what’s new high- optional new dds (direct digital synthesizers)...

13
EVOLVING ACTIVE COMPONENT MEASUREMENT SOLUTIONS New DDS (direct digital synthesizers) source improving: phase noise by 30 dB measurement performance of apps: SMC+phase, differential-IQ, modulation distortion, NVNA, iTMSA, IMD dynamic range in sub-THz bands by 30 dB High-performance analog-SigGen-class low phase noise (Option UNY, Enhanced low-phase noise) 3rd RF source up to 13.5 GHz on 4-port PNA-X High- performance analog SigGen class phase noise Optional 3rd RF Source What’s NEW

Upload: others

Post on 29-Jan-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

  • 1

    E V O LV I N G A C T I V E C O M P O N E N T M E A S U R E M E N T S O L U T I O N S

    ▪ New DDS (direct digital synthesizers) source

    improving:

    • phase noise by 30 dB

    • measurement performance of apps: SMC+phase, differential-IQ, modulation distortion, NVNA, iTMSA, IMD

    • dynamic range in sub-THz bands by 30 dB

    ▪ High-performance analog-SigGen-class low phase

    noise (Option UNY, Enhanced low-phase noise)

    ▪ 3rd RF source up to 13.5 GHz on 4-port PNA-X

    High-

    performance

    analog

    SigGen

    class phase

    noise

    Optional

    3rd RF

    Source

    What’s NEW

  • 2

    G E T T H E R E S O L U T I O N Y O U N E E D

    New DDS Source

    High-performance analog-

    signal-generator grade phase

    noise helps you to save your

    test time and simplify your

    test configuration.

    More sources

    The third RF source on 4-

    port PNA-X simplifies

    measurement configuration

    for complex measurements

    and save bench footprint.

    Applications

    Modulation distortion

    application helps you to

    measure EVM/NPR of

    amplifiers, mixers and

    frequency converters.

  • 3

    C H A L L E N G E S M E T – N O N E E D F O R H I G H - P E R F O R M A N C E S I G G E N

    New PNA/PNA-X Option UNY

    PSG

    PSG–UNY- mode 1

    Current PNA/-X

    Export control limit

    • Eliminates the need for external

    high-performance analog signal

    generators for the use of LO or

    where low-phase noise is needed.

  • 4

    C H A L L E N G E S M E T - M O R E T H A N 5 0 T I M E S FA S T E R !

    Current PNA Enhanced PNA with new DDS synthesizers

    Frequency: 20 GHz, Span: 2 GHz, IFBW: 10 kHz

    SMC+Phase measurement - Data deviation from linear phase

    4.5 seconds with averaging 0.1 seconds with no averaging

    Today’s instruments test quickly but increase uncertainty, now you can measure faster

    without sacrificing accuracy

    To get the same stable phase measurement, it takes

  • 5

    • Reliable, repeatable measurements at

    higher frequencies with 30 dB more

    dynamic range in sub-THz measurements (using the new PNA, the N5292A test set, and

    frequency extenders)

    B E T T E R P E R F O R M A N C E I N T H Z

    Dynamic range improvement

    from 750 GHz to 1.1 THz

  • 6

    • Complex measurements require

    multiple instruments, but the 3rd source

    eliminates the need for an external

    signal generator for mixer IMD

    measurements

    • Three high-performance analog signal

    generators

    • Can be used as an independent signal

    generator.

    C H A L L E N G E S M E T – S Y S T E M S I M P L I F I C AT I O N

    Note: The 3rd source is available only with 4-port PNA-X.

    3rd Source

    IMD

    OutputIMD

    Input

  • 7

    C H A L L E N G E S M E T - P E R F O R M A W I D E VA R I E T Y O F T E S T S

    • Gain compression

    • SMC+Phase

    • Modulation distortion

    • Differential I/Q

    • IMD

    • SA and NPR

    • Noise figure

    • Nonlinear Vector Network Analysis (NVNA) /X-

    parameters

    • PLTS

    • Real-time S-parameter and power uncertainty

    • Source-phase control for active-load pull

    • Active-hot parameters

    • and more…

    DDS improves the measurement performance of applications where the phase measurement stability is critical.

    Stable phase measurement

    with enhanced PNA

  • 8

    Best solution for amplifier characterization!

    S I M P L I F I E S Y O U R A M P L I F I E R T E S T

    EVM, NPR and ACPR measurements

    under modulated stimulus conditions

    without doing demodulation

    • Lowest residual EVM and NPR

    • Faster measurements than SA

    • Better accuracy and

    reproducibility

    • Simple and intuitive

    • System simplification

    • No analysis bandwidth restriction

    Launched in June 2019

    mmW

    frequency

    Extremely

    Wide

    Modulation

    BW

    Instrument

    cost

    New

    challenges

    Evolving

    Standards

    Challenging

    EVM

    Requirements

    Calibration

    and

    Accurate

    Power

  • 9

    C H A L L E N G E S M E T - M O R E T H A N J U S T A M P L I F I E R S

    PNA-X

    VSG

    • New target DUTs: Mixer and frequency converters (with embedded-LO) for A&D and 5G

    • Same features/advantages as amplifier measurements

    • Satisfies increasing demand for testing converters with wideband, modulated-carrier signals

    DUTRequired

    applications

    Amplifier S93070xB

    Frequency converterS93070xB +

    S93083B

    Frequency converter

    with embedded-LO

    S93070xB +

    S93083B

    + S93084B

  • 10

    • See the new capabilities in the demo video.

    • Frequency Converter Group Delay Measurement

    • Frequency Converter Two-Tone IMD Measurement

    • Phase Noise Comparison with MXG Signal Generator

    • Comparison with Current PNA-X Source

    https://www.youtube.com/watch?v=kMvyOZhMLfc&t=3shttps://www.youtube.com/watch?v=kMvyOZhMLfc&t=153shttps://www.youtube.com/watch?v=kMvyOZhMLfc&t=389shttps://www.youtube.com/watch?v=kMvyOZhMLfc&t=448s

  • 11

    All PNA/PNA-X base models will have the new source.

    • N5221B/22B/41B/42B/49B-UNY Enhanced low phase noise (export-controlled)

    • N5224B/25B/27B/44B/45B/47B-UNY Enhanced low phase noise (export-controlled)

    • N5249B-XSB 3rd RF source up to 8.5 GHz

    • N5241B/2B/4B/5B/7B-XSB 3rd RF source up to 13.5 GHz

    Note: Option XSB is available only with N524xB PNA-X option 422 or 423

    • Upgrade kits are available for the current PNA/PNA-X.

  • 12

    • Signal source upgrade for the current PNA/PNA-X B models

    • N52xxBU-2S7 for all single-source 2-port PNA/PNA-Xs:

    $13,900 + 1.5 hours installation labor at service center [total about $15k]

    • N52xxBU-4S7 for all 4-port PNA/PNA-Xs and dual-source 2-port PNA-X:

    $21,900 + 1.5 hours installation labor at service center [total about $23k]

    • Upgrade work: It can be done at the local service center

    • When you upgrade PNA/PNA-X A models, you also need to upgrade the unit

    to the B model. http://na.support.keysight.com/pna/b-upgrade.html (N8989A-SR6 synthesizers are not needed even in the case that those are needed, because the new signal

    sources will be added with this source upgrade.)

    http://na.support.keysight.com/pna/b-upgrade.html

  • 13

    • For PNA/PNA-Xs that are already equipped with the new source

    • N524xBU-XSB: option XSB retrofit

    • N52xxBU-UNY: option UNY retrofit

    • 2-port to 4-port upgrade

    • N522xBU-660 (option 200 to 400 upgrade)

    • N52xxBU-661 (option 201 to 401 upgrade)

    • N522xBU-665 (option 205 to 405 upgrade)

    • N52xxBU-677 (option 217 to 417 upgrade)

    • N52xxBU-679 (option 219 to 419 upgrade)

    • N522xBU-680 (option 220 to 420 upgrade)

    • N524xBU-284 (option 217 to 222 or 219 to 224 upgrade)