what is soft, sensitive, and great for measuring ......the koala’s amnioinfusion port has a...

2
Catheter Ordering Information Koala Intrauterine Pressure Catheter IPC-5000E 10 catheters/box Cable Ordering Information Philips Medical All Models (except below) IPC-5012 8040A (40μV/V/mmHg) IPC-5018 Avalon IPC-5080 GE Medical (Corometrics) All Models IPC-5014 Air-Shields (Litton) Fetascan 1400 IPC-5016 Oxford Medical All Models IPC-5020 Spacelabs Medical (AMS) Spacelabs 94000 IPC-5050 Neovanta Medical Stan S31 IPC-5060 All others including AMS models IPC-5016 Clinical Innovations, LLC 747 West 4170 South Murray, Utah 84123 www.clinicalinnovations.com Phone: (801) 268-8200 Fax: (801) 266-7373 Toll Free: (888) 268-6222 E-mail: [email protected] US Patents 5,573,007; 5,951,497; 6,231,524 and other patents pending. © Copyright 2008 Clinical Innovations, LLC P/N 056-0006 Rev. F What is soft, sensitive, and great for measuring intrauterine pressure? No Latex No DEHP No PVC

Upload: others

Post on 11-Jun-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: What is soft, sensitive, and great for measuring ......The Koala’s amnioinfusion port has a hydrophobic cap and a tethered replacement cap. The amnioinfusion lumen and sensor-charging

Catheter Ordering InformationKoala Intrauterine Pressure Catheter IPC-5000E10 catheters/box

Cable Ordering InformationPhilips MedicalAll Models (except below) IPC-50128040A (40µV/V/mmHg) IPC-5018Avalon IPC-5080

GE Medical (Corometrics)All Models IPC-5014

Air-Shields(Litton) Fetascan 1400 IPC-5016

Oxford Medical All Models IPC-5020

Spacelabs Medical (AMS) Spacelabs 94000 IPC-5050

Neovanta MedicalStan S31 IPC-5060

All others including AMS models IPC-5016

Clinical Innovations, LLC747 West 4170 SouthMurray, Utah 84123www.clinicalinnovations.com

Phone: (801) 268-8200Fax: (801) 266-7373

Toll Free: (888) 268-6222E-mail: [email protected]

US Patents 5,573,007; 5,951,497; 6,231,524 and other patents pending.

© Copyright 2008 Clinical Innovations, LLCP/N 056-0006 Rev. F

What is soft, sensitive,and great for measuringintrauterine pressure?

No LatexNo DEHP

No PVC

Page 2: What is soft, sensitive, and great for measuring ......The Koala’s amnioinfusion port has a hydrophobic cap and a tethered replacement cap. The amnioinfusion lumen and sensor-charging

Circumferential Sensoronon-occluded, 360 readings

for

The Koala’s amnioinfusion port has a hydrophobic cap and a tethered replacement cap.� The amnioinfusion lumen and sensor-charging lumen are two

separate channels so each can perform its function accurately

Convenient Amnioinfusion

The Koala has no electronics in the catheter, allowing for a smaller, rounder catheter that is easy to place.� A round catheter is less likely to slide down, or even out, with the baby during labor� No electronics in the catheter also means no “thermal drift”, or no variation in readings

by change from room to body temperature

Small, Round Catheter for Easy Placement

The Koala is made and packaged to properly achieve fundal placement.� Stiffness enables easier insertion and placement in upper fundus� Unique U-shape provides easy-to-place catheter memory, eliminating

excessive bending and “pretzel” twisting

Packaged with “U” in Mind

oThe Koala’s sensor registers pressure 360 , not just one direction.� Sensor is not easily occluded by maternal or fetal tissue� Local forces on the sensor have little effect on the function of the

catheter

Circumferential Sensor for Accuracy

The Koala’s transducer is located in the reusable cable, ensuring accurate and reliable readings.� Clinician can disconnect catheter while it is in the uterus and zero the monitor

while the transducer is exposed to atmospheric pressure, providing a true zero reading� Eliminates negative numbers, common with other catheters, due to improper

electronic zeroing

External Transducer for True, Easy Zeroing

Proper placement is confirmed when amniotic fluid is seen flowing back down the catheter

The Koala has a clear catheter lumen to confirm proper placement via amniotic fluid flashback.

Clear Lumen for Confirmationof Proper Catheter Placement

? Proper placement in the amniotic space is key for safe and accurate IUP monitoring� Amniotic fluid flowing back down the catheter confirms

placement in the amniotic space� Frank, red blood flowing back down the catheter

confirms placement outside the amniotic membranes and requires catheter redirection or replacement

Obtain a true zero by disconnecting the catheter and exposing the transducer to atmosphere

The Koala’s small tip is made of soft, malleable urethane. � Soft tip “mushrooms” in shape when pressed against a surface? Mushrooming effect decreases risk of placental perforation,

increasing the safety for mother and baby

Soft Tip for Safe Insertion

The mushroom effectof the Koala’s soft tip

Your complete tool to systematically eliminate IUP inaccuracies.

NO LATEX NO DEHP NO PVC