week 4 2_basic_of_electro_hydraulics_design
DESCRIPTION
hydraulic subtopicTRANSCRIPT
![Page 1: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/1.jpg)
![Page 2: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/2.jpg)
By the end of this lecture, student should be able to: ◦ Explain electro-hydraulic components symbol and
function: series and parallel circuits, open/close contact switch, OR/AND logic circuit, relay, coil and solenoid
◦ Design and analyze memory circuit
![Page 3: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/3.jpg)
1. Open Contact Switch
2. Closed Contact Switch
3. Changeover Contact Switch – a combination of an Open and a Closed Contact Switch. Usually used on Relay and Limit Switch.
![Page 4: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/4.jpg)
YES (Identity) Gate
+24V
0V
![Page 5: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/5.jpg)
NOT (Negation) Gate +24V
0V
![Page 6: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/6.jpg)
OR (Conjunction) Gate +24V
0V
![Page 7: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/7.jpg)
AND (Disjunction) Gate +24V
0V
![Page 8: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/8.jpg)
+24V
0V
![Page 9: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/9.jpg)
Coil
Solenoid
![Page 10: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/10.jpg)
IMPORTANT COMPONENTS IN ELECTRO-HYDRAULIC SYSTEMS
RELAY
SOLENOID
![Page 11: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/11.jpg)
Consists of a coil and a set of changeover contact switch
Its function includes:
1. To help switch over small current to larger current
2. To help switch over small voltage to larger voltage
3. Consists of multiple large contact switches for simultaneous switching of multiple outputs
4. Safety feature: Interlock capability
![Page 12: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/12.jpg)
Coil
Coil connections
Contacts
Contact connections
Return spring
Cover
Symbol
A1
A2 11
12 14
21
22 24
Armature
![Page 13: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/13.jpg)
Symbol
A1
A2 11
12 14
21
22 24
A1 A2 4 2 1
![Page 14: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/14.jpg)
Symbol
A1
A2 11
12 14
21
22 24
A1 A2 4 2 1
![Page 15: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/15.jpg)
Symbol
A1
A2 11
12 14
21
22 24
A1 A2 4 2 1
![Page 16: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/16.jpg)
Symbol
A1
A2 11
12 14
21
22 24
A1 A2 4 2 1
![Page 17: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/17.jpg)
The circuit on the right is a direct connection without using relay. The lamp will switch on as soon as the contact switch is closed.
However, if there is a power surge from the main, then the user will experience some form of electric shock.
+24V
0V
![Page 18: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/18.jpg)
The circuit on the right is an indirect connection with a relay (K1). Once the switch is pressed, relay coil (K1) will be energized. The coil will then closes the relay switch thus, switching the lamp.
The safety measure here is that, if there is a power surge from the 240V, then the user will be protected from any form of electric shock.
+24V
0V
K1
K1
2 4 0 V
2 different circuits
![Page 19: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/19.jpg)
A solenoid is like a coil of the relay
When it is energized, it will switch on the valve, similar to turning on the hand lever of a normal valve.
If it is a single solenoid valve, then the valve will switch off automatically through a spring mounted at the opposite end of the valve.
If it is a double solenoid valve, then the valve will switch off only after the second solenoid is being energized.
![Page 20: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/20.jpg)
Single Solenoid Valve Double Solenoid Valve
![Page 21: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/21.jpg)
Hydraulic Circuit Symbol Electrical Circuit Symbol
A B
P T
Y1 Y2
A B
P T
Y1Y1
Y1 Y2
![Page 22: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/22.jpg)
F=0
A B
P T
Y1 Y2
+24V
0V
S1
K1
K1
Y1
S2
K2
K2
Y2
![Page 23: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/23.jpg)
Relevancy:
1. Used to build Continuous Cycle circuit.
2. Used to latch a circuit for continuous supply of electricity to a particular line.
3. Used when replacing a double solenoid valve to a single solenoid valve of a circuit, without changing the originality of the circuit function.
![Page 24: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/24.jpg)
Memory ON (Dominant Set)
+24V
0V
ON
K1
K1
OFF
K1
• When ON is pressed, Relay coil K1 will be energized. Both relay K1 switches will close. This means, while the lamp turns on, the relay switch will continuously energize the coil. Therefore, the lamp is permanently on. Only when the OFF button is pressed, the lamp will switch off.
• To confirm that this is a Memory ON circuit, press both ON and OFF together. The lamp will still light ON.
![Page 25: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/25.jpg)
Memory OFF (Dominant Reset)
• The function of this circuit is similar to the previous Memory ON circuit. However, please note that the OFF button is placed below the ON button, not parallel!
• To confirm that this is a Memory OFF circuit, press both ON and OFF together. The lamp will NOT light ON.
+24V
0V
ON
K1
K1
OFF
K1
![Page 26: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/26.jpg)
Proximity -> closeness
Detect close objects without contact.
Various types:
1. Inductive sensor
2. Capacitive sensor
3. Optical sensor
![Page 27: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/27.jpg)
Used to sense only metal type of object.
![Page 28: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/28.jpg)
Used to sense only high density objects.
![Page 29: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/29.jpg)
Used to sense only reflective type of object.
![Page 30: Week 4 2_basic_of_electro_hydraulics_design](https://reader033.vdocuments.net/reader033/viewer/2022051412/54bdab074a7959f52d8b46e5/html5/thumbnails/30.jpg)