what is new in designbase 5.0 sp2

Upload: babar-saleem

Post on 02-Jun-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    1/60

    W e l c o m e t o P a l a d i n D e s i g n B a s e

    1

    Po w e r A n a l y t i c s C o r p o ra t i o n

    What is New in Paladin DesignBase5.0

    Service Pack 2

    Power Analytics Corporation

    10805 Rancho Bernardo Road, Suite 270

    San Diego, California 92127

    U.S.A.

    U.S. Toll Free Phone: 800-362-0603

    Fax: 858-675-9724

    www.PowerAnalytics.com

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    2/60

    What is New in Paladin DesignBase 5.0 SP2

    2

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    Copyright 2014 Power Analytics Corporation. All rights reserved. Paladin, Power Analytics, Paladin DesignBase,

    Paladin Live, Paladin SmartGrid, Paladin SmartGrid Power Management System, Paladin Gateway, Paladin

    DesignView Paladin WSM, Pa ladin Solar, Intelligence in Rea l Time, and Foresight as Accurate as Hindsight and

    their assoc iated logos and stylings, are pending or registered trademarks of Power Analytics Corporation. All

    other trademarks, names, and logos are the property of their respec tive holders. Power Analytics gratefully

    ac knowledges governmental and regulatory agencies whose names, photos, logos, award programs, or

    certification programs are listed herein; such use does not c onstitute their endorsement of Power Analytics or its

    products by these agenc ies.

    Information in the document is subject to change without notice. The technology described in this document is

    furnished under a license or nondisclosure agreement, and may be used or copied in accordance with the

    terms of those agreements. No part of this publication may be reproduced, stored in a retrieval system, or

    transmitted in any form or any means elec tronic or mechanica l, including photocopying and recording for any

    purpose other than the purchasers use without the written permission of Power Analytics Corporation.

    Power Analytics Corporation

    World Headquarters

    10805 Rancho Bernardo Road, Suite 270San Diego, CA 92127

    Phone: 858-675-9211

    Fax: 858-675-9724

    Power Analytics Corporation

    Eastern United States

    9208 Falls of the Neuse Road, Suite 215

    Raleigh, NC 27615

    919-848-6625

    Fax: 919-848-5256

    U.S. Toll-Free Phone 800-362-0603www.PowerAnalytics.com

    IMPORTANT: Power Analytics Corporations software products are tools intended to be used by trained

    professionals only. They are not substitutes for your professional judgment or for independent verification and

    testing of results as they pertain to your specific application. Use of all Power Analytics Corporation software

    products is governed by the terms and conditions of the End-User License Agreement (EULA) you accepted

    when purchasing and installing the software. You must comply with these terms and conditions in applying the

    instructional material in this manual. If you do not have or are unfamiliar with the contents of your EULA for this

    software, you shouldrequest, read, and understand a copy of yourEULA before proceeding.

    Please accept and respec t the fact that Power Analytics Corporation has enabled you to make an authorized

    disk as a backup to prevent losing the contents that might occur to your original disk drive. DO NOT sell, lend,

    lease, give, rent or otherwise distribute Power Analytics Corporation programs or User's Guides to anyone without

    prior written permission from Power AnalyticsC orporation.

    http://www.poweranalytics.com/http://www.poweranalytics.com/
  • 8/10/2019 What is New in DesignBase 5.0 SP2

    3/60

    What is New in Paladin DesignBase 5.0 SP2

    3

    Re str i c ted to Powe r A na lyt i c s Partners | Do No t D ist ribute

    Dear Valued Customer:

    Thank you for selecting Paladin DesignBase, the best design and modeling software

    available today, and the only power system design software that allows your models to be

    utilized in our Paladin Live solution.

    You are joining a community of power system design professionals that support some of the

    worlds most demanding mission-critica l fac ilities. Our Paladin family software is used to

    Design, Model, Simulate, Analyze and Optimize power grids in a wide array of tec hnical

    fields such as data c enters, critica l power applications such as off-shore oil platforms,

    Federal government applications and the US Navy. We help ensure improved availability

    and reliability, increased efficiency and improved throughput for companies such as

    Boeing, Northrup Grumman, VISA International, Shell, Texas Instruments, Rolls Royce, Elf,

    Alcoa and many other companies around the world who rely on Paladin DesignBase to

    support their most important power systems designs.

    Rec ent releases of Paladin DesignBase incrementally addressed customer requirements in

    three primary areas:

    1. Maximizing power systems designers personal productivity and ease-of-use.

    2. Increasing capabilities for team-based design and the overall project.

    3. Simplifying data management functionality between both DesignBase and third-party

    programs, specifically in terms of allowing models to precisely encapsulate the robust data

    required for on-line facility management using Paladin Live.

    With Paladin DesignBase 5.0 Service Pack 2 we have continued this overall development

    direc tion, while introducing new industry-leading capabilities in exciting areas, including:

    A. Short Circuit Program

    3 Phase Short Circuit fault buses selection option, either from drawings or from

    memory

    Added output CSV file for IEC 61363 detail report

    Added new DC Source for DC Classical SC calculations

    Added new DC Source for the calculations and built the estimating method

    based on IEC61660.

    B. Protection Device Coordination

    New Solid State Breaker curve preview

    Updated Relay program user interface

    Improvements in usability of Digitizer

    User adjustable Bus Curve in PDC TCC

    Created Multiple Labels in PDC curves

    Enhancement of the PDC Show/Restore View icon

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    4/60

    What is New in Paladin DesignBase 5.0 SP2

    4

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    Created on/off icon for Opening/Closing the PDC tool-box

    On/Off option for Designed Load Amp part of Bus Curve in PDC TCC

    New PDC interpolate Function

    Transformer Damage Curve Updates according to IEEE C57.12.59 2001

    Shows coordinates when moving each PDC curve's arrow in PDC program Added Delete and Append option for elements in PDC study

    Added a searching feature for a specific element in multiple PDC studies

    Added new G&W relays

    Created Crosshair for PDC curves (including value representation on axis)

    Enhanced Solid State Breaker curve preview

    C. Arc Flash Study

    Increase the Arc flash constraint limit on looking for upstream protec tion devices

    Enhanced the Arc Flash calculation wizard based on selected bus Arc flash labels always presents System Voltage rather than LF voltage when the

    SC Calculated by LF pre-fault voltage

    D. Harmonic Analysis

    Applied the last slope fac tor to extrapolate resistance R for frequency scanning

    Added On/Off option for Harmonics status

    Applied scenarios to control On/Off for harmonic sources

    E. AC/DC Power Flow

    New 3P Inverter and DC Source Models

    Enhanced the calculation for DC Current Control and voltage c ontrol for

    Rectifiers

    F. Ground Grid Program

    Added Undo/Redo commands

    Added Lock/Unlock features

    User Interface improvements

    Increased the dec imal numbers in the output report

    G. Advanced Power Cable Ampacity

    Feature to save units when c hanged from main window

    H. Advanced Transient Stability Analysis

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    5/60

    What is New in Paladin DesignBase 5.0 SP2

    5

    Re str i c ted to Powe r A na lyt i c s Partners | Do No t D ist ribute

    Increased the limit of Variable shown in the results for general-

    models/AVR/Governor/PV models

    Enhanced simulation window to show information about events occurring

    Showed more decimal numbers for PU values in order to generate smoother

    curves

    On/Off status of General Models based on device status in different scenarios

    Added Signal monitoring tab feature to General Models

    I. And Much More

    User interface improvements

    Error Checker reports improvements

    Text Editor spread-sheet view improvements

    Added two new features (Adobe Reader and XPS Viewer) in Text Report

    program

    Added backup/ restore options for project folder/library files

    Unzip project without having WINZIP/WINRAR

    Created a new DC Source symbol in DC catalogs

    Created a new Inverter symbol in 3P Bus catalogs

    Added a new shunt capacitor symbol in all the bus catalogs

    Added new options in Import/Export Programs

    Lists complete descriptions for installed DB license features

    Added a port number field to C lient License Manager

    The evolution towards Paladin DesignBase 5.0 Service pack 2 represents millions of dollars

    and many years of development effort, not only by our on-staff development team, but

    by users like you who provide us with valuable guidance on new features and functions.

    We thank you for your continued business, and for making Paladin DesignBase the most

    effective and productive modeling platform in the mission-critical arena.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    6/60

    What is New in Paladin DesignBase 5.0 SP2

    6

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    Contents

    A. Short Circuit Program ................................................................................................................................... 8

    1) Bus Selection New Features of 3 Phase Short Circuit Programs .............................................................. 8

    2) Save/Import Bus Selection in User Defined Text File ............................................................................ 10

    3) Report to CSV file in Detailed Report of IEC363 SC Program ................................................................. 14

    4) Add new DC Source for calculations and build the estimation method based on IEC61660. ............... 14

    5) New DC Source for Classical Methodology ............................................................................................ 16

    B. Protection Device Coordination ................................................................................................................. 17

    1) Adjust Bus curve length in PDC TCC ....................................................................................................... 17

    2) Show/Hide coordinate symbol .............................................................................................................. 18

    3) Add device curve text in PDC program .................................................................................................. 20

    4) Enhancement for the PDC "Restore View" icon in PDC toolbar ............................................................ 20

    5) Creating on/off icon for Opening/Closing the PDC tool-box ................................................................. 21

    6) On/Off for Designed Load Amp part of Bus Curve in PDC TCC .............................................................. 21

    7) Transformer Damage Curve Updates according to IEEE C57.12.59-2001 ............................................. 23

    8) Show coordinates when moving each PDC curve's arrow in PDC program .......................................... 24

    9) Add "delete" option for elements in PDC study to prevent Appending to wrong Study ...................... 24

    10) Append new component into existing PDC studies .......................................................................... 25

    11) Add options for deleting one or more PDC studies ........................................................................... 26

    12) Add a searching feature for equipment name in multiple PDC studies ............................................ 27

    13) Creating Crosshair for PDC curves (including value representation on axis) ..................................... 28

    14) Digitizer usability improvements. ...................................................................................................... 29

    15) Enhanced Solid State Breaker curve preview .................................................................................... 30

    C. AC & DC Arc Flash Evaluation..................................................................................................................... 32

    1) Increase the Arc flash limitation limit on looking for upstream protection devices ............................. 32

    2) Enhancing the Arc flash calculation wizard based on selected bus ....................................................... 33

    3) Arc flash labels should always present System Voltage rather than Load Flow voltage when the SC

    Calculated by LF pre-fault voltage ................................................................................................................. 33

    D. Harmonic Analysis ...................................................................................................................................... 35

    1) Added on/off option for harmonic sources ........................................................................................... 35

    2) Apply scenarios to control on/off for harmonic sources ....................................................................... 35

    E. AC/DC Power Flow ..................................................................................................................................... 36

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    7/60

    What is New in Paladin DesignBase 5.0 SP2

    7

    Re str i c ted to Powe r A na lyt i c s Partners | Do No t D ist ribute

    1) Enhanced the Calculation of DC Current Control in Rectifiers .............................................................. 36

    2) Sample to simulate AC-DC network for both SC and Load Flow ............................................................ 37

    F. Ground Grid Program ................................................................................................................................. 44

    1) Undo/Redo functions ............................................................................................................................. 44

    2) Lock and Unlock functions ..................................................................................................................... 44

    3) Spreadsheet view of grid elements ....................................................................................................... 45

    G. Advanced Power Cable Ampacity .............................................................................................................. 46

    H. Advanced Transient Stability ..................................................................................................................... 47

    1) New features for results of general-models/AVR/Governor/PV models .............................................. 47

    2) Relating General Models on/off based on device status in different scenarios .................................... 48

    3) New features for simulation windows ................................................................................................... 49

    I. Miscellaneous Features ............................................................................................................................. 50

    1) Client License Manager .......................................................................................................................... 50

    2) Add two new Text Report browser for Adobe Reader and XPS Viewer ................................................ 52

    3) Add Backup/Restore options for project folder/library files and both together ................................... 53

    4) Unzip project without having WINZIP/WINRAR .................................................................................... 55

    5) Create a Upgrade all the PA sample files icon after installing DB5 SP2 ............................................. 55

    6) Editor and Text Editor Usability improvements. .................................................................................... 56

    7) Error Checker Enhancements: ............................................................................................................... 57

    8) Add Case Study list box, Add icon and Delete icon in Short Circuit toolbar .......................................... 58

    9) Other Miscellaneous Enhancements: .................................................................................................... 59

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    8/60

    What is New in Paladin DesignBase 5.0 SP2

    8

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    A. Short Circuit Program

    1) Bus Sele c tion Ne w Fea tures of 3 Pha se Sho rt Circ uit Prog ram s

    This feature gives the user an option to select buses either from drawings or from the

    buses saved in the short circuit program:

    Open the sample file IEC-YY projec t file. (ie: C:\ DesignBase5\ Samples\ 3PhaseSC)

    Choose one of AC 3ph SC methods:

    - AC ANSI/IEEE

    - AC Classical

    - AC IEC 60909

    - AC IEC 61363

    In this example we selected AC Classical:

    Select number of buses from the drawings (In this example BUS 1, PPC 3, G1)

    Open SC Option dialog box and see which buses were selected (In this example

    BUS 1, PPC3, G1) from the drawings in the list, since the default option From

    Current Page is selec ted.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    9/60

    What is New in Paladin DesignBase 5.0 SP2

    9

    Re str i c ted to Powe r A na lyt i c s Partners | Do No t D ist ribute

    Switch to option From Saved to ensure saved buses are showing in the list (In this

    example BUS 1, PPC 3, G1).

    Switch back to From current Page and the buses selected from the drawings will

    be displayed (In this example buses A4P, A7P, A8P, BUS 1, ).

    Add buses from All Filtered Buses list (In this example A3CP, A4P, BUS 1, PPC3, G1)

    and c lick Save button.

    Switch to option From Saved and notice the buses in the list stay the same.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    10/60

    What is New in Paladin DesignBase 5.0 SP2

    10

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    Switch back to From current Page and the buses selected from the drawings

    are back on the list (In this example BUS 1, PPC3, G1).

    Switch to option From Saved again, click OK to go back to the drawing and you

    will see the nodes A3CP, A4P are selected besides BUS 1, PPC3, G1.

    2)

    Sa ve / Imp ort Bus Sele c tion in User De fine d Tex t File

    Open the IEC-YY project file. (ie: C:\ DesignBase5\ Samples\ 3PhaseSC)

    Choose one of the AC 3ph SC methods:

    - AC ANSI/IEEE

    - AC Classical

    - AC IEC 60909

    - AC IEC 61363

    In this example we selected AC Classical:

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    11/60

    What is New in Paladin DesignBase 5.0 SP2

    11

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    Select Selected Buses option and select some buses (In this example BUS 1, Bus

    2, G1, G2)

    Select the Export button and export the list to the text file (SCBusList.txt)

    This file will keep the selected bus list which you may import anytime to do SC

    study.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    12/60

    What is New in Paladin DesignBase 5.0 SP2

    12

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    Continue with SC study and generate the results (V4Results.txt)

    Close the software

    Launch DesignBase

    Run the SC program (AC Classical)

    Use the selec ted Buses and the Import option to open from the selec ted bus list

    (SCBUSLIST.txt)

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    13/60

    What is New in Paladin DesignBase 5.0 SP2

    13

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    14/60

    What is New in Paladin DesignBase 5.0 SP2

    14

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    3) Rep o rt to CSV file in Deta iled Rep ort o f IEC363 SC Prog ram

    Now users can export the Detailed Report as a CSV file in SC IEC363:

    4) Ad d ne w DC Source for ca lcu la t ions and bui ld the est im at ion me thod b ased on

    IEC61660.

    This new feature includes a new model for DC sources according to IEC61660:

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    15/60

    What is New in Paladin DesignBase 5.0 SP2

    15

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    The Short Circuit page should be set by considering the following items:

    SC Rating could be either Rated Amps or rated kW.

    DC Smoothing Reactor Data is the same as Rectifier in IEC61660 standard

    AC Impedance data is the equivalent impedance converted to AC low voltage

    side. The values can be entered manually or calculated from Maximum SC current

    at the terminal bus to match IEC 61660 standards as follows

    =6 1000

    (. 13660 1)

    Iscmaxcan be entered directly or calculated from Rated Amps and SC factor Ksc.

    Estimate Rac button is used to estimate AC Impedance with Rac/Xac fixed

    Running the DC IEC61660 SC program will result to the following report:

    - - - - - - - - - - - - - - - - - - - - - - -Recti f i er( s) Dat a

    - - - - - - - - - - - - - - - - - - - - - - -AC Ci r cui t Si de DC Ci r cui t

    Syst em Act ual Rat ed - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Bus Name V V Cd A Z- mOhm R- mOhm L- mH R- mOhm L- mH- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -DCS 250 250 DS 2000 4. 0760 2.3541 0. 0106 98. 68 0. 0300

    Which means : Rac = 2.354 mOhms

    The Analyze button will generate Output Branch Results Reports:

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    16/60

    What is New in Paladin DesignBase 5.0 SP2

    16

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    - - - - - - - - - - - - - - -Bus Resul t s

    - - - - - - - - - - - - - - -

    Sust ai n Peak Peak Ri si ng Decl i neTheveni n I k I p Tp T1 T2 Rat e of Ri se

    Bus Name Cd R( Ohm) L ( mH) A A mSec mSec mSec A/ mSec

    - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -DCS DS 0. 0833 0. 3389 3000 3000 12. 20 4. 07 100. 00 738F1 0. 0833 0. 3389 3000 3000 12. 20 4. 07 100. 00 738

    The contribution of dc Source DCS Ik= 3000 A ,which will match the value in the editor as

    expected.

    5) New DC Source for Classica l Me thodo logy

    A new DC source which has discussed before is also verified to cover DC Classical ShortCircuit method.

    The editor of this new DC source model includes the same data as the rectifier.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    17/60

    What is New in Paladin DesignBase 5.0 SP2

    17

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    B. Protection Device Coordination

    1) Ad just Bus curve leng th in PDC TCC

    The length of a Bus curve can be adjusted by dragging the handle at the bottom of the

    Bus curve.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    18/60

    What is New in Paladin DesignBase 5.0 SP2

    18

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    2) Show / Hide c oo rd inate sym bo l

    The coordinate symbols can be shown by right-clicking "Show/Hide Coordinate" menu

    item on the TCC window and then selec ting Yes in the following dialog box.

    The coordinate symbol can be hidden again by right-clicking "Show/Hide Coordinate"

    menu item on the TCC window and then confirming in the appeared dialog box.

    The coordinate

    symbol will be

    shown

    Right Click

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    19/60

    What is New in Paladin DesignBase 5.0 SP2

    19

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    Create multiple coordinate symbols in PDC curves

    The new multiple coordinate symbols can be created by right-clicking the Insert

    Coordinate menu item on TCC window and then selecting Yes in the following dialog

    box.

    Multiple

    coordinate

    symbols

    Right Click

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    20/60

    What is New in Paladin DesignBase 5.0 SP2

    20

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    3) Ad d dev ice c urve tex t in PDC program

    The multiple annotation symbols can be dragged from the Annotation catalog into TCC

    view.

    4) Enha nc em ent for the PDC "Restore View" ic on in PDC too lba r

    In the PDC toolbar, the Restore View icon is only shown when showing the PDC study

    and the Show Study icon is only shown when not showing the PDC study. The zoom of

    the main drawing is kept as the same as before anything was changed after clicking

    Show Study icon and then clicking Restore View icon.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    21/60

    What is New in Paladin DesignBase 5.0 SP2

    21

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    5) Creat ing on/ of f icon for Ope ning/ Closing the PDC tool-box

    After clicking the Show/Hide Symbol Catalogs icon, the catalog window will appear.

    After clicking the Show/Hide Symbol Catalogs icon again, the catalog window will

    disappear.

    6) On/ Off for Designe d Loa d Am p p a rt of Bus Curve in PDC TCC

    When unchecking the Hide Design Load Amps check box in the following Bus Curve

    dialog box, the Bus design load amps will be shown in TCC view below. This option is

    designed to show or hide the Bus design load amps in TCC view.

    Show/Hide

    Symbols

    Catalogs

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    22/60

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    23/60

    What is New in Paladin DesignBase 5.0 SP2

    23

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    7) Transform e r Dam ag e Curve Upd a tes a c c o rding to IEEE C57.12.59-2001

    When the cooling type is a Dry-Type and the transformer belongs to categories I or II, IEEE

    CS7.12.59-2001 standard c an be selec ted in the following dialog box.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    24/60

    What is New in Paladin DesignBase 5.0 SP2

    24

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    8) Show c oo rd inates when m oving e ac h PDC c urve 's arrow in PDC program

    When holding down each PDC curves arrow and moving it, the coordinate values will

    be shown in the Toolbar.

    9) Ad d "dele te" opt ion for e lem ents in PDC study to p reve nt App end ing to wrong Study

    In a PDC single line page, after selec ting the elements in a PDC study then pressing

    Delete button, the following dialog box will be shown to ask whether or not to delete the

    study.

    Hold downPDC

    Curves arrow

    and move it

    Watch

    coordinate

    values

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    25/60

    What is New in Paladin DesignBase 5.0 SP2

    25

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    10 )Ap pe nd new c om po nent in to ex ist ing PDC stud ies

    Add new elements into existing PDC by appending them into a corresponding PDC

    study:

    Existing PDC Study

    Select new elements and then

    Append to the existing PDC study

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    26/60

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    27/60

    What is New in Paladin DesignBase 5.0 SP2

    27

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    12 )Ad d a sea rc h ing fea ture for eq uipm ent nam e in m ul tip le PDC stud ies

    After clicking Edit/Search Equipment in PDC Studies menu item in PDC toolbar, the

    following dialog box will be shown. All the selec ted equipment on the left side is

    included in the selec ted PDC study on the right side.

    When searching for one or more equipment name in multiple PDC studies in the above

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    28/60

    What is New in Paladin DesignBase 5.0 SP2

    28

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    dialog box, the equipment found in each PDC study will be shown below:

    13 )Crea ting Crossha ir for PDC c urves (includ ing va lue rep resentat ion o n a xis)

    By holding down the arrow handle of the c oordinate symbol and moving it, the following

    crosshair will automatically be shown. By releasing the arrow handle of the coordinatesymbol, the crosshair will automatically disappear.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    29/60

    What is New in Paladin DesignBase 5.0 SP2

    29

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    The coordinate values will be shown in Toolbar and TCC view below.

    14 )Dig it izer usab i li ty imp rovem ents.

    The Digitizer program has been enhanced to return to the build program by pressing the

    new Return to Build Program button in the Digitizer. The Digitizer minimizes and returns you

    to the build program. From there the user can continue editing the same curve or edit a

    different curve.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    30/60

    What is New in Paladin DesignBase 5.0 SP2

    30

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    15 )Enha nc ed Solid State Break er c urve preview

    A new curve preview has been created for enhancing the usability of Solid State Breakers

    which now includes Long and Short Time Pickup and Instantaneous Pickup all in the same

    diagram:

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    31/60

    What is New in Paladin DesignBase 5.0 SP2

    31

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    Other features included in PDC Program are:

    - Updated G&W relays

    - Shows bus name in PDC single line

    - Does not show PDC drawings in the page drop down menu

    - Sort PDC study name in the PDC toolbar

    - Addition of two new features to change pen thickness and order of the user defined

    SC arrows

    - Automatic addition of buses to PDC Studies when a branch is selected

    - Enhanced Relay Program user interface

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    32/60

    What is New in Paladin DesignBase 5.0 SP2

    32

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    C. AC & DC Arc Flash Evaluation

    1) Increa se the Arc flash l im ita t ion l imit on loo king for upstrea m protec t ion d evic es

    The maximum fault contribution levels will be available for users to set. Its default value is 10

    and can be increased up to 20 branches in upstream circuit. The user can set this value

    based on his protection strategy and size of the network and the calculation speed on the

    computer. This will update short circuit and PDC studies for contribution levels

    automatically. This setting means every bus/equipment should be protected by a device in

    at most 20 levels up branches.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    33/60

    What is New in Paladin DesignBase 5.0 SP2

    33

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    2) Enhanc ing the Arc f lash ca lcu la t ion w izard b ased o n selec ted b us

    This feature will automatically recalculate and show the results of the selected bus. The

    user can change the selected bus in Show Bus and arc flash engine will automatically

    calculate and show the results in this window.

    3) Arc fla sh lab els should a lwa ys p resent System Voltag e rathe r tha n Loa d Flow v oltag e

    whe n the SC C alc u la ted by LF pre-fau l t vo l tag e

    When the Short Circuit Calculation uses Power Flow Voltage as pre-fault voltage, then

    all calculations will be based on Load flow voltage as a pre-fault and the Arc-Flash

    Engine would also use this voltage which might be different from system voltage. To keep

    the system data consistent, Arc-Flash labels should present System Voltage rather than

    what the user considered in SC calculations. Labels are a lways present in System Voltage

    but Arc-Flash report still will show LF voltage as a pre-fault voltage.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    34/60

    What is New in Paladin DesignBase 5.0 SP2

    34

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    35/60

    What is New in Paladin DesignBase 5.0 SP2

    35

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    D. Harmonic Analysis

    1) Ad de d on/ of f op t ion for harm onic source s

    This feature creates new option for the user to be able turn on/off harmonic sources in a

    study.

    2) Ap ply scena rios to c ontro l on/ of f for harmo nic source s

    In addition we applied this option to c ontrol harmonic sources on/off feature by

    Scenarios.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    36/60

    What is New in Paladin DesignBase 5.0 SP2

    36

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    E. AC/DC Power Flow

    1) Enha nc ed the C a lculat ion o f DC C urrent C ontrol in Rec tif iers

    The DC load flow now includes the DC current control order with Zero Amp for the RatedCurrent.

    In addition, a Warnings message will be generated if Rec tifier DC Voltage Control Order

    Is set to Zero after running DC Load Flow Report Manager\ Log File:

    Bus Source < REC1>:

    System Voltage is applied for DC Control Voltage Order due to it

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    37/60

    What is New in Paladin DesignBase 5.0 SP2

    37

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    2) Sam p le to simula te AC -DC netw ork for bo th SC a nd Loa d Flow

    Service Pack 2 also includes new symbols and settings to ease the modelling of

    integrated AC -DC networks. This sec tion will present how to model this kind of network

    with a simple example as shown below for a typical AC/DC configuration.

    The sample file can be accessed from: C:\ DesignBase5\ Sam pe ls\ ACDCLF\ AC_DC_Conver ter .ep r

    Modelling in DesignBase:

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    38/60

    What is New in Paladin DesignBase 5.0 SP2

    38

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    - DC-AC Devic e ( Inverter)

    As shown in the drawing OCC-4WI is an inverter with two components connec ted to the

    DC and AC networks separately. The inverters DC Component which is connec ted to

    the DC side should be dragged and dropped from the DC catalog.

    This component can be controlled as DC Current Control or DC Voltage Control

    which can be set in its Load Flow tab page. It works as a bus for Short Circuit studies.

    The AC C omponent works as a Source on the AC Side and it should be dragged from

    AC catalog by looking for Inverter symbol.The AC component should have the samename as the DC component:

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    39/60

    What is New in Paladin DesignBase 5.0 SP2

    39

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    For Short Circuit studies this should be set as a Current Limitation Source which can be

    calculated from Rated Parameters. For load flow the PG should be set to zero and PL

    should be non-zero in order to pass the DC control from DC component. (PG=0, PL0)

    - AC -DC Bi-Direc t iona l Co nve rter

    As shown in the main drawing OCC-GTI is a bidirec tional converter:

    The bi-directional model includes two different modes: a rectifier mode and an inverter

    mode. Each mode is modeled by different components for AC and DC sides separately

    and should be ac tivated individually by defining the two different scenarios.

    The inverter mode includes the same components which are described above by using

    the same name for both components. (in this example the AC Source and it is

    deac tivated in the current scenario were used)

    In the rectifier mode the DC side is modeled with a DC Source (rec tifier) and the AC side

    is modeled with an AC load which can be dragged from AC catalog by looking for

    Rectifier Symbol. Both components should have the same name. ( This example used DC

    Source).

    The AC component is a Bus for Short Circuit Studies. For load flow study its kvar should be

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    40/60

    What is New in Paladin DesignBase 5.0 SP2

    40

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    set at Zero in order to accept the current control results from DC side.

    The DC component is also set as a DC Source on the DC Side and can be dragged from

    the DC catalog by looking for the DC source.

    For Short Circuit Studies, its SC Current can be limited and is estimated by AC impedancefrom the Rated Parameters per IEC61660 standard. For load flow standards the DC

    Control should be set either to Current Control or Voltage Control and by using the

    same name as the AC side Rectifier Load it can pass the control parameters to the AC

    side.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    41/60

    What is New in Paladin DesignBase 5.0 SP2

    41

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    - DC-DC C onve rter

    As shown in the drawing OCC-DCDC is a DC converter with two components connected

    with LV=120 V and HV=240V sides.

    A DC-DC converter can be dragged from the DC catalog. There is no meaningful data

    for the branch since the two voltage networks are isolated from eac h other in the real

    world.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    42/60

    What is New in Paladin DesignBase 5.0 SP2

    42

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    The HV Source can be dragged just by selecting a DC Source from the DC c atalog. Its

    Short Circuit Current can be limited by using an estimation of AC impedance from the

    Rated Parameters per IEC61660 standard. For the load flow it should be set to DC

    Current Control with zero Amps in order to pass the control from LV to HV

    Selec t Current C ontrol and set Order =0 to transfer the power from LV side.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    43/60

    What is New in Paladin DesignBase 5.0 SP2

    43

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    - Sc ena rios need to be de f ined :

    Scenarios can be used to switch the status of the bidirectional converter.

    Rec tif ier Mod e

    AC Source is switched off and DC Source is activated to pass the power from AC to DC.

    Inverter Mod e

    DC Source is switched off and AC Source is activated to pass the power from DC to AC .

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    44/60

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    45/60

    What is New in Paladin DesignBase 5.0 SP2

    45

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    3) Sp read shee t view o f grid elem ents

    New buttons for adding new elements and a lso a selection option either from spreadsheet

    selection or from diagram have also been added.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    46/60

    What is New in Paladin DesignBase 5.0 SP2

    46

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    G. Advanced Power Cable Ampacity

    Cable Ampacity Program is enhanced to show diagram units now and it can be changed

    through the main windows rather than the project setting dialog.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    47/60

    What is New in Paladin DesignBase 5.0 SP2

    47

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    H. Advanced Transient Stability

    1) New fea tures for results of gen eral-m od els/ AVR/ Go ve rnor/ PV mo d els

    In the new version of the advanced transient software, the limit of the variable shown in

    the results for general-models/AVR/Governor/PV models has been increased by up to

    44 signals.

    User can select View Graphical Results and under the UDM tab (new feature to show user

    defined model variables) he/she will be able to select desired number of signals to be

    plotted.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    48/60

    What is New in Paladin DesignBase 5.0 SP2

    48

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    2) Rela t ing G ene ra l Mo de ls on/ off ba sed on d ev ice status in different sc ena rios

    To prevent the software from creating an error message when its associated bus/branch isout of service in the single line (in current scenario), an automatic updatable on/off status

    has been added:

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    49/60

    What is New in Paladin DesignBase 5.0 SP2

    49

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    3) New features for simu lat ion wind ow s

    In order to enhance the transient simulation windows, an Event Log window has been

    added to the main windows to show a list of events that happen during simulation based

    on View Text Results. In addition, the main windows curves have been generated by

    more decimal values to show a smoother curve for voltage PU and frequency values:

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    50/60

    What is New in Paladin DesignBase 5.0 SP2

    50

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    I. Miscellaneous Features

    1) Cl ient Lice nse Ma nag er

    The serial number will be shown in the Client License Manager page if there is a serial

    number in the license file. The new four CORE, SUPER, POWER and PE license packages will

    be shown if one of those license packages exists in the license file.

    The port number can be changed and can be changed bac k after clicking the Defaultbutton in the following dialog box. The default port number is 27002 when using the license

    server.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    51/60

    What is New in Paladin DesignBase 5.0 SP2

    51

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    By clicking the Show License Information button in the client license manager dialog box,

    the complete descriptions for the installed DB license features and package name will be

    shown as follows:

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    52/60

    What is New in Paladin DesignBase 5.0 SP2

    52

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    2) Ad d tw o ne w Text Rep ort browser for Ad ob e Rea d er and XPS View er

    Launch the Text Report program by selec ting Tools/Global Edits/Change the settings for

    the Text Report as follows:

    Two new formats including Adobe Reader and XPS Viewer have been added. The current

    settings such as font size, font color, watermark, and so on for Adobe Reader and XPS

    Viewer can be c hanged when clicking the Change C urrent Settings button.

    For example, when changing the font color to blue and watermark to DRAFT, saving the

    settings and then selecting Adobe Reader as a browser, the PF report will be created as

    follows:

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    53/60

    What is New in Paladin DesignBase 5.0 SP2

    53

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    In the same way, when changing the font color to red and watermark to SAMPLE, saving

    the settings and then selec ting XPS Viewer as a browser, the PF report will be created as

    follows:

    3) Ad d Bac kup / Restore op t ions for pro jec t fo lder/ l ib rary f iles and bo th together

    When selecting File/ Backup Library Files in DB5 SP2, the following dialog box will beshown. All the selected library files can be zipped to a backup file. The default path to the

    backup files is C:\ DesignBase5\ Bac kUp. All the selected options from the Data folder and

    can also be browsed from different locations.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    54/60

    What is New in Paladin DesignBase 5.0 SP2

    54

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    When selec ting File/ Restore Library Files in DB5 SP2, the following dialog box will appear.

    All the files in the selected zip file will be unzipped to the selected folder when clicking

    Restore button in the following dialog box.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    55/60

    What is New in Paladin DesignBase 5.0 SP2

    55

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    4) Unzip p rojec t w ithout ha ving WINZIP/ WINRAR

    By Selecting File/Unzip Project the user can select any packed folder including the

    projec t files into the current folder. Following dialog box will be shown which show the path

    of packed folder.

    5) Cre a te a Up g rad e a ll the PA sam p le files ic on a fter insta lling DB5 SP2

    After installing DB5 SP2, a Upgrade all the PA sample files icon is created. By clicking this

    icon, all the sample files under c:\ designbase5\ samples folder will be upgraded:

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    56/60

    What is New in Paladin DesignBase 5.0 SP2

    56

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    6) Ed itor and Tex t Ed itor Usa b ility im p rovem en ts.

    All Text Editor equipment filters can be edited.

    The user can select and copy/paste in the Text Editor Spreadsheet:

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    57/60

    What is New in Paladin DesignBase 5.0 SP2

    57

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    Periodic field entry as spreadsheet for AC Voltage Profile:

    7) Error C hec ke r Enha nc em ents:

    Error Checker reports Harmonic devices which are not connec ted to network and

    harmonic devices which are connected to an unpowered island.

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    58/60

    What is New in Paladin DesignBase 5.0 SP2

    58

    Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute

    Error Checker can now correc t certain errors automatically. The user can Right-Click on the

    highlighted entries to open the menu, and c hoose to correc t the single error or all similar

    errors.

    8) Ad d C a se Study l ist box , Ad d ic on a nd Delete ic on in Short Circuit too lba r

    If the Case Study for the Options with @ in the SC option dialog box checked, the C ase

    Study list box, Add icon, and Delete icon will be created in the Short Circuit toolbar as

    follows:

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    59/60

    What is New in Paladin DesignBase 5.0 SP2

    59

    Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute

    The case study name is listed in Case Study list box. Different case study names can be

    selected. When clicking Add icon (or +), a case study can be added. When clicking

    Delete icon (or X), a case study can be deleted.

    By unchecking Case Study for the Options with @ in the SC option dialog box, the Case

    Study list box, Add icon, and Delete icon will disappear in Short Circuit toolbar as follows:

    9) Othe r Misc el lane ous Enha nc em ents:

    - User interface improvements

    - Created a new DC Source symbol in DC catalogs

    - Created a new Inverter symbol in 3P Bus catalogs

    - Added a new shunt capacitor symbol in all the bus catalogs

    - Added new options in Import/Export Programs

  • 8/10/2019 What is New in DesignBase 5.0 SP2

    60/60