what are the global issues that’s driving air conditioning industry today?
DESCRIPTION
What are the Global Issues that’s driving Air Conditioning Industry today?. HIGH OIL PRICE DRIVES HIGH ENERGY PRICE !!. Global Warming ( Kyoto Protocol). in order to reduce CO2 emissions from burning fossil fuels, air- source and water-source heat pumps air conditioner - PowerPoint PPT PresentationTRANSCRIPT
What are the Global Issues that’s driving Air Conditioning Industry today?
HIGH OIL PRICE DRIVES HIGH ENERGY PRICE !!
in order to reduce CO2 emissions from burning fossil fuels,
air- source and water-source heat pumps air conditioner
have been recognized as renewable energy
within the European Economic Recovery Plan and the RES Directive passed in October 2008
Global Warming ( Kyoto Protocol)
Montreal Protocol
High Price of Energy
Global Warming
Effect (Kyoto Protocol)
Global Air Conditioning Market Trend
Thailand• MEPS
• EER Rating
Global Air Conditioning Market TrendUnited State
• >SEER 13
Europe (EC) Region• EER Rating &
Labeling• Restriction of
using HCFC
China• EER Rating &
Labeling
Hong Kong• Restriction of
using HCFC• EER Rating &
Labeling
Singapore• EER Rating &
Labeling• MELS
Austraia• MEPSMalaysia
• Energy Labeling• Tax exemption for
high efficient product
Global Trend:• Energy Labeling• MEPS (Minimum Energy Performance)
Global Trend:• Energy Labeling• MEPS (Minimum Energy Performance)
Saudi Arabia• SASO(MEPS)
Korea• MEPS
R410a Rooftop- High EER
- New refrigerant
Acson is offering you now:
* To understand more features & handset application, please refer to our technical service centre.* To understand more features & handset application, please refer to our technical service centre.
1. Product Line Up
R410a Rooftop Series
Nomenclature & Mass Production Schedule
2. Features
i. Higher EER & COP
LOWEST EER=3.30W/W, HIGHEST =3.43W/W!
LOWEST COP=3.21W/W, HIGHEST =3.47!W/W
2. Features
ii. Higher EER & COP vs Lennox Baltic II
Higher EER up to 7%!
Higher COP up to 15%
2. Features
iii. Highest EER among competitor
NEW 3.31
2. Features
iv. Better Sound level vs Lennox Baltic II
* OD SPW is able to -3dBA during partial loading condition. (only applicable for system with 2 compressors)
NEW Japanese Designed OD Fan promise improve OD SPW!!
2. Features
v. Extended Operating Range
1. NO External FSL/LAK is needed
2. Improve H/E Design for better defrost at extreme ambient.
2. Features
vi. Upgraded Controller
New PCB!
W1W2
Y1Y2
FAN+24VA
C-24VAC
ON/OFF
COOL/HEAT
4-20mA Temperature Adjuster
Thermostat connection point
Basic BMS dry contact
Output Signal
ONOFF
COOLHEAT
DEFROSTALARM
Factory Supply, Standard: with Rooftop panel
Field Supply, Optional:
1. with 3rd party thermostat
2. with Basic BMS Control
Rooftop Panel
Economizer Board
1. Flexibility on Control Option
2. Wide range of standard handset Menu
3. Extension of Economizer PCB
2. Features
vii. LCD Handset with Menu Setting
This new handset comprises all starting, operating
and safety controls setting. It is connected to the IC
module PCB and supplied as standard.
Among the shorlisted features of this handset are as
following:
- 7 days programmable timer with 3 set of ON/OFF
timer/day
- Dirty Filter indication
- Alarm & Warning diagnostic
- Password protection for advance setting
* To understand more features & handset application, please refer to our technical service centre.
2. Features
viii. Field Convertible Air Throw
Std = Horizontal Throw
Site Convertible = Down Throw
Standard factory fitted is always horizontal supply/return. However, unit can be
easily converted from horizontal to vertical (downward) air supply & return
configuration by relocating the panels and supply air fan mounting.
3. Components Features
CompressorCompressor used in A5RT-BR series Packaged Units are hermetically sealed scroll type. All the compressors are provided with an internal overload protection.
CondenserCondenser coils are manufactured from seamless inner grooved copper tubes mechanically bonded to aluminium fins to ensure optimum heat transfer. All coils are tested against by Nitrogen holding at 609psig and highly precise Helium leak test at 235psig. ALL standard coils are up to 3 rows / 14-16 FPI, 3/8” (9.52mm) O.D. tubes.Hydrophilic Gold Fin coating (NA549) is offered as standard, which has longer life span under corrosive environment.
Evaporator : Evaporator coils are manufactured from seamless inner grooved copper tubes mechanically bonded to aluminium fins to ensure optimum heat transfer. All coils are tested against by Nitrogen holding at 609psig and highly precise Helium leak test at 235psig. ALL standard coils are 3-4 rows / 14-16 FPI, 3/8” (9.52mm) O.D. tubes.Hydrophilic Gold Fin coating (NA549) is offered as standard, which has longer life span under corrosive environment..
Casing/ StructureThe unit casing used in A5RT-BR series is made of zinc coated galvanized steel sheets. It is further coated with an electrostatic powder coat and then oven-baked for a tough and lasting weather resistant finish. Zinc plated screws are used throughout to further reduce possibility of unit rusting.
Expansion device: Electronic Expansion Valve is being used to ensure accurate control of refrigerant flow.Refrigerant Circuit
Each refrigerant circuit shall have independent electronic expansion devices, HP/LP switch and refrigerant line service pressure ports as standard factory installed.
Evaporator Fan and DriveBlower is DWDI centrifugal, forward curved type. It is mechanically and dynamically balanced and being mounted on a rigid shaft in a self aligned bearing block. The motor is fitted with an adjustable V-belt drive, as standard. It has class B insulation and dripping water proof, IP22.
Condenser Fan and MotorFans are of propeller type, direct driven by weatherproof electrical induction motors. Condenser fan motor has class F insulation and splash-proof enclosure, IP44.
Insulation: ALL possible areas of condensation to happen are insulated by PE, Polyethelene. Panel insulation is 10mm thickness while drain pan insulation is 5mm thickness.
4. Optional Features
i. EconomizerEconomizer option is available as factory fitted. It is also designed to cater for horizontal or vertical down throw air supply/ return.
ii. CO2 SensorField specified CO2 sensor can be easily plug on the control board’s dry contact, which is available on the Economizer Extension Board.
iii. Auxiliary HeaterAuxiliary heater connection point is available on the standard PCB for field supplied heater connection.
5. Systems Protection
i. Compressor Overloadii. ID/OD Fan Overloadiii. ID Antifreezeiv. OD Defrostv. Power Phase Protection
√√
√√
√
6. Specification
ALL Performance ratings are strictly following and complying to Eurovent Standard.
7. Available Promotional Items
i. Technical Manualii. Sales Leafletiii. Demo Kit
For further inquiry on promotional item, please refer to our technical support centre.