wiremold ® ofr series overfloor raceway system. need existed for divided pancake primarily in...

16
Wiremold ® OFR Series Overfloor Raceway System

Upload: litzy-atchley

Post on 15-Dec-2015

215 views

Category:

Documents


1 download

TRANSCRIPT

Wiremold® OFR SeriesOverfloor Raceway System

Need existed for divided pancake Primarily in fitness centers, classrooms.

Open space areas where coming through floor or ceiling is not an option.

On grade Trenching is too expensive May not have access to floor below (different

tenant) Historical building

Introduction - Background

Conference rooms with multiple service requirements

Power, Communications and AV

New classroom configurations Pod style Feeding Smart boards

Auditoriums for podiums

Increase in Communication and AV requirements

Introduction - Background

OFRB-8 8 ft base (4 per carton) OFRBC-8 8 ft base and cover (1 per carton)OFRC-8 8 ft cover (4 per carton) OFR10A Entrance End FittingOFR48-2 2-Gang Device BoxOFR48-4 4-Gang Device BoxOFRWC Wire ClipOFR89-2400Transition from 2400 Raceway to OFROFR89-4000Transition from 4000 Raceway to OFROFR89-DS4000 Transition from DS4000 Raceway to OFROFR89-VIS Transition from Vista Point5 to OFR

Product Listing

OFR11 Flat Elbow

OFR1 Coupling

OFR09 Grounding Clip

OFR47-B Blank Device Plate

OFR47-D Duplex Plate

OFR47-R Decorator Plate

OFR47-U Extron MAAP Plate

OFR47-V Extron AAP Plate

OFR47-2A Communication Device Plate

OFR47-U2A Comb. AV/Comm Plate

OFR48-4GX 4-Gang Device Box Crossover Kit

Product Listing

Low profile Unobtrusive, ADA compliant

design.

Installs in open space areas Provides power,

communications and AV wiring to areas where in-floor and ceiling distribution is not an option.

Multi-channel base Provides space for multiple

combinations of power, communications and AV in one raceway.

System Features & Benefits

System Features & Benefits

Open system device plates for data and AV System can accommodate a wide variety of

devices and manufacturers.

Attaches directly to floor covering (works with carpet, tile, wood, etc)

No need to alter existing floor covering.

Meets ADA Accessibility Guidelines Raceway assembly is designed to meet the ADA

Accessibility Guidelines as it pertains to ADA Standard 4.5 which addresses changes in floor and ground surface levels.

Black powder coat finish Durable textured finish, blends with most

decors. Multiple transition options

Overfloor Raceway can be fed from the wall, DS4000, 4000 and 2400 Series Raceway as well as Vista Point5 Architectural Column.

Tamper resistant Cover is difficult to remove without proper

tools. cETLus listed

Will be UL listed as well. Will be stocked by electrical and

communication distributors as well as AV Integrators

Product will be readily available in all channels.

System Features & Benefits

Raceway Base and Cover

Unobtrusive, ADA compliant design.

4 channel base for multiple services.

Cover has durable black powder coat finish.

Tamper resistant hex screws for cover.

Load tested to UL requirements for floor boxes (300 lbs. across 3” diameter).

Product Features & Benefits

Device Boxes and Plates

4-gang box can accommodate power and communications on both sides with crossover kit.

Open system - power, communications and AV can go anywhere.

Side mounting of devices provides large cable bend radius inside raceway.

Product Features & Benefits

Product Features & Benefits

Transition Fittings Wall mounted dual channel raceway can

transition to any channel of OFR.

Entrance End Fitting has ½” and 1 ¼” KO Trade Size.

Raceway transitions available for 2400, 4000 and DS4000. Vista Point5 available as well.

Applications

Fitness Centers Treadmills, ellipticals, etc.

Applications

Open Space Areas Board Rooms and Conference Rooms New style classroom pods

Applications

Auditoriums Lecterns, podiums

Technical Information

cETLus listed

UL listing is pending

Meets ADA Accessibility Guidelines ADA Standard 4.5

Vertical Markets

Amusement

Office

Financial

Education

Retail Construction

Hospitality