClearances ............................................................................................... 14 - 15GasSupply .......................................................................................................................... 16 - 17ElectricalConnections ......................................................................................................... 18 - 19Installation............................................................................................................................ 20 - 25VentSystemIdentification ...........................................................................................................26VentingFireplace-Top ........................................................................................................ 27 - 29TopVent-HorizontalTermination ................................................................................................30TopVent-VerticalTermination ....................................................................................................31VerticalTermination ............................................................................................................. 32 - 33DVVK-5FFlexVentInstructions .......................................................................................... 34 - 35Framing And Finishing ......................................................................................................... 36 - 37Liner Installation...........................................................................................................................38GlassPlacement..........................................................................................................................39Multifunction Remote Operating Instructions ....................................................................... 40 - 46Lighting Instructions .....................................................................................................................47ControlSystemTroubleshooting.......................................................................................... 48 - 49Parts View ....................................................................................................................................50Parts List ......................................................................................................................................51ComponentWiringDiagram ........................................................................................................52MaintenanceAndService .................................................................................................... 53 - 56ImportantSafetyInformation .......................................................................................................57SafetyInformationForUsersOfPropaneGas ............................................................................58Requirements For Massachusetts ...............................................................................................59FireplaceServiceHistory ..................................................................................................... 60 - 61MasterPartsDistributorList ........................................................................................................62HowToOrderRepairParts ..........................................................................................................62Warranty ......................................................................................................................................63

SECTION PAGE

Page 5: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 5

Instructions to Installer1. Leave instruction manual with owner.2. HaveownerfilloutandmailProductRegistrationCard

suppliedwiththefireplace.3. Showownerhowtostartandoperatethefireplace.Thisdirect-ventgasfireplaceheaterisdesignedtooperatewithall combustion air being siphoned from the outside of the building andallexhaustgasesexpelledtotheoutsideofthebuilding.Theinformation contained in this manual pertains to all models and gas control systems unless otherwise noted.

Appliance Certification

WARNINGThis fireplace is not for use with solid fuels. Solid fuels could cause personal injury or property damage.

ThisfireplaceisdesigncertifiedinaccordancewithAmericanNationalStandard/CSAStandardANSIZ21.88/CSA2.33andbyUnderwritersLaboratoriesasaDirectVentGasFireplaceHeaterand shall be installed according to these instructions.Consult your local building code agency, prior to installation, to ensure compliance with local codes-including permits and inspections.Thefireplace,wheninstalled,mustbeelectricallygroundedinaccordance with local codes or, in absence of local codes, with the National Electric Code ANSI/NFPA 70orCanadianElectriccode,CSAC22.1,ifanexternalelectricalsourceisutilized.Thesemodelsmaybeinstalledinabedroomorbed-sittingroomintheU.S.A.andCanada.

Qualified Installing AgencyInstallationandreplacementofgaspiping,gasutilizationequipment or accessories and repair and servicing of equipment shallbeperformedonlybyaqualifiedagency.Theterm“qualifiedagency”meansanyindividual,firm,corporationorcompanywhich either in person or through a representative is engaged inandisresponsiblefor(a)theinstallationorreplacementofgaspipingor(b)theconnection,installation,repairorservicingof equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.

Commonwealth of Massachusetts: TheinstallationmustbemadebyalicensedplumberorgasfitterintheCommonwealthof Massachusetts.

WARNINGANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS CAN BE DANGEROUS.Improper installation or use of the fireplace can cause serious injury or death from fire, burns, explosions, or carbon monoxide poisoning.

Theinstallationmustconformwithlocalcodesor,intheabsenceof local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54* Natural Gas and Propane Installation Code, or CSA B149.1 in Canada. *Available from the American National Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10036.

Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.

ImportantAllcorrespondenceshouldrefertocompleteModelNumber,SerialNumberandtypeofgas.

High Altitude Wheninstallingthisfireplaceatanelevationabove2000feet(intheUnitedStates)itmaybenecessarytodecreasetheinputratingbychangingtheexistingburnerorificetoasmallersize.Generally,inputshouldbereduced4percentforeach1000feetabovesealevel.However,iftheheatingvalueofthegashas been reduced, this general rule may not apply. Check with EmpireComfortSystemsforproperorificesizeidentification.

Canadian High Altitude Altitude:0-4500feet(0-1370m)Wheninstallingthisfireplaceatanelevationabove4500feet(inCanada),checkwithEmpireComfortSystemsforassistanceindeterminingtheproperorificeforlocation.

PreparationThisdirectventgasfireplaceanditscomponentsaretestedandsafe when installed in accordance with this installation manual. Reporttoyourdealeranypartsdamagedinshipment,specificallycheckglasscondition.Donotinstallfireplacewithdamaged,incomplete, or substitute parts. Read all instructions before starting installation and follow these instructions carefully during installationtoinsuremaximumbenefitandsafety.Failuretofollowthemwillvoidyourwarrantyandmaypresentafirehazard.Thewarrantywillbevoidedby,andthewarranterdisclaimsanyresponsibility for the following actions:• Installationofanydamagedfireplaceorventsystem

component.• Modificationofthefireplaceordirectventsystem.• InstallationotherthanasinstructedbyEmpireComfort

SystemsInc.• Improperpositioningoftheglassdoor,ordecorative

accessories including logs, rocks, crushed glass or other approved media.

• Installationand/oruseofanycomponentpartnotmanufactured or approved by manufacturer.

Television ConsiderationsInstallingatelevisionaboveafireplacehasbecomeincreasinglypopular;however,theareasaboveanyfireplacegetshotandmostTVmanufacturersrecommendagainstplacingtheirproductsneara heat source.

Ifyouinstallatelevisionabovethisfireplaceinsert,EmpireComfortSystemsacceptsnoresponsibilityfordamageorinjuries.Followthe television manufacturers installation instructions, including any recommendations regarding proximity to heat sources.

IfyourhaveaTVaboveyourfireplaceturnoffthefireplaceandlet it cool completely before servicing or touching any buttons on theTV.

INTRODUCTION

Page 6: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 6

SPECIFICATIONSDVLL72BP

Natural PropaneInputBTU/HrMaximum 52,500 50,000InputBTU/HrMinimum 40,000 35,000

KWH(Maximum) 15.23 14.50KWH(Minimum) 11.60 10.15

Orifice #26 2.15mmAirShutterOpening 1/16-in Fully Open

Heightwithoutstandoff 38-5/16 38-5/16Width 81-in 81-inDepth 18-5/8-in 18-5/8-in

GasInletShutoffValve(pipe) 1/2-inNPT 1/2-inNPTVentSize 5 x 8 5 x 8

NOTICE: Airshuttersettingsarefactoryminimumsettings.Someventingconfigurationsmayrequireminorairshutteradjustmentsforoptimum performance.

GAS SUPPLY PRESSURES - (DIMENSIONS IN INCHES WATER COLUMN - W.C.)Gas Type Maximum Minimum ManifoldNatural 14 4.5 3.5

Propane 14 11 10

Page 7: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 7

ThefollowingaccessorypartscanbeobtainedfromyourEmpireComfortSystemsdealer.ContactyourEmpireDealerformoreaccessoryoptions.Ifyouneedadditionalinformationbeyondwhatyourdealercanfurnish,contactEmpireComfortSystemsInc.,918FreeburgAve.,Belleville, Illinois 62220-2623.

ACCESSORIESDescription Accessory Model Number

ColorFireplace Models DVLL72BP

BronzeRidgebackLiner* DVP72LPZ BronzeBlackGlassLiner DVP72LKR GlossBlack

TrimKit-BeveledBlack DF72BL BlackTrimKit-BeveledHammeredPewter DF72HP HammeredPewter

Beveled Window Frame - 2 inches DF702NB NickelBrushedDecorativeFront,ForgedIronFrame,

DistressedPewter DFF72FPD DistressedPewter

LogSet,BlueBayDriftwood LS60THF N/ALogs And Rocks, Rustic Contemporary LS72DC N/AConversionKit-PropanetoNatural 38156 N/AConversionKit-NaturaltoPropane 38157 N/A

*DVLL72BPmodelsrequireeitheraRidgebackLineroraBlackGlassLiner.Thefireplacemusthavealinerinstalledpriortooperation.

**NOTICE:Iftheoptionalblowerkitisdesired,installationintothefireplacethroughtherearaccesspaneliseasier,priortoplacingthefireplaceintotheframedoutlocation.

Forapplicationandtheamountofcrushedglasstouse,refertothe“GlassPlacement”sectiononpage39.

ACCESSORIES

Page 8: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 8

FBB20 BLOWER INSTALLATION

1

1

2

BLOWER ASSEMBLY PARTS LIST

INDEX NO.

PART NO DESCRIPTION QTY

1 35727 BlowerAssembly-Single 2

2 R11788 WireHarness 1

TOOLS NEEDED:5/16-inchNutdriverorscrewgun

CAUTIONSharp edges. Use gloves when installing these blowers.

Installation - Prior to Setting Fireplace Into Final Position1. UnpacktheFBB20Blowerassembly.

2. Usinga5/16-inchhexdrive,removethe11screwsholdingrear blower access cover plate, then lay the access plate on thefloor.See Figure 1.

Figure 1

3. Usearagtowipetheinsidebottomofthefireplace(wheretheblowerswillbeplaced)toremovedirtorconstructiondust.

4. Placeblowersonthefloorbehindthefireplace.Positionthe blowers with the two black connecting wires and green ground wire towards the left hand side when facing the back ofthefireplace.See Figure 2.

Figure 2

5. Locate the blower wire terminals inside the bottom of the fireplaceandmakethethreeconnectionsasshowninFigure 3.

Figure 3

Page 9: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 9

FBB20 BLOWER INSTALLATION (CONT’D)6. Begin installing the left blower assembly into the bottom of

thefireplace.Oncetheblowerisabouthalfwayin,securewiring within the white plastic wire retention clips provided in thefireplace.See Figure 4.

Figure 4

7. Finish installing the left blower so that the left edge of the blower base bracket is about even with the left edge of the access opening. Route the wiring away from the blower wheel. See Figure 5.

Figure 5

8. Next,installtherighthandblowerassemblytowardstherightsideoftheaccessopening.Therighthandedgeoftheblower base bracket should be about even with the right edge of the access opening. Route wiring away from the blower wheel. See Figure 6.

Figure 6

9. Snapthewireharnessintothewhiteplasticwireretentioncliplocatedatthecenterbottomofthefireplace.See Figure 7.

Figure 7

Page 10: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 10

FBB20 BLOWER INSTALLATION (CONT’D)10. Make sure the blower base brackets are pulled rearward

againstthebottomflangeofthefireplace.Themagnetsonthe blower base bracket will keep the blowers in place. See Figure 8.

Figure 8

11. Re-attach the Blower Access Panel with the 11 screws removed in step 2. See Figure 1.

12. Blower installation is complete.

Page 11: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 11

FIREPLACE DIMENSIONS

INDEX LETTER DIMENSION DESCRIPTION

DVLL72BP90(Dimensions in inches)

A Themaximumheightoffireboxface(excludingstandoffs) 38-1/4B Themaximumwidthofthefireboxface(excludingnailingflanges) 85C Themaximumdepthofthefireplace 19-1/2D Theheightofthefireboxopening 20E Thewidthofthefireboxopening 76-1/4F Theinteriordepthofthefirebox(notshown) 13

G Therearexteriorwidthofthefirebox 85H Theheighttothefireboxstandoffs 61-1/2I Width from the left side of the box to the centerline of vent 42-9/16J Depthfrombackofboxtocenterlineoftopvent 7-1/8K Heightfromthebottomoftheboxtothegaslineopening 15-7/8L Depthfromthefrontoftheboxtogaslineopening 14-11/16M Depthfromrearofboxtogaslineopening 3-3/4N Glassheight 15O Glasswidth 72P Depthfromfrontofboxtocenterlineofvent 12-3/8Q Distancefromfloortofireplaceopening 9-3/8R Heightfromfloortoventcollar 39-15/16S Overall height to header 61-5/8T Distancebetweenframingbracketends 93-1/16U Interiorrearwidthoffirebox(notshown) 69V Bottomoffireplacetoscreenopening 12-1/8

J

CP

G

I

E

HS

V

N

T

B

O

Q

D A

L M

K

R

Page 12: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 12

CLEARANCESCLEARANCE TO COMBUSTIBLESBack See Fig. 10Side 3-in Floor 0-in

TopStand-offBracket 0-in TopFramingEdge 23-3/8-in

SEE MANTEL CHART FORMAXIMUM MANTEL DEPTH

23 7/8” MIN.

2” X 4” HEADER

FRAMING STAND-OFF23 3/8” (594mm) HEIGHT

ABOVE TOP OF FIREPLACE

FINISHED WALL(COMBUSTIBLE)

NON-COMBUSTIBLEBOARD

TOP FRAMING LEDGESEE MANTEL CHARTFOR MINIMUM HEIGHT

OF MANTEL ABOVEUNIT OPENING

BARRIERSCREEN/GLASSFRONT

TOP HEADERSHIELD

NOTICE A: See Figure 12 for maximum mantel depth and minimumheightabovefireplace.

Figure 9

8”

3”

3” 2”

NOTE: COMBUSTIBLE MATERIALS ALLOWED IN SHADED AREA

3”

Figure 10

Theminimumclearancefrombottomofthefireplacetoceilingis 65-in.Theminimumclearancefromsideofthefireplaceopening to adjacent sidewall is 8-in.

8” MIN.

(20cm)

TO BOTTOM

OF CABINET

CEILING 55 1/2” MIN

(141cm)

65” MIN

(165cm)

Figure 11

Mantel Chart

TOP EDGE OFFIREPLACE OPENING

H

22”

34”

12”

A

3”MINIMUM

NO

N-C

OM

BU

ST

IBL

E M

AT

ER

IAL

ZO

NE

TOPHEADERSHIELD

INDEX LETTER

DISTANCE FROM FIREPLACE OPENING

(in inches)

DISTANCE FROM FINISHED WALL

(in inches)A 34 12B 34 10C 32 8-3/8D 30 6-5/8E 28 5F 26 3-3/8G 24 1-3/4H 22 0

Figure 12

Television ConsiderationsInstallingatelevisionaboveafireplacehasbecomeincreasinglypopular;however,theareaaboveanyfireplacegetshotandmostTVmanufacturersrecommendagainstplacingtheirproductsneara heat source.If you install a television above this fireplace, Empire ComfortSystemsacceptsnoresponsibilityfordamageorinjuries.Followthe television manufacturer’s installation instructions, includingany recommendations regarding proximity to heat sources.IfyouhaveaTVaboveyourfireplace,turnoffthefireplaceandlet it cool completely before servicing or touching any buttons on theTV.

TOPEDGEOFFIREPLACEOPENING

Page 13: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 13

NOTICE:IslandandRoomDividerinstallationispossibleaslongasthehorizontalportionoftheventsystemdoesnotexceed20feetwithaminimumverticalrunof8feet.SeedetailsinVentingSection.NOTICE:Wheninstallingthisfireplaceagainstanexteriorwall,insulatetoapplicableinsulationcodes.WhenyouinstallyourDirectVentFireplaceinRoomdividerorFlatonwallcornerpositions,aminimumof8inchesclearancemustbemaintainedfromtheperpendicularwallandthefrontopeningofthefireplace.

Figure 13

OPTIONAL FIREPLACE LOCATIONS

ROOM DIVIDERINSTALLATION

FLUSH WALLINSTALLATION

ISLANDINSTALLATION

CABINETINSTALLATION

CORNERINSTALLATION

ANGLED CORNERINSTALLATION

Page 14: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 14

Terminationclearanceforbuildingswithcombustibleandnoncombustibleexteriors.

Vertical Sidewall InstallationsImportant! Minimum clearance between vent pipes and combustible materials is 3 inch(76mm)ontop,and1 inch(25mm)onbottomandsides.Important! When vent termination exits through foundation less than20inch(508mm)belowsidingoutcrop,theventpipemustextendoutwardsothatthehorizontalventterminationislocatedflushto,orbeyondtheoutcropsiding.Information on Various Venting Routes and ComponentsImportant:Itisalwaysbesttolocatethefireplaceinsuchawaythatminimizesthenumberofoffsetsandhorizontalventlength.Sinceitisveryimportantthattheventingsystemmaintainitsbalancebetweenthecombustionairintakeandthefluegasexhaust,certainlimitationsastoventconfigurationsapplyandmust be strictly adhered to.

Figure 14

VENT TERMINATION CLEARANCES

Thegraphshowingtherelationshipbetweenverticalandhorizontalsidewallventingwillhelptodeterminethevariousventlengths allowable.Thehorizontalventrunreferstothetotallengthofventpipefromthefluecollarofthefireplacetothefaceoftheouterwall.Venting termination shall not be recessed into wall or siding.

ATTENTION: Vinyl Soffit, Vinyl Ceiling, Vinyl Overhang DisclaimerClearancesaretoheatresistantmaterial(i.e.wood,metal).Thisdoesnotincludevinyl.EmpireComfortSystemsInc.will not be held responsible for heat damage caused from terminating under vinyl overhangs, vinyl ceilings or vinyl ventilated/unventilatedsoffits.

RECESSED LOCATIONOUTSIDE CORNERINSIDE CORNER

“A” = COMBUSTIBLE 9” (229mm)= NONCOMBUSTIBLE 2” (51mm)

“F” = COMBUSTIBLE 6” (152mm)= NONCOMBUSTIBLE 6” (152mm)

BALCONYWITH PERPENDICULAR SIDE WALL

BALCONYWITH NO SIDE WALL

“C” = CLEARANCE FROM CORNERIN RECESSED LOCATIONCOMBUSTIBLE 9” (229mm)NONCOMBUSTIBLE 2” (51mm)

“D” = MINIMUM WIDTH FOR BACK WALLOF A RECESSED LOCATIONCOMBUSTIBLE 38” (965mm)NONCOMBUSTIBLE 24” (610mm)

“E” = MAXIMUM DEPTH OF 48” (1219mm)FOR RECESSED LOCATION

“G” = COMBUSTIBLE 9” (229mm)= NONCOMBUSTIBLE 2” (51mm)

“H” = COMBUSTIBLE 18” (457mm)= NONCOMBUSTIBLE 12” (305mm)

“I” = COMBUSTIBLE 12” (457mm)= NONCOMBUSTIBLE 12” (305mm)

Page 15: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 15

VENT TERMINATION CLEARANCES (CONT’D)

Canadian Installations1 USInstallations2 Canadian Installations1 USInstallations2

A= Clearance above grade, veranda, porch, deck, or balcony

12in(30cm) 12in(30cm)I= Clearance to service

regulator vent outlet 3ft(91cm) 6 ft

B= Clearance to window or door that may be open

6in(15cm)forappli-ances≤10,000Btuh (3kW),12in(30cm)for appliances > 10,000 Btuh(3kW)and≤100,000Btuh(30kW),36in(91cm)forappli-ances > 100,000 Btuh (30kW)

6in(15cm)forappli-ances≤10,000Btuh(3kW),9in(23cm)forap-pliances > 10,000 Btuh (3kW)and≤50,000Btuh(15kW),12in (30cm)forappliances>50,000Btuh(15kW)

J= Clearance to nonme-chanical air supply inlet to building or the combustion air inlet to any other appliance

6in(15cm)forappli-ances≤10,000Btuh(3kW),12in(30cm)forappliances > 10,000 Btuh(3kW)and≤100,000Btuh(30kW),36in(91cm)forappli-ances > 100,000 Btuh (30kW)

6in(15cm)forappli-ances≤10,000Btuh(3kW),9in(23cm)forappliances > 10,000 Btuh (3kW)and≤50,000Btuh(15kW),12in(30cm)forappliances > 50,000 Btuh (15kW)

C= Clearance to permanently closed window

12in(30cm) 12in(30cm)K=Clearancetoamechani-

cal air supply inlet 6ft(1.83m)3ft(91cm)aboveifwithin10ft(3m)hori-zontally

D=Verticalclearanceventilatedsoffitlocatedabove the terminal within ahorizontaldistanceof2feet(61cm)fromthecenter line of the terminal

24in(61cm) 24in(61cm)

L= Clearance above paved sidewalk or paved drive-way located on public property 7ft(2.13m)† 7ft(2.13m)†

E=Clearancetounventilatedsoffit 12in(30cm) 12in(30cm)

M= Clearance under veranda, porch deck, or balcony

12in(30cm)‡ 12in(30cm)‡

F= Clearance to outside corner 6in(15cm) 6in(15cm) 1 InaccordancewiththecurrentCSAB149.1,NaturalGasandPropaneInstal-

lation Code

G=Clearanceinsidecorner 9in(23cm) 9in(23cm) 2 InAccordancewiththecurrentANSIZ223.1/NFPA54,NationalFuelGasCode

H=Clearancetoeachsideof center line extended abovemeter/regulatorassembly

3ft(91cm)withinaheight15ft(4.5m)abovethemeter/regula-tor assembly

3ft(91cm)

† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings

ATTENTION: Vinyl Soffit, Vinyl Ceiling, Vinyl Overhang DisclaimerClearancesaretoheatresistantmaterial(i.e.wood,metal).Thisdoesnotincludevinyl.EmpireComfortSystemsInc.willnotbeheldresponsible for heat damage caused from terminating under vinyl overhangs,vinylceilingsorvinylventilated/unventilatedsoffits.

‡ Permitted only if veranda,, porch, deck, or balcony is fully open on a minimum oftwosidesbeneaththefloor.

* ForclearancesnotspecifiedinANSIZ223.1/NFPA54orCSAB149.1,oneofthe following shall be indicated:

Clearance in accordance with local installation codes and the requirements of the gas supplier.

Page 16: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 16

GAS SUPPLYThegaspipelinecanbebroughtinthroughtherightsideofthefireplace.ConsultthecurrentNationalFuelGasCode,ANSIZ223.1CAN/CGA-B149(.1or.2)installationcode.

NOTICE:Neveruseplasticpipe.Checktoconfirmwhetheryourlocalcodesallowcoppertubingorgalvanized.NOTICE: Sincesomemunicipalitieshaveadditionallocalcodes,itis always best to consult your local authority and installation code.Theuseofthefollowinggasconnectorsisrecommended:— ANSIZ21.24ApplianceConnectorsofCorrugatedMetal

TubingandFittings.— ANSIZ21.45AssembledFlexibleApplianceConnectorsof

OtherThanAll-MetalConstructionTheaboveconnectorsmaybeusedifacceptablebytheauthorityhavingjurisdiction.TheCommonwealthofMassachusettsrequiresthataflexibleapplianceconnectorcannotexceedthreefeetinlength.

Figure 15

Gas Supply Pressure (inches w.c.)

Minimum Normal Maximum

NaturalGas 4.5 7.0 14.0

PropaneGas 10.8 11.0 14.0

Manifold Pressure (inches w.c.)

Normal (HI)

NaturalGas 3.5

PropaneGas 10.0

A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing. It is required bytheNationalFuelGasCodethatadriplegbeinstallednearthegas inlet. See Figure 16. Thisshouldconsistofaverticallengthof pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect.

Figure 16

Installing a New Main Gas Shut-Off Valve (Check Local Code)Eachfireplaceshouldhaveitsownmanualgasshut-offvalve.A manual main gas shut-off valve should be located in the vicinity ofthefireplace.Wherenoneexists,orwhereitssizeorlocationisnotadequate,contactyourlocalauthorizedinstallerforinstallation or relocation.Compounds used on threaded joints of gas piping shall be resistanttotheactionofliquefiedpetroleumgases.Thegaslinesmustbecheckedforleaksbytheinstaller.Thisshouldbedone with a soap solution watching for bubbles on all exposed connections, and if unexposed, a pressure test should be made.

Never use an exposed flame to check for leaks. Fireplace must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test. Never pressure test with fireplace connected; control valve will sustain damage!NOTICE: Thegascontrolisequippedwithacapturedscrewtypepressuretestpoint,thereforeitisnotnecessarytoprovidea1/8inch test point up stream of the control. See Figure 17.Whenusingcopperorflexconnectoruseonlyapprovedfittings. Thefireplaceandit’sindividualshutoffvalvemustbedisconnected from supply piping system during any pressure testingofthatsystemattestpressuresinexcessof1/2psig(3.5kPa).Thefireplacemustbeisolatedfromthegassupplypipingsystemby closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to orlessthan1/2psig(3.5kPa).Attention! If one of the procedures results in pressures in excess of1/2psig(14inw.c.)(3.5kPa)onthefireplacegasvalve,itwillresultinahazardouscondition.

GAS SUPPLY PIPING

Page 17: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 17

GAS SUPPLY (CONT’D)Checking Manifold PressuresBothPropaneandNaturalGasvalveshaveabuilt-inpressureregulatorinthegasvalve.NaturalGasmodelswillhaveamanifoldpressureofapproximately3.5-inw.c.(.871kPa)atthevalve outlet with the inlet pressure to the valve from a minimum of4.5-inw.c.(1.120kPa)forthepurposeofinputadjustmenttoamaximumof14.0-inw.c.(3.484kPa).PropaneGasmodelswillhaveamanifoldpressureapproximately10.0-inw.c.(2.49kPa)at the valve outlet with the inlet pressure to the valve from a minimumof10.8-inw.c.(2.68kPa)forthepurposeofinputadjustmenttoamaximumof14.0-inw.c.(3.484kPa).

CAUTIONIf one of the procedures results in pressures in excess of 1/2 psig (14-in w.c.) (3.5 kPa) on the fireplace gas valve, it will result in a hazardous condition.

GAS VALVE

OUTLETPRESSURETAP

INLETPRESSURETAP

Figure 17

Gas Line ConnectionRemovetheaccesspanelfromtherightsideofthefireplaceshown in Figure 18toaccessthegasvalve,gasflexline,junction box, and system wiring.Attachthegasflexlinetothepre-installedgasline.RefertotheGasSupplysectioninthismanualfordetailsontheinstallationrequirements for the gas supply line.

15 7/8

14 5/8

ACCESS PANEL

NAILING FLANGE

JUNCTION BOX

REMOTE WALL BOXWIRING EXIT POINT

GAS LINEACCESS

Figure 18

Page 18: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 18

ELECTRICAL CONNECTIONS

CAUTIONAll wiring should be done by a qualified electrician and shall be in compliance with all local, city and state building codes. Before making the electrical connection, make sure that the main power supply is disconnected. The fireplace, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70 (Latest Edition).

A factory installed junction box is located on the lower right sideofthefireplace.Wiringmustbefedtothejunctionboxandattached to the receptacle that is provided. Leave approximately 6in of wire in the junction box for connection.Attach black wire to one side of the receptacle and white wire to oppositesideofreceptacle.Thegroundwireshouldbeattachedtothegreen(ground)screw.See Figure 19.

BLACK (HOT)

BRASS SCREWS

JUNCTION BOX

GROUND

SILVER SCREWS

GREEN SCREWWHITE

(NEUTRAL)

120 VOLT POWER SUPPLY

Figure 19

Install the receptacle into the junction box. Attach cover plate.After the wiring is completed to the junction box and receptacle, installthejunctionboxtothelowerrightsideofthefireplaceasshown in Figure 20.Insertthetopflangeoftheretainerbracketintotheslotonthefireplace.Rotatethejunctionboxassemblydownward, and secure with a screw below the junction box. See Figure 20.

Control Module Access:Toaccessthecontrolmoduleforservicing,removethebarrierscreenandglassdoorassemblies.Thecontrolmoduleislocatedinthebottomrightsideopening.ThecontrolmoduleislocatedtothefireplacebottomwithVelcro®,andcanbelifteduptoaccessthe module wiring connections.

Figure 20

JUNCTION BOX CONNECTIONS

Page 19: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 19

Once the Junction box has been installed with the receptacle outletsfacinginwardtowardsthefireplace,locatethe3-prongpower cord from the control module and plug into the receptical.

Inaddition,locatethe3-prongpowercordfromtheLEDLightTransformerandplugintothejunctionboxreceptacle.ThefireplaceissuppliedwithaUserInterfacewallboxthatmustbeinstalledinastandardplasticoutletbox(notprovided).Alowvoltageorangeorblueboxisrecommended.Theuserinterfacewall box must be placed in the wall within ten feet from the right sideofthefireplace.10-feetbatteryanduserinterfaceextensionwire harnesses are supplied. See Figures 21- a,b,c.Install the wall-mounted control box within 8 feet to the right side or 2 feet from the left. See Figure 21a.

WALL MOUNTCONTROL BOX

6” MIN

10’ MAX WIREEXTENSION LENGTH

Figure 21aRoutetheyellowLEDwireharnesswithagrayremotereceiverharness through the bushing. Mount the controls and connect the wiring. See Figure 21b.

REMOTESWITCH

COVER PLATE

YEL/BLACK

10” EXTENSION WIRE

YELLOW EXTENSION WIRE

RED/BLACK

TO FIREPLACECONTROL MODULE

LED SWITCHON/OFF

LED SWITCHCOLOR MODE

FROM FIREPLACELED CONTROLS

Figure 21b

ELECTRICAL CONNECTIONS (CONT’D)Place batteries in remote receiver and in the remote control using instructions provided. Place the switch slider to the remote switch.Settheremoteswitchinwallboxtoremote.(centerposition)See Figure 21c.

REMOTEPOSITION

REMOTESWITCH

SWITCHSLIDER

Figure 21cVerifyremoteiscommunicatingwithreceiver.(SeeProflamecontrolsystempage41).

Install the provided plastic bushing in the opening where the wiresexitthefireplace.See Figure 22 (right side).Theredandblackbatteryextensionharnessisconnectedtothe red and black mating connector pre-installed on the control module.Thematingconnectorcanbelocatedinsidethefireplacenear the gas valve. See Figure 22.Locateandinstallthe5/8inchdiameterplasticsnap-ingrommetaroundthelow-voltagebatteryinterfaceextensionandLEDwireharnessesattherightsideofthefireplace.Snapthegrommetintotheholeinthesideofthefireplacejustundertheaccesspanel opening. See Figure 22.

Run the extension wiring harnesses to the user interface wall box and connect the white connector to the remote receiver battery box. Install the battery box into the wall outlet box, then install the white remote cover supplied with the provided screws.

HAND BENTFLANGE

WIREGROMMET

USER INTERFACE HARNESS& BATTERY EXTENSION

HARNESS

CONNECT TO THE USER INTERFACE/BATTERYHOLDER. MUST BE INSTALLED IN A WALLJUNCTION BOX (ORANGE LOW VOLTAGE ORBLUE BOX RECOMMENDED)

NOTE: OUTER ACCESS DOOR REMOVED. REPLACE AFTER ALLWIRE AND GAS CONNECTIONS HAVE BEEN MADE

LED WIREHARNESS(YELLOW)

NOTICE: OUTERACCESSDOORREMOVED.REPLACEAFTERALLWIREANDGASCONNECTIONSHAVEBEENMADE.

Figure 22

Page 20: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 20

INSTALLATIONFramingThis fireplace can be elevated off the floor provided that the fireplace is properly supported by framing materials and the ceiling clearances are maintained.Fireplaceframingcanbebuiltbeforeorafterthefireplaceissetin place. Framing should be positioned to accommodate wall coveringandfireplacefacingmaterial.Thefireplaceframingshould be constructed of 2 x 4 lumber. Refer to Figure 23 for minimum framing dimensions.

CAUTIONMeasure fireplace dimensions and verify framing methods, and wall covering details before framing construction begins.

Framing dimension A includes a 24-inch clearance for framing standoffs on fireplace. After installing fireplace into framing, the non-combustible board must cover the 24-inch opening above the fireplace.

NOTICE:Forfinishingtotopoffireplace,refertoFigures 28 and 30.

B

C

A

C

INDEX LETTER DVLL72

A 61-5/8inB 91-5/8inC 21-1/2in

Figure 23

Construction of a Fireplace ChaseA chase is a vertical box-like structure built to enclose the gas fireplaceand/oritsventsystem.Incoolerclimatestheventshouldbe enclosed inside the chase. NOTICE: Treatment of ceiling firestops and wall shield firestops and construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Therefore, you MUST check local building codes to determine the requirements to these steps.A chase should be constructed in the manner of all outside walls of thehometopreventcoldairdraftingproblems.Thechaseshouldnot break the outside building envelope in any manner. Walls,ceiling,baseplateandcantileverfloorofthechaseshouldbeinsulated.Vaporandairinfiltrationbarriersshouldbeinstalledin the chase as per regional codes for the rest of the home. Additionally,inregionswherecoldairinfiltrationmaybeanissue,theinsidesurfacesmaybesheetrockedandtaped(oranequivalentmethodmaybeused)toachievemaximumairtightness.

Tofurtherpreventdrafts,thewallshieldandceilingfirestopsshould be caulked with caulk rated for a minimum of 300°F continuousexposureratingtosealgaps.Gaslineholesandother openings should be caulked or stuffed with unfaced insulation.Ifthefireplaceisbeinginstalledonacementsurface,a layer of plywood may be placed underneath to prevent conducting cold up into the room. See Figure 23.Framing and Finishing 1. Choosefireplacelocation.Seepages14-15.2. Frameinfireplacewithaheaderacrossthetop.Itis

importanttoallowforfinishedfacewhensettingthedepthofthefireplace.

3. SecurethefourframingbracketsandhandbendthemintoaV shape as shown in Figure 24.Securewith#10x1/2-inchhex-head screws.

4. Locatethenailingflangesonthesidesofthefireplace(twoeachside).See Figure 24.

Figure 24

Page 21: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 21

INSTALLATION (CONT’D)Header Shield/Top Standoff Assembly1. ThetwoHeaderShieldhalvesand(4)TopStandoffsare

packagedtogetherandshippedwiththefireplace.Pre-assembleeachoftheHeaderShieldhalvestotwooftheTopStandoffbrackets,beforeinstallingtothetopofthefireplaceand framing header. See Figure 25.

BEND SUPPORT TABDOWN AND SECURETO THE HEAT SHIELD

WITH (1) SCREWTHROUGH EACH BRACKET

INTERLOCK HEADER SHIELDTO STANDOFF BRACKETS

BEND TABS OVER AND INSTALL(2)SCREWS TO EACH STANDOFF BRACKET

Figure 25

2. Install the first TopStandoffandHeaderShieldassemblytothetopofthefireplaceandframingheader.See Figure 26.

Install the secondTopStandoffandHeaderShieldassemblytothetopofthefireplaceandframingheader.See Figure 27. Next,connecttheoverlappedendsofthetwoheadershields,andsecurethemtogetherusingtheprovided(3)#10x1/2HexHeadscrews.

HEADER SHIELD

OVERLAP SHIELDSAND SECURE WITH(3) # 10 X ½ SCREWS

TOP FRONTOF FIREPLACE

TOP STANDOFFBRACKET

SECURE TOP STANDOFFSTO TOP OF FIREPLACEWITH (2) # 10 X ½ SCREWS EACH

HAND BEND TOP FLANGEOF EACH STANDOFF, THENSECURE TO HEAT SHIELDWITH # 10 X ½ SCREWS

Figure 26

REAR VIEW OFFIREPLACE ANDHEADER SHIELD

(VENTING REMOVEDFOR CLARITY)

Figure 27

3. Securefireplacetoframingwithnailingflanges.Presetdepthtosuitfacingmaterial(flushor1/2inchsetbackdepths).See Figure 28.

NAILING FLANGESSECURED TO

FRAMING

Figure 28

Page 22: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 22

INSTALLATION (CONT’D)4. Attach the four middle mount framing brackets to the top

frontedgeofthefireplace.Thesebracketssupportthesuppliednon-combustibleboardabovethefireplace.Presetdepthtosuitfacingmaterial(flushor1/2inchsetbackdepths).See Figure 29.

FLUSH

½” SET BACK

MIDDLE MOUNTBRACKETS (4)

TOP FRONT EDGEOF FIREPLACE

Figure 29

Vent Pipe Clearance

NOTICE: Maintain one inch of clearance around vertical vent pipe. See Figure 30.

Forhorizontalvent,maintainaminimum1inchclearanceto the bottom and sides of the vent, and 3 inch clearance to combustibles above the vent pipe. See Figure 31.

VENT PIPE

1” MINIMUM CLEARANCE AROUNDVERTICAL VENT PIPE

Figure 30

Figure 31

Flush Wall Installation

NON-COMBUSTIBLE MATERIAL

2 X 4HEADER

FINISHED WALL

JOINT BETWEEN FINISHEDWALL AND UNIT SEALED

WITH 300°F (149°C)SEALANTMATERIAL

Figure 32

Page 23: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 23

INSTALLATION (CONT’D)Finishing Methods

2” X 4” HEADERFINISHED WALL(COMBUSTIBLE)

NON-COMBUSTIBLEBOARD(SUPPLIED WITHTHE FIREPLACE)

TOP FRAMING LEDGE

TOP HEADERSHIELD

Figure 33

2” X 4” HEADERFINISHED WALL(COMBUSTIBLE)

NON-COMBUSTIBLEBOARD INSTALLEDTO TOP OFFIREPLACE OPENING(NOT SUPPLIED WITHFIREPLACE)

TOP FRAMING LEDGE

TOP HEADERSHIELD

Figure 34

NON - COMBUSTIBLEBOARD FLUSH TOFIREPLACE FACE (SUPPLIED)

NON - COMBUSTIBLEBOARD OVERFIREPLACE FACE(NOT SUPPLIED)

Figure 35

Finishing Options• Non-Combustibleboardinstalledoverthefireplaceface

(framingbracketflush).See Figure 32.• Non-Combustibleboardinstalledflushtoface(framing

bracketsat1/2inchsetback).See Figure 33.• Figures 33 and 34showbothfinishingoptions.• UseNon-Combustiblematerialswhereindicatedforthe

fireplaceinstallation.Non-combustiblematerialsdonotigniteorburnasaresultofusingthefireplace.Theseinclude metal, brick, ceramic, concrete, slate, glass and plaster. Adhesives must be rated for high temperatures. Any mechanical fasteners used to install material must also be non-combustible, including wall anchors and tile spacers. MaterialsthatpasstheASTME136test(StandardTestMethodforBehaviorofMaterialsinaVerticalTubeFurnaceat750C)areconsiderednon-combustible.

Attention: Cold climate installation recommendation: When installingthisfireplaceagainstanon-insulatedexteriorwall,itis recommended that the outer walls be insulated to conform to applicable insulation codes.

Vent RunsInplanningtheinstallationforthefireplace,itisnecessarytoinstallcertaincomponentsbeforethefireplaceiscompletelypositionedandinstalled.Theseincludethedirectventsystem,gas piping and electrical wiring. Thefireplacecanbemountedonanyofthefollowingsurfaces:1. Aflat,hardcombustibleornon-combustiblesurface.2. A raised wooden platform.

Page 24: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 24

INSTALLATION (CONT’D)VERTICAL, 90-DEGREE ELBOW WITH HORIZONTAL TERMINATION

2’(610mm)

12” MINIMUM(305mm)

VERTICAL VENTREQUIRED

MAXIMUM HORIZONTALRUN WITH MINIMUMVERTICAL RISE AND

90° ELBOW

Figure 36

VERTICAL, 90-DEGREE ELBOW TO HORIZONTAL OUT THEWALL (12-in minimum rise before elbow)

90° ELBOW “A” PIPELENGTH

FIRESTOP SPACER(INCLUDED)

VENT CAP

WALL FIRESTOP/THIMBLE

B

C

A B CVent Pipe

LengthCenterline of Flue To The Exterior of Wall

Wall Thickness

(Dimensions in inches)6 14 7 Maximum9 15-1/2-18 8-1/2-11

12 18-20-1/2 11-13-1/2

Figure 37

CORNER INSTALLATION - VERTICAL, 90-DEGREE ELBOWTO HORIZONTAL OUT THE WALL (12-in minimum rise before elbow)

NOTE: DIMENSIONS SHOWN WITH FRAMINGSET ½” BEHIND THE FIREPLACE FACE

A

DBC

ModelA B C D

(Dimensions in inches)DVLL72BP 125-5/8 62-11/16 88-7/8 36-1/16

Figure 38

NOTICE: Corner installation will require more vertical vent pipe than just the minimum required depending on wall thickness and horizontaldimension.Refer to Figure 46, page 29.

Page 25: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 25

ThisPageIntentionallyLeftBlank.

Page 26: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 26

Begin the vent system installation by selecting the type of venting to be installed and the path it will take. Verify clearances are met throughout the path of the venting system. NOTICE:Somefireplacescannotbeventedouttherearofthefireplace.Determinehowtheventsystemwillbeterminatedouttheside of the house or through the roof. Verify clearances for the termination.Whenselectingaventsystemforusewiththefireplace,refertothe“SpecialVentSystems”sectioninthismanualtodetermine

what systems are acceptable. Check all clearances and venting components. Identify if any problems exist in the vent system. UseFigure 46 on page 29 for top venting to eliminate issues after installation. Check pipe diameter on vent system and fireplacetoverifythesizeisthesame.NOTICE: All outer connection joints must be sealed with aluminum tape, screws or silicone sealant rated above 300°F/149°C.Theinnerfluejointsdonotrequireanysealant.

VENT SYSTEM IDENTIFICATION

Special DV Vent KitsAvailable from Empire Comfort Systems, Inc. dealers.

DVVK-5TP

Direct-VentFireplaceVentKitforTopVent,Thru-the-wall,4to6-inchwallthickness,Includes58DVA-E90,58DVA-HC,58DVA-06,and58DVA-WT

DVVK-5VPDirectVentFireplaceVentKit-Vertical,Includes58DVA-VCH,58DVA-SC,and58DVA-F6

DVVK-5TS TopVentKit(Horizontal)-4½inchto6-inchwallthickness(114.3mmto152mm)

DVVK-5F HorizontalFlexVentKit(4'Flex)(1.22m)

VENT SYSTEMSThefollowingventsystemsareacceptableforusewiththeDVLL72BP90seriesfireplaces:SimpsonDuravent®GS5in-8inAmerican Metal Products 5in - 8inSelkirkDirect-Temp®5in-8inSecuritySecureVent®5in-8inExcelDVVenting5in-8in

EmpireFlexventKitDVVK-5F(Requires6-inchsectionofhardventpipetoraiseconnectionpointofflexvent)BDM-5in-8inMetalFab5in-8in(Requiresa5DDAVentAdapter–Availablefromtheventingsupplier)

Figure 39

FLASHING

STORMCOLLAR

VERTICALTERMINATION(THREE 90°ELBOWS MAX)

WALLTHIMBLE

HORIZONTALTERMINATION

(THREE 90°ELBOWS MAX)

90° ELBOWOR

45° ELBOW

90° ELBOW

CEILINGFIRE STOP

WALL STRAP

PIPE LENGTH

THIMBLESPACER

Page 27: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 27

VENTING FIREPLACE - TOPWARNING

Use flue restrictor for vertically terminated fireplaces only. Do not use for horizontally terminated fireplaces.

Figures 40 to 43 show the location and recommended opening forthefluerestrictor.Installationofrestrictorbeforeventingisattached. See Figure 37.

Figure 40

NOTICE: Wheninstallingfluerestrictor,installwithscrewpointingdownward.For installation of the restrictor after the venting is installed, remove(2)screwsfromeachendofthefluebaffleandsetaside.Inserttherestrictorupintothefluecollarandpositionitasshownin Figures 41 and 42.Then,re-installthefluebaffle.

REMOVE BAFFLETO INSTALLFLUE RESTRICTOR

FLUE RESTRICTOR

Figure 41

REMOVE BAFFLETO INSTALLFLUE RESTRICTOR

FLUE RESTRICTOR

Figure 42

Figure 43

A1

CENTER OF ELBOW

STRAIGHT OUT

(MINIMUM)

A2

CENTER OF ELBOW

STRAIGHT OUT

(MINIMUM)

FIREPLACESERIES

HARD ELBOW DIMENSIONSA1 B C D

(Dimensions in inches)DVLL72 56-3/4 5-3/8 7-5/8 10-5/8

FIREPLACESERIES

FLEX PIPE 90 DEGREE BENDA2 B C D

(Dimensions in inches)DVLL72 56-3/4 5-3/5 7-5/8 10-5/8

Minimum hole location dimensions for through-the-wall horizontal installations with 90-degree elbow and 12 inch rise off top of fireplaceSee Figure 46 onpage27forpermissiblehorizontalandverticalrun dimensions.

Figure 44

FLUERESTRICTOR

FLUERESTRICTOR

REMOVEBAFFLETOINSTALLFLUERESTRICTOR

REMOVEBAFFLETOINSTALLFLUERESTRICTOR

FULLOPENANDFOURINDICATEDHOLESALIGNED

Page 28: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 28

VENTING FIREPLACE - TOP (CONT’D)Positioning the FireplaceDeterminetheexactpositionofthefireplacesothedirect-ventterminationwillbecentered(ifpossible)betweentwostuds.Thiswillavoidanyextraframing.Allventkitpipesshouldbeassembledonthefireplaceafterthefireplaceismovedintothefinalposition.

Cutting the HoleAfterthefireplacehasbeenpositionedinitspermanentlocation,theholethroughtheexteriorwallcanbecut.Thisholemustbe13-in(330mm)highx10-5/8-in(270mm)widewithitscenterlinedeterminedbytheamountofverticalriseandhorizontalrunofthe termination. See Figures 44 and 45. When locating the hole it must be noted that the bottom of the cap must be minimum of 12-in(305mm)abovethegroundlevel,andtopofthecapmustbenolessthan18-in(457mm)belowacombustibleprojection,andnocloserthan9-in(229mm)toanywallrunningparalleltovent termination.

U:\INSTRUCTIONS\Instructions Original Graphics\DVLL60BP\DVLL Vent Cap Clearance - 061515

Figure 45

Below Grade InstallationWhen it is not possible to meet the required vent termination clearancesof12inch(305mm)abovegradelevel,asnorkelkit is recommended. It allows installation depth down to 7 inch (178mm)belowgradelevel.The7inch(178mm)ismeasuredfromthecenterofthehorizontalventpipeasitpenetratesthrough the wall.Ensure the sidewall venting clearances are observed. If venting system is installed below ground, we recommend a window well with adequate and proper drainage to be installed around the termination area.

TYPICAL BASEMENT INSTALLATION

12” (30.5cm) ABOVEGRADE OR AVERAGE

EXPECTED SNOW LEVEL

Figure 46

ATTENTION: Vinyl Soffit, Vinyl Ceiling, Vinyl Overhang DisclaimerClearancesaretoheatresistantmaterial(i.e.wood,metal).Thisdoesnotincludevinyl.EmpireComfortSystemsInc.will not be held responsible for heat damage caused from terminating under vinyl overhangs, vinyl ceilings or vinyl ventilated/unventilatedsoffits.

Page 29: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 29

VENTING FIREPLACE - TOP (CONT’D)To Use the Vent Graph1. Determinetheheightofthecenterofthehorizontalvent

pipe.UsingthisdimensionontheSidewallVentGraph,locate the point it intersects with the slanted graph line.

2. From the point of this intersection, draw a vertical line to the bottom of the graph.

3. Selecttheindicateddimension,andpositionthefireplaceinaccordance with same.

EXAMPLE A:Iftheverticaldimensionfromthefloorofthefireplaceis32feet,thehorizontalruntotheouterwallflangemustnotexceed5feet.EXAMPLE B:Iftheverticaldimensionfromthefloorofthefireplaceis24feet,thehorizontalruntotheouterwallflangemustnotexceed10feet.

EXAMPLE C:Ifthehorizontalruntotheouterwallflangeis17feet,theverticaldimensionfromthefloorofthefireplacetothecenterofthetermination must not be less than 7 feet 6 inches.SPECIAL NOTE: Foreach45°elbowinstalledinthehorizontalrun,thelengthofthehorizontalrunMUSTbereducedby18inches.Reduceby3feetforevery90°elbow.Thisdoesnotapplyif the 45° elbows are installed on the vertical part of the vent system. Example:Accordingtothechartthemaximumhorizontalvent length is 20 feet and if two 45° elbows are required in the horizontalventitmustbereducedto17feet.Themaximumnumberof45°elbowspermittedpersidewallinstallationistwo.Theseelbowscanbeinstalledineithertheverticalorhorizontalrun.Themaximumnumberof90°elbowsinaventrunisthree.

Acceptableverticalandhorizontalventrun. (40'maximumverticaland20'maximumhorizontal)

Unacceptableverticalandhorizontalventrun. SeetextaboveforExamplesA,BandC.

Figure 47

VENTING GRAPH (Dimensions in Feet)

A

C

B

HORIZONTAL RUN

VE

RT

ICA

LD

IME

NS

ION

FR

OM

TH

E B

OT

TO

M O

FT

HE

UN

ITT

OT

HE

CE

NT

ER

OF

TH

EF

LU

E O

UT

LE

TW

ITH

VE

RT

ICA

LO

R H

OR

IZO

NTA

LT

ER

MIN

AT

ION

S C

AP

S

Page 30: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 30

TOP VENT - HORIZONTAL TERMINATIONOne 90° Elbow

ATO BOTTOM

OF UNIT

B

INSTALLEDVERTICALLY

1’MINIMUM

EXAMPLE VENT RUNSINITIAL PIPE

LENGTH A (Vertical) B (Horizontal)MAXIMUM

(Dimensions in inches)

12 55 Natural-24Propane - 12

24 67 4236 79 108(9ft)48 91 168(14ft)

Figure 48NOTICE: Pipe straps must be used every 2 feet to secure venting.

Two 45° ElbowsInstallation requirements to replace the first 90° elbowwith two45° elbows:

B

A

EXAMPLE VENT RUNSINITIAL PIPE

LENGTH A (Vertical) B (Horizontal)MAXIMUM

(Dimensions in inches)12 66 7224 80 132(11ft)36 91 204(17ft)48 103 240(20ft)

Figure 49

Two 90° ElbowsNOTICE:Subtract3 feet from the totalhorizontalmeasurementforeach90°elbowinstalledhorizontally.Subtract1-1/2feetfromthe total horizontal measurement for each 45° elbow installedhorizontally.

EXAMPLE VENT RUNSINITIAL PIPE

LENGTH A (Vertical) B (Horizontal)MAXIMUM

(Dimensions in inches)12 55 0’24 67 636 79 72(6ft)48 91 132(11ft)

Figure 50Three 90° Elbows

1’MININUM

B

INSTALLEDVERTICALLY

INSTALLEDVERTICALLY

ATO BOTTOM

OF UNIT

EXAMPLE VENT RUNSINITIAL PIPE

LENGTH A (Vertical) B (Horizontal)MAXIMUM

(Dimensions in inches)12 55 1824 67 24(2ft)36 79 90(7ft,6in)48 91 114(9ft,6in)

Figure 51

Page 31: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 31

TOP VENT - VERTICAL TERMINATIONNo Elbows

DIMENSIONS (in inches)MINIMUM MAXIMUM120(10ft) 480(40ft)

Figure 52

Two 90° Elbows

EXAMPLE VENT RUNSINITIAL PIPE

LENGTHA (Vertical)MINIMUM

B (Horizontal)MAXIMUM

(Dimensions in inches)12 120(10ft) 222(18ft,6in)24 120(10ft) 222(18ft,6in)36 120(10ft) 222(18ft,6in)48 120(10ft) 222(18ft,6in)

*Maximumhorizontalrunis100%ofvertical,butcannotexceed20 feet.

Figure 53

Three 90° ElbowsNOTICE:Subtract3feetfromthetotalhorizontalmeasurementforeach90°elbowinstalledhorizontally.Subtract1-1/2feetfromthetotalhorizontalmeasurementforeach45°elbowinstalledhorizontally.

EXAMPLE VENT RUNSINITIAL PIPE

LENGTHA (Vertical)MINIMUM

B (Horizontal)MAXIMUM

(Dimensions in inches)12 120(10ft) 186(15ft,6in)24 120(10ft) 186(15ft,6in)36 120(10ft) 186(15ft,6in)48 120(10ft) 186(15ft,6in)

*Maximumhorizontalrunis100%ofvertical,butcannotexceed17 feet.

Figure 54

Page 32: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 32

VERTICAL TERMINATIONLocate and mark the center point of the vent pipe using a nail on theundersideoftheroof.Drivethenailthroughthecenterpoint.Mark the outline of the roof hole around this center point.NOTICE:Sizeoftheroofholedimensionsdependonthepitch

oftheroof.Theremustbea1inch(25mm)clearancetotheverticalpipesections.Thisclearanceistoallcombustible material.

Cover the opening of the vent pipe and cut and frame the roof hole.Useframinglumberthesamesizeastheroofraftersandinstall the frame securely. Flashing anchored to frame must withstandhighwinds.Thestormcollarisplacedoverthisjointtomakeawater-tightseal.Non-hardeningsealantshouldbeusedtocompletelysealthisflashinginstallation.

Determining Minimum Vent Height Above the Roof.

WARNINGMajor U.S. building codes specify minimum chimney and/or vent height above the roof top. These minimum heights are necessary in the interest of safety. These specifications are summarized in Figure 55.

VENT CAP

GAS VENT

24”

24”

MORETHAN

10 FEET

Figure 55

Notethatforsteeproofpitches,theventheightmustbeincreased. In high wind conditions, nearby trees, adjoining roof lines, steep pitched roofs, and other similar factors can result in poor draft, or down-drafting. In these cases, increasing the vent height may solve this problem.

Installing the Vent System in a ChaseA chase is a vertical box-like structure built to enclose the gas fireplaceand/oritsventsystem.Verticalventrunsontheoutsideof a building may be, but are not required to be installed inside a chase.

CAUTIONTreatment of firestop spacers and construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Check local building codes to determine the requirements for these steps.

NOTICE: Build the chase large enough to maintain the minimum clearanceofcombustiblematerials(includinginsulation)tothevent system. When installing the vent system in a chase, insulate thechaseasyouwouldtheoutsidewallsofyourhome.Thisisespeciallyimportantincoldclimates.Uponcompletionofchaseframing, install the vent system by following the instructions in this manual.Theverticalterminationcapforthisfireplacemustnotbeanycloser than 24-in. to combustible materials. See Figure 53.

40’(12.19M)

MAX

24” MINIMUMCLEARANCE TOCOMBUSTIBLES

NATURAL ORMAN MADE

8’ (2.44M)MAX

8’ (2.44M)MAX

45°

45°

Figure 56

If two vertical terminations are run near each other, they may be placed a minimum of 12 inches between them if they are at the same height. See Figure 54. If two vent terminations are not at the same height, they must be positioned at least 24 inches apart tominimizedraftissuesbetweenthem.

12”MINIMUM

Figure 57

Page 33: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 33

Vertical Through-the-Roof ApplicationsYourGasFireplacehasbeenapprovedfor:a) Verticalinstallationsupto40feetinheight.b) Twosetsof45degreeelbowoffsetswithinthesevertical

installations. From 0 to a maximum of 8 ft. a vent pipe can be used between elbows.

c) Wallstrapsmustbeusedtosupportoffsetpipeevery4’.Thisapplicationwillrequirethatyoufirstdeterminetheroofpitchand use the appropriate venting components.OFFSET CHART

RISE

OFFSET

SIZE 5-in X 8-in

ELBOWDEGREES

CHIMNEYSECTION

OFFSETINCHES

RISEINCHES

(Dimensions in Inches)45° 0 5-5/8 15-3/845° 6 8-7/8 18-3/845° 9 10-7/8 20-5/845° 12 13 22-5/845° 24 21-3/8 31-1/845° 36 29-7/8 39-3/845° 48 38-1/4 47-7/8

Figure 58

General MaintenanceInspect venting system semi-annually as follows:1. Check for corrosion areas of the venting system exposed

totheelements.Thesewillappearasrustspotsorstreaksand, in extreme cases, holes. Replace damaged components should immediately.

2. Removethecapandshineaflashlightdownthevent.Remove any bird nests or other foreign material.

3. Check for evidence of excessive condensate, such as water droplets forming in the inner liner and subsequently dripping out at joints. Condensate can cause corrosion of caps, pipe andfittings.Itmaybecausedbyhavingexcessivelateralruns, too many elbows and exterior portions of the system being exposed to cold weather.

4. Inspectjointstoverifythatnopipesectionsorfittingshavebeen disturbed and, consequently, loosened. Also, check mechanicalsupports,suchaswallstrapsorplumbers’tapefor rigidity.

Venting termination shall not be recessed into a wall or siding.A removable panel or other means must be provided in the enclosureforvisualinspectionoftheflueconnection.NOTICE:Thisalsopertainstoverticalventsystemsinstalledonthe outside of the building.Slidetheverticalventcapovertheendsoftheventpipeandsecure. See Figure 59.

Figure 59

VERTICAL TERMINATION (CONT’D)

Page 34: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 34

DVVK-5F FLEX VENT INSTRUCTIONSTheDVVK-5F FLEX VENT KIT includes the following components:• (1)HorizontalTerminationCap• (1)4-footsectionofFlexventwithspacers(5-inchflue/

8-inchouterpipe)withflueadaptercollar• (1)WallFirestop/ThimbleAssembly• Hardwarepackthatincludesbandclampsandscrews

Maintain at least 1/2-inch rise for every 12 inches of vent run.

CAUTION• Because of sharp edges, always use gloves when

handling the flex vent components.• Always follow the general venting requirements for

vent terminal location, vent lengths, and clearance to combustible materials.

• Always stretch and secure venting with wire or metal strapping to ensure that the horizontal runs do not sag.

• Vent connections should overlap a minimum of 1 inch for proper sealing.

NOTE: For installation of Flex Venting on Fireplaces that have FlueandInletVentcollarsflushwithtopofthefireplace,itisrecommendedthatanSD58DVA-FCFConnectorbeused.WhenusingtheSD58DVA-FCFFlexVentConnector,itwillrequireremoving(orcuttingoff)the5"diameteradapterfromtheDVVK5FFlexFlue.See Step 10b and Figure 62b. INSTALLATION1. Unpackventcomponentsandcheckthatallitemsareincluded.

2. Check to see that the vent spacer springs are located around theflueventat8inchintervalsalongitslength.See Figures 60 and 61. If not, stretch the spacer springs to about 15 inches longandwrapthemaroundtheflue,theninterlocktheendsofeach spring. Maintain equal distance between spring spacers.

Figure 60

5” FLEXVENT PIPE

SPACERSPRING

8” FLEXVENT PIPE

Figure 61

3. Attach a 6-inch piece of hard pipe to raise the connection pointabovethefireplace.

4. Useexisting8-inchdiameterinletcollartoattachouterventpipe.

5. InstalltheWallFirestop/Thimbleassemblyasrequiredthrough the wall. Refer to the venting charts in the fireplace manualtodeterminetheproperheightandsizeoftheventopening.Theminimumopeningshouldbe10-incheswideby12-incheshigh.Theminimumcombustibleclearancefromthehorizontalventis1inchfromsidesandbottom,and3inches above the vent pipe.

6. In most cases, after determining the length of the vent that is needed, it may be easier to install the flue and outer vent pipestotheTerminationCapfirst,thenfromtheoutside,feed the venting through the wall to the fireplace.

7. If the venting is to long, trim off any excess vent before attaching the vent end connectors.

8. AttachtheTerminationCaptotheoutsideofthehouse.

CAUTIONDo not use force when installing the Horizontal Vent Termination into the flex venting. Always stretch venting out first, then cut off excess vent material prior to sliding the vent termination into the flue and inlet venting. Forcing the termination cap into the flex venting will deform the flue venting, which will restrict the exhaust gases, and cause improper operation of the fireplace.

Page 35: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 35

DVVK-5F FLEX VENT INSTRUCTIONS (CONT’D)9. Prior to making the vent connections, apply high temperature

sealant(1000°Fmin.)totheventconnectionsbeforesecuringwiththebandclampsprovided.Note:thefluepipeendwithouttheadapteristobeinstalledtotheTerminationCap.

NOTE: For installation of Flex Venting on Fireplaces that have FlueandInletVentcollarsflushwithtopofthefireplace,itisrecommendedthatanSD58DVA-FCFConnectorbeused.WhenusingtheSD58DVA-FCFFlexVentConnector,itwillrequireremoving(orcuttingoff)the5"diameteradapterfromtheDVVK5FFlexFlue.See Step 10b and Figure 62b.10a. Applysealanttotheoutsideofthefluepipeadapterand

connecttotheflexfluepipe.Theninserttheadapterintothefireplaceflue.Securetheflueadaptertothefireplacefluewith a minimum of two screws provided. See Figure 62b.Or.....

10b.IfusingtheSD58DVA-FCFVentConnector,applysealanttotheinsideofthe5"diameterflexfluepipe,thenconnecttheflexfluetothe5"fluetakeoffontheSD58DVA-FCFConnector.Usea5"diameterbandclampandaminimumoftwoscrewstosecuretheflexfluetotheSD58DVA-FCFConnector. See Figure 62b.

11. Attach the Outer Vent pipe to the 8-inch diameter collar on thefireplacewithalargebandclampprovided.Sealantmayalso be used on the outer vent connections.

12. Check all vent connections for tightness. Make sure horizontalventinghastheproperriseandcombustibleclearances required. Refer to venting charts in fireplace instruction manual.

8” DIAMETER FLEXVENT PIPE

5” DIAMETER FLEXFLUE PIPE

5” DIAMETERFLUE ADAPTORCOLLAR

8” DIAMETERFIREPLACEINLET COLLAR

Figure 62a

Figure 62b

Figure 63

Page 36: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 36

FRAMING AND FINISHINGInstalling Support BracketsInstallahorizontalpipesupportusedforeach3feetofhorizontalrun to framing members. Allow 3 inch clearance to combustibles above 8-inch diameter pipe and elbows, and 1 inch clearance to both sides and bottom.Supportverticalrunsofthisventsystemsevery4feetusingwallbrackets attached to the vent pipe, then secured with nails or screws to structural framing.

Figure 64

Installing FirestopsFirestops are required for safety whenever the vent system passes throughaninteriorwall,anexteriorwall,oraceiling.Thesefirestopsactasafirebreakheatshieldandasameanstoinsurethat minimum clearances are maintained to the vent system.

Horizontal FirestopsHorizontalrunsintheventsystemwhichpassthrougheitherinteriororexteriorwalls,requiretheuseofwallfirestopsonbothsides of the wall through which the vent passes.Positionthefirestopsonbothsidesoftheframedhole,previouslycut.Athimblespacerisincludedwiththefireplace,andmustbeinstalledundertheinsidewallfirestopthimblebase.See Figure 65.Securefirestopwithnailsorscrews.Continuetheventrunthroughthefirestops.

13”

10 5/8”

WALL FIRESTOP

THIMBLE SPACER(INCLUDED WITH FIREPLACE)

Figure 65

Page 37: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 37

FRAMING AND FINISHING (CONT’D)Vertical FirestopsVertical runs of this system which pass through ceilings require theuseofONEceilingfirestopattheholeineachceilingthroughwhich the vent passes.Position a plumb bob directly over the center of the vertical vent component and mark the ceiling to establish the center point ofthevent.Drillaholeordriveanailthroughthiscenterpointandchecktheflooraboveforanyobstructionssuchaswiringorplumbingruns.Repositionthefireplaceandventsystem,ifnecessary,toaccommodateceilingjoistsand/orobstructions.Cuta10-5/8inchx10-5/8inchholethroughtheceiling,usingthe center point previously marked. Frame the hole with framing lumberthesamesizeastheceilingjoists.See Figure 66. If theareaabovetheceilingisNOTanattic,positionandsecuretheceilingfirestopontheceilingsideofthepreviouslycutandframed hole. See Figure 67. If the area above the ceiling is an attic, position and secure the firestopontopofthepreviouslyframedhole.See Figure 68.NOTICE: Remove insulation from the framed area in the attic beforeinstallingthefirestopand/orventpipes.

Figure 66

Figure 67

Figure 68FinishingFinish the walls with the material of your choice. Figure 12 on page 12 shows the minimum vertical and corresponding maximumhorizontaldimensionsofmantelsorothercombustibleprojectionsabovethetopfrontedgeofthefireplace.Only non-combustible materials may be used to cover the black fireplacefront.

WARNINGWhen finishing the fireplace never obstruct or modify the air inlet/outlet louvers in any manner. Provide adequate clearances around air openings into the combustion chamber.

CAUTIONIf the joints between the finished wall and the fireplace surround (top and sides) are sealed, a 300 Degree F minimum sealant material must be used. These joints are not required to be sealed. Only non-combustible material (using 300 Degree F minimum adhesive if needed), can be applied as facing to the fireplace surround.

Page 38: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 38

LINER INSTALLATIONNOTICE: A liner is required for operation of this fireplace. Refer to the instructions that came with your liner for proper installation.

DVP72LPZ - Bronze Ridgeback Liner Kit

Figure 69

DVP72LKR - Black Glass Liner Kit

Figure 70

Page 39: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

DECORATIVE GLASS PLACEMENT

38217-5-0818 Page 39

Preparation of fireplace prior to decorative glass placement1. DVLL72BP: RemovetheBarrierScreenandGlassDoor

Assembly.

CAUTIONTurn off all power to the fireplace prior to installing liners or servicing the controls.

2. Ifalinerkithasnotbeeninstalled,STOPandinstallonebefore proceeding with media placement. A liner is required.

3. If applicable, install one of the optional log sets.

4. Add the decorative crushed glass media of your choice at this time. Crushed glass may cover the complete burner and burner screen.

NOTICE: Clear crushed glass is recommended on the screen cover toallowtheLEDlightingtoshinethroughtheglass.Othercrushedglass colors can be used over the burner, or sprinkled with clear glass to accent as desired.

Place crushed glass media over the burner and burner screen in asinglelayer.Usejustenoughcrushedglassmediatomasktheburnerandburnerscreen(6Sq.Ft.minimum).See Figure 71. NOTICE: OnthePropaneGasburner,anextralayerortwoofcrushedglassontopoftheburnermaybeappliedtosoftentheflames.Do not use excessive amounts of crushed glass or sooting may occur.NOTICE: 1/4" crushed glass media is required on the burnerand the burner screen. Do not place crushed glass in the pilot recessed area.

Figure 71

CRUSHED GLASSMEDIA REQUIRED

CAUTION:PLACE CRUSHED

GLASS MEDIA IN THE RECESSEDAREA AROUND THE PILOT, PILOTSENSOR, OR IGNITOR PROBE

DO NOTCAUTION:DONOTPLACECRUSHEDGLASSMEDIAINTHERECESSEDAREAAROUNDTHEPILOT,PILOTSENSOR,ORIGNITORPROBE

CRUSHEDGLASSMEDIAREQUIRED

Page 40: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 40

MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS

TECHNICAL DATARemote Control

Supplyvoltage 4.5V(three1.5VAAAbatteries)Ambient temperature ratings 0-50°C(32-122°F)

Radio frequency 315MHz

WARNINGThe transmitter and receiver are radio frequency devices. Placing the receiver in or near metal may severely reduce the signal range.

WARNINGTurn off the main gas supply and electrical supply to the fireplace during installation and/or maintenance of the receiver device.

WARNINGFIRE HAZARD. Can cause severe injury or death. The receiver causes ignition of the fireplace. The fireplace can turn on suddenly. Keep away from the fireplace burner when operating the remote system or activating manual bypass of the remote system.

CAUTIONPROPERTY DAMAGE HAZARD.Excessive heat can cause property damage. The fireplace can stay lit for many hours. Turn off the fireplace if it is not going to be attended for any length of time. Always place the Transmitter where children can not reach it.

Figure 72

Figure 73

NOTICE:Notallfeaturescalledoutinthediagramaboveareavailableonthisfireplace.NOTICE:ThiscontrolsystemincludesaBatteryBack-uppackthatallows the Fireplace to operate in the event of a power outage.NOTICE:TheAccentLightand/orBlowerfeatureswillnotoperate during a power outage.NOTICE: Replace all Batteries at least once each year, preferably before at the beginning of the season.

CAUTIONFIRE OR EXPLOSION HAZARD. Can cause property damage, sever injury or death. Do not attempt to take apart the gas control or to clean it. Improper assembly and cleaning can cause unreliable operation.

Page 41: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 41

MULTIFUNCTION REMOTE OPERATING INSTRUCTIONSInitializing the System for the First Time1. Remove the wall cover. Open the wall mounted battery back-up holder. See Figure 74. Install the four AA batteries

into the wall mounted battery back-up holder then reinstall the cover. See Figure 75.

2. Install three AAA batteries into the battery bay located on the base of the transmitter. See Figure 76.

3. SetthewallremoteslideswitchtotheREMOTEposition.See Figure 75.

4. PressandreleasetheSWIbuttononthewallcontrolwitha paper clip and the IFC module will beep three times to indicatetheIFCmoduleisreadytosynchronizewiththetransmitter within ten seconds. See Figure 75.

Figure 74

SWIBUTTON

Figure 75

5. WiththebatteriesalreadyinstalledintheTransmitter,pushtheONbutton.TheReceiverwillbeepfourtimestoindicatetheTransmitter’scommandisacceptedandsetstothematchingcodeofthatTransmitter.Thesystemisnowinitialized.

Figure 76

Temperature Indication Display °C or °FWiththesystemintheOFFposition,presstheThermostatButtonandtheModeButtonatthesametime.LookattheLCDscreenontheTransmittertoverifythata°Cor°FisvisibletotherightoftheRoomTemperaturedisplay.See Figures 77 and 78.

Figure 77

Figure 78

Page 42: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 42

Turn On the FireplaceWiththesystemOFF,presstheON/OFFButtonontheTransmitter.TheTransmitterdisplaywillshowsomeotheractiveIcons on the screen. At the same time the Receiver will activate thefireplace.AsinglebeepfromtheReceiverwillconfirmreception of the command.

Turn OFF the FireplaceWiththesystemON,presstheON/OFFButtonontheTransmitter.TheTransmitterLCDdisplaywillonlyshowtheroomtemperature. See Figure 79. At the same time the Receiver will turnoffthefireplace.AsinglebeepfromtheReceiverconfirmsreception of the command.

Remote Control Display - Figure 79

Remote Flame ControlTheProflamecontrolhassixflamelevels.Withthesystemon,andtheflamelevelatmaximum,eachpresstheDownArrowButtononcewillreducetheflameheightbyonestep–untiltheflameisturnedoff.TheUpArrowButtonwillincreasetheflameheighteachtimeitispressed.IfyoupresstheUpArrowButtonwhilethesystemisonbuttheflameisoff,theflamewillcomeoninthehighposition.See Figures 80 through 83.Asinglebeepwillconfirmreceptionof the command.

OFF

Flame Off - Figure 80

MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS

OFF

Flame Level 1 - Figure 81

OFF

Flame Level 5 - Figure 82

OFF

Flame Level Maximum - Figure 83

Page 43: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 43

MULTIFUNCTION REMOTE OPERATING INSTRUCTIONSRoom Thermostat (Transmitter Operation)TheRemoteControlcanoperateasaroomthermostat.Thethermostat can be set to a desired temperature to control thecomfortlevelinaroom.Toactivatethisfunction,presstheThermostatButtonFigure 73.TheLCDdisplayontheTransmitterwillchangetoshowthattheroomthermostatisONand the set temperature is now displayed. See Figure 84.Toadjustthesettemperature,presstheUporDownArrowButtonsuntilthedesiredsettemperatureisdisplayedontheLCDscreenoftheTransmitter.See Figure 85.

Figure 84

Figure 85

Smart Thermostat (Transmitter Operation)TheSmartThermostatfunctionadjuststheflameheightinaccordance to the difference between the set point temperature and the actual room temperatures. As the room temperature gets closertothesetpointtheSmartFunctionwillmodulatetheflamedown.Toactivatethisfunction,presstheThermostatButtonuntilthewordSMARTappearstotherightofthetemperaturebulbgraphic. See Figure 86.Toadjustthesettemperature,presstheUporDownArrowButtonsuntilthedesiredsettemperatureisdisplayedontheLCDscreenoftheTransmitter.See Figure 87.NOTICE:WhenSmartThermostatisactivated,manualflameheight adjustment is disabled.

Figure 86

Figure 87

Manual ON/OFF (Transmitter Operation)TheThermostatFeaturemaybedisabledsothefireplacewilloperate only in manual mode. Withall(3)AAAtypebatteriesinstalled:1. TakeoutoneAAAbattery.2. While re-inserting the battery, push and hold down the

thermostatbutton.Thiswilldisablethethermostatfeatureonthe transmitter.

Page 44: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 44

Blower ControlIfthefireplaceisequippedwithablowerassembly,thefanspeedcanbecontrolledbytheProflameremote.Thefancanbeadjustedthroughsixspeeds.Toactivatethisfunction,usetheModeButtonFigure 71 to index the fan control icon. See Figure 88.UsetheUp/DownArrowButtonsFigure 71 to adjust the fan speed. See Figure 89.Asinglebeepwillconfirmreceptionofthecommand.

OFF

Figure 88

OFF

Figure 89

Remote Dimmer Control (Light) — Not applicable on DVLL72BP Models.Split Flow Control (Option not available for the DVLL72BP Series Fireplaces)

MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS

Page 45: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 45

MULTIFUNCTION REMOTE OPERATING INSTRUCTIONSDuring aprolongedpoweroutage,thefireplacecanoperateinContinuousPilotMode.Thisreducesdrainonthebatteriesusedtoignitetheburnerandensuresthefireplacewillcontinuetooperate throughout the outage.

Continuous Pilot/Intermittent Pilot (CPI/IPI) SelectionWith the system in OFF position press the Mode Button Figure 70 to index to the CPI mode icon. See Figures 90 and 91.PressingtheUpArrowButtonwillactivatetheCPI.PressingtheDownArrowButtonwillreturntoIPI.Asinglebeepwillconfirmthe reception of the command.

OFF

Figure 90

OFF

Figure 91

Button LockThisfunctionwilllocktheButtonstopreventunsupervisedoperation.Toactivatethisfunction,presstheMODEandUPButtonsatthesame time. See Figure 92.Todeactivatethisfunction,presstheMODEandUPButtonsatthe same time.

OFF

Figure 92

Low Battery Power Detection - TransmitterThelifespanoftheremotecontrolbatteriesdependsonvarious factors: • Quality of the batteries• HowfrequentlythefireplacecyclesonandoffWhen the transmitter batteries are low, an Icon will appear on the LCDdisplayofthetransmitter.See Figure 93 before all battery power is lost. When the batteries are replaced this Icon will disappear.

OFF

Figure 93

Page 46: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 46

MULTIFUNCTION REMOTE OPERATING INSTRUCTIONSLockout State DefinitionTopreventdamagetothefireplace,IFCboardwillautomaticallylockouttheremotecontrolifitdetectsaanomalousflameortoomanyunsuccessfulignitionattempts.Thelockoutstatewillremain as long as the power supplies are applied.When the IFC board goes into lockout state:1. both the Pilot and the Main Burner solenoids in the gas valve

arede-energized;2. adiagnosticcodeissentthroughthediagnosticredLED.3. the IFC board will ignore any burner ignition command

and remain in the OFF state unless the unlock command sequence is met.

Turnthesystempowersupplies(tothewallcontrolorremotecontrol)OFFfortwoorthreesecondsandthenrestorepower.Ifthelockoutreoccurs,callyourdealer.Thecausesoflockoutmust be investigated under safe conditions by trained service personnel.

Using the Fireplace without a Remote ControlThefireplacecanbeturnedON(HIonly)andOFFwiththewallswitch.ThefireplaceflameON/OFFistheonlyfunctionthatwilloperate;noflameadjustment,lightorblowerwillworkwhenusingthewallswitch.ThewallcontrolswitchshouldbeturnedOFFwhenthefireplaceisnotbeingusedforextendedperiodsoftime.

Battery Backup OperationInstallbatteries(Seeinitializationsequenceonpage41).Incaseofpowerloss,thefireplacewillswitchtobatterymodeautomatically.Thefireplacewilloperatenormallywithoutthefanor light control when in battery mode.

Low Battery DetectionWhen the backup batteries are low, the module emits a double-beepwhenitreceivesanon/offcommand.Thesystemwill not accept any commands until the batteries are replaced or A/Cpowerisrestored.

Page 47: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 47

1. Turnoffallelectricpowertotheapplianceifserviceistobeperformed(ifapplicable).

2. Turngasshut-offvalveto“OFF” position.

TO TURN OFF GAS TO FIREPLACE

SHUT-OFF VALVE

1. STOP!Readthesafetyinformationabove.2. TurnOFFelectricpowertotheappliance.3. Remove front surround panel assembly or bottom louver if

included.4. Turngasshut-offvalvecounterclockwise to “On”

position.5. Waittenminutestoclearoutanygas.Thensmellforgas,

includingnearthefloor.Ifyousmellgas,STOP!Follow“B” in the safety information above on this page. If you do not smell gas, go to the next step.

6. TurnONelectricpowertotheappliance.7. Findpilot-Followmetaltubefromgascontrol.Thepilotis

behind the burner on the right side.8. Turnmainflametoon.Ifthepilotdoesnotlightwithin60

seconds,stopandgotoStep5.9. If the burner or pilot does not operate properly after several

tries, turn the gas shut-off valve clockwise to “OFF” and call your service technician or gas supplier.

10. Replace the front surround assembly or close bottom louver assembly(ifapplicable).

11. Operationofthegasvalveiscontrolledbyamanualon/off switch or a hand held remote control. Refer to remote instructions for detailed operation information.

LIGHTING INSTRUCTIONS

A.Thisappliancehasapilotwhichcanbelitwiththemanualon/offswitch,aremotecontrol,orbyswitchingtheremotereceiverswitchtothe“ON”position.Whenlightingthepilot,follow these instructions exactly.

B. Before lighting smell all around the appliance area for gas. Besuretosmellnexttothefloorbecausesomegasisheavierthanairandwillsettleonthefloor.

WhatToDoIfYouSmellGas• Donottrytolightanyappliance.• Donottouchanyelectricalswitch;• Donotuseanyphoneinyourbuilding.• Immediatelycallyourgassupplierfromaneighbor's

phone.Followthegassupplier'sinstructions.• Ifyoucannotreachyourgassupplier,callthefire

department.

C.Useonlytheremotecontrolormanualremotereceiverswitchtooperatethegasvalve.Neverusetools.Ifvalvedoesnotoperate,don’ttrytorepairit,callaqualifiedservicetechnician.Forceorattemptedrepairmayresultinafireorexplosion.

D.Donotusethisapplianceifanyparthasbeenunderwater.Immediatelycallaqualifiedservicetechniciantoinspecttheappliance and to replace any part of the control system and any gas control which has been under water.

FOR YOUR SAFETY READ BEFORE LIGHTING

INTERMITTENT PILOT LIGHTING INSTRUCTIONS

WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Page 48: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 48

CONTROL SYSTEM TROUBLESHOOTINGPROBLEM OBSERVED POSSIBLE CAUSE CORRECTIVE MEASURE

Gasodorduringsetup GasLeak

WHAT TO DO IF YOU SMELL GASDo not try to light any appliance.Do not touch any electrical switch; do not use any phone in your building.Leave the building immediately.Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.If you cannot reach your gas supplier, call the fire department.

Gasodorbeforefirstignition GasLeak

Fireplace is “on”butnoflameandpilotisnot trying to light

GasLineValveturned“off” Turnshutoffvalveto“open” positionControl module in “lockout” Turnfireplace“off” and then back “on”

Pilot continues to spark when pilot is lit.

Notenoughgastopilot WaitforpilotflametostrengthenLowGasPressure Checkpressures.Seepage17.Pilotigniter/sensorisdirty Clean pilot. Pilot not grounded well Check ground connectionsDraftinfirebox Vent restrictor not installedPilot sensor has been bent Replace pilot

Pilot will not ignite, or will not stay lit

Pilotigniter/sensorisdirty Cleanflamesensorandpilotigniter.Pilot not grounded well Check ground connectionsSensorWireloose Check sensor wire terminalsGaspressureincorrect Adjust gas pressurePilotGasLinebentorkinked Replace pilot tubeFaultypilot,Sensorbent Replace PilotFaulty valve Replace Valve

Burner takes too long to fully light

Low gas pressure Check gas supply pressureCloggedordirtycarryover/burnerports Clean portsBlockedorifice CheckorificeopeningFaulty valve Replace valve

Burner does not light but pilot remains on

Low gas pressure Check gas supply pressureClogged or dirty burner ports Clean burner portsBlockedorifice CheckorificeopeningLoose wire connections Checkvalve/controlmoduleconnectionsFaulty pilot Replace pilotFaulty valve Replace valve

Burner lights but does not stay lit while pilot remains on

Low gas pressure Check gas supply pressureLoose sensor wire Check wire connectionFaulty valve Replace valveFaulty pilot or thermocouple ReplaceSafetypilotClogged or dirty burner ports Clean burner ports

(Forfireplaceequippedwithoptionalther-mostatorthermostatremote)Roomtem-perature is higher than thermostat setting

Move(optional)remoteawayfromfire-placeSethighertemperatureon(Optional)remote/thermostat

(Optional)Remotecontrolbatteriesfailing Replace batteries in remote transmitter and receiver

Page 49: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 49

CONTROL SYSTEM TROUBLESHOOTING (CONT’D)PROBLEM OBSERVED POSSIBLE CAUSE CORRECTIVE MEASURE

Burner & pilot light but will not stay lit

Flame sensor dirty Clean pilot sensorLow gas pressure Check gas supply pressureNotenoughfreshairforpilot Open door or window - ventilateClogged or dirty burner ports Clean burner ports

(Forfireplaceequippedwithoptionalther-mostatorthermostatremote)Roomtem-perature is higher than thermostat setting

Move(optional)remoteawayfromfire-placeSethighertemperatureon(Optional)remote/thermostat

(Optional)Remotecontrolbatteriesfailing Replace batteries in remote transmitter and receiver

Faulty pilot or thermocouple Replace pilot

Incorrectburnerflame

Incorrect gas supply or pressure Check gas supply pressureBlockedorifice CheckorificeopeningClogged or dirty burner ports Clean burner portsFaulty valve Replace valveHighaltitude Adjustorificesizeforaltitude

BackfireofburnerBlockedorifice CheckorificeopeningClogged or dirty burner ports Clean burner portsLow gas pressure Check gas supply pressure

Fireplace produces unwanted odorsVapors from paint, hairspray, glue, etc. Ventilateroomuntilodorstops.Donotuse

paint,hairspray,glue,etcaroundfireplaceInitial burn-off of manufacturing chemicals Ventilate room until odor stops

Whistlenoisefromfireplace

Check gas pressure Adjust gas pressure to recommended setting.

Air in gas line Bleed linesControl knob not in fully open position Open control knob to full positionSpiralgasflexlinepinchedortoosmalldiameter line

Straightenflexlinewherepinchedorre-place gas feed line with larger diameter

Page 50: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 50

PARTS LISTINDEX

NO. DVLL72 DESCRIPTION

1 30975 Flue Outlet Assembly2 M170 Gasket,FlueOutlet3 R7567 Inlet Vent Adaptor - 8 inch4 R7573 Gasket-InletVent5 38183 TopCover6 R12469 TopInsulation-(RT/LT)(Qty.2)7 38184 TopHeaderShield(Qty.2)8 R11963 Insulation,Top(Center)(Qty.2)9 38182 Rear Access Plate

10 38207 Screen,BurnerCover11 38204 RearBaffleBracket12 38286 Burner Assembly Weldment13 R12471 Glass,FireboxBottom14 38208 BurnerSupportBracket(Qty.2)15 38318 LEDReflectorAssembly16 38287 Light Limiter Bracket17 R12437 LEDLightStrip(Qty.2)18 R12294 LEDSwitchWireHarness(14ft.)19 R12284 LEDControlModule20 R11920 LEDTransformer21 38185 TopStandoff(Qty.4)22 38180 HangerBracket(Qty.2)23 34360 Handle(Qty.2)24 34418 Control Cover - Inner25 R12085 Gasket,ControlPlate26 34419 Control Plate27 37092 Valve Bracket28 R11233 Valve-Natural29 R11234 Valve - Propane29 27730 Junction Box Mount Bracket30 35530 Bracket-GasLineSeal31 R3490 Junction Box32 R12383 ControlModule,ProflameII33 28450 NailingFlange(Qty.4)34 35978 DoorLatchTool

35 R12283 Pilot-Natural35 R12283 Pilot - Propane36 38211 Pilot Bracket37 R11977 Gasket-Venturi38 R11978 VenturiTube-90Degree39 38210 BurnerHold-DownBracket(Qty.2)40 R10915 OrificeHolder-Flexline41 R7624 AirShutter42 38205 GlassRetainer43 Q0041 BarrierScreen44 38196 ScreenFrameBracket45 38195 ScreenFrame46 38281 BarrierAssembly-Complete(43-45)47 38320 GlassFrameAssembly48 38292 Board,Non-Combustible(Top)49 38291 Board,Non-Combustible(Qty.2))50 R11584 Wall Control With Battery Back-up51 36827 Bracket-LEDButtons52 R12296 Wall Plate53 R11921 SwitchButton-LED(Qty.2)54 R12295 Wall Box BracketNS R8902 Stud,Spherical(Qty.6)NS R8866 Nut,6mmStainlessSteel(Qty.6)NS 33331 ThimbleSpacerNS R11524 WireHarness,ControlModuleNS P283 Orifice#26-NaturalNS P316 Orifice-2.15mm-PropaneNS R11522 RemoteTransmitter

NS R1155210ft.ExtensionWireHarness(ControlModuletoWallBox)

NS R10882 Fitting,Inlet90(Qty.2)NS 37094 Outer Access PanelNS 38348 DoorLimiterBracketNS R12467 Glass,LEDNS R10915 Flex Line, 18 inch

NS-NotShown

INDEX NO. DVLL72 DESCRIPTION

Page 51: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 51

LED COMPONENTS WALL CONTROL COMPONENTS

12

34

5

6

7

21

22

23

25

24

26

27 28

293031

32

33

42

3837

3635

34

39 40

46

49

48

47

45

44

43

9

10

11

12

13

14

15

16

49

18

19

20

50

5453

51

52

1717

8

41

PARTS VIEW

WARNINGFailure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in property damage or personal injury.

Page 52: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 52

COMPONENT WIRING DIAGRAM

Ifanyoftheoriginalwireassuppliedwiththisfireplacemustbe replaced, it must be replaced with equivalent gauge and temperature rated wire.

Thisfireplaceisonlyforusewiththetypeofgasindicatedontherating plate and may be installed in an aftermarket, permanently located,manufactured (mobile)homewherenotprohibitedbylocalcodes.Thisfireplaceisnotconvertibleforusewithothergases,unlessacertifiedkitisused.

WARNINGElectrical Grounding Instructions

This fireplace is equipped with a three-prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

CAUTIONLabel all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

CAUTIONDo not operate the fireplace with glass panel removed, cracked or broken. Replacement of the panel should be done by a licensed qualified service person.

WARNINGImproper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Verify proper operation after servicing.

NL

COMBUSTION

BLOWER

ORANGE

PILOT

GAS CONTROL VALVE

ORANGEGREEN

YELLOW

WHITEOR

BLACK

BLACKWHITE

BLOWER

FU

SE

BLACKWHITE

GREEN

POWER CORD

TO JUNCTION

BOX

AUX.

LOOP

SLE

EV

E

USER INTERFACE/

BATTERY HOLDER

ORANGE

WHITE

YELLOW

RED

BLACK

BLACK

BLACK

REDBLACK

LED STRIP

LED STRIP

TRANSFORMER

CO

NT

RO

LM

OD

UL

E

BLACK

BLACK

BLACK

BUTTONBRIGHTNESS - TOP

BUTTONMODE - BOTTOM

JUNCTION BOX

Page 53: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 53

MAINTENANCE AND SERVICEMAINTENANCE AND SERVICERemoving the Barrier ScreenLiftthebarrierupapproximately1/4inchwithonehandunderthelowerbarrierframeedgetodisengagethelowerflange.Graspthe top of the barrier and pull forward to disengage it. Remove the barrier by pulling straight forward.

Remove Door Limiter BracketBeforetheGlassDoorcanberemoved,aDoorLimiterBracketmustberemoved.Usinga5/16-inchhexnutdriver,remove(5)#10-24x3/8-inchscrewsthatretaintheLimiterBrackettothebottomflangeoftheGlassDoorframe,andsetthebracketaside.See Figures 94 and 95.NOTICE: TheDoorLimiterBracketmustbere-installedtotheGlassDoorframepriortooperationofthefireplace.

DOOR LIMITER BRACKET

GLASS DOOR FRAME

Figure 94GLASS DOOR FRAME

DOOR LIMITER BRACKET

SCREW (5)

FRONTOF

FIREPLACE

Figure 95Removing the Glass Door AssemblyLocatetheglassdoortool(securedtothetopofthefireplaceforshipping).Usethetoolasalevertoreleasethebottomoftheglass door as shown in Figure 96.

GLASS DOOR REMOVAL TOOL

PLACE SMALL 90° END OF THEGLASS DOOR REMOVAL TOOLBEHIND THE BOTTOM DOORFLANGE, THEN MOVE TOOLSIDEWAYS TO DISENGAGETHE RETAINER CLIPS

Figure 96

NOTICE:Theglassdoorissecuredtothetopofthefireboxwithtabsthatallowittopivotoutwardatthebottom.Thebottomofthedoor frame engages into the four bullet type retainers.

Pivot the glass door out until the bottom of the door is about 6 to8inchesfromthefireboxface,thenliftupwardonthedoorassembly to disengage the top of the door from the tab retainers ontopofthefirebox.See Figures 97 and 98.

CAUTIONThe glass door is wide and heavy and can be difficult to install or remove by a single person. It is recommended that two people remove the glass door.

LIFT UP TO RELEASEFROM TABS

TABS

1

2

FIREPLACE FACE

PIVOT OUT

GLASS DOOR ASSEMBLY

Figure 97

PIVOTOUT

TABS

2 LIFT UP TORELEASE OFF

THE TABS

GLASS DOORASSEMBLY

FIREPLACEFACE

1

Figure 98

GLASSDOORFRAME

DOORLIMITERBRACKET

Page 54: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 54

MAINTENANCE AND SERVICE (CONT’D)WIRINGIf any of the original wire supplied with this unit must be replaced, itmustbereplacewith18GA.150°Cwireoritsequivalent.

GAS VALVE AND CONTROL ACCESS INSTRUCTIONS

CAUTIONSharp Edges! Use gloves and eye protection when servic-ing the fireplace controls.

NOTICE: To service or inspect the gas valve and control system after the fireplace has been installed, or if there is no right side outer accessibility, follow these steps for servicing the fireplace gas control valve.Accessing the Gas ValveAlwaysturnoffgasandelectricalsupplytothefireplacebeforeservicing the controls.1. Remove the barrier screen and glass door assemblies and

set them aside in a safe location.2. It is not necessary to remove decorative glass media from

the burner to gain access to the valve compartment.3. Removal of crushed glass away from the access door and

liners is recommended prior to the removal of the liner or liner panels.

4. Remove logs and rock kit if applicable.5. Removelinerpanel(s)ifinstalled,togainaccesstothevalve

compartment.6. Refer to the instructions included with the accessory kits for

removal and installation.7. Removethetwelve5/16-inchhex-headscrewsthatsecure

theaccesscoverplateontherightsideofthefirebox.See Figure 99.

Figure 99

8. Thegasvalveisnowaccessibleforcheckinginletandoutletgaspressures,flexlineconnections,andwiringtothevalve.See Figure 100. Figure 101 shows the inlet and outlet gas test ports.

Figure 100

Figure 101

9. Replacethegasvalvebyremovingthetwo5/16-inchhex-headscrewsontopofthegascontrolbracket.Thegasvalveandbracketcanbelifteduptogainaccesstotheflexlineconnections.

Page 55: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 55

MAINTENANCE AND SERVICE (CONT’D)MAINTENANCE AND SERVICETheonlyrecommendedmaintenanceforthehomeownerisperiodically cleaning the glass. Before cleaning the glass read the warnings below.Thisfireplacehasnouser-serviceablemechanicalcomponents.Contactyourdealeroraqualifiedgasapplianceservicetechnician for all service and repair.

ACCESSING THE CONTROL MODULE

WARNINGAlways turn off gas and electrical supply to the fireplace before servicing.

1. Remove the barrier screen and glass door assemblies, and set them aside in a safe location.

2. It is not necessary to remove decorative glass media from the burner cover or accent glass panels to gain access to the control module.

3. Thecontrolmoduleisinthelowerfrontcornerofthefireplacebottom.ItissecuredtothefireplacewithVelcro.ThegascontrolandLEDlightwiringisroutedthroughthelower right side opening to the gas valve wire connections. The120Vpowercordsareroutedthroughthelowerrightside opening and plugged into the Junction Box receptacle.

Refer to the electrical connections section for additional information.

MAINTENANCEMaintenance frequency must be determined individually for each application.Someconsiderationsare:• Cyclingfrequency.Fireplacesthatmaycycle20,000times

annually should be checked monthly.• Intermittentuse.Fireplacesthatareusedseasonallyshould

be checked before shutdown and again before the next use.• Dusty,wetorcorrosiveenvironment.Becausethese

environments can cause the gas control to deteriorate more rapidly, the system should be checked more often.

• Anycontrolshouldbereplacedifitdoesnotperformproperlyon checkout or service. In addition, replace any module if it is wet or looks like it has been wet.

SERVICEDonotdisassemblethegascontrol;itcontainsnon-replaceablecomponents. Attempted disassembly or repair can damage the control.Exactlyfollowthewarningsandthelightinginstructions.1. Beforelighting,smellaroundthefireplaceareaforgas.If

thefireplaceusesPropane(bottled)gas,besuretosmellnexttothefloorbecausePropanegasisheavierthanair.Ifyou smell gas, immediately shut off the manual valve in the gaspipingtothefireplaceoronPropaneatthetank.Donottrytolightanyappliance.Donottouchanyelectricalswitchor use the phone. Leave the building and call your gas supplier.Ifyourgassuppliercannotbereached,callthefiredepartment.

2. Thegascontrolmustbereplacedifithasbeenfloodedwithwater.Callaqualifiedservicetechnician.

3. Thegascontrolisasafetydevice.Itmustbereplacedin case of any physical damage such as bent terminals, missing parts, stripped threads, or evidence of exposure to excessive heat.

Follow the operating instructions provided by the manufacturer of

your appliance.

NOTICE: Itisnormalforfireplacesfabricatedofsteeltogiveoffsomeexpansionand/orcontractionnoiseduringthestartuporcooldowncycle.Similarnoisesarefoundwithyourfurnaceheatexchanger or car engine.Itisnormalforyourgasfireplacetogiveoffsomeodorthefirsttimeitisburned.Thisisduetothecuringofthepaintandoilfromthe manufacturing process.

Please ensure that your room is well ventilated - open a window.

Burn your fireplace for at least one hour the first time you use it. If optional fan kit has been installed, place fan in the OFF position during this time.IMPORTANT: Turnoffgasbeforeservicingfireplace.Haveaqualifiedservicepersonperformthesecheck-upsonceayearpreferablybeforetheusingofthefireplace.• Clean Burner and Control Compartment Keepthecontrolcompartmentandburnerareacleanby

vacuuming or brushing at least twice a year.CLEANING PROCEDURE1. Turnofffireplace.2. Removethebarrierscreenandglassdoorassembly.See

GlassDoorRemoval.3. Removedecorativemedia(acleanportableshop-vacis

recommended).4. Vacuumburnercoverandburnerscreenareas.Thecontrol

module located in the bottom front corner can also be vacuumed off.

5. Replace decorative media.6. Reinstall the glass door and barrier screen.7. Ignitefireplace.SeeLightingInstructions.8. Ifflameappearsabnormal,callaserviceperson.

WARNINGHandle the glass with care to avoid breaking it. Never strike the glass. To prevent etching or discoloring, clean the glass with Fireplace Glass Cleaner (available from your dealer). Never use cleaners that contain ammonia or abrasives. Never clean the glass while it is hot or even warm. Touching hot glass can cause severe burns. Using liquids or aerosols on hot glass will cause it to shatter. Never operate the fireplace with the glass removed or cracked. Have your dealer replace damaged glass only with glass and gasket material from Empire Comfort Systems. Using substitute glass will void the warranty.

Page 56: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 56

• CHECK VENT SYSTEM Thefireplaceandventingsystemshouldbeinspectedbeforeinitialuseandatleastannuallybyaqualifiedserviceperson.Inspect the external vent cap on a regular basis to make sure thatnodebrisisinterferingwiththeairflow.

GLASS CLEANINGClean the glass before use and two or three times each heating season.Duringstart-upcondensation(whichisnormal)formsonthe inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may depositaslightfilmontheglass.Useanon-abrasivehouseholdcleanerandwarmwater(werecommendgasfireplaceglasscleaner).

WARNINGDo not use Ammonia based or abrasive cleaners on glass. Do not attempt to clean glass when glass is hot.

GENERAL GLASS INFORMATION

WARNINGDo not operate fireplace with the glass front removed, cracked or broken.

Onlyglassapprovedforusebythemanufacturerinfireplacemaybeusedforreplacement.Theglassreplacementshouldbedonebyalicensedorqualifiedserviceperson.

WARNING1. The use of substitute glass will void all product warranties.2. Care must be taken to avoid breakage of the glass.3. Under no circumstances should this fireplace be operated

without the glass front or with a broken glass front. Replacement of the glass (with gasket) as supplied by the manufacturer should be done by a qualified service person.

4. Do not abuse the glass by striking or hitting it.

MAINTENANCE AND SERVICE (CONT’D)GLASS DOOR AND BARRIER SCREEN REMOVAL AND REPLACEMENTRefer to page 53 for removal of the barrier screen and glass door assemblies.Refer to the Parts View and Parts List on pages 50 and 51 to identify replacement parts such as the barrier screen and glass door assemblies.GLASS DOOR INSTALLATIONRefer to Figures 96 and 97 to install the glass door assembly. Because of the width of the door assembly, it is recommended thattwopeopleinstallit.Holdthedooratananglesothebottomisabout8inchesfromthefireplaceface.Engagethetopslotsintodoorframewiththetabslocatedatthetopofthefirebox.Gentlypivotthedoorinwardtoalignthefourbulletcatchesacross the bottom of the door frame. Once the bullet pins are aligned with the spring catches on the door frame, push the bottom of the door inward to engage the spring catches with the bullet pins.

DOOR LIMITER BRACKET INSTALLATIONAftertheGlassDoorisinstalled,theDoorLimiterBracketmustbeattached.Usinga5/16-inchhexnutdriver,install(5)#10-24x3/8-inchscrewstoretaintheLimiterBrackettothebottomflangeoftheGlassDoorframe.NOTICE: TheDoorLimiterBracketmustbere-installedtotheGlassDoorframepriortooperationofthefireplace.BARRIER INSTALLATIONThebarrierscreenassemblyinstallsontotheglassdoorassemblywithoutfasteners.Thetopflangeofthebarrierengagesthetopofthedoorframeandthebottomflange.Thebottomflangeonthebarrierinsertsbetweentheglassdoorframeacross the bottom. Adjust the barrier left to right to center it.

Page 57: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 57

IMPORTANT SAFETY INFORMATION

WARNINGRead and follow these safety precautions prior to operating this fireplace. Failure to follow these precautions may result in death, injury, or property damage.

Before enclosing the vent pipe assembly, operate the fireplace to ensure it is venting properly.

WARNINGDO NOT operate this fireplace without the glass panel installed.

• Alertchildrenandadultstothehazardsofhighsurfacetemperatures and warn them to stay away to avoid burns or clothing ignition.

• Carefullysuperviseyoungchildrenwhentheyareinthesameroomasthefireplace.

• Donotplaceclothingorotherflammablematerialonornearthefireplace.

• Keeptheareaaroundyourfireplaceclearofcombustiblematerials,gasolineandotherflammablevaporandliquids.

• Neverburnsolidfuels(wood,coal,paperorcardboardetc.)inthisfireplace.

• Donotrestricttheflowofcombustionandventilationairaroundthefireplace.

• Duetohightemperatures,keepfurnitureanddraperiesawayfromthefireplace.

• Replacetheglassfrontoranypartremovedforservicingpriortooperatingthefireplace.

• Ventcapishotwhilefireplaceisinoperationandsometimeafterward.

• Installation and repair should be done by a QUALIFIED SERVICE PERSON. Thefireplaceshouldbeinspectedbeforeuseandatleastannuallybyaqualifiedserviceperson. More frequent cleaning may be required due to excessivelintfromcarpeting,beddingmaterials,etc.Keepthe control compartments, burners and circulating air passageways clean.

CAUTIONIf the glass is cracked or damaged in any way, it should be replaced only with a complete glass frame assembly from Empire. See parts list on pages 50 and 51 for ordering.

• Donot usethisfireplaceifanyparthasbeenunderwater.Immediatelycallaqualifiedservicetechniciantoinspectthefireplaceandtoreplaceanypartofthecontrolsystemandany gas control which has been under water.

• Haveaqualifiedtechnicianexaminetheventingsystemeach year and replace damaged parts.

• Make a periodic visual check of pilot and burners. Clean and replace damaged parts.

• Abarrierdesignedtoreducetheriskofburnsfromthehotviewingglassisprovidedwiththisfireplaceandshallbe installed for the protection of children and other at-risk individuals.

• Ifthebarrierbecomesdamaged,thebarriershallbereplacedwiththemanufacturer’sbarrierforthisfireplace.

Combustible MaterialDonotattachcombustiblematerialtothemantelofyourfireplace.Thisisafirehazard.Nogreetingcard,stockingsorornamentation of any type should be placed on or attached to thefireplace.Thisisaheatingappliance.Theheatcanignitecombustibles.

Figure 102

Page 58: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 58

SAFETY INFORMATION FOR USERS OF PROPANE GASPropane is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. You may not know all the following safety precautions which can protect both you and your family from an accident. Read them carefully now, then review them point by point with the members of your household. Someday when there may not be a minute to lose, everyone’s safety will depend on knowing exactly what to do. If, after reading the following information, you feel you still need more information, please contact your gas supplier.

PROPANE GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the Propane Gas. That’s your signal to go into immediate action!

• Donotoperateelectricswitches,lightmatches,useyourphone.Donotdoanythingthatcouldignitethegas.

• Geteveryoneoutofthebuilding,vehicle,trailer,orarea.DothatIMMEDIATELY.

• Closeallgastankorcylindersupplyvalves.• PropaneGasisheavierthanairandmaysettleinlowareas

such as basements. When you have reason to suspect a gas leak,keepoutofbasementsandotherlowareas.Stayoutuntilfirefightersdeclarethemtobesafe.

• Useyourneighbor’sphoneandcallatrainedPropaneGasservicepersonandthefiredepartment.Eventhoughyoumay not continue to smell gas, do not turn on the gas again. Donotre-enterthebuilding,vehicle,trailer,orarea.

• Finally,lettheservicemanandfirefighterscheckforescapedgas.Havethemairouttheareabeforeyoureturn.ProperlytrainedPropaneGasservicepeopleshouldrepairtheleak,thencheckandrelightthegasfireplaceforyou.

NO ODOR DETECTED - ODOR FADESome people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane.Smokingcandecrease your ability to smell. Being around an odor for a time canaffectyoursensitivityorabilitytodetectthatodor.Sometimesother odors in the area mask the gas odor. People may not smell thegasodorortheirmindsareonsomethingelse.Thinkingabout smelling a gas odor can make it easier to smell.The odorant in Propane Gas is colorless, and it can fade under some circumstances. For example, if there is an underground leak, the movement of the gas through soil can filtertheodorant.OdorantsinPropaneGasalsoaresubjecttooxidation.Thisfadingcanoccurifthereisrustinsidethestoragetank or in iron gas pipes.

Theodorantinescapedgascanadsorborabsorbontoorintowalls,masonryandothermaterialsandfabricsinaroom.Thatwilltake some of the odorant out of the gas, reducing its odor intensity.PropaneGasmaystratifyinaclosedarea,andtheodorintensitycouldvaryatdifferentlevels.Sinceitisheavierthanair,theremay be more odor at lower levels. Always be sensitive to the slightest gas odor. If you detect any odor, treat it as a serious leak. Immediately go into action as instructed earlier.

SOME POINTS TO REMEMBER• Learn to recognize the odor of Propane Gas. Your local

PropaneGasDealercangiveyoua“ScratchandSniff”pamphlet.Useittofindoutwhatthepropaneodorsmellslike.IfyoususpectthatyourPropaneGashasaweakorabnormalodor,callyourPropaneGasDealer.

• Ifyouarenotqualified,donotlightpilotlights,performservice, or make adjustments to appliances on the Propane Gassystem.Ifyouarequalified,consciouslythinkabouttheodorofPropaneGaspriortoandwhilelightingpilotlightsorperforming service or making adjustments.

• Sometimesabasementoraclosed-uphousehasamustysmellthatcancoverupthePropaneGasodor.Donottrytolight pilot lights, perform service, or make adjustments in an area where the conditions are such that you may not detect theodoriftherehasbeenaleakofPropaneGas.

• Odorfade,duetooxidationbyrustoradsorptiononwallsofnewcylindersandtanks,ispossible.Therefore,peopleshould be particularly alert and careful when new tanks or cylinders are placed in service. Odor fade can occur in new tanks,orreinstalledoldtanks,iftheyarefilledandallowedtosettoolongbeforerefilling.Cylindersandtankswhichhave been out of service for a time may develop internal rust which will cause odor fade. If such conditions are suspected to exist, a periodic sniff test of the gas is advisable. If you have any question about the gas odor, call your Propane Gas Dealer. A periodic sniff test of the Propane Gas is a good safety measure under any condition.

• If,atanytime,youdonotsmellthePropaneGasodorantandyouthinkyoushould,assumeyouhavealeak.Thentake the same immediate action recommended above for the occasionwhenyoudodetecttheodorizedPropaneGas.

• Ifyouexperienceacomplete“gasout,”(thecontainerisundernovaporpressure),turnthetankvalveoffimmediately. If the container valve is left on, the container may draw in some air through openings such as pilot light orifices.Ifthisoccurs,somenewinternalrustingcouldoccur.If the valve is left open, then treat the container as a new tank. Always be sure your container is under vapor pressure by turning it off at the container before it goes completely emptyorhavingitrefilledbeforeitiscompletelyempty.

Page 59: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 59

REQUIREMENTS FOR MASSACHUSETTSForallsidewallhorizontallyventedgasfueledequipmentinstalled in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust ventterminationislessthansevenfeetabovefinishedgradeinthe area of the venting, including but not limited to decks and porches,thefollowingrequirementsshallbesatisfied:

1. INSTALLATIONOFCARBONMONOXIDEDETECTORS.Atthetimeofinstallationofthesidewallhorizontalventedgasfueledequipment,theinstallingplumberorgasfittershallobserve that a hard wired carbon monoxide detector with analarmandbatteryback-upisinstalledonthefloorlevelwhere the gas equipment is to be installed. In addition, the installingplumberorgasfittershallobservethatabatteryoperated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, buildingorstructureservedbythesidewallhorizontalvented gas fueled equipment. It shall be the responsibility ofthepropertyownertosecuretheservicesofqualifiedlicensed professionals for the installation of hard wired carbon monoxide detectors

a. Intheeventthatthesidewallhorizontallyventedgasfueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floorlevel.

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty days to comply with the above requirements; provided, however, that during said thirty day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2. APPROVEDCARBONMONOXIDEDETECTORS.Eachcarbon monoxide detector as required in accordance with theaboveprovisionsshallcomplywithNFPA720andbeANSI/UL2034listedandIAScertified.

3. SIGNAGE.Ametalorplasticidentificationplateshallbepermanently mounted to the exterior of the building at a minimum height of eight feet above grade directly in line with theexhaustventterminationforthehorizontallyventedgasfueledapplianceorequipment.Thesignshallread,inprintsizenolessthan1/2inchinsize,“GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

4. INSPECTION.Thestateorlocalgasinspectorofthesidewallhorizontallyventedgasfueledequipmentshallnot approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1through4.

(b) EXEMPTIONS:Thefollowingequipmentisexemptfrom248CMR5.08(2)(a)1through4:

1. TheequipmentlistedinChapter10entitled“EquipmentNotRequiredToBeVented”inthemostcurrenteditionofNFPA54asadoptedbytheBoard; and

2. ProductApprovedsidewallhorizontallyventedgasfueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

(d) MANUFACTURERREQUIREMENTS-GASEQUIPMENTVENTINGSYSTEMNOTPROVIDED.When the manufacturer of a Product Approved side wallhorizontallyventedgasfueledequipmentdoesnotprovidethepartsforventingthefluegases,butidentifies“specialventingsystems”,thefollowingrequirementsshallbesatisfiedbythemanufacturer:

1. Thereferenced“specialventingsystem”instructions shall be included with the appliance or equipment installation instructions; and

2. The“specialventingsystems”shallbeProductApproved by the Board, and the instructions for that system shall include a parts list and detailed installation instruction.

(e) AcopyofallinstallationinstructionsforallProductApprovedsidewallhorizontallyventedgasfueledequipment, all venting instructions, all parts lists forventinginstructions,and/orallventingdesigninstructions shall remain with the appliance or equipment at the completion of the installation.

Page 60: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 60

FIREPLACE SERVICE HISTORYDate Dealer Name Service Technician Name Service Performed/Notes

Page 61: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 61

FIREPLACE SERVICE HISTORYDate Dealer Name Service Technician Name Service Performed/Notes

Page 62: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818Page 62

ToOrderPartsUnderWarranty,pleasecontactyourlocalEmpiredealer.Seethedealerlocatoratwww.empirecomfort.com.Toprovidewarrantyservice,yourdealerwillneedyournameandaddress,purchasedateandserialnumber,andthenatureof the problem with the unit. ToOrderPartsAftertheWarrantyPeriod,pleasecontactyourdealeroroneoftheMasterPartsDistributorslistedbelow.Thislistchangesfromtimetotime.Forthecurrentlist,pleaseclickontheMasterPartsbuttonatwww.empirecomfort.com.Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered OriginalEquipmentrepairpartsforHeaters,Grills,andFireplacesmanufacturedbyEmpireComfortSystemsInc.

MASTER PARTS DISTRIBUTOR LIST

Parts Not Under WarrantyPartscanbeorderedthroughyourServicePerson,Dealer,oraMasterPartsDistributor.SeethispagefortheMasterPartsDistribu-tors list. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer.Warranty PartsWarrantypartswillneedaproofofpurchaseandcanbeorderedbyyourServicePersonorDealer.Proofofpurchaseisrequired for warranty parts.AllpartslistedinthePartsListhaveaPartNumber.Whenorderingparts,firstobtaintheModelNumberandSerialNumberfromthenameplateonyourequipment.ThendeterminethePartNumber(nottheIndexNumber)andtheDescriptionofeachpartfromthefol-lowing illustration and part list. Be sure to give all this information . . .

FireplaceModelNumber PartDescription

FireplaceSerialNumber PartNumber

TypeofGas(PropaneorNatural)

Donotorderbolts,screws,washersornuts.Theyarestandardhardwareitemsandcanbepurchasedatanylocalhardwarestore.Shipmentscontingentuponstrikes,firesandallcausesbeyondourcontrol.

HOW TO ORDER REPAIR PARTS

Dey Distributing1401 Willow Lake BoulevardVadnaisHeights,MN55101

Phone: 651-490-9191Toll Free: 800-397-1339Website: www.deydistributing.comParts: Heater, Hearth and Grills

F. W. Webb Company200LocustStreetHartford,CT06114

Phone: 860-722-2433Toll Free: 800-243-9360Fax: 860-293-0479Toll Free Fax: 800-274-2004Websites: www.fwwebb.com & www.victormfg.comParts: Heater, Hearth and Grills

East Coast Energy Products10EastRoute36WestLongBranch,NJ07764

Phone: 732-870-8809Toll Free: 800-755-8809Fax: 732-870-8811Website: www.eastcoastenergy.comParts: Heater, Hearth and Grills

Page 63: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-5-0818 Page 63

EmpireComfortSystemsInc.warrantiesthishearthproducttobefreefromdefectsatthetimeofpurchaseandfortheperiodsspecifiedbelow.Hearthproductsmustbeinstalledbyaqualifiedtechnicianandmustbemaintainedandoperatedsafely,inaccordancewiththeinstructionsintheowner’smanual.EmpirewillnotwarrantyanyChâteau,Boulevard,orMantisfireplacethatisnotinstalledbythesellingdealerorthatdealer’sdirectcontractagents.Thiswarrantyappliestotheoriginalpurchaseronlyandisnottransferable.Allwarrantyrepairsmustbeaccomplishedbyaqualifiedgasappliancetechnician.

Limited Lifetime Parts Warranty – Combustion Chamber, Heat Exchanger, and Factory-Installed Glass Ifthecombustionchamber,heatexchanger(seepartslist)orfactory-installedglassfailsbecauseofdefective

workmanshipormaterial,EmpirewillrepairorreplaceatEmpire’soption.Limited Three-Year Parts Warranty – All Other Components (Except Remote Controls, Thermostats, Accessories and Replacement Parts)

Shouldanypartfailbecauseofdefectiveworkmanshipormaterialwithinthreeyearsfromthedateofpurchase, EmpirewillrepairorreplaceatEmpire’soption.Limited One-Year Parts Warranty – Remote Controls, Thermostats, Accessories, and Parts

Shouldanyremotecontrol,thermostat,accessory,orotherpartfailbecauseofdefectiveworkmanshipwithinone yearfromthedateofpurchase,EmpirewillrepairorreplaceatEmpire’soption.

Duties of the Owner Theappliancemustbeinstalledbyaqualifiedinstallerandoperatedinaccordancewiththeinstructionsfurnished with the appliance. A bill of sale, cancelled check, or payment record should be kept to verify purchase date and establish warranty period. Ready access to the appliance for service.

What Is Not Covered Damagesthatmightresultfromtheuse,misuse,orimproperinstallationofthisappliance. Travel,diagnosticcostsandfreightchargesonwarrantedpartstoandfromthefactory. Claims that do not involve defective workmanship or materials. Unauthorizedserviceorpartsreplacements. Removal and reinstallation cost. Inoperable due to improper or lack of maintenance.

How To Get Service Tomakeaclaimunderthiswarranty,pleasehaveyourreceiptavailableandcontactyourinstallingdealer. Providethedealerwiththemodelnumber,serialnumber,typeofgas,andpurchaseverification.Theinstalling dealer is responsible for providing service and will contact the factory to initiate any warranted parts replacements. Empirewillmakereplacementpartsavailableatthefactory.Shippingexpensesarenotcovered. If,aftercontactingyourEmpiredealer,servicereceivedhasnotbeensatisfactory,contact:Consumer RelationsDepartment,EmpireComfortSystemsInc.,POBox529,Belleville,Illinois62222,orsendane-mailto [email protected]“ConsumerRelations”inthesubjectline.

Your Rights Under State Law Thiswarrantygivesyouspecificlegalrights,andyoumayalsohaveotherrights,whichvaryfromstatetostate.

WARRANTY

Page 64: WARNING - HVACDirect.com...This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes

38217-0-0717www.empirecomfort.com

Empire Comfort Systems Inc.Belleville, ILIf you have a general question about our products, please e-mail us at [email protected]. If you have a service or repair question, please contact your dealer.