regional oximetry We Chose Nonin Medical’s SenSmart Technology (rSO 2 /SpO 2 ) “We needed a new cerebral/somatic tissue oximetry system that could provide us consistent clinical information, ease- of-use and an extra source of SpO 2 .”

Upload: others

Post on 23-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: We Chose Nonin Medical’s SenSmart ™ Technology (rSO /SpO · regional oximetry We Chose Nonin Medical’s SenSmart ™ Technology (rSO2 /SpO2) “We needed a new cerebral/somatic

regional oximetry

We Chose Nonin Medical’s SenSmart ™ Technology (rSO2 /SpO2)

“We needed a new cerebral/somatic tissue oximetry system that could provide us consistent clinical information, ease-of-use and an extra source of SpO2 .”

Page 2: We Chose Nonin Medical’s SenSmart ™ Technology (rSO /SpO · regional oximetry We Chose Nonin Medical’s SenSmart ™ Technology (rSO2 /SpO2) “We needed a new cerebral/somatic

SenSmart™ rSO2 Technology: 16 Light Paths Greater Accuracy and Reliability through Better ScienceNonin’s SenSmart™ Model X-100 Universal Oximetry System is the only state-of-the-art technology featuring 16 light paths of tissue interrogation (four short and four long wave-lengths in each of two light emitters). Its dual emitter technology enables an advanced, patent-protected algorithm, allowing more distinct signals going out and more detailed data coming in. Other systems only offer between 4 and 10 light paths.

0

2

4

6

8

10

12

14

16

18

Nonin SenSmart™

Casmed FORE-SIGHT™ Elite

Masimo O3™

Medtronic INVOS™

The Most Light Paths for Tissue Interrogation (16)

LIGHT EMITTER

LIGHT EMITTER

LIGHT DETECTOR

4 LIGHT PATHS

4 LIGHT PATHS

4 LIGHT PATHS

4 LIGHT PATHS

Page 3: We Chose Nonin Medical’s SenSmart ™ Technology (rSO /SpO · regional oximetry We Chose Nonin Medical’s SenSmart ™ Technology (rSO2 /SpO2) “We needed a new cerebral/somatic

Absolute rSO2 Accuracy vs Trending rSO2 Accuracy

More and more tissue oximetry monitoring is occurring in situations with very sick patients where establishing a meaningful

baseline can be impossible. The SenSmart System gives you an accurate rSO2 reading without dependence on a baseline.

SpO2 Capability

Nonin Medical has incorporated its well-known PureSAT® SpO2 low-perfusion/motion-tolerant technology into its rSO2 system.

This unique capability allows for monitoring and data download of SpO2 in synchrony with rSO2, which is useful clinically and for research.

6-Channels, All Color-Coded

Nonin’s SenSmart System is the only rSO2 system with up to 6 channels. In addition, the system can use any combination

of multiple SpO2 and rSO2 channels.

60mm of Tissue Coverage (Adult/Pediatric Sensors)

Dual emitters provide 60mm of tissue monitoring width across the skin. Other sensors of the same size offer just 40mm or

50mm of tissue monitoring width.

Over-the-Top Sensor Cable Exit Angle

The only rSO2 cerebral monitoring design with the cables exiting the sensor over the head toward the anesthesia station, avoiding neck

lines and other tangles to the sides.

Portability

Nonin’s SenSmart System is the only system designed to be portable or mounted in place. It weighs just 900 grams and has a 3-hour battery life, compared to other systems weighing over

6 kilos with much less battery life.

Unprecedented Ease of Use

Turn on and start monitoring in less than 30 seconds, unlike other systems requiring up to 2 minutes or more of start-up

and menu selection time.

Neonate/Infant-Specific Sensor Design

Neonate/infant-specific optical spacing targets tissue at neonate/infant depths. A specific algorithm for the neonate/infant sensors

using Nonin’s proprietary Dynamic Compensation™ accounts for widely varying levels of cerebral myelin (an absorbing chromophore) in the first months of life. Adhesive and non-adhesive sensors and no lower weight limit on patient size provide flexibility for use on your smallest patients.

With published accuracy1,2 far exceeding the common, 20+ year-old two-wavelength system on the market, Nonin’s SenSmart System

also offers the following unique benefits:

Page 4: We Chose Nonin Medical’s SenSmart ™ Technology (rSO /SpO · regional oximetry We Chose Nonin Medical’s SenSmart ™ Technology (rSO2 /SpO2) “We needed a new cerebral/somatic

References:

1. MacLeod D, Ikeda, K, Vacchiano C, Lobbestael A, Wahr J, Shaw A. Development and Validation of a Cerebral Oximeter Capable of Absolute Accuracy. Journal of Cardiothoracic and Vascular Anesthesia, December 2012; 26(6):1007-1014.

2. Kreeger R, Ramamoorthy C, Nicolson S, et al. Evaluation of a Pediatric Near-Infrared Cerebral Oximeter for Cardiac Disease. The Annals of Thoracic Surgery. 2012; 94:1527-33.

Are you considering a new rSO2 System? If so, evaluate Nonin Medical’s SenSmart System at no cost or obligation.

For more information or to contact us, visit sensmart.com.

Nonin Medical: Leaders in Noninvasive Medical Monitoring

Nonin Medical is a technology-driven company and a leader in developing high performing, low cost, easy-to-use noninvasive medical monitoring solutions. Nonin took NIRS-based oximetry to a new level of clinical utility when it invented the fingertip pulse oximeter, so the move to provide clinicians with an accurate, versatile, portable regional oximeter was a natural one. Today, Nonin’s new SenSmart™ Universal Oximetry (rSO2/SpO2) System takes clinical utility and convenience to the nth degree, utilizing the same innovative sensing and signal processing technologies that already give millions of clinicians the confidence that the numbers they see reflect their patients’ true physiology.

Nonin Medical NIRS-based oximetry advancements include:

1990 — Introduced world’s first portable hand-held pulse oximeter

1995 — Introduced world’s first fingertip pulse oximeter — the Onyx® 9500

2004 — Introduced world’s first pulse oximeter with Bluetooth® wireless technology

2009 — Introduced EQUANOX™ regional oximetry system

2011 — Introduced industry-leading accuracy in the EQUANOX Advance™ adult absolute regional oximetry sensor for cerebral and somatic applications (8004CA)

2011 — Released world’s first regional oximetry OEM Solution

2012 — Introduced Nonin’s Dynamic Compensation™ algorithm which automatically accounts for pediatric brain tissue development variation when measuring oxygen saturation levels

2013 — Introduced world’s first rSO2 /SpO2 universal oximetry system

All trademarks are the property of Nonin Medical, Inc. unless otherwise noted. Terumo® is a registered trademark of Terumo Corporation. ©2016 Nonin Medical, Inc. October 2016. 875377

MANUFACTURED BY:

Nonin Medical, Inc. 13700 1st Avenue North Plymouth, MN • 55441-5443 • U.S.A. Tel: +1.763.553.9968 1.800.356.8874 Fax: +1.763.577.5521 E-mail: [email protected] nonin.com

Nonin Medical B.V.Prins Hendriklaan 26 1075 BD Amsterdam • Netherlands Tel: +31 (0)13 - 79 99 040 Fax: +31 (0)13 - 79 99 042 E-mail: [email protected]

DISTRIBUTED BY:

Terumo Cardiovascular Group6200 Jackson RoadAnn Arbor, MI 48103-9300Tel: +1.734.663.4145 1.800.521.2818Fax: +1.734.663.7981www.terumo-cvgroup.com