water quality monitoring buoy abu dhabi ports co. abu ... · adpc/kpiz port to monitor water...
TRANSCRIPT
Sutron Corporation | 22400 Davis Drive | Sterling, VA 20164 | 703.406.2800 | www.sutron.com | [email protected] 14, 2015
Overview
The Abu Dhabi Ports Company (ADPC) has established a Water Quality Monitoring Network (WQMN) comprised of (4) Buoys at the Khalifa Port Industrial Zone (KPIZ).
In the scope of the WQMN, Sutron Corporation has delivered (4) WQMN Stations each comprised of the following modules:
GPRSLINK with built-in GPRS modem for data collection, storage and transmission
External GPRS Antenna and cabling
30 W Solar panel
24 AH Battery
Water Quality Manta2, Multiprobe 3.0 in. (supplied by client)
Buoy (supplied locally)
Real-Time SutronWIN Web Hosting, map displays, charts, graphs, reports, data processing and alarms.
Sutron configured each Buoy Water Quality Monitoring Station to measure the following parameters every 10 minutes and transmit data every hour to the SutronWIN server. All measured values are also stored in the internal flash memory of the data logger and stored in SutronWIN server.
Each transmission is encrypted with 6 values for each of the following parameters:
Battery Voltage: BATT in Volts
Potential [H+] in millivolts: PHMV mVolts
Potential [H+] unit: PHU in units
Salinity: SAL in PSS (Practical Salinity Scale)
Specific Conductivity: SPCONDM in mS/cm
Specific Conductivity: SPCONDU in uS/cm
Total Dissolved Solids: TDS in mg/L
Temperature: TEMP in Degree Celsius
Water Quality Monitoring BuoyAbu Dhabi Ports Co. Abu Dhabi, UAE
CLIENT Abu Dhabi Ports Company
PROJECT LOCATION
Abu Dhabi
PROJECT PURPOSE
Monitor Water Quality and transfer real-time data to SutronWin
AWARD & COMPLETION DATE
Award 2/12/2014
Complete 3/1/015
EQUIPMENT & SERVICES
GPRSLink
Eureka Water Quality Sensor
Installation
Training
TELEMETRY & DATA ACQUISITION SOFTWARE
GPRS
SutronWIN Web Hosting & Data Management Service
MEASURED PARAMETERS
Battery Voltage: BATT in Volts
Potential [H+] in millivolts: PHMV mVolts
Potential [H+] unit: PHU in units
Salinity: SAL in PSS (Practical Salinity Scale)
Specific Conductivity: SPCONDM in mS/cm
Specific Conductivity: SPCONDU in uS/cm
Total Dissolved Solids: TDS in mg/L
Temperature: TEMP in Degree Celsius
Sutron Corporation | 22400 Davis Drive | Sterling, VA 20164 | 703.406.2800 | www.sutron.com | [email protected] 14, 2015
Sutron Corporation United Arab Emirates Water Quality Monitoring Buoys 2
Results & Benefits
The Water Quality Monitoring Network allows the ADPC/KPIZ Port to monitor water quality in the industrial zone specifically at the Causeway, RG-Corals, EMAL_Intake and SWC_Outfall.
Via the remote WQMN and SutronWIN Web Hostings the ADPC mission is to implement an action plan when one or all stations in the WQMN network go above the critical set threshold thus enabling the KPIZ Ports to be environmentally friendly by protecting and improving water quality.
SutronWIN web hosting receives real-time data every hour. SutronWIN also allow the user to easily locate each station on the map, allowing charts, graphs, reports, data processing and alarms.