Wind tunnel facilities wind engineering & architectural aerodynamics
London | Hong Kong | Kuala Lumpur | Abu Dhabi | Dubai | Shanghai | Houston
Bmt operates three large in-house wind tunnel facilities. these facilities are supported through state-of the art instrumentation and data acquisition systems to support comprehensive studies of steady and unsteady aerodynamic effects on large scale engineering structures and automotive vehicles. in particular these facilities support:
Boundary Layer Wind TunneL FaciLiTy
dedicated instrumentation
• Boundary layer wind tunnel testing
• static and dynamic section model testing
• airfoil testing
• multiple adjustable range 6-component dynamic force balance systems for unsteady high frequency force balance measurements
• 1152 channel low-range simultaneous pressure scanning system for fluctuating pressure measurements
• multi-channel non-contacting displacement transducers and accelerometers for aeroelastic response measurements
• multi-channel hot-wire and hot film anemometry systems for fluctuating wind speed and turbulence measurements
• multiple channel differential pressure probes for unsteady wind speed measurements
• Flow visualisation facilities including smoke generators
• gas concentration sensors
• digital video recording / editing facilities
technical specification
type closed circuit
operational wind speed range 0.2 m/s – 45 m/s
test section dimensions 4.8 m wide × 2.4 m high × 15 m long
turntable automated multiple plate 2.4m / 3m / 4.5 m
traversing gear automated 2 axis
Boundary Layer Wind
TunneL FaciLiTy conT
• Bluff body aerodynamic testing
• open and closed wheel race car testing
Tel: +44 20 8614 4400 Fax: +44 20 8943 3224 Email: [email protected] Website: www.bmtfm.com
race car / auTomoTive Wind TunneL FaciLiTyaeronauTicaL Wind TunneL FaciLiTy
dedicated instrumentation
• Variable range 3 and 6-component dynamic force balances for unsteady load measurements
• 1152 channel low-range simultaneous pressure scanning system for fluctuating pressure measurements
• multi-channel non-contacting displacement transducers and accelerometers for aeroelastic response measurements
• Flow visualisation facilities including smoke generators
• digital video recording / editing facilities
• dynamic spring / mass / eddy current damper rig for aeroelastic response measurements
Key Features
• Boundary layer suction operated in conjunction with a boundary layer scoop
• adaptive walls
• exhaust blow simulation
• Pc based tunnel reference condition monitoring system
• multiple video camera test section and model monitoring
dedicated instrumentation
• height and pitch adjustable model support structure (maximum ground clearance 250mm), equipped with a 6-component load cell
• solid state 64 channel Psi multi-channel simultaneous pressure scanning system
• Pc-based data acquisition systems
technical specification
type closed circuit
maximum wind speed 0.2 m/s – 48 m/s
rolling road 1.7m wide × 3.6m long / maximum operating speed 55m/s
test section dimensions 2.3 m wide × 1.8 m high × 6.0 m long
technical specification
type closed circuit
operational wind speed range 0.2 m/s – 65 m/s
test section dimensions octagonal 2.7 m wide × 2.1 m high
turntable automated 2.4m
traversing gear Various variable geometry
Tel: +44 20 8614 4400 Fax: +44 20 8943 3224 Email: [email protected] Website: www.bmtfm.com
For further information contact: Tel: +44 20 8614 4400 Fax: +44 20 8943 3224Email: [email protected] Website: www.bmtfm.com
BMT Fluid Mechanics Limited, 67 Stanton Avenue, Teddington, Middlesex, TW11 0JY, UK