Who are we?. CodeDataPlate.com is the trade name of Rearick & Company, Inc. – Elevator Consulting CodeDataPlate.com was formed 10 years ago to provide accurate on-site code information to inspectors when performing inspections. Started with just Code Data Plates (still 50% of our business) - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Who are we?

4/17/2010 www.CodeDataPlate.com 1

NAESA EASTERN REGIONAL WORKSHOP

A17 Code Required Data Plates, Tags and Signs

what’s new and what’s not in A17.1-2007, a-2008 & b-2009

by: John S. Rearick CodeDataPlate.com

Page 2: Who are we?

4/17/2010 www.CodeDataPlate.com 2

Who are we?• CodeDataPlate.com is the trade name of Rearick &

Company, Inc. – Elevator Consulting• CodeDataPlate.com was formed 10 years ago to provide

accurate on-site code information to inspectors when performing inspections.

• Started with just Code Data Plates (still 50% of our business)

• Grown to include – Crosshead Data Plates– Inspection Tags– Other code specific Data Plates, Tags & Signs– Maintenance Control Program assistance & format

• Primary customer: Elevator Contractors

Page 3: Who are we?

4/17/2010 www.CodeDataPlate.com 3

Working Committee Involvement• Existing Installations

– Section 8.7 - Alterations– A17.3 Code for Existing Installations

• Maintenance, Repair & Replacement– Section 8.6

– MCP Task Group

• Inspections– Sections 8.10, 8.11 and Testing parts of 8.6– A17.2 Guide for Inspectors

• Wind Tower Project Team– Hoistway sub-committee

Page 4: Who are we?

4/17/2010 www.CodeDataPlate.com 4

Code Making Process• Inquiry

– Format: Edition and Requirement Number– Assigned to Working Committee to answer– Technical Revision (TN) Developed if needed

• Review and approved by Standards Comm.• Interpretation published• Approved TN’s go Public Review Draft• Finally are published in next Code Edition

Page 5: Who are we?

4/17/2010 www.CodeDataPlate.com 5

Changes in Section 8.7

A17.1-2007 EditionAddenda a-2008 & b-2009

Page 6: Who are we?

4/17/2010 www.CodeDataPlate.com 6

Alteration Plate

#REF!

codedataplate.com

ALTERATION CODE: ASME A17.1-2000SECT. 8.7 REQUIREMENTS COMPLIED WITH:

8.7.2.11.5, 8.7.2.13, 8.7.3.8, 8.7.3.12, 8.7.3.23.7, 8.7.3.24, 8.7.3.29, 8.7.3.30, 8.7.3.31.1, 8.7.3.31.2, 8.7.3.31.5, 8.7.3.31.8

CODE DATA PLATEINSTALLATION CODE: ASA A17.1-1965

Door Operator

Wiring

Re-opening Devise

Door Restrictor

Plunger Gripper

Valve

Tank

Limits

Top of Car Insp..

Leveling

Controller Replacement

Emergency Operations

Page 7: Who are we?

4/17/2010 www.CodeDataPlate.com 7

8.7 Summary of changes in 2007

8.7.1.7 Second sentence added8.7.1.8 Second sentence added8.7.2.1.3 Editorially revised8.7.2.1.4 Editorially revised8.7.2.7.6 Editorially revised8.7.2.7.7 Editorially revised8.7.2.15.2 Revised in its entirety8.7.2.17 Title editorially revised8.7.2.17.1 Title and paragraphs editorially revised8.7.2.17.2(b)(5) Editorially revised8.7.2.23 Revised in its entirety8.7.2.25.1(a) Editorially revised8.7.2.25.2(a) Editorially revised8.7.2.25.2(b) Editorially revised8.7.2.27.6 First paragraph revised8.7.2.27.8 Added

Page 8: Who are we?

4/17/2010 www.CodeDataPlate.com 8

8.7 Summary of changes in 2007

8.7.3.15.3 Editorially revised8.7.3.19 Editorially revised8.7.3.22 Title editorially revised8.7.3.22.1 First paragraph and subparagraphs

(b), (c), and (e) editorially revised8.7.3.23.1 Revised8.7.3.23.2 Revised8.7.3.23.3 Revised8.7.3.31.11 Added8.7.4.3.7 Title and paragraphs editorially revised8.7.6.1.1 Revised in its entirety8.7.6.1.5 Revised in its entirety8.7.6.1.9 Third paragraph deleted8.7.6.2.1 Revised8.9.2 Revisedand in 8.9

Page 9: Who are we?

4/17/2010 www.CodeDataPlate.com 9

8.7 Summary of changes in a-2008

8.7.2.14.2(i) Added8.7.2.27.3 First paragraph revised8.7.2.27.4 (1) Subparagraph (a) revised (2) Subparagraph (c) added8.7.2.28 Revised in its entirety8.7.3.31.4 First paragraph revised8.7.3.31.5(a) Revised8.7.3.31.5(c) Added8.7.3.31.8(c) Revised8.7.5.3 Revised in its entirety8.7.5.4 Revised in its entirety

Page 10: Who are we?

4/17/2010 www.CodeDataPlate.com 10

8.7 Summary of changes in b-2009

and in 8.9

Page 11: Who are we?

4/17/2010 www.CodeDataPlate.com 11

Alteration Changes in A17.1-2007, a-08 & b-09 except control

• 8.7.1.7 Adds Canadian (NBCC) Exceptions• 8.7.1.8 Adds Canadian (NBCC) Exceptions• 8.7.2.1.3Editorial correction• 8.7.2.1.4Editorial correction• 8.7.2.7.1Now includes both machine & control spaces• 8.7.2.7.6 Editorial correction• 8.7.2.7.7 Editorial correction• 8.7.2.10.1 Now includes 2.29.2 (4” number inside door)• 8.7.2.14.2(i) Adds requirements for car door or gate• 8.7.2.15.2 Revised Buffer requirements• 8.7.2.17 Editorial correction• 8.7.2.23 Revised Buffer requirements• 8.7.2.25 Editorial correction

(a)(b)

(b)

Page 12: Who are we?

4/17/2010 www.CodeDataPlate.com 12

Alteration Changes in A17.1-2007, a-08 & b-09 except control

• 8.7.3.15.3 Editorial correction• 8.7.3.19 Editorial correction• 8.7.3.15 Editorial correction• 8.7.3.19 Editorial correction• 8.7.3.22 Editorial correction• 8.7.3.23 Jacks are now stand alone alteration – see slide• 8.7.4.3.7 Editorial correction (travel to rise in about 50 places)• 8.7.5.3 Added Private Residence Requirements• 8.7.5.4 Added Private Residence Requirements

Reason: Many private residences have been converted to convention centers, banquet facilities, museums, etc.; where the elevators are used by the general public or as a Limited-Use/Limited-Application elevator. In these cases, the more stringent safety requirements of ASME A17.1 need to be applied.

• 8.7.6.1 Escalator alteration updated• 8.7.6.2 Moving Walk alteration upgraded

(a)(a)

Page 13: Who are we?

4/17/2010 www.CodeDataPlate.com 13

Note: These 3 requirements are often mixed up.

TN 03-1712Revise A17.1 requirements 8.7.3.23.1, 8.7.3.23.2 and 8.7.3.23.3 as follows:

8.7.3.23.1 Hydraulic Jack. Where the alteration involves the installation of a hydraulic jack, it is installed,altered or replaced it shall conform to 3.18.

8.7.3.23.2 Plungers. Where a new plunger is installed as part of an alteration or an existing plunger isaltered, it shall conform to 3.18.1.2 and 3.18.2.

8.7.3.23.3 Cylinders. Where a cylinder is installed, replaced as part of an alteration, altered, or sleeved, itshall conform to 3.18.3. If the plunger is not equipped with a stop ring conforming to 3.18.4.1, theinstallation shall also conform to 3.18.1.2 and 3.18.2.

Reason:Requirement 8.6.3.10 identifies replacement of jacks, plungers, and cylinders as an alteration and referredto 8.7.3.23. This proposed change clarifies the need to comply with existing requirements even though thereplacement is not “part of an alteration”. (See new proposed definition in TN 02-3899 for “Alteration aspart of – A repair and/or replacement that is included with other work that is classified as an alteration”)

Page 14: Who are we?

4/17/2010 www.CodeDataPlate.com 14

Alteration Changes in A17.1-2007, a-08 & b-09 for control

• 8.7.2.27.8 and 8.7.3.31.11 AddedElectrical Protective Devices. Where there is an alteration to or addition of an electrical protective device, it shall conform to 2.26.2 for that device.

• 8.7.2.27.3 POWER• 8.7.2.27.4 CONTROL REPLACEMENT• 8.7.2.27.5 MOTION• 8.7.2.27.6 OPERATION• 8.7.3.31.4 POWER• 8.7.3.31.5 CONTROL REPLACEMENT• 8.7.3.31.6 MOTION• 8.7.3.31.7 OPERATION

Control changes have been made to all 3 editionsand more are coming!

Hydro

Traction

Page 15: Who are we?

4/17/2010 www.CodeDataPlate.com 15

Note: These 4 requirements are often mixed up.

Control Changes

• Power – Supply to controller is altered in type, phase or voltage (not a new Main Line)

• Controller is replaced w/o change to Motion or Operation – could be a relay to microprocessor

• Type of Motion - such as MG to SSD or VVVF

• Type of Operation – Car Switch to Automatic

Page 16: Who are we?

4/17/2010 www.CodeDataPlate.com 16

Note: Hydro control change may not require change to fire service.

Control Changes

• 8.7.2.28 Emergency Operations• 8.7.3.31.8 Emergency OperationsRationale: To clarify the requirements when installing firefighters’ emergency

operation on existing controllers.

(a)

(a)

Page 17: Who are we?

4/17/2010 www.CodeDataPlate.com 17

Work in Progress A17.1-201X

Page 18: Who are we?

4/17/2010 www.CodeDataPlate.com 18

Work in Progress A17.1-201X

Page 19: Who are we?

SECTION 8.9 CODE DATA PLATE (a-2005)Requirement 8.9 contains requirements for all newand existing equipment within the Scope of this Code.8.9.1 Required InformationData plate shall be provided and maintained that shallindicate the Code to be used for inspections and tests(see 8.10.1.2). The data plate shall indicate the Code andedition in effect at the time of installation. The data plateshall also indicate the Code in effect at the time of anyalteration and indicate the applicable requirements of 8.7.8.9.2 LocationThe data plate shall be in plain view, securely attachedto the main line disconnect or on the controller.8.9.3 Material and ConstructionThe data plate shall be of such material and constructionthat the letters and figures stamped, etched, cast,or otherwise applied to the face shall remain permanentlyand readily legible. The height of the letters andfigures shall be not less than 3.2 mm (0.125 in.).

Page 20: Who are we?

20

SECTION 8.9 CODE DATA PLATE (2007, a-08 & b-09)Requirement 8.9 contains requirements for all newand existing equipment within the Scope of this Code.8.9.1 Required InformationData plate shall be provided and maintained that shallindicate the Code to be used for inspections and tests(see 8.10.1.2). The data plate shall indicate the Code andedition in effect at the time of installation. The data plateshall also indicate the Code in effect at the time of anyalteration and indicate the applicable requirements of 8.7.8.9.2 LocationThe data plate shall be in plain view, securely attachedto the main line disconnect or on the controller. It shallalso be permitted to locate the data plate in the controlleras long as it is in plain view with the controller door open. An additional data plate shall be installed in thevicinity of the starting switch on the exterior of escalatorsand moving walks 8.9.3 Material and ConstructionThe data plate shall be of such material and constructionthat the letters and figures stamped, etched, cast,or otherwise applied to the face shall remain permanentlyand readily legible. The height of the letters andfigures shall be not less than 3.2 mm (0.125 in.).

(07)

(b)

Page 21: Who are we?

4/17/2010 www.CodeDataPlate.com 21

Section 8.62007 vs. a-2008 & b-2008

Errors to be aware of in case an errata isn’t published

Page 22: Who are we?

4/17/2010 www.CodeDataPlate.com 22Inquiry on a-08: Does 8.6.12 apply now to all equipment not just Canada?

a-2008 b-2009SECTION 8.6MAINTENANCE, REPAIR, REPLACEMENT,AND TESTING

SECTION 8.6MAINTENANCE, REPAIR, REPLACEMENT,AND TESTING

Requirement 8.6 applies to maintenance, repairs,replacements, and testing. _________________________________________________________________________________________________________NOTES:(1) See 8.7 for alteration requirements.(2) See General in Preface for assignment of responsibilities.

Requirement 8.6 applies to maintenance, repairs,replacements, and testing.NOTES:(1) See 8.7 for alteration requirements.(2) See “General” in Preface for assignment of responsibilities.

These is no 8.6.12 in b-2009

Page 23: Who are we?

4/17/2010 www.CodeDataPlate.com 23

8.6.12 Maintenance of Elevators, Dumbwaiters,Escalators, and Moving Walks8.6.12.1 Scope8.6.12.1.1 Requirement 8.6.12 applies to allexisting installations and all new installations that havebeen placed in service. It provides the minimum standardsfor these installations. However, it is not the intentof this Section to require the alteration or replacement ofequipment to meet design, nameplate, and performancestandards not required by an earlier edition of this Codethat was in force at the time the equipment was installed.8.6.12.1.2 Requirement 8.6.12 applies also to themaintenance of other devices, analogous in design andusage, that are covered by this Code, such as material lifts.

ASME A17.1a-2008/CSA B44a-08

Canadian - NBCC

Page 24: Who are we?

4/17/2010 www.CodeDataPlate.com 24

ASME A17.1a-2008/CSA B44a-08

Page 25: Who are we?

4/17/2010 www.CodeDataPlate.com 25

ASME A17.1a-2008/CSA B44a-08

Page 26: Who are we?

4/17/2010 www.CodeDataPlate.com 26

ASME A17.1a-2008/CSA B44a-08

Page 27: Who are we?

4/17/2010 www.CodeDataPlate.com 27

ASME A17.1a-2008/CSA B44a-08

NOTES:(1) See 8.7 for alteration requirements.(2) See “General” in Preface for assignment ofresponsibilities.”Please note that TN 02-4174, which has been approved by theA17 Standards Committee for the 2009 edition, subsequentlydeletes the second and third sentences and 8.6.12.

Page 28: Who are we?

4/17/2010 www.CodeDataPlate.com 28

Products

codedataplate.com

INSTALLATION CODE: ASME A17.1a-1997CODE DATA PLATE

SECT. 8.7 REQUIREMENTS COMPLIED WITH:

CODE DATA PLATEINSTALLATION CODE: ANSI A17.1-1971ALTERATION CODE: ASME A17.1-2000

8.7.2.1.5, 8.7.2.8, 8.7.2.11.5, 8.7.2.12, 8.7.2.13, 8.7.2.14.3, 8.7.2.19, 8.7.2.20, 8.7.2.25.1(b), 8.7.2.27.1, 8.7.2.27.2, 8.7.2.27.5, 8.7.2.28

codedataplate.com

#REF!PART XII RULES COMPLIED WITH:

codedataplate.com

1201.11, 1202.13.

ALTERATION CODE: ASME A17.1a-1994INSTALLATION CODE: ANSI A17.1-1978

CODE DATA PLATE

#REF!1200.5d, 1201.3, 1201.10b, 1201.11a, 1201.12, 1202.3c, 1202.4a, 1202.5a, 1202.11, 1202.12a, 1202.12b, 1202.12e, 1202.13

codedataplate.com

1P30777

PART XII RULES COMPLIED WITH:

CODE DATA PLATEINSTALLATION CODE: NYC BC 1938 - Article 14ALTERATION CODE: ASME/ANSI A17.1b-1989

● ●

NORMALREDUCED

DOOR OPERATOR DATA PLATESecondsSeconds

cdp ●

Page 29: Who are we?

4/17/2010 www.CodeDataPlate.com 29

Page 30: Who are we?

4/17/2010 www.CodeDataPlate.com 30

Inquiry: Are Escalators no longer required to be tagged?

Approved TN 02-3392 is what is shown in 2007 - 8.11.1.6 where did the language in a-2008 and b-2009 come from?

a-2008 b-20098.6.1.7.2 ________ A test _____ tag with the test date, the_________ requirement _ number requiring the test, and thename of the person or firm performing the test shall beinstalled inthe machine room _______ for all Category 1 and 5 tests forelectric elevators and Category 1, 3, and 5 tests forhydraulic elevators._________

8.6.1.7.2 ________ A test _____ tag with the test date, the_________ requirement _ number requiring the test, and thename of the person or firm performing the test shall beinstalled inthe machine room _______ for all Category 1 and 5 tests forelectric elevators and Category 1, 3, and 5 tests forhydraulic elevators._________

?

Page 31: Who are we?

4/17/2010 www.CodeDataPlate.com 31

Page 32: Who are we?

32

Escalators & Moving Walk – Periodic Test REQ. TagPerson or Firm Performing Test:

Test Category: 1 REQ. #<2007 || a-2008> Test Item Test

Date8.11.4.2.1 ||8.6.8.15 Machine Space Access8.11.4.2.2 ||8.6.8.15.2 Machine Space Stop Switch8.11.3.2.3 ||8.6.8.15.3 Controller and Wiring8.11.4.2.4 ||8.6.8.15.4 Drive Machine & Brake Torque Test8.11.4.2.5 ||8.6.8.15.5 Speed Governor8.11.4.2.6 ||8.6.8.15.6 Broken Drive Chain Device8.11.4.2.7 ||8.6.8.15.7 Reversal Stop Device8.11.4.2.8 ||8.6.8.15.8 Broken Step-Chain/Treadway Device8.11.4.2.9 ||8.6.8.15.9 Escalator Step Upthrust Device8.11.4.2.10 ||8.6.8.15.10 Missing Step/Pallet Device8.11.4.2.11 ||8.6.8.15.11 Step/Pallet Level Device8.11.4.2.12 ||8.6.8.15.12 Step/Pallets, Chain and Trusses8.11.4.2.13 ||8.6.8.15.13 Handrail Safety System Entry Device

and Speed Monitoring8.11.4.2.14 ||8.6.8.15.14 Heaters Outdoor Units8.11.4.2.15 ||8.6.8.15.15 Permissible Stretch of Esc. Step Chain8.11.4.2.16 ||8.6.8.15.16 Disconnected Motor Device8.11.4.2.17 ||8.6.8.15.17 Response to Smoke Detectors8.11.4.2.18 ||8.6.8.15.18 Comb/Step/Pallet Impact Device8.11.4.2.19 ||8.6.8.15.19 Esc. Step/Skirt Performance Index8.11.4.2.20 ||8.6.8.15.20 Esc. Clearance Between Step and

Skirt (Loaded Gap)8.11.4.2.21 ||8.6.8.15.21 Inspection Controls8.11.4.2.22 ||8.6.8.15.22 Esc. Step Lateral Displace Device

Page 33: Who are we?

4/17/2010 www.CodeDataPlate.com 33

Approved TN 02-3392 moved all test tagging requirements to 8.11.1.6 as it appears in A17.1-2007 - but

Page 34: Who are we?

4/17/2010 www.CodeDataPlate.com 34

Inquiry: Did the Releasing Carrier Tag come back in a-2008?

Page 35: Who are we?

4/17/2010 www.CodeDataPlate.com 35

Page 36: Who are we?

4/17/2010 www.CodeDataPlate.com 36

Page 37: Who are we?

4/17/2010 www.CodeDataPlate.com 37

Approved TN 02-3392 moved all test tagging requirements to 8.11.1.6 as it appears in A17.1-2007 - but

Page 38: Who are we?

4/17/2010 www.CodeDataPlate.com 38

Inquiry: Did the Buffer Test Tag come back in a-2008?

Page 39: Who are we?

4/17/2010 www.CodeDataPlate.com 39

Page 40: Who are we?

4/17/2010 www.CodeDataPlate.com 40

Approved TN 02-3392 changed several additional items (in a, b, f and h) to be tested in A17.1-2007 - but

Page 41: Who are we?

4/17/2010 www.CodeDataPlate.com 41

Inquiry: Are test of Overspeed Switch and checking for the seal no longer required in a-2008? Ref. 8.6.4.20.5 should be 8.6.4.19.5 and all 8.6.4.18 references should be 8.6.4.19!

Page 42: Who are we?

4/17/2010 www.CodeDataPlate.com 42

Page 43: Who are we?

4/17/2010 www.CodeDataPlate.com 43

Hydraulic Elevator - Periodic Test REQ. TagPerson or Firm Performing Test:

Schindler Elevator CorporationTest Category: 1

REQ. # Test Item Test Date8.11.3.2.1 Relief Valve & System

Pressure8.11.3.2.2 Cylinder & Pressure Piping8.11.3.2.3(a) Normal Terminal Stopping

Device8.11.3.2.3(b) Governors8.11.3.2.3(c) Safeties8.11.3.2.3(d) Oil Buffers8.11.3.2.3(e) Emergency Operation FFS8.11.3.2.3(f) Standby Power Operation8.11.3.2.3(g) Power Operation of Doors8.11.3.2.3(h) Terminal Speed Reducing8.11.3.2.3(i) Low Oil & RPR Protection8.11.3.2.4 Flexible Hose & Fitting8.11.3.2.5 Pressure Switch

cdp

Page 44: Who are we?

4/17/2010 www.CodeDataPlate.com 44

Approved TN 02-3392 required only in Canada a tag to be placed on the governor after the test in A17.1-2007 - but

Page 45: Who are we?

4/17/2010 www.CodeDataPlate.com 45

Inquiry: Is the Governor Test Tag no longer required in a-2008 for jurisdictions enforcing NBCC?

Page 46: Who are we?

4/17/2010 www.CodeDataPlate.com 46

Page 47: Who are we?

4/17/2010 www.CodeDataPlate.com 47

Disclaimer

The opinions and recommendations presented here are strictly my own and are not those of ASME, NAESAI

or any organization of which I may be a member.

JSRearick

Page 48: Who are we?

4/17/2010 www.CodeDataPlate.com 48

Section 8.62007 vs. a-2008 & b-2008

Recommendation:Mark-up errors in 8.6 and

Don’t replace the pages in 8.11until an errata is published

(most errors were in moving of tests to 8.6)

Page 49: Who are we?

4/17/2010 www.CodeDataPlate.com 49

Challenges Facing InspectorsNew in 2000 and later editions

• NYC is about ½ the US Elevator population• Used A17 code as Modified by RS-18 for 30+ years• Now under A17.1-2000 with a-’02 & b-’03

– New numbering system– Harmonization with B-44

• Now has added Private Inspectors• Hefty fines for non-compliance• Lots of mis-information about:

– Adopted Codes & Effective Dates– Code Data Plate Requirements– Required Signage– Inspection Tags

Page 50: Who are we?

4/17/2010 www.CodeDataPlate.com 50

Challenges Facing InspectorsNew in 2000 and later editions

• The Inspection Community is stepping up• Industry Groups are pitching in

– NAESA is holding QEI classes– ECNY is having Code Seminars

• A17.1-1996/A17.1-2000 cross-reference tool

• CodeDataPlate.com solutions:– Code Research – Department of Buildings Liaison– Standard & Custom Code Data Plates– Replacement Plates & Required Signage– Code Data Plate Kits & Inspection Tags– MCP assistance and format consulting

Page 51: Who are we?

4/17/2010 www.CodeDataPlate.com 51

1996-2000 Cross Reference

Page 52: Who are we?

4/17/2010 www.CodeDataPlate.com 52

What Code to use for Inspections? • DC 1971 or b-1998 or ?• MD 1971 or 2007• NYC NYC BC 1915 or a-1997 or b-2003• PA PA34/7 or a-2002• GA A17.3-2008 or A17.1b-2008• VA 1965 or a-2005• NJ 1971 or a-2005• FL a-1967 or a-2005

Page 53: Who are we?

4/17/2010 www.CodeDataPlate.com 53

Page 54: Who are we?

Edition/Amendment Effective Dates (MD)CodeEdition Type StartDate EndDate

ASME A17.1-2007 1 November 16, 2009ASME A17.1a-2005 1 April 7, 2008 November 15, 2009ASME A17.1b-2003 1 March 14, 2005 April 6, 2008ASME A17.1a-2002 1 September 29, 2003 March 13, 2005ASME A17.1-2000 1 April 28, 2003 September 28, 2003ASME A17.1b-1998 1 August 23, 1999 April 27, 2003ASME A17.1a-1997 1 December 28, 1998 August 22, 1999ASME A17.1-1996 1 April 6, 1998 December 27, 1998ASME A17.1a-1994 1 August 28, 1995 April 5, 1998ASME A17.1-1993 1 July 18, 1994 August 27, 1995ASME A17.1b-1992 1 July 5, 1993 July 17, 1994ASME A17.1a-1991 1 August 29, 1992 July 4, 1993ASME A17.1-1990 1 October 14, 1991 August 28, 1992

ASME/ANSI A17.1b-1989 1 May 31, 1990 October 13, 1991ASME/ANSI A17.1a-1988 1 May 16, 1989 May 30, 1990ASME/ANSI A17.1-1987 1 July 16, 1988 May 15, 1989ANSI/ASME A17.1e-1987 1 October 29, 1987 July 15, 1988ANSI/ASME A17.1d-1986 1 May 30, 1987 October 28, 1987ANSI/ASME A17.1c-1986 1 February 26, 1987 May 29, 1987ANSI/ASME A17.1b-1985 1 February 26, 1987 February 25, 1987ANSI/ASME A17.1a-1985 1 February 26, 1987 February 25, 1987ANSI/ASME A17.1-1984 1 January 26, 1987 February 25, 1987ANSI/ASME A17.1b-1983 1 December 17, 1984 January 25, 1987ANSI/ASME A17.1a-1982 1 November 1, 1983 December 16, 1984ANSI/ASME A17.1-1981 1 September 1, 1982 October 31, 1983

ANSI A17.1b-1980 1 August 15, 1980 August 31, 1982ANSI A17.1a-1979 1 February 1, 1980 August 14, 1980ANSI A17.1-1978 1 July 13, 1979 January 31, 1980ANSI A17.1f-1975 1 November 30, 1976 July 12, 1979ANSI A17.1e-1975 1 October 31, 1975 November 29, 1976ANSI A17.1d-1975 1 October 31, 1975 October 30, 1975ANSI A17.1c-1974 1 October 31, 1975 October 30, 1975ANSI A17.1b-1973 1 September 15, 1974 October 30, 1975ANSI A17.1-1971 1 July 1, 1955 September 14, 1974

Page 55: Who are we?

4/17/2010 55

New York City

Edition/Amendment Effective DatesCodeEdition Type StartDate EndDate

ASME A17.1b-2003 2 July 1, 2009ASME A17.1a-1997 2 April 17, 2003 June 30, 2009

ASME/ANSI A17.1b-1989 2 January 1, 1991 April 16, 2003ANSI/ASME A17.1a-1985 2 January 1, 1987 December 31, 1990ANSI/ASME A17.1a-1982 2 January 1, 1985 December 31, 1986

ANSI A17.1b-1980 2 January 1, 1981 December 31, 1984ANSI A17.1-1978 2 January 1, 1979 December 31, 1980

USAS A17.1a-1967 2 January 1, 1970 December 31, 1978ASA A17.1-1965 2 January 1, 1968 December 31, 1969

NYC BC 1938 - Article 14 2 January 1, 1938 December 31, 1967NYC BC 1931 - Article 27 2 January 1, 1931 December 31, 1937NYC BC 1922 - Article 27 2 January 1, 1922 December 31, 1930NYC BC 1915 - Article 27 2 January 1, 1915 December 31, 1921

NYC RS-18 - Article 2 2 December 31, 1914

Page 56: Who are we?

4/17/2010 www.CodeDataPlate.com 56

When is Code Effective?• Date of Contract?• Date of Permit?• Date of Inspection?

If Alteration, What Rules Apply?• Only work done by Elevator Contractor now?• All alterations since installation?• Only alterations now part of the installation?

Page 57: Who are we?

4/17/2010 www.CodeDataPlate.com 57

Page 58: Who are we?

4/17/2010 www.CodeDataPlate.com 58

8.7.1 General RequirementsTRACTION HYDRO

8.7.2 8.7.38.7.2.1 Hoistway 8.7.3.18.7.2.2 Pits 8.7.3.28.7.2.7 Machine room 8.7.3.78.7.2.8 Wiring 8.7.3.88.7.2.10 Entrances 8.7.3.10

8.7.2.10.1 General <<<<8.7.2.10.2 Horizontal Slide <<<<8.7.2.10.3 Vertical Slide <<<<8.7.2.10.4 Swing Type <<<<

8.7.2.11 Hoistway Door 8.7.3.118.7.2.11.1 Interlocks <<<<8.7.2.11.4 Access Sw. (App. R) <<<<8.7.2.11.5 Door Restrictor <<<<

8.7.2.12 Operators 8.7.3.128.7.2.13 Re-opening Device <<<<8.7.2.14 Cabs 8.7.3.13

8.7.2.14.1 New Cab <<<<8.7.2.14.2 Cab Alt. Except panels <<<<8.7.2.14.3 Cab Alt. Interiors only <<<<8.7.2.14.5

8.7.2.15 Frame, Plat. & Guides 8.7.3.148.7.2.16 Load and Class

8.7.2.16.1 Type of Service 8.7.3.178.7.2.16.2 Class of Loading 8.7.3.188.7.2.16.3 Pass on Freight 8.7.3.198.7.2.16.4 Increase Rated Load 8.7.3.20

8.7.2.17 Travel or Speed 8.7.3.228.7.2.18 Safeties 8.7.3.15

Code Data Plate (8.6.1.5) Alteration Pocket Guide

For complete list see A17.1 Sect. 8.7 & App. L

Remove Stop Switch (before b-2003)

TRACTION HYDRO8.7.2.19 Governor 8.7.3.168.7.2.20 Rope Brake, etc.

Hydraulic Jack 8.7.3.23.1Hydraulic Cylinder only 8.7.3.23.3Move Power Unit 8.7.3.23.6Plunger Gripper 8.7.3.23.7Valve & Piping 8.7.3.24

8.7.2.21 Ropes 8.7.3.258.7.2.22 Counterweights 8.7.3.26

8.7.2.22.3 Cwt. Guides <<<<8.7.2.23 Buffers 8.7.3.278.7.2.24 Rails 8.7.3.28

Tank 8.7.3.298.7.2.25 Machines8.7.2.26 Terminal Stopping 8.7.3.308.7.2.27 Control Equipment 8.7.3.31

8.7.2.27.1 Top of Car 8.7.3.31.18.7.2.27.2 Leveling 8.7.3.31.2

Anti-Creep 8.7.3.31.38.7.2.27.3 Power Supply 8.7.3.31.48.7.2.27.4 Controller 8.7.3.31.58.7.2.27.5 Type of Motion 8.7.3.31.68.7.2.27.6 Type of Operation 8.7.3.31.7

Emergency Lowering 8.7.3.31.98.7.2.27.7 Remove Stop Switch* 8.7.3.31.10

8.7.2.28 Emerg. Operations 8.7.3.31.88.7.4 Other Driving Machines8.7.5 Special Applications8.7.6 Escalators & MW8.7.7 Dumbwaiters & ML

CodeDataPlate.com281/257-0516

*A17.1b-2003 and later editions only

Page 59: Who are we?

4/17/2010 www.CodeDataPlate.com 59

Courtesy of Don Rosenberger

Page 60: Who are we?

4/17/2010 www.CodeDataPlate.com 60

Typical Data Plate Violations• A17.1-2000 and later editions Part 8

• A17.3-1996 and later editions

8.6.1.6.7 Signs and Data Plates. Required signsand data plates that are damaged or missing shall berepaired or replaced.8.6.1.5 Code Data Plate8.6.1.5.1 A data plate that indicates the Codeand edition in effect at the time of installation and anyalteration (see 8.7.1.8) shall be provided. The data plateshall also specify the Code and edition in effect at thetime of any alteration and the applicable requirementsof 8.7.8.6.1.5.2 The Code data plate shall complywith 8.9.

3.5.6 Rail Lubricants and Lubrication Plate…A metal plate shall be securely attached to the car crosshead…

Page 61: Who are we?

4/17/2010 www.CodeDataPlate.com 61

8.6.1.6.7 Check for any Missing or Damaged Signs and Data Plates

• Machine Room– Brake Plates– Governor Plate– Code Data Plate– Ambient Air Plate– Hydro Data Plates– Warning Signs

• Fire Service Signs

• Hoistway and Pit– Crosshead Data Plate– Rail Lube Instructions– Warning Signs– Safety Plank Plate– Buffer Plate– Counterweight Runby

• Freight & Capacity

Page 62: Who are we?

● ●

POUNDS F.P.M.

NUMBER OF ROPES: IN.

MANUFACTURED: BY:RAIL LUBRICATION INSTRUCTIONS:

● ●

RATED BREAKING STRENGTH: POUNDS

the safety for the characteristics of the rail lubricant to be used.

DIAMETER:

RATED SPEED: COMPLETE CAR WEIGHT:

RATED LOAD: POUNDS

CROSSHEAD DATA PLATE

codedataplate.com

INSTALLATION CODE: ASME A17.1a-1997CODE DATA PLATE

#REF!SECT. 8.7 REQUIREMENTS COMPLIED WITH:

8.7.2.11.5, 8.7.2.28.

CODE DATA PLATEINSTALLATION CODE: ANSI A17.1-1978ALTERATION CODE: ASME A17.1-2000

codedataplate.com

MAXIMUM COUNTERWEIGHT

RUNBY 24"

● ●

NORMALREDUCED

DOOR OPERATOR DATA PLATESecondsSeconds

cdp ●

● ●

● CDP ●

LOAD RATING: 6000 POUNDS

NUMBER OF SPRINGS: 2

BUFFER MARKING PLATE

STROKE: 2 1/2 INCHES

● ●

● cdp ●

DO NOT LUBRICATE

RAIL LUBRICATION INSTRUCTIONS: