water flow diagram - mirabelleproducts.commirabelleproducts.com/ferguson/mirabelle.com/images/...hot...

11
water flow from outlet 1 & 2 water flow from outlet 2 water flow from outlet 1 1 2 3 1 2 3 1 2 3 water flow from outlet 3 water flow from outlet 1 & 3 water flow from outlet 2 & 3 1 2 3 1 2 3 1 2 3 Note: Valve comes standard with 6-way cartridge. Each setting has a distinct position. Operating water pressure required per number of components. Components based on 2.5GPM each. Outlets Supported Component 2 Components 5 Components 6 Components 45 psi 50 psi 60 psi 70 psi 6-Way Transfer Valve - MIR6101 & MIR6103 page 29 of 40 WATER FLOW DIAGRAM © Ferguson Enterprises, Inc. PL-MIR-850 14503 05/13

Upload: lymien

Post on 10-May-2018

214 views

Category:

Documents


1 download

TRANSCRIPT

water flow from outlet 3

water flow from outlet 1 & 2 water flow from outlet 2

water flow from outlet 1 & 3

water flow from outlet 1

water flow from outlet 2 & 3

Note: Valve comes standard with 6-way cartridge.Each setting has a distinct position.

1

23

1

23

1

2

3

1

23

1

2

3

1

23water flow from outlet 3

water flow from outlet 1 & 2 water flow from outlet 2

water flow from outlet 1 & 3

water flow from outlet 1

water flow from outlet 2 & 3

Note: Valve comes standard with 6-way cartridge.Each setting has a distinct position.

1

23

1

23

1

2

3

1

23

1

2

3

1

23water flow from outlet 3

water flow from outlet 1 & 2 water flow from outlet 2

water flow from outlet 1 & 3

water flow from outlet 1

water flow from outlet 2 & 3

Note: Valve comes standard with 6-way cartridge.Each setting has a distinct position.

1

23

1

23

1

2

3

1

23

1

2

3

1

23

1st Position Outlet 1 2nd Position 3rd Position

4th Position 5th Position 6th Position

1 1 1

111

22 2

222

3 3 3

333

Outlet 1 & 2 Outlet 2

Outlet 2 & 3 Outlet 3 Outlet 3 & 1

Operating water pressure required per number of components.Components based on 2.5GPM each.

OutletsSupported

Component 2 Components 5 Components 6 Components

45 psi ● ●

50 psi ● ● ●

60 psi ● ● ● ●

70 psi ● ● ● ●

6-way Transfer valve - MIR6101 & MIR6103

page 29 of 40

w A T E R f l o w d I A G R A M

© Ferguson Enterprises, Inc. PL-MIR-850 14503 05/13

water flow from outlet 3water flow from outlet 2water flow from outlet 1

Note: The MIR6110 is an OPTIONAL cartridge. Flow is shared between 3 distinct positions.

1

23

1

2

3

1

2

3

water flow from outlet 3water flow from outlet 2water flow from outlet 1

Note: The MIR6150 is an OPTIONAL cartridge. Flow is NOT shared between 3 distinct positions.

1

23

1

2

3

1

2

3

water flow from outlet 3water flow from outlet 2water flow from outlet 1

Note: The MIR6110 is an OPTIONAL cartridge. Flow is shared between 3 distinct positions.

1

23

1

2

3

1

2

3

water flow from outlet 3water flow from outlet 2water flow from outlet 1

Note: The MIR6150 is an OPTIONAL cartridge. Flow is NOT shared between 3 distinct positions.

1

23

1

2

3

1

2

3

3-wAy cARTRIdGE MIR6110

cAlGREEN cARTRIdGE MIR6150

page 30 of 40

w A T E R f l o w d I A G R A M

© Ferguson Enterprises, Inc. PL-MIR-850 14503 05/13

hot water inletcold water inlet

Bodysprays:A pressure-balancing loop must always be used with bodysprays to allow for equal supply of water to each spray.

Arrow on volume control valve should always point in direction of �ow.

Always cap the tub port when using the valve in a vertical spa con�guration.

Thermostatic Valve with Volume Control and Transfer Valve with 3 Outlets

Multiple outlet transfer valve

NOTE: Always add up the total maximum �ow of all outlets and ensure that total potential �ow does not exceed any valves �ow rating. Check with state and local codes for maximum system GPM �ow rates allowed.

page 31 of 40

I N S T A l l A T I o N G U I d E l I N E S

© Ferguson Enterprises, Inc. PL-MIR-850 14503 05/13

Cap the unused tub outlet port.

Arrow on volume control valve should always point in direction of �ow.

Bodysprays:A pressure-balancing loop must always be used with bodysprays to allow for equal supply of water to each spray.

cold water inlethot water inlet

If a port is unused, loop the port into another outlet pipe.

Thermostatic Valve with Volume Control and Transfer Valve with 2 Outlets

NOTE: Always add up the total maximum �ow of all outlets and ensure that total potential �ow does not exceed any valves �ow rating. Check with state and local codes for maximum system GPM �ow rates allowed.

page 32 of 40

I N S T A l l A T I o N G U I d E l I N E S

© Ferguson Enterprises, Inc. PL-MIR-850 14503 05/13

Cap the unused tub outlet port.

Arrow on volume control valve should always point in direction of �ow.

Bodysprays:A pressure-balancing loop must always be used with bodysprays to allow for equal supply of water to each spray.

cold water inlethot water inlet

If a port is unused, loop the port into another outlet pipe.

Thermostatic Valve with Volume Control and Transfer Valve with 2 Outlets

NOTE: Always add up the total maximum �ow of all outlets and ensure that total potential �ow does not exceed any valves �ow rating. Check with state and local codes for maximum system GPM �ow rates allowed.

page 33 of 40

I N S T A l l A T I o N G U I d E l I N E S

© Ferguson Enterprises, Inc. PL-MIR-850 14503 05/13

hot water inletcold water inlet

Arrow on volume control valve should always point in direction of �ow.

Cap the unused tub outlet port.

If a port is unused, loop the port into another outlet pipe.

Thermostatic Valve with Volume Control and Transfer Valve with 2 Outlets

NOTE: Always add up the total maximum �ow of all outlets and ensure that total potential �ow does not exceed any valves �ow rating. Check with state and local codes for maximum system GPM �ow rates allowed.

page 34 of 40

I N S T A l l A T I o N G U I d E l I N E S

© Ferguson Enterprises, Inc. PL-MIR-850 14503 05/13

Cap the unused tub outlet port.

Arrow on volume control valve should always point in direction of �ow.

Bodysprays:A pressure-balancing loop must always be used with bodysprays to allow for equal supply of water to each spray.

cold water inlethot water inlet

Thermostatic Valve with Multiple Volume Controls

NOTE: Always add up the total maximum �ow of all outlets and ensure that total potential �ow does not exceed any valves �ow rating. Check with state and local codes for maximum system GPM �ow rates allowed.

page 35 of 40

I N S T A l l A T I o N G U I d E l I N E S

© Ferguson Enterprises, Inc. PL-MIR-850 14503 05/13

Cap the unused tub outlet port.

Bodysprays:A pressure-balancing loop must always be used with bodysprays to allow for equal supply of water to each spray.

Cold water inlet

Hot water inlet

Thermostatic Valve with Multiple Volume Controls

NOTE: Always add up the total maximum �ow of all outlets and ensure that total potential �ow does not exceed the thermostatic valve �ow rating.Check with state and local codes for maximum system GPM ow rates allowed.

Twin ell

Tub spout diverter

page 36 of 40

I N S T A l l A T I o N G U I d E l I N E S

© Ferguson Enterprises, Inc. PL-MIR-850 14503 05/13

If a port is unused, loop the port into another outlet pipe.

Cap the unused tub outlet port.

cold water inlethot water inlet

Pressure Balanced Valve with Transfer Valve and 2 Outlets

NOTE: Always add up the total maximum �ow of all outlets and ensure that total potential �ow does not exceed the pressure balanced valve �ow rating. Check with state and local codes for maximum system GPM �ow rates allowed.

page 37 of 40

I N S T A l l A T I o N G U I d E l I N E S

© Ferguson Enterprises, Inc. PL-MIR-850 14503 05/13

NOTE: Always add up the total maximum �ow of all outlets and ensure that total potential �ow does not exceed the pressure balanced valve �ow rating. Check with state and local codes for maximum system GPM �ow rates allowed.

Pressure Balanced Valve with Transfer Valve, 2 Outlets and Tub Spout

hot water inlet

cold water inlet

If a port is unused, loop the port into another outlet pipe.

page 38 of 40

I N S T A l l A T I o N G U I d E l I N E S

© Ferguson Enterprises, Inc. PL-MIR-850 14503 05/13

wHAT IS covEREd?Mirabelle warrants to the ORIGINAL CONSUMER PURCHASER that its faucets (except as explained under paragraph 3, below) shall be free from defects in material and workmanship under normal use and service FOR SO LONG AS THE FAUCET IS USED IN ITS ORIGINAL RESIDENTIAL INSTALLATION. If the faucet is used in industrial, commercial or business applications, the preceding sentence does not apply, but rather FOR ALL INDUSTRIAL, COMMERCIAL OR BUSINESS APPLICATIONS, THE WARRANTY SHALL BE A FIVE (5) YEAR LIMITED WARRANTY FROM THE DATE OF PURCHASE WITH ALL OTHER TERMS AND EXCLUSIONS OF THE WARRANTY APPLICABLE. This consumer warranty and this industrial/commercial/business warranty is applicable only to faucets purchased on or after June 1, 2003, starting on the date on the proof of purchase. For faucets purchased before June 1, 2003, the Mirabelle one-year limited warranty will apply.

coMpANy’S oblIGATIoNSThe Company’s obligations under the warranty set forth in paragraph 1 above shall be to replace free of charge any MIRABELLE faucet or component which is defective as stated above, or at the option of Mirabelle, to either refund the purchase price or repair the faucet. THE WARRANTY SET FORTH IN PARAGRAPH 1 IS IN LIEU OF ANY OTHER WARRANTY, EXPRESS OR IMPLIED, AND SHALL RUN TO THE ORIGINAL PURCHASER ONLY.

wHAT IS NoT covEREd?The warranty set forth in paragraph 1 does not cover and Mirabelle is not liable for, installation or any other labor charges or products which have been damaged as a result of any accident, misuse, abuse, neglect, improper installation or main-tenance, the use of abrasive or organic solvent cleaners, modification, failure to use the faucet in accordance with instruc-tions provided by Mirabelle or use of parts other than Mirabelle parts.

How To obTAIN wARRANTy SERvIcEUS Customers:The purchaser should contact their local Ferguson location, installing contractor or builder from whom the product was purchased. To find your nearest Ferguson location please visit www.ferguson.com and enter in your address into the Find a Location field.

Canadian Customers:The purchaser should contact their local Wolseley Canada location, installing contractor or builder from whom the product was purchased. To find your nearest Wolseley Canada location please visit www.wolseleyinc.ca, then click on Find a Location and enter in your address into the location field.

dISclAIMER of coNSEQUENTIAl oR INcIdENTAl dAMAGES ANd oTHER wARRANTIESMIRABELLE SHALL NOT BE LIABLE FOR PERSONAL INJURY OR PROPERTY DAMAGE OR ANY CONSEQUENTIAL, PUNITIVE OR INCIDENTAL DAMAGES. EXCEPT AS STATED IN PARAGRAPH 1, MIRABELLE DISCLAIMS ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. MIRABELLE LIABILITY, IF ANY, SHALL NOT EXCEED THE REPLACEMENT VALUE OF THE DEFECTIVE FAUCET. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state.

Mirabelle is a registered trademark of Ferguson Enterprises, Inc.

Distributed Exclusively by Ferguson and Wolseley Canada

consumer limited lifetime warrantyIndustrial / commercial limited 5-year warranty

page 39 of 40

f A U c E T w A R R A N T y

© Ferguson Enterprises, Inc. PL-MIR-850 14503 05/13