week 5 1_advance_electro_hydraulics_design1
TRANSCRIPT
![Page 1: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/1.jpg)
![Page 2: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/2.jpg)
More than 1 actuator
1 cylinder needs 1 valve
Tips for circuit design:
◦ Identify sequence of movement
◦ Identify limit switch/sensor status
![Page 3: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/3.jpg)
Example: A hydraulic actuated drilling machine
contains two double acting cylinders (DACs). When the work piece is located at its position, cylinder A will clamp the work piece. Then, the drilling process starts, where the spindle is controlled by cylinder B. After completion of drilling, cylinder B will retract to the initial position, before the clamping cylinder retracts.
Sequence: A (extend) -> B (extend) -> B (retract) -> A (retract)
![Page 4: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/4.jpg)
Identify sequence of movement
A+ B+ B- A-
F=0 F=0
Cylinder A Cylinder BA 0 A 1 B 0 B 1
![Page 5: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/5.jpg)
Make the group
A group must contain different elements
1 group represents 1 coil
A+ B+ B- A-
K1 K2
![Page 6: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/6.jpg)
Identify limit switch/sensor status
A+ B+ B- A-
A1 B1 B0 A0
F=0 F=0
Cylinder A Cylinder BA 0 A 1 B 0 B 1
<= Actions
<= Sensors
![Page 7: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/7.jpg)
Rephrasing the sequence and limit switch/sensor status
A1 B0
A+ B+ B- A-
Start B1 A0
Right side of circuit
Left side of circuit
![Page 8: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/8.jpg)
Y1 Y4 Y3 Y2
A0 B1 B0 A1
![Page 9: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/9.jpg)
2 coil for 2 groups
4 solenoid for Y1, Y2, Y3 & Y4
![Page 10: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/10.jpg)
![Page 11: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/11.jpg)
B+ K1 + A1
![Page 12: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/12.jpg)
B- K2 + B1 K2 due to changing group
![Page 13: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/13.jpg)
A- K2 + B0
![Page 14: Week 5 1_advance_electro_hydraulics_design1](https://reader033.vdocuments.net/reader033/viewer/2022060205/55a1efe51a28ab8b1d8b47f2/html5/thumbnails/14.jpg)