wisconsin - milbankdesign and manufacturing, milbank’s portfolio includes metering equipment,...

76
Wisconsin Area Catalog Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Upload: others

Post on 06-Jun-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

WisconsinArea Catalog

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Page 2: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

2

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

MILBANKOVERVIEW

Milbank OverviewEnergy At Work since 1927

Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial, industrial, utility and transportation sectors. With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American manufacturer headquartered in Kansas City, Mo. For more information, please visit milbankworks.com.

As a market leader in electrical metering equipment, Milbank has set the standard for quality since 1927. Hundreds of configurations are available, including many sizes, knockout configurations, terminal configurations, bypass options, hubs, locks and connectors. Milbank has the socket you need with thousands of active products to meet your utility’s requirements.

Milbank doesn’t just build empty enclosures. We can deliver the entire package, complete with custom control equipment built to your exact specifications by our engineers. Milbank commercial pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures. Milbank’s manual and automatic transfer switches are durable, easy to install and compatible with most generators.

Milbank’s line of enclosures include commercial junction boxes, panel mount enclosures, transformer cabinets, wireway, trough and industrial panel mount and push-button enclosures. Built with high-quality craftsmanship and materials which meet or exceed industry standards, Milbank enclosures are made to protect controls and equipment from dust, dirt and other harmful elements found in a wide variety of environments.

METERING

ENCLOSED CONTROLS

ENCLOSURES

Page 3: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

3TABLE OFCONTENTS

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Table of ContentsAir Conditioner Disconnects30-60 amp AC disconnects .......................................................................................................................................... 4–5Hot tub disconnects .......................................................................................................................................................... 6

Single Position Sockets125 amps, 4 terminals, ringless ......................................................................................................................................... 7200 amps, 4 terminals, ringless ......................................................................................................................................... 8125 amps, 7 terminals, lever bypass, ringless ................................................................................................................... 9200 amps, 4, 5 & 7 terminals, lever bypass, ringless ................................................................................................ 10–12320 amps, 4, 5 & 7 terminals, lever bypass, ringless ................................................................................................ 13–14

Meter Mains100–200 amps, 4 terminals, ringless ............................................................................................................................... 15200 amps, 4 terminals, with load center, ringless ........................................................................................................... 16200 amps, cold sequence meter mains ........................................................................................................................... 17

Multi-Position100–200 amps, 4 terminals, ringless ......................................................................................................................... 18–23200 amps, 5 & 7 terminals, lever bypass, ringless .................................................................................................... 24–26125 & 200 amps, 4 terminals, meter mains, ringless ................................................................................................. 27–28

Transformer Rated Sockets20 amps, 5–13 terminals, ringless ................................................................................................................................... 29Two-position, 20 amps, 8–13 terminals, ring type .......................................................................................................... 30

Pedestals200 amps, 4 terminals, ringless ....................................................................................................................................... 31100–200 amps, 4, 5 & 7 terminals, ringless .............................................................................................................. 32–33100–200 amps, 4 terminals, meter main, ringless ........................................................................................................... 34100–200 amps, 4 terminals, meter main with load center, ringless .......................................................................... 35–37100–200 amps, 5 terminals, meter main with load center, lever bypass, ringless ..................................................... 38-39320 amps, 4 & 5 terminals, meter main with load center, lever bypass, ringless ....................................................... 40-41

MiscellaneousJoint Use Termination Cabinet ....................................................................................................................................... 42Polyphase enclosures for A base meters ........................................................................................................................ 43Type K4 & K7 meter sockets .................................................................................................................................... 44–46Lugs for K-Series ............................................................................................................................................................. 47Commercial Pedestals ................................................................................................................................................ 48-49Circuit Breakers ......................................................................................................................................................... 50-57Accessories ............................................................................................................................................................... 60–62Commerical & Industrial Enclosures ................................................................................................................................ 63Reference Information .............................................................................................................................................. 64–68Utility Approvals Chart ............................................................................................................................................. 69–71Index ......................................................................................................................................................................... 72–73

Page 4: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

4AC

DISCONNECTS

Air Conditioner Disconnects30-60 Amps | Fusible & Non-Fusible

Milbank’s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements in the NEC, and also complies with Article 440-14 in the NEC. To ensure the safest conditions, we designed our disconnect pullouts to be removable so they may be reinstalled in the off position. Another safety feature is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading finish.

Catalog Number

Amps TypeMax H.P.

Weight(lbs.)

Line/Load Wire Range Ground Wire

Range CU/ALDimensions Wire Rating

CU AL D" W" H" CU °C AL °C

U3802 60 Non-Fusible 10 3.25 #14-#2 #12-#2 #14-4 21⁄2 5 71⁄2 60°/75° 60°/75°

U3812 60 Non-Auto 10 3.25 #14-#2 #12-#2 #14-4 21⁄2 5 71⁄2 60°/75° 60°/75°

U3832 30 Fusible 3 2.5 #14-#3 #14-#3 #14-3 21⁄8 5 7 60°/75° 60°/75°

U3862 60 Fusible 10 3.3 #14-#3 #14-#3 #14-3 21⁄8 5 9 60°/75° 60°/75°

30–60 Amps | 1Ø 240 VAC | Air Conditioner Disconnects

Notes

• UL listed as Enclosed Pullout Switch• Type 3R rain-resistant• One-inch concentric knockouts

U3832U3812U3802

Page 5: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

5Air Conditioner Disconnects60 Amps | With 20 Amp GFCI Receptacle

ACDISCONNECTS

CatalogNumber

TypeMax H.P.

Weight(lbs.)

Line/Load Wire Range

Ground Wire Range

CU/AL

Dimensions Wire Rating

CU AL D" W" H" CU °C AL °C

U3822-20GWR Non-Fusible 10 6 #14-#2 #12-#2 #14-4 44⁄5 51⁄4 72⁄5 60°/75° 60°/75°

60 Amps | 1Ø, 240 VAC | Air Conditioner Disconnect with GFCI Receptacle

Notes

• Disconnect Pullouts: To ensure the safest conditions, Milbank disconnect pullouts are reversible so they may be reinstalled in the OFF position.• Padlock Provision: All units are designed with a padlock provision on the cover for security.• *In-Use Cover: Cover is rated as an in-use cover (cover may be closed with cords plugged into receptacle).

• Meets NEC #210.63 requirements• UL listed as Power Outlet• Type 3R enclosure• In-use cover*• Duplex ground connector• 1" concentric knockouts

• 1Ø, 240 volt• 60 amp, non-fused• 20 amp GFCI receptacle• Reset/test button• Weather and tamper resistant• Meets NEC #406.8 requirements

Specifications

U3822-20GWR

Page 6: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

6HOT TUB

DISCONNECTS

Hot Tub DisconnectsType 3R Enclosures

U4881-O-50GB U4881-O-60GB

Catalog Number

Breaker Amps

TypeWeight(lbs.)

Line/LoadWire Range

Ground Wire Range

CU/AL

Dimensions

CU AL D" W" H"

U4881-O — Breaker Provision 7 #14-1/0 #14-1/0 #14-1/0 33⁄4 71⁄2 81⁄2

U4881-O-50GB 50 Breaker 8 #14-1/0 #14-1/0 #14-1/0 33⁄4 71⁄2 81⁄2

U4881-O-60GB 60 Breaker 8 #14-1/0 #14-1/0 #14-1/0 33⁄4 71⁄2 81⁄2

100 Amps | Hot Tub Disconnect or Sub Panel Breaker Enclosure | Type 3R

Specifications

• 240 volt ground fault protection• UL listed, Type 3R rain-resistant• 2-pole, 50 or 60 amp GFCI breaker protection• Compact size• Three or four wire installation

• 1Ø, 120/240 VAC• Standard package of 12• Two extra one-pole breaker spaces• 100 amp overall rating• Easy to install

Page 7: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

7

1

2 2

4

33

Single Position Sockets125 Amps | 4 Terminals | Ringless | 600 VAC

Notes

• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Bypass: The horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.• Connectors: Extruded aluminum connectors are tin plated. Unit is supplied with a triplex neutral.• Fifth Terminal: For field-installed fifth terminal, order catalog number 5T8K2 (must be bolted in).

7487

CatalogNumber

Terminals Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4

U7487-RL-TG-KK 4 OH H.O. #6-2/0 #6-2/0 Horn 35⁄16 8 111⁄2 2 11⁄2 11⁄4 1⁄4

125 Amps | 4 Terminals | Ringless | Single Position

U7487-RL-TG-KK

125 AMPSINGLE

POSITIONSOCKETS

Page 8: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

8

1

1 1 1

2 3

1

200 AMPSINGLE

POSITIONSOCKETS

Single Position Sockets200 Amps | 4 Terminals | Ringless | 600 VAC

1773

Notes

• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Bypass: The horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.• Connectors: Units are supplied with extruded aluminum connectors and bonded triplex neutral.• Fifth Terminal: For field-installed fifth terminal, order catalog number K5T to fit into square opening in the 9 o’clock position.

CatalogNumber

Terminals Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4

U1773-XL-TG-KK 4 OH C.P. #6-350 #6-350 Horn 41⁄8 11 151⁄2 21⁄2 1⁄4,1⁄2 1⁄4 —

U3850-O-TG-KK 4 UG Blank #6-350 #6-350 Horn 41⁄2 13 151⁄4 3 21⁄2 11⁄2 1⁄4,1⁄2

200 Amps | 4 Terminals | Ringless | Single Position

U1773-XL-TG-KK

1 2

2

3

4

2

3850

U3850-O-TG-KK

Page 9: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

9

1 1

1

2

23

1 2

34

1 1 1

125 AMPSINGLE

POSITIONSOCKETS

Lever Bypass Single Position Sockets125 Amps | 7 Terminals | Ringless | 600 VAC

7573 9320

Notes

• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Bypass: The lever operates bypass only; it does not provide clamping action on meter spades.• Connectors: Units are supplied with extruded aluminum connectors and bonded triplex neutral.

CatalogNumber

Terminals Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4

U7573-RL 7 OH H.O. #6-2/0 #6-2/0 Lever 47⁄8 10 181⁄2 2 3⁄4 1⁄4,1⁄2 —

U9320-RXL 7 OH/UG C.P. #6-2/0 #6-2/0 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4

125 Amps | 7 Terminals | Ringless | Single Position

U7573-RL U9320-RXL

Page 10: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

10

1 2

34

1 1 1

200 AMPLEVER

BYPASSSOCKETS

Lever Bypass Single Position Sockets200 Amps | 4 & 5 Terminals | Ringless | 600 VAC

U1211-RXL U4801-XL-5T9

12114801

Notes

• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Bypass: The lever on the U1211 operates bypass only; it does not provide clamping action on meter spades. The U4801 is a heavy duty lever bypass and the lever supplies clamping action on meter spades.• Connectors: Units are supplied with extruded aluminum connectors and bonded triplex neutral.• Fifth Terminal: For field-installed fifth terminal, order catalog number K3866.• †Factory-Insalled Fifth Terminal: These units include a factory-installed fifth terminal in the 9 o’clock position for use on Alliant Energy lines when a fifth terminal is required.

CatalogNumber

Terminals Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4

U1211-RXL 4 OH C.P. #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4

U4801-XL 4 OH/UG C.P. #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4

U4801-XL-5T9 5† OH/UG C.P. #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4

200 Amps | 4 & 5 Terminals | Ringless | Lever Bypass | Single Position

Page 11: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

11

1

1

2

3

34 1 1

1

1

2

34

200 AMPLEVER

BYPASSSOCKETS

Lever Bypass Single Position Sockets200 Amps | 5 Terminals | Ringless | 600 VAC

U9550-RL U9551-O U8624-RXL

9550 95518624

Notes

• Grounded B Phase: The U9550 and U9551 have a grounded B phase that can be field-isolated.• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Bypass: The lever operates the bypass device and supplies clamping action on meter spades.• Connectors: Supplied with internal hex connectors. Extruded aluminum connectors are tin plated.

CatalogNumber

Terminals Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4

U9550-DL 5 OH 2" #6-350 #6-350 Lever 47⁄8 10 181⁄2 3 21⁄2 3⁄4 1⁄4,1⁄2

U9551-O 5 UG Blank #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4

200 Amps | 5 Terminals | Ringless | Lever Bypass | Single Position

Page 12: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

12

1

34

1 1 1

2

200 AMPLEVER BYPASS

SOCKETS

74219700

7423 97014701

U9700-RRLU7423-XLU7421-RL

Lever Bypass Single Position Sockets200 Amp | 7 Terminals | Ringless | 600 VAC

Notes

• †Service: The U7423 and U9701 are overhead only for We Energy.• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• External Hex: The U4701 has external hex bolt in the lugs. • Lever Bypass: The lever in the U7421 and U7423 operates the bypass only and does not provide clamping action on meter spades. The lever in the U9700, U9701, U4701 supplies clamping action and operates bypass device.• Isolated Neutral: For field-installed isolated neutral for U9701, U7423 and U4701, order K1047.• Connectors: Units are supplied with extruded aluminum connectors.

CatalogNumber

Terminals Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4

U7421-RL 7 OH H.O. #6-350 #6-350 Lever 47⁄8 10 181⁄2 3 21⁄2 3⁄4 1⁄4,1⁄2

U9700-RRL 7 OH H.O. #6-350 #6-350 Lever 47⁄8 10 181⁄2 3 21⁄2 3⁄4 1⁄4,1⁄2

U7423-XL 7 OH/UG† C.P. #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4

U9701-RXL 7 OH/UG† C.P. #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4

U4701-XL 7 OH/UG C.P. #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4

200 Amps | 7 Terminals | Ringless | Lever Bypass | Single Position

1

1

2

3

34

U9701-RXL U4701-XL

1 2

1 1 134

Page 13: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

13320 AMP

LEVER BYPASSSOCKETS

Lever Bypass Single Position Sockets320 Amp | 4 & 5 Terminals | Ringless | 600 VAC

4363 3000 1779

U4363-X-QG U3000-O-K3L-K2L U1779-RRL-5T9-K3

Notes

• †Factory-Installed Fifth Terminal: Includes factory installed fifth terminal in the 9-o’clock position for use on Alliant Energy lines when a fifth terminal is required.†

• ‡Amperage Rating: These units are rated 300 amp continuous when used on Alliant Energy lines.• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Lever Bypass: The lever supplies clamping action and operates bypass device.• Fifth Terminal: For field-installed fifth terminal, order catalog number K3865.• Isolated Neutral: For field-installed isolated neutral for U3000, order K5978. For the U4363, order K5986• Connectors: Studded products are supplied with 3⁄8”-16 hex head nuts with Belleville washers. For connector lug kits for

the U1779, order as extra K1539L (350 kcmil non-rotating), K1540L (600 kcmil non-rotating) or K1350L (twin 350 kcmil non-rotating). For U3000, order K1350L (350 kcmil non-rotating) or K1540L (600 kcmil non-rotating). For U4363, order K1539 (350 kcmil), K1540 (600 kcmil) or K1350 (twin 350 kcmil). Note that U4363 is UL listed based on parallel 250 conductors only.

CatalogNumber

Terminals Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4

U1779-RRL-K3‡ 4 OH H.O. #4-600 kcmil (1)1/0-250 kcmil (2)

3⁄8"x16 Studs Lever 47⁄8 13 383⁄4 3 21⁄2 1⁄4,1⁄2 1⁄4

U4363-X-QG 4 OH/UG C.P. 3⁄8"x16 Studs 3⁄8"x16 Studs Lever 47⁄8 13 281⁄4 3 1⁄4,1⁄2 1⁄4 —

U3000-O-K3L 4 UG Blank #4-600 kcmil (1)1/0-250 kcmil (2)

3⁄8"x16 Studs Lever 47⁄8 15 30 3 1⁄4,1⁄2 1⁄4 —

U3000-O-K3L-K2L‡ 4 UG Blank #4-600 kcmil (1)1/0-250 kcmil (2) (2) #6-350 Lever 47⁄8 15 30 3 1⁄4,1⁄2 1⁄4 —

U1779-RRL-5T9-K3‡ 5† OH H.O. #4-600 kcmil (1)1/0-250 kcmil (2)

3⁄8"x16 Studs Lever 47⁄8 13 383⁄4 3 21⁄2 1⁄4,1⁄2 1⁄4

U3000-O-5T9-K3L-K2L‡ 5† UG Blank #4-600 kcmil (1)1/0-250 kcmil (2) (2) #6-350 Lever 47⁄8 15 30 3 1⁄4,1⁄2 1⁄4 —

320 Amps | Ringless | Lever Bypass | Single Position

1 1

111

23

1 1

1 1 123

1 1 1

1 2

34

Page 14: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

14320 AMP

LEVER BYPASSSOCKETS

Lever Bypass Single Position Sockets320 Amps | 7 Terminals | Ringless | 600 VAC

2594 2120

U2594-X U2120-X

2

13

4

1

1

3

4

1

2

1

Catalog Number Terminals Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4

U2594-X-K7 7 OH/UG C.P. #4-600 kcmil (1)1/0-250 kcmil (2)

3⁄8"x16 Studs Lever 61⁄2 19 341⁄8 4 3 1 1⁄4

U2120-X-K7 7 UG C.P. #4-600 kcmil (1)1/0-250 kcmil (2)

3⁄8"x16 Studs Lever 61⁄2 173⁄4 313⁄4 4 3 1 1⁄4

320 Amps† | Ringless | Lever Bypass | Single Position

Notes

• †Amperage Rating: These units are rated 300 amp continuous when used on Alliant Energy lines.• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Lever Bypass: The lever supplies clamping action and operates bypass device.• Connectors: Studded products are supplied with 3⁄8”-16 hex head nuts with Belleville washers. For connector lug kits, order

as extra K3082 (350 kcmil), K3441 (600 kcmil) or K3442 (twin 350 kcmil).• Isolated Neutral: For field-installed isolated neutral, order K5977.

Page 15: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

15

1 1

12

100-200 AMPMETERMAINS

Meter Mains100–200 Amps | 4 Terminals | Ringless | 120/240 VAC

U5842-RL-200-KKU7375-RL-KK U5844-PXL-200-KK

1 2

35

3

3

4

4

4

4

2 2 2

584273755844

Catalog Number Service HubConnectors CU/AL Dimensions Knockouts

Line Load D" W" H" 1 2 3 4 5

U7375-RL-KK OH C.P. #6-2/0 CB 33⁄4 81⁄8 22 11⁄4 1⁄4,1⁄2 — — —

U5842-RL-100-KK* OH H.O. #6-350 CB - 100A 41⁄8 8 30 21⁄2 1⁄4,1⁄2 1⁄4 — —

U5842-RL-200-KK* OH H.O. #6-350 CB - 200A 41⁄8 8 30 21⁄2 1⁄4,1⁄2 1⁄4 — —

U5844-PXL-200-KK* OH/UG C.P. #6-350 CB - 200A 41⁄2 14 30 3 21⁄2 1 1⁄2,3⁄4 1⁄4,1⁄2

100-200 Amp | 4 Terminal | Meter Mains | Horn Bypass | Ringless

*AIC Rating: Models are rated 22K AIC when using Siemens QPH (100 amp) or QNH (200 amp) breakers.• Hub: -PXL versions supplied with one (1) closing plate packed inside. Order other hubs separately.• Fifth Terminal: For field installable fifth terminal kit, order K5T.• Bypass: The horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.

Notes

1 1

1 23

Page 16: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

16200 AMP

METER MAINW/ LOAD CENTER

Meter Mains with Load Center200 Amps | 4 Terminals | Ringless | 120/240 VAC

1 2

3 3 3

4 56

54

5 51685268

U5168-XTL-200-KK U5268-XTL-200-KK

Catalog Number Service HubConnectors

CU/AL – LineBranchCircuits

Dimensions Knockouts

D" W" H" 1 2 3 4 5 6

U5168-XTL-100-KK OH/UG C.P. #6-350 10 41⁄2 141⁄8 32 3 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2

U5168-XTL-200-KK OH/UG C.P. #6-350 8 41⁄2 141⁄8 32 3 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2

U5268-XTL-100-KK OH/UG C.P. #6-350 20 41⁄2 141⁄8 30 3 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2

U5268-XTL-200-KK OH/UG C.P. #6-350 20 41⁄2 141⁄8 30 3 21⁄2 2 1 1⁄4,1⁄2 1⁄4,1⁄2

200 Amps | 4 Terminals | Meter Mains with Load Center | Horn Bypass | Ringless

• AIC Rating: The U5168 and U5268 are is rated 22K AIC when using Siemens QPH (100 amp) or QNH (200 amp) breakers. • Fifth Terminal: For field installable fifth terminal kit, order K5T.• Bypass: The horn type bypass is factory installed and permits changing and testing of the meter without interrupting

customer service when used with utility-supplied jumpers.

Notes

K5815Large QN with small frame Q

K5820 Large frame QN with large frame

QN

K5830 Small frame Q to

small frame Q

Generator Interlock (compatible with U5168 and U5268)

Page 17: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

17200 AMP

COLDSEQUENCE

METER MAINS

Cold Sequence Meter Mains200 Amps | 7 Terminals | Ringless

200 Amps | Fuse Pullout Disconnects Ahead Of Meter Socket

Catalog Number Terminals Service HubConnectors CU/AL

BypassDimensions Knockouts

Line & Load D" W" H" 1 2 3 4

U5767-X-200-TF 7 OH/UG C.P. #6-350 Lever 427⁄32 13 43 3 1⁄4,1⁄2 1⁄4 —

U5767-X-200-CB 7 OH/UG C.P. #6-350 Lever 427⁄32 13 43 4 21⁄2 1 1⁄2 , 3⁄4

U5787-O-200-TF 7 UG Blank #6-350 Lever 427⁄32 26 28 4 1⁄2 , 3⁄4 1 1⁄2 , 3⁄4

U5767-O-200-CB 7 UG Blank #6-350 Lever 427⁄32 13 43 4 21⁄2 1 1⁄2 , 3⁄4

U5767-X-200-TF U5787-O-200-TF

5767

1

23 344

2 2 21 1

1 1

5787

Notes

• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.• Fuse pullouts use class T fuses.

1

1 1 123

1

Page 18: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

18100 AMPMULTI-

POSITIONSOCKETS

Multi-Position Sockets100 Amp | 4 Terminals | Ringless | 300 VAC

1223 3 3 3 3 3

2 2 2 2 2 2

2 2

123 3 3 3 3 3 3

2 2 2 2 2 2

2 2 2 2 123 3 3 3 3 3 3 32 2 2 2 2

2 222222

1

2 2 2 2

23 333 2

U8032-XL-KK

8033 80348032

8035 8036

Catalog Number Positions Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3

U8032-XL-KK 2 OH/UG† C.P. #6-350 #6-2/0 Horn 41⁄2 241⁄2 16 21⁄2 2 1⁄2

U8033-XL-KK 3 OH/UG† C.P. #6-350 #6-2/0 Horn 41⁄2 3211⁄16 16 21⁄2 2 1⁄2

U8034-XL-KK 4 OH/UG† C.P. #6-350 #6-2/0 Horn 41⁄2 407⁄8 16 21⁄2 2 1⁄2

U8035-XL-KK 5 OH/UG† C.P. #6-350 #6-2/0 Horn 41⁄2 491⁄16 16 21⁄2 2 1⁄2

U8036-XL-KK 6 OH/UG† C.P. #6-350 #6-2/0 Horn 41⁄2 571⁄4 16 21⁄2 2 1⁄2

100 Amp per Position | 4 Terminals | Multi-Position | Center Wireway | Horn Bypass | Ringless

• †Service: Overhead only for We Energy.• Fifth Terminal: For field mounted fifth terminal, order catalog number 5T8K2 for the 6-o’clock position, and K9959 for the 9 o’clock position. Only the U8032-XL-KK is Alliant approved for fifth terminal (U8032-XL-KK-5T9)• Connectors: Extruded aluminum connectors are tin plated.• Bypass: The horn bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.

Notes

1

2 2 2 2 2

22 3333 32

Page 19: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

19100 AMPMULTI-

POSITIONSOCKETS

Multi-Position Sockets100 Amps | 4 Terminals | Ringless | 300 VAC

L572-XL-KK

13333331 2 2 2 2

2 2 2 2 2

2

2 2 2 2 2 2 11 3 3

2 2 2 2 2 2

122222

2 22222

3 31

1 3 32 2 2

2 2 2 2

Catalog Number

Positions Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3

L572-XL-KK 2 OH/UG C.P. #6-350 #6-2/0 Horn 41⁄2 205⁄16 16 21⁄2 2 1⁄4,1⁄2

L573-XL-KK 3 OH/UG C.P. #6-350 #6-2/0 Horn 41⁄2 281⁄2 16 21⁄2 2 1⁄4,1⁄2

L574-XL-KK* 4 OH/UG C.P. #6-350 #6-2/0 Horn 41⁄2 4011⁄16 16 21⁄2 2 1⁄4,1⁄2

L575-XL-KK* 5 OH/UG C.P. #6-350 #6-2/0 Horn 41⁄2 487⁄8 16 21⁄2 2 1⁄4,1⁄2

L576-XL-KK* 6 OH/UG C.P. #6-350 #6-2/0 Horn 41⁄2 571⁄16 16 21⁄2 2 1⁄4,1⁄2

100 Amp per Position | 4 Terminal | Multi-Position | Horn Bypass | Side Wireway | Ringless

• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.• Fifth Terminal: For field mounted fifth terminal, order catalog number 5T8K2 for the 6-o’clock position, and K9959 for the 9 o’clock position.• Connectors: Extruded aluminum connectors are tin plated.• Bypass: The horn bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.• Alliant: Only the L572 and L573 are approved for overhead and underground applications.*Positions 4, 5 and 6: OH only for Alliant Energy.

Notes

1 2 2

2 22

3 3 L572 L573

L575

L576

L574

Page 20: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

20100 AMPMULTI-

POSITIONSOCKETS

Multi-Position Sockets100 Amps | 4 Terminals | Ringless | 300 VAC

1 1 1 1 1 1 1

1 1 1 1 1 1 22

1 1 1 1 1

12 21 1 1

• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.• Fifth Terminal: For field mounted fifth terminal, order catalog number 5T8K2 for the 6-o’clock position, and K9959 for the 9 o’clock position.• Connectors: Extruded aluminum connectors are tin plated.• Bypass: The horn bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.

Notes

U7363-RL-KK

Catalog Number Positions Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2

U7362-RL-KK 2 OH H.O. #6-350 #6-2/0 Horn 41⁄2 165⁄16 16 21⁄2 1⁄4,1⁄2

U7363-RL-KK 3 OH H.O. #6-350 #6-2/0 Horn 41⁄2 241⁄2 16 21⁄2 1⁄4,1⁄2

U7364-RL-KK 4 OH H.O. #6-350 #6-2/0 Horn 41⁄2 3211⁄16 16 21⁄2 1⁄4,1⁄2

U7365-RL-KK 5 OH H.O. #6-350 #6-2/0 Horn 41⁄2 407⁄8 16 21⁄2 1⁄4,1⁄2

U7366-RL-KK 6 OH H.O. #6-350 #6-2/0 Horn 41⁄2 491⁄16 16 21⁄2 1⁄4,1⁄2

100 Amp/Position | 4 Terminals | Multi-Position | Horn Bypass | Ringless

1 1 1 1

1112 2

1 1 1

1 22 17362 7363 7364

1 1 1 1 1 1

111112 2 7365 7366

Page 21: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

21100 AMPMULTI-

POSITIONSOCKETS

Multi-Position Sockets100 Amps | 4 Terminals | Ringless | 300 VAC

U2692-XL-KK

• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.• Fifth Terminal: For field mounted fifth terminal, order catalog number 5T8K2 for the 9 o’clock position.• Connectors: Extruded aluminum connectors are tin plated.• Bypass: The horn bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.

Notes

CatalogNumber

Positions Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4

U2692-XL-KK 2 OH C.P. #2-350 #6-2/0 Horn 41⁄8 8 251⁄4 21⁄2 11⁄2 11⁄4 1⁄4

100 Amp/Position | 4 Terminals | Multi-Position | Horn Bypass | Ringless

26921

22

3 3

4

Page 22: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

22200 AMPMULTI-

POSITIONSOCKETS

Multi-Position Sockets200 Amps | 4 Terminals | Ringless | 300 VAC

U1252-X-KK-K1-PED(shown without pedestal)

Catalog Number Positions Service HubConnectors CU/AL

BypassDimensions

Line Load D" W" H"

U1252-X-KK 2 OH C.P. 3⁄8" x 16 Studs #6-350 Horn 51⁄8 261⁄2 14

U1253-X-KK 3 OH C.P. 3⁄8" x 16 Studs #6-350 Horn 51⁄8 343⁄4 14

U1254-X-KK 4 OH C.P. 3⁄8" x 16 Studs #6-350 Horn 51⁄8 427⁄8 16

U1252-X-KK-K1-PED 2 UG† C.P. #6-350 #6-350 Horn 51⁄8 261⁄2 14

U1253-X-KK-K3-PED 3 UG† C.P. #4-600 #6-350 Horn 51⁄8 343⁄4 14

U1254-X-KK-K3-PED 4 UG† C.P. #4-600 #6-350 Horn 51⁄8 427⁄8 16

U1255-X-KK-K4-PED 5 UG† C.P. (2) #2-600 #6-350 Horn 51⁄8 541⁄2 16

U1256-X-KK-PED 6 UG† C.P. 3⁄8" x 16 Studs #6-350 Horn 51⁄8 631⁄16 18

200 Amp per Position | 4 Terminal | Multi-Position | Horn Bypass | Ringless

Notes

• †Underground Applications: For underground service, order S2291-TO pedestal raceway. A 12” pedestal extension kit is also available — order catalog number S2571. • Knockouts: See next page for knockout configuration information.• Hubs: For proper hub selection, refer to the hub suffix chart in the accessories section. Two hub openings are supplied (5 and 6 position units only) and the extra opening is closed with a closing plate as standard. To use a hub smaller than 3", the S8324 adaptor is required.• Fifth Terminal: For field mounted fifth terminal, order catalog number K5T (9 o’clock position).• Connectors: Units supplied with 3⁄8"-16 hex head nuts with Belleville washers on line side. Order connector kits K1539 (350 kcmil), K1540 (600 kcmil), or K1541 ((2) 600 kcmil).• Bypass: The horn bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.

Page 23: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

23200 AMPMULTI-

POSITIONSOCKETS

Multi-Position SocketsU1252 Series | Knockout Information

Knockouts (Pedestal Units)

1

21⁄2

Knockouts (Non-Pedestal Units)

1 2 3 4 5

3 21⁄2 1 1⁄2 1⁄4

1 1 1 1 1 1

1 1 1 1 1 1

1

PED

1 1 1 1 1

1 1 1 1 1

1

PED

1 1 1

1 1 1

1

PED

1 1 1

11 PED

1 1 1 1

1 1 1 1

1

PED

12 234 5 4

2 22

12 4 453

2 2 2 2

2 2 12 2 3 25 2

22222

4 4 4 41

1252 1253 1254

1255 1256

Page 24: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

24200 AMP

LEVER BYPASSMULTI-POSITION

SOCKETS

Lever Bypass Multi-Position Sockets200 Amps | 5 Terminals | Ringless | 600 VAC

2 2 2 2

2 2 21 1 3 2

22

2 231 1

2 2

287428732872

• Connectors: Units supplied with 3⁄8”-16 hex head nuts with Belleville washers on line side. Order connector kits K1539 (350 kcmil), K1540 (600 kcmil), K1350 ((2) 350 kcmil) or K1541 ((2) 600 kcmil).• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.• Fifth Terminal: Fifth terminal is in 6-o’clock position unless part number includes -5T9, which is in the 9-o’clock position.• MGE Applications: Contact Madison Gas and Electric for approval and mounting instructions.

Notes

U2873-XT

Catalog Number Positions Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3

U2872-XT 2 OH (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 321⁄8 251⁄4 4 21⁄2 1⁄4,1⁄2

U2872-XT-K3 2 OH (2) C.P. #4-600 #6-350 Lever 6 321⁄8 251⁄4 4 21⁄2 1⁄4,1⁄2

U2872-XT-5T9-K3 2 OH (2) C.P. #4-600 #6-350 Lever 6 321⁄8 251⁄4 4 21⁄2 1⁄4,1⁄2

U2873-XT 3 OH (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 423⁄16 251⁄4 4 21⁄2 1⁄4,1⁄2

U2873-XT-K3 3 OH (2) C.P. #4-600 #6-350 Lever 6 423⁄16 251⁄4 4 21⁄2 1⁄4,1⁄2

U2874-XT 4 OH (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 521⁄4 251⁄4 4 21⁄2 1⁄4,1⁄2

U2874-XT-K3 4 OH (2) C.P. #4-600 #6-350 Lever 6 521⁄4 251⁄4 4 21⁄2 1⁄4,1⁄2

200 Amps per Position | 5 Terminals | Multi-Position | Ringless

2 2

21 1 3 22

2 2

2 2 2 2 2

2 2 1 1 3 2 2 2

2 2 2

1 1 3

2 2 2 2 2

2 2 2 2 2 22875 2876

Page 25: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

25200 AMP

LEVER BYPASSMULTI-

POSITIONSOCKETS

Lever Bypass Multi-Position Sockets200 Amps | 7 Terminals | Ringless | 600 VAC

U2732-XT-PED(shown without pedestal)

• Knockouts: See next page for knockout configuration information.• Hubs: Units supplied with two closing plates. To order as extra, refer to the hub suffix chart in the accessories section.• Connector Kits: For line side connector kits, order as extra K3082 (350 kcmil), K3441 (600 kcmil), K3442 (twin 350 kcmil),

or K3083 (twin 600 kcmil). Line connectors can be reversed to change from overhead to underground service.• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.• Underground Applications: For underground service, order S2291-TO raceway. A 12" pedestal extension kit is also

available—order catalog number S2571.• MGE Applications: Contact Madison Gas and Electric for approval and mounting instructions.

Notes

Catalog Number Positions Service HubConnectors CU/AL Dimensions

Line Load D" W" H"

U2732-XT-PED 2 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 321⁄8 251⁄4

U2732-XT-PED-K7 2 OH/UG (2) C.P. #4-600 #6-350 6 321⁄8 251⁄4

U2733-XT-PED 3 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 423⁄16 251⁄4

U2733-XT-PED-K7 3 OH/UG (2) C.P. #4-600 #6-350 6 423⁄16 251⁄4

U2734-XT-PED 4 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 521⁄4 251⁄4

U2734-XT-PED-K7 4 OH/UG (2) C.P. #4-600 #6-350 6 521⁄4 251⁄4

U2735-XT-PED 5 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 625⁄16 251⁄4

U2735-XT-PED-K7 5 OH/UG (2) C.P. #4-600 #6-350 6 625⁄16 251⁄4

U2736-XT-PED 6 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 723⁄8 311⁄4

U2736-XT-PED-K7 6 OH/UG (2) C.P. #4-600 #6-350 6 723⁄8 311⁄4

200 Amps per Position | 7 Terminals | Multi-Position | Ringless

Page 26: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

26200 AMP

LEVER BYPASSMULTI-

POSITIONSOCKETS

Lever Bypass Multi-Position SocketsU2732 Series | Knockout Information

1 1 1 1

1 1 1PED 2 1

1

1

1 12

1 1

PED2732

2733 2734

1 1

1PED 2 11

1 1

1 1 1 1 1

1 1 2 1PED 1 1

11 1

2

1 1 1 1 1

1 1 1 PED 1 1 12735 2736

Knockouts

1 2

21⁄2 1⁄4,1⁄2

Page 27: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

27125–200 AMP

MULTI-POSITION

METER MAINS

Multi-Position Meter Mains125-200 Amps | 4 Terminals | Ringless | 120/240 VAC

Catalog Number Amps Positions Service HubConnectors CU/AL

BypassDimensions Weight

(lbs.)Line Load D" W" H"

U5902-X-KK-K1-PED 125 2 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 261⁄2 30 58

U5903-X-KK-K1-PED 125 3 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 345⁄9 30 88

U5904-X-KK-K1-PED 125 4 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 424⁄5 30 107

U5905-X-KK-K1-PED 125 5 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 511⁄20 30 128

U5906-X-KK-K1-PED 125 6 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 593⁄10 30 146

Catalog Number Amps Positions Service HubConnectors CU/AL

BypassDimensions Weight

(lbs.)Line Load D" W" H"

U5882-X-KK-K1-PED 200 2 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 261⁄2 30 58

U5883-X-KK-K1-PED 200 3 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 345⁄9 30 88

U5884-X-KK-K1-PED 200 4 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 424⁄5 30 107

U5885-X-KK-K1-PED 200 5 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 511⁄20 30 128

U5886-X-KK-K1-PED 200 6 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 593⁄10 30 146

125 Amps per Position | 4 Terminals | Multi-Position Meter Mains | Horn Bypass | Ringless

200 Amps per Position | 4 Terminals | Multi Position Meter Mains | Horn Bypass | Ringless

• Knockouts: See drawings on the next page.• Alliant Energy Use: For use on Alliant Energy lines, omit the -PED from the catalog number.• AIC Rating: All models are rated 22K AIC when used with approved breakers rated at 22K.• Hub: Units supplied with one (1) closing plate. Order hubs separately, see the accessories page.• Fifth Terminal: For field installed fifth terminal, order K5T. • Underground Applications: Order the S2291-TO pedestal raceway.

Notes

U5882-X-KK-K1 U5884-X-KK-K1

Breaker Chart - 10K AIC (unless noted 22K)

Manufacturer Cutler Hammer Siemens G.E. (50 Amp Max) Square D

125 Amps or Less BR, HQP, QPGF QP, QPH (22K) THQL, THQL-GF Homeline

150-200 Amp BR, BJ QN, QNH (22K) — —

Page 28: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

28125-200 AMP

MULTI-POSITION

METER MAINS

Multi-Position Meter MainsU5882 & U5902 Series | Knockout Information

30"

26.5"

1 34 45 22

2 2

58825902

5.125"

30”

26.5”

2

2

2

2

5.13”

PED

34.56"

30"

12 3 22 158835903

5.125"

30”

5.13”34.56”

2 2 2PED

2 2 2 2

30”

42.81” 5.13”

PED

30"

51.06"5.125"

1 12 2 2 2 2358855905

30”

51.06” 5.13”

2 2 2 2 2PED

1 12 2 2 2 2 23

30"

59.31"5.125"

58865906

2 2 2 2 2 2

30”

59.31” 5.13”

PED

58825902

5884 5904

5885 5905

58835903

Knockouts

1 2 3 4 5

3 21⁄2 1 7⁄8 1⁄4

30"

42.81" 5.125"

1 3 1 222 2

Page 29: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

2920 AMP

TRANSFORMERRATED SOCKETS

1

1 1 1 2

12

1

4

33

2

Transformer Rated Meter Sockets20 Amps | 5–13 Terminals | Ringless

1 1

1 211

UC7448-XL

744874497532

12901299

38873889

Catalog Number TerminalsMeter Form

Cover Service HubConnectors

CUBypass

Dimensions Knockouts

D" W" H" 1 2 3 4

UC1290-RL 5 3S 1-Piece OH/UG H.O. #14-2 Max Plunger 35⁄16 8 14 2 11⁄2 11⁄4 1⁄4

UC1299-RL 6 4S 1-Piece OH/UG H.O. #14-2 Max Plunger 35⁄16 8 14 2 11⁄2 11⁄4 1⁄4

UC7532-XL 6 4S 2-Piece OH/UG C.P. #14-2 Max None 41⁄8 12 20 11⁄4 1⁄4,1⁄2 — —

UC7448-XL 8 5S 2-Piece OH/UG C.P. #14-2 Max None 41⁄8 12 20 11⁄4 1⁄4,1⁄2 — —

UC3887-XL 8 5S 1-Piece OH/UG C.P. #14-2 Max None 5 13 19 11⁄4 1⁄4,1⁄2 — —

UC7449-XL 13 6, 8, 9 & (ALT) 10S 2-Piece OH/UG C.P. #14-2 Max None 41⁄8 12 20 11⁄4 1⁄4,1⁄2 — —

UC3889-XL 13 6, 8, 9 & (ALT) 10S 1-Piece OH/UG C.P. #14-2 Max None 5 13 19 11⁄4 1⁄4,1⁄2 — —

20 Amps | Transformer Rated Meter Sockets | Ringless

Notes

• Hubs: For proper hub selection, see the hub suffix chart in the accessories section.• UC1290 and UC1299: These units do not have a test switch provision.• Pre-wiring: If factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch

model and number, and meter form number. Please be sure to provide a copy of your wiring diagram.• Utility Approval: For utility approval information see pages 69-71.

Page 30: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

3020 AMPMULTI-

POSITIONTRANSFORMER

RATED

Multi-Position Transformer Rated20 Amps | 8–13 Terminals | Ring Type

1

1 2 1

1 1

UC2428-XL

24272428

Catalog Number TerminalsMeter Form

Cover Service HubConnectors

CUBypass

Dimensions Knockouts

D" W" H" 1 2

UC2427-XL 8 5S 2-Piece OH/UG C.P. #14-2 Max None 41⁄8 241⁄16 20 11⁄4 1⁄4,1⁄2

UC2428-XL 13 6, 8, 9 & (ALT) 10S 2-Piece OH/UG C.P. #14-2 Max None 41⁄8 241⁄16 20 11⁄4 1⁄4,1⁄2

20 Amps | Transformer Rated Meter Sockets | Ring Type

• Sealing Rings: These units are supplied with two MR-4 screw type sealing ring.• Hubs: For proper hub selection, see the hub suffix chart in the accessories section.• Pre-wiring: If factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram.• Utility Approval: For utility approval information see pages 69-71.

Notes

Page 31: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

31200 AMP

LEVER BYPASSMETER

PEDESTALS

Meter Socket Pedestals200 Amps | 4 Terminals | Ringless | 600 VAC

Notes

• Extension Unit: For 15” burial applications for the U3358, order extension unit K5800; for 30” burial applications, order two of K5800. For the U1783, order S8988.

• Fifth Terminal: For field-mounted fifth terminal, order K5T to install in the 9-o’clock position.• Horn Bypass: The -KK horn bypass is factory installed and permits changing and testing of the meter without interrupting

customer service when used with utility-supplied jumpers.• Short Circuit Current Rating: The U3358 has a 30K SCCR rating.*U3358: K6366 can be used when dual line side lugs are needed.

Catalog Number Positions Terminals Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3

U3358-O-KK* 1 4 UG Blank #6-350 #6-350 Horn 41⁄8 9 62 2 3⁄4 —

U1783-O-KK 2 4 UG Blank #6-350 #6-350 Horn 41⁄2 81⁄5 74 21⁄2 11⁄3 1⁄2

200 Amp | Meter Pedestals | Horn Bypass | Ringless

1

1

1

2

2

1

1

U1783-O-KKU3358-O-KK

3358 1783

1 1

1 1 1

3

2

3

Page 32: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

32200 AMP

LEVER BYPASSMETER

PEDESTAL

Lever Bypass Meter Pedestals200 Amps | 5 & 7 Terminals | Ringless | 600 VAC

U9107-O-WI

• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.• Neutral Disconnect: The U9108 has a manual neutral disconnect bolt.• Direct Burial: For free standing use, order separately burial kit S3488.• U9108 Single Phase: To use U9108-O-WI in single phase applications, field install kit K6027 (ordered separately).• MGE Applications: The U9108 is for 3-phase use only on Madison Gas and Electric lines.

Notes

Catalog Number Terminals Phase Service HubConnectors CU/AL Dimensions Knockouts

Line Load D" W" H" 1 2

U9108-O-WI 5 1Ø3W or 3Ø3W UG Blank #6-350 #6-350 6 11 58 21⁄2 5⁄16

U9107-O-WI 7 3Ø4W UG Blank #6-350 #6-350 6 11 58 21⁄2 5⁄16

U9107-O-CECHA 7 3Ø4W UG Blank #6-350 #6-350 6 11 58 21⁄2 5⁄16

200 Amps | Metered Pedestals | Lever Bypass | Ringless

1 1 1

2

2 2

2

91079108

Page 33: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

33200 AMP

LEVER BYPASSMETER

PEDESTALS

Lever Bypass Meter Pedestals200 Amps | 4 & 5 Terminals | Ringless | 600 VAC

Catalog Number Terminals Voltage Service HubConnectors CU/AL Dimensions Knockouts

Line Load D" W" H" 1

U4724-O 4 600 UG Blank 3/0-4/0 #6-350 6 11 64 21⁄2

U4724-O-5T9 5 600 UG Blank 3/0-4/0 #6-350 6 11 64 21⁄2

200 Amps | Metered Pedestals | Lever Bypass | Ringless

• Lever Bypass: Lever provides clamping action on meter spades and also operates bypass device.• Fifth Terminal Kit: For field-installed fifth terminal, order catalog number K3865 (neutral wire provided). Units with -5T9 suffix supplied with fifth terminal factory installed at 9 o’clock.• MGE Applications: The U4724-O-5T9 is for single phase, three wire use only on Madison Gas and Electric lines.

Notes

U4724-O-5T9

4724

1 1 1

Page 34: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

34100-200 AMPMETER MAINPEDESTALS

Meter Main Pedestal100–200 Amps | 4 Terminals | Ringless | 120/240 VAC

Grade Line

1

1

NU8980-O-200-KK

8980

100 & 200 Amp | 4 Terminal | Horn Bypass | Ringless

Catalog Number Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1

NU8980-O-KK UG Blank #6-350 CB* Horn 6 9 79 21⁄2

NU8980-O-KK-LP UG Blank #6-350 CB* Horn 6 9 70 21⁄2

NU8980-O-SF100-KK UG Blank #6-350 #6-1/0 Horn 6 9 79 21⁄2

NU8980-O-SF100-KK-LP UG Blank #6-350 #6-1/0 Horn 6 9 70 21⁄2

NU8980-O-200-KK UG Blank #6-350 1/0-300 Horn 6 9 79 21⁄2

NU8980-O-200-KK-LP UG Blank #6-350 1/0-300 Horn 6 9 70 21⁄2

* Field installed circuit breaker required.• Series Wired Main: For series wired main, order wire kit K4714 for black interior and the K5194 for red interior and

UQFPH-M type circuit breaker.• SF: SF in catalog number has small frame plug-in type circuit breaker installed on middle stabs of 4-circuit

interior. Only two single pole spaces available.• Fifth Terminal: For field-installed 5th terminal order kit K5T. Mounts in 9 o’clock position only.• Extension Kit: Available for low profile (-LP) units only. Order kit K4694.• Branch Circuit Breakers (Four Additional Single Pole Spaces): Branch interior accepts most manufacturers’ small frame

plug-in type circuit breakers (GE, Siemens, Cutler Hammer, Murray). Load center rated up to 125 amps max.

Notes

Page 35: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

35100-200 AMPMETER MAIN

W/ LOAD CENTERPEDESTALS

Meter Main with Load Center Pedestal100–200 Amps | 4 Terminals | Ringless | 120/240 VAC

100 & 200 Amps | 4 Terminal | All-In-One Pedestal | Horn Bypass | Ringless

100 & 200 Amps | 4 Terminal | All-In-One Pedestal | Lever Bypass | Ringless

Catalog Number Service Bypass CircuitsConnectors CU/AL Dimensions Knockouts

Line Load D” W” H” 1 2 3 4 5

U5925-O-100-KK UG Horn 10 #6-350 CB 37⁄16 14 78 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2

U5925-O-150-KK UG Horn 8 #6-350 CB 37⁄16 14 78 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2

U5925-O-200-KK UG Horn 8 #6-350 CB 37⁄16 14 78 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2

Catalog Number Service Bypass CircuitsConnectors CU/AL Dimensions Knockouts

Line Load D” W” H” 1 2 3

U6221-O-100-10GR* UG Lever 10 #6-350 CB 41⁄8 911⁄16 80 2 1⁄2 1⁄4

U6221-O-200-10GR* UG Lever 8 #6-350 CB 41⁄8 911⁄16 90 2 1⁄2 1⁄4

Notes

• Fifth Terminal: For field installed fifth terminal, order K5T.• Branch Circuit Breakers: Branch interior accepts most manufacturers’ small frame plug-in type circuit breakers (GE, Siemens, Cutler Hammer, Murray).• U6221 with 10GR has the 520GR included.* When used in an Alliant territory the U6221 must have a shielded GFI receptacle. Use kit number K6265-HRD.

U5925-O-200-KK U6221-O-100-10GR

1

2 3

3

4

5

2 2

1

1

Grade Level

24”

46.875”

78”

14”3.4”

4.5”

Grade Level

24”

48”

80”

911/16”41/8 ”

4.5”

1 1 1

23

5925

6221

K5815Large QN with small frame Q

K5820 Large frame QN with large frame

QN

K5830 Small frame Q to

small frame Q

Generator Interlock (compatible with U5925)

Page 36: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

36200 AMP

METER MAINW/ LOAD CENTER

PEDESTALS

Meter Main with Load Center Pedestal200 Amps | 4 Terminals | Ringless | 120/240 VAC

U5136-O-200S

24”

27.5”

50”

80”

Grade Level

1

1

2 2

3 3

1

1

9.875”4.13”

16.07”

51365137

200 Amps | 4 Terminals | Meter Main Pedestal | Horn Bypass | Ringless

Catalog Number ServiceAIC

RatingConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3

U5136-O-100S UG 22K #6-350 CB Horn 41⁄8 97⁄8 80 2 1⁄2,3⁄4 1⁄4

U5136-O-150S UG 22K #6-350 CB Horn 41⁄8 97⁄8 80 2 1⁄2,3⁄4 1⁄4

U5136-O-200S UG 22K #6-350 CB Horn 41⁄8 97⁄8 80 2 1⁄2,3⁄4 1⁄4

U5137-O-100S UG 22K #6-350 CB Horn 41⁄8 97⁄8 80 2 1⁄2,3⁄4 1⁄4

U5137-O-150S UG 22K #6-350 CB Horn 41⁄8 97⁄8 80 2 1⁄2,3⁄4 1⁄4

U5137-O-200S UG 22K #6-350 CB Horn 41⁄8 97⁄8 80 2 1⁄2,3⁄4 1⁄4

Notes

• Fifth Terminal: For field installed fifth terminal, order K5T.• Stabilizer Foot: For field installed stabilizer foot, order K5415.• Penta Bolt Locking: For field installed pedestal fronts penta bolt locking, order K5039.• Receptacles: Consult factory for installed receptacle assemblies.• U5137: Double power head version.• Branch Circuit Breakers (Four Additional Single Pole Spaces): Branch interior accepts most manufacturers’ small frame

plug-in type circuit breakers (GE, Siemens, Cutler Hammer, Murray). Load center rated up to 125 amps max.• Use part number K6265-HRD when adding a 120V 20 amp GFI receptacle in Alliant territory.

Page 37: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

37200 AMP

METER MAINW/ LOAD CENTER

PEDESTALS

Meter Main with Load Center Pedestal200 Amps | 4 Terminals | Ringless | 120/240 VAC

200 Amps | 4 Terminals | Meter Main Pedestal | Horn Bypass | Ringless

Catalog Number Service BypassConnectors CU/AL Dimensions Knockouts

Line Load D" W" H" 1 2 3 4

U5706-O-200S-KK UG Horn #6-350 CB 51⁄2 14 80 21⁄2 2 1 1⁄4,1⁄2

Notes

• Fifth Terminal: For field installed fifth terminal, order K5T.• Branch Circuit Breakers (Four Additional Single Pole Spaces): Branch interior accepts most manufacturers’ small frame

plug-in type circuit breakers (GE, Siemens, Cutler Hammer, Murray). Load center rated up to 125 amps max.• Use part number K6265-HRD when adding a 120V 20 amp GFI receptacle in Alliant territory.

U5706-O-200S-KKPicture shown with bridge

K5400-BRIDGE-3POS installed

5706

1

1

1

1 2

3

3

4

Page 38: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

38

24”

22”

48”

80”

Grade Level

12 2

3 3

1

9.875”4.13”

16.07”

100-200 AMPMETER MAIN

W/ LOAD CENTERPEDESTAL

100-200 Amp | 5 Terminal | Meter Main Pedestal | Heavy Duty Lever Bypass | Ringless | 1Ø3W

Catalog NumberMeter

PositionsBypass

Mounting Type

Number of power units

Twin Line Connectors CU/AL

Circuit Provisions

Knockouts

1 2 3

U5701-0-100S Single Lever D.B. Post 1 #6-350 4 2 3⁄4 1⁄4

U5701-0-150S Single Lever D.B. Post 1 #6-350 4 2 3⁄4 1⁄4

U5701-0-200S Single Lever D.B. Post 1 #6-350 4 2 3⁄4 1⁄4

• Lever Bypass: Lever provides clamping action on meter spades and also operates bypass device.• Breakers: Quadplex style breakers may be used in accordance to the NEC. If main breaker is used, there are provisions for

two 2-pole breakers or four 1-pole breakers in series.• Kits: For 5701 and 5702 order stabilizer kit K5415. For 5703 order pad mount kit K5035. • If receptacles are required contact factory for additional kit information. Two outlet devices maximum can be installed.• *The U5702 is a back to back unit with 2 power heads.

Notes

Meter Main with Load Center Pedestal100-200 Amp | 5 Terminal | HD Lever Bypass | Ringless

120/240 VAC

U5701-O-200SPicture shown with bridge

K5400-BRIDGE-3POS installed

5702*

Page 39: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

39200 AMP

METER MAINW/ LOAD CENTER

PEDESTALS

Meter Main with Load Center Pedestal200 Amps | 5 Terminals | Lever Bypass | 120/240 VAC

12"

21"

55"

5 1/2"

4 1/8"

StabilizerFoot

1 1 1

23

9 7/8"

43224323

200 Amps | 5 Terminals | Meter Main Pedestals | Lever Bypass | Ringless

Catalog NumberMeter

PositionsBypass

Connectors CU/AL CircuitProvisions

Knockouts Dimensions

Line Load 1 2 3 D" W" H"

U4322-O-5T9 Single Lever Twin #6-350 CB 6 2 1⁄2 1⁄4 95⁄8 97⁄8 55

U4323-O-5T9 Double Lever Twin #6-350 CB 6 2 1⁄2 1⁄4 151⁄8 97⁄8 55

Notes

• Lever Bypass: Lever provides clamping action on meter spades and also operates bypass device• Application: The U4322 & U4323 pedestals are suitable for use as service equipment or mobile home service equipment.

K5081/K3188 for direct burial application is included with unit. K5151 for pad mount application must be ordered as extra.• Breakers: These units are wired as parallel mains and have provisions for six circuits: 6 single-pole or 3 double-pole

breakers.• Short Circuit Current Rating: 10K AIC. However, this rating is limited to the lowest interrupting capacity of any circuit

breaker installed. Watthour meter not included in short circuit current rating.• Main Breaker sold separately.

U4322-O-5T9 U4323-O-5T9

Breaker Chart

Manufacturer 150–200 Amps 125 Amps or Less

Cutler Hammer BJ, WBJ Quicklag P BR, HQP

Siemens (ITE) QNR QP

Murray MD MP

G.E. — Q Line

Square D — Homeline

Page 40: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

40320 AMP

METER MAINW/ LOAD CENTER

PEDESTALS

Meter Main Pedestal320 Amps | 4 Terminals

Notes

• Breakers: Supplied from factory with 2 double-pole, Milbank UQFB or UQFBH (22K AIC) bolt-on circuit breakers.• Connectors: The line wire section is supplied with 3/8”-16 studs with hex nuts and captive Bellville washers. For line side

connectors,order as extra catalog numbers K1539 (single-350 kcmil), or K1540 (single-600 kcmil), or for twin K1350 (twin-350 kcmil). Order one kit per unit.

• Extension Kit: For extension kit, order as extra catalog number S1848.• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.• Short Circuit Current Rating: These units are rated 22K AIC. However, this rating is limited to the lowest interrupting

capacity of any circuit breaker installed. Watthour meter not included in short circuit current rating.• Alliant Approved: Limited to 300 amp; U6317 only.

U3849-O-2-200

18"

Grade Line

1 1

2 2

1

Grade Line

2 2

13" O.D.

16-15/16"15"

4-27/32"I.D.

320 Amps | 4 Terminals | Meter Main Pedestal | Ringless | 120/240 VAC

Catalog Number Terminals Service Hub BypassConnectors CU/AL Dimensions Knockouts

Line Load D" W" H" 1 2

U3849-O-200-100 4 UG Blank Lever 3⁄8" x 16 Stud 1/0-300 47⁄8 13 64 21⁄2 5⁄16

U3849-O-2/150 4 UG Blank Lever 3⁄8" x 16 Stud 1/0-300 47⁄8 13 64 21⁄2 5⁄16

U3849-O-2/200 4 UG Blank Lever 3⁄8" x 16 Stud 1/0-300 47⁄8 13 64 21⁄2 5⁄16

3849

S1848

Catalog Number Terminals Service Hub BypassConnectors CU/AL Dimensions Knockouts

Line Load D" W" H" 1 2

U6317-O-2/150-K3L 4 UG Blank Lever 3⁄8” x 16 Studs Twin #6-350 47⁄8 13 64 21⁄2 5⁄16

U6317-O-200-100-K3L 4 UG Blank Lever 3⁄8” x 16 Studs Twin #6-350 47⁄8 13 64 21⁄2 5⁄16

Alliant Approved | 300 Amp | Meter Main with Breakers | Ringless

U6317-O-2/150

1

1

1

1

6317

Page 41: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

41320 AMP

METER MAINW/ LOAD CENTER

PEDESTALS

Meter Socket Pedestal320 Amps | 4 & 5 Terminals

Notes

• Connectors: On the U1748-O-WI and U1748-O-5T9-WI, the connectors K1539 (single-350 kcmil) are factory installed on the line side. Load side is furnished with K1350 (twin-350 kcmil).

• Extension Kit: For extension kit, order as extra catalog number S1848.• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.• Hanging Hook: Units supplied with hanger hooks for easy mounting.• Short Circuit Current Rating: These units are rated 22K AIC. Watthour meter not included in short circuit current rating.

U1748-O-WI

13" O.D.

16-15/16"15"

4-27/32"I.D.

Grade Line Grade Line

1

2 218”

1 1

11

2 2

320 Amps | Ringless | 600 VAC

Catalog Number Terminals Service Hub BypassConnectors CU/AL Dimensions Knockouts

Line Load D" W" H" 1 2

U1748-O-WI 4 UG Blank Lever #6-350 (2) #6-350 47⁄8 13 64 21⁄2 5⁄16

U1748-O-5T9-WI 5 UG Blank Lever #6-350 (2) #6-350 47⁄8 13 64 21⁄2 5⁄16

1748 S1848

Page 42: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

42JOINT USE

TERMINATIONCABINETS

Grade Line

12"

58"

13" 4 1/2"

37 5/16" 33 5/16" 39"

21"

6"1

1

1 1

1

2

3

1

1

4329

Joint Use Termination Cabinet

Catalog Number Hub BypassConnectors CU/AL Dimensions Knockouts

Line Load D" W" H" 1 2 3

U4329-O Blank None None None 47⁄8 13 58 1 1⁄2 7⁄16

Notes

• Communication Compartment: Easily attaches to Milbank meter pedestals for use in new construction.• Telephone and Cable Conductors: This unit will accommodate both telephone and cable conductors, eliminating the use

of multiple, unsightly network interface devices on the outer structure of the home, while providing tamper resistance to the communication modules.

• Single Location Point of Service: The U4329 combined with the Milbank meter pedestal provides a single location point of service, making access for utility service personnel convenient and efficient.

U4329-O

Joint Use Termination CabinetAccommodates telephone and cable conductors

Page 43: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

43POLYPHASE

ENCLOSURES

Glass Window Demand Reset Cover All Metal Demand Reset Cover Window Shield

SDRCW SDRC WS

Polyphase EnclosuresFor “A” Base Meters

Pole Mounting BracketsOrder #830 for one pair (2 pcs.) with keyhole

bracket and mounting hardware. Order #850 for two pair (4 pcs.) with

mounting hardware.

Notes

• Bridge and Mounting Board: Units are supplied with board and bridge.• Windows and Covers: Units supplied with one 41⁄2" x 6 glass window per meter position. If glass demand reset window is

desired, add suffix -CW to the catalog number. If metal demand reset cover is desired, add suffix -C to the catalog number. If window shield is desired, add suffix -WS to the catalog number.

• Hubs: Units supplied with closing plate. Order hub as extra; refer to the accessories page.

S9997-B-XL S9997-B-XL

830 850

Polyphase Enclosures

Field Installed Accessories

Catalog Number Hub PositionsDimensions

D" W" H"

S9995-B-XL C.P. 1 11 15 26

S9996-B-XL C.P. 1 11 15 3011⁄16

S9997-B-XL C.P. 2 11 27 3011⁄16

Page 44: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

44TYPE K4

METER SOCKETS

Type K4 Meter Sockets4 Terminals | 480 Amps Cont. | Ringless | 300 VAC

U4664-X

1 1

2 2 3

1

1 1 1

CatalogNumber

Service HubL & G

NumberLugKit

Connectors CU/AL Dimensions Knockouts

Line Load D" W" H" 1 2 3

U4664-X-8502 OH/UG C.P. 9810-8502 Installed Twin #6-350 Twin #6-350 6 173⁄4 36 4 1⁄2,3⁄4 1⁄4

U4664-X-8507 OH/UG C.P. 9810-8507 None 1⁄2-20 Stud 1⁄2-20 Stud 6 173⁄4 36 4 1⁄2,3⁄4 1⁄4

U4664-XT-9507 OH/UG (2) C.P. 9810-9507 None 1⁄2-20 Stud 1⁄2-20 Stud 6 173⁄4 36 4 1⁄2,3⁄4 1⁄4

480 Amps | 4 Terminals | Ringless | Type K4 Meter Sockets

Notes

• Application: For use with 1Ø3W self-contained Type MS-K watthour meters.• Capacity: 480 amp continuous, 600 amp maximum.• Connectors: 1⁄2"-20 plated steel studs with nuts and captive Belleville washers to accommodate various bolt-on type lugs

for conductors from #6 to 800 kcmil CU or AL. Use 3⁄4" insulated wrench to fasten connectors to block. U4664-X8502 includes phase and neutral connectors. For lugs, refer to page 45.

• Enclosure: Constructed of 14-gauge galvanized steel suitable for indoor or outdoor installations.• Bypass: Rated 50%, separate manual type, order Milbank kit #K4687 (kit includes 2 bypasses).• Meter Mounting: Two position stud type. One set of studs provides out-of-service storage. The in-service studs are

positioned so the meter cannot be installed upside-down. Full travel meter opening slide plate eliminates the need for repositioning the slide plate for the “IN” or “OUT OF SERVICE” position.

• Blocks: Glass fiber reinforced polyester plastic. High arc withstand strength and track resistant. Provisions for lighting arresters.

4664

Page 45: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

45TYPE K7

METER SOCKETS

Type K7 Meter Sockets7 Terminals | 480 Amps Cont. | Ringless | 600 VAC

U4667-X-8013

CatalogNumber

Service HubL & G

NumberLugKit

Connectors CU/AL Dimensions Knockouts

Line Load D" W" H" 1 2 3

U4667-X-8512 OH/UG C.P. 9817-8512 Installed Twin 4-500 Twin 4-500 6 201⁄4 43 4 1⁄2,3⁄4 1⁄4

U4667-XT-9504 OH/UG (2) C.P. 9817-9504 None 1⁄2-20 Stud 1⁄2-20 Stud 6 201⁄4 43 4 1⁄2,3⁄4 1⁄4

U4667-XT-9506 OH/UG (2) C.P. 9817-9506 Installed Twin 4-500 Twin 4-500 6 201⁄4 43 4 1⁄2,3⁄4 1⁄4

U4667-X-8013 OH/UG C.P. 9817-8013 Installed Twin 4-500 Twin 4-500 6 201⁄4 43 4 1⁄2,3⁄4 1⁄4

480 Amps | 7 Terminals | Ringless | Type K7 Meter Sockets

Notes

• Application: For use with self-contained Type MT-K watthour meters on 3Ø4W Wye or 4-wire delta services.• Capacity: 480 amp continuous, 600 amp maximum.• Connectors: 1⁄2"-20 plated steel studs with nuts and captive Belleville washers to accommodate various bolt-on type lugs

for conductors from #6 to 800 kcmil CU or AL. Use 3⁄4" insulated wrench to fasten connectors to block. For lugs, refer to page 46.

• Enclosure: Constructed of 14-gauge galvanized steel suitable for indoor or outdoor installations.• Bypass: Rated 50%, separate manual type, order Milbank kit #K4688 (kit includes 3 bypasses).• Meter Mounting: The meter is mounted on 6 studs using 5⁄16"-24 studs with nuts with captive Belleville washers. The upper

studs are positioned so that the meter cannot be installed upside-down. Use 1⁄2" insulated wrench. Another set of studs provides on site “OUT OF SERVICE” storage. Full travel meter opening slide plate eliminates the need for repositioning the slide plate for the “IN” or “OUT OF SERVICE” position.

1 1 1

1

2 23

1 14667

Page 46: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

46K4/K7 SERIESSCHEMATICS

K4/K7 Series Schematics Wiring and Lug Kit Information

K4 Lug Kit(overhead)

K4 Lug Kit(underground)

K7 Lug Kit(underground)

K7 Lug Kit(underground)

LugMilbank Connector

NumberLine/Load Feed

(OH/UG)Description

K4Z703917-ACZ705456-ACZ705420-AC

ParallelLine/LoadOH/UG

(2) Twin #6-350 kcmil connector (phase)(2) Twin #6-350 kcmil connector (phase)

(1) Quad #6-350 connector (neutral)

K7Z704693-ACZ704694-AC

ParallelLine/Load

UG

(3) Twin #2-500 kcmil connector (phase)(5) Twin #4-500 kcmil connector (phase)

K7Z703919-ACZ703918-AC

ParallelLine/Load

UG

(3) Twin #6-350 kcmil connector (phase)(5) Twin #4-350 kcmil connector (phase)

Milbank Bypass L&G Bypass Description

K4687 56495 Manual bypass for K-4 Series (U4664). Kit includes 2.

K4688 58888 Manual bypass for K-7 Series (U4667). Kit includes 3.

Notes

• Bypass: Rated 50%, separate manual type.

Page 47: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

47LUGS FORK-SERIES

Lugs for K-SeriesL&G Cross-Reference

H

L

W

Milbank ConnectorNumber

L&G Connector Number

# of Conductorsand Size

StudOpening

Pressure Screw Head

DimensionsL" W" H"

Z703916-AC 58852 3/0-800 kcmil 9⁄16” 1⁄2” Allen 315⁄16 13⁄4 113⁄16

Z703917-AC 56427 Two #6-350 kcmil 9⁄16” 5⁄16” Allen 45⁄16 11⁄8 21⁄16

Z703918-AC 56732 Two #4-350 kcmil 9⁄16” 5⁄16” Allen 27⁄8 159⁄64 11⁄4

Z703919-AC 58853 Two #6-350 kcmil 9⁄16” 5⁄16” Allen 315⁄16 11⁄8 11⁄2

Z703921-AC 56476 3/0-800 kcmil 9⁄16” 1⁄2” Allen 31⁄4 15⁄16 113⁄16

Z704693-AC 56427-M Two #2-500 kcmil 9⁄16” 3⁄8” Allen 41⁄4 11⁄8 113⁄16

Z704694-AC 56732-M Two #4-500 kcmil 9⁄16” 3⁄8” Allen 213⁄16 25⁄32 113⁄16

Z705420-AC 56426 Four #6-350 kcmil 17⁄32” 5⁄16” Allen 27⁄8 315⁄16 19⁄16

Z705456-AC 56425 Two #6-350 kcmil 9⁄16” 5⁄16” Allen 27⁄8 157⁄64 11⁄4

Z708145-AC 68752-1 Three #6-250 kcmil 9⁄16” 5⁄16” Allen 27⁄8 21⁄2 15⁄16

#Z703916-AC | #58852

#Z703921-AC | #56476 #Z705420-AC | #56426 #Z705456-AC | #56425

#Z708145-AC

#Z703918-AC | #56732#Z704694-AC | #56732-M

#Z703919-AC | #58853#Z704693-AC | #56427-M

Bolt-on type lugs for Milbank stud type meter mounting devices are made of 6061-T6 aluminum to provide high strength and high conductivity. All lugs are tin-plated to ensure low contact resistance and to reduce corrosion. Allen or hex head pressure screws are furnished to provide excellent conductor spread for maximum binding action with the lug.

Page 48: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

48COMMERCIALPEDESTALS

Commercial PedestalsAttractive | Easy to Install | Secure | Cost-Effective

Milbank Commercial Pedestals are pad-mounted, weather resistant electrical enclosures consisting of a utility pull section with optional meter socket, and a customer section containing distribution and control equipment. Milbank Commercial Pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures.

UL Listed as Industrial Control Equipment (File E113855)

Strut and backboard Commercial pedestal

• Type 3R rain-resistant, vandal-resistant cabinet of polyurethane powder coated steel (aluminum or stainless steel also available)• UL listed as enclosed industrial control equipment (UL508)• Isolated lockable and sealable utility metering and lug landing sections• Lockable customer section for distribution and control equipment with internal deadfront• Print pocket inside customer section door contains wiring schematics and installation instructions• Most load centers are UL listed for use with various manufacturers’ circuit breakers• All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws)

Standard Features Note

All meter form and bypass options

available to meet utility requirements.

Page 49: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

49COMMERCIALPEDESTALS

K3865Fifth terminal kit for use with ringless meter sockets

CP-ABK5/8Anchor bolt kit (includes four 5⁄8 - 13 x 18” anchor bolts

105JFifth terminal kit for use with ring type meter sockets

CP-PE-HOA-3POSHOA switch for field installation

CP-TC7D 7-day time clock kitCP-TC24H24-hour time clock kitCP-TCWIREMale 4-pin connector and wiring harness for use with time clocks other than above

CP-16PDMNT-CALT 16" pedestal mounting baseCP-24PDMNT-CALT 24” pedestal mounting base (includes mounting hardware)

Commercial PedestalsAttractive | Easy to Install | Secure | Cost-Effective

Accessories

These units are ideal for controlling and metering:• Traffic signals• Street lighting• Power distribution for EV charging stations• Irrigation and sprinkler systems• Cell towers and telephone vaults• Pump stations• Temporary power for fairgrounds, swap meets, outdoor markets,

portable offices, holiday lights, etc.• Outdoor lighting for athletic fields, tennis and basketball courts,

parking lots, landscaping and subdivision entrances, etc.

• Meter sockets: ring type or ringless, up to 400 amp• Main and branch breakers or T fuses• Distribution: copper load centers and panel boards• Clocks, timers and relays• Photoelectric cells and controls• Power receptacles: pin and sleeve, twist lock or straight blade• Contactors: definite purpose, electrical or mechanically held, IEC

and mercury types• Surge protection and lightning arrestors• Reserve inlet generator receptacle with interlocked circuit breakers• Motor starters and relays• Push button controls• Thermostat controls, fans and heating strips• Power blocks and terminal blocks• Steel, aluminum and plywood backboards• Transformers• Interlock devices for circuit breakers• Available in steel, aluminum (raw painted or anodized) or stainless steel

construction with powder coated finish available in eight standard colors or special-ordered RAL colors

• Available for applications up to 400 amp, 120V, 208V, 240V, 277V, 480V - 1Ø or 3Ø

Applications

Available Factory-Installed Options

Page 50: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

50

CP3B “ML” SeriesMain Load Center Series1Ø3 wire 120/240V or 208Y/120VApplication: remote site service for multiple loadsMilbank Main Load Center Commercial Pedestals are designed to handle the vast majority of all requirements in a standard, stocked configuration. • All units feature a load center with a plug-on, back-fed main breaker. • Load center has 16 positions for the 100 amp pedestals and 24 circuits for the 200 amp pedestals. • Both sizes include sub-feed lugs to allow feeding an external panel.

If your application requires turning loads on based on “dusk-to-dawn” requirements, be sure to see the Milbank Switched Load Center Commercial Pedestal products on the following page.

Standard PedestalsOptional Fifth Terminal Kit

Main CB Load Center Circuits

Meter Socket TypeAmp Spaces

CP3B51115A22 K3865 100 1,2 16 Ringless socket with lever bypassCP3B52119A22 K3865 200 1,2,3,4 24 Ringless socket with lever bypass

Typical Applications

Remote site service for multiple loads.

COMMERCIALPEDESTALS

Commercial PedestalsMain Load Center Series | Custom Designs Available

Features

These units include everything required for remote site service:

• NEMA 3R construction.• Expandable: load centers allow for future expansion without costly

modifications.• All units feature 200 amp meter socket with optional field installable

fifth terminal kit available.• 22K amps interrupting capacity (AIC) standard.• Optional mounting base can be embedded in concrete for fast, easy

installation.• Separate sealable and lockable utility termination section.• Separate sealable and lockable metering section.• Separate sealable and lockable customer section with a load center

for “always on” loads that include a main circuit breaker, 20 (125 or 200 amp model) or 14 (100 amp model) blank breaker spaces and a circuit directory to document configuration.

Notes

• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.

Note

All meter form and bypass options

available to meet utility requirements.

Page 51: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

51

Standard PedestalsOptional Fifth Terminal Kit

Main CB Contactor Amperage

Meter Socket TypeAmp Spaces

CP3B51110A22SL1 K3865 100 1,3 60 Ringless socket with lever bypassCP3B52110A22SL1 K3865 200 1,2,3,4 100 Ringless socket with lever bypass

Typical Applications

Traffic signals, parking lots, highways & athletic

field lighting

COMMERCIALPEDESTALS

Commercial PedestalsSwitched Load Center Series | Custom Designs Available

CP3B “SL” SeriesSwitched Load Center Series1Ø3 wire 120/240V or 208Y/120V

Milbank Switched Load Center Commercial Pedestals are designed not only to provide power for various loads, but also to switch specific loads on and off under certain conditions. A photoelectric cell is used for these controlled loads, and an optional time clock is also available.

Notes

• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.

Features

These units include everything required for remote site service:

• NEMA 3R construction.• Expandable: load centers allow for future expansion without costly

modifications.• All units feature 200 amp meter socket with optional field installable fifth

terminal kit available.• 22K amps interrupting capacity (AIC) standard.• Optional mounting base can be embedded in concrete for fast, easy

installation.• Separate sealable and lockable utility termination section.• Separate sealable and lockable metering section.• Separate sealable and lockable customer section with a control circuit

including PE receptacle, Lexan® window, glare shield, Hand-Off-Auto (HOA) switch, contractor controlling a 16-circuit load center for controlled loads, a pre-mounted DIN rail and pre-wired connector to add an optional “plug-and-play” time clock kit for PE on and TC off operation and a circuit directory to document configuration.

• A load center for “always on” loads that includes a main circuit breaker, a control power circuit breaker, a switched load center main breaker, nine (125 or 200 amp model) or 11 (100 amp model) blank breaker spaces and a circuit directory to document configuration.

Note

All meter form and bypass options

available to meet utility requirements.

Page 52: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

52COMMERCIALPEDESTALS

Commercial PedestalsCP3B “400” 400 Amp Series

Standard PedestalsOptional fifth Terminal Kit

Main CB Load Center Circuits Meter Socket Type

CP3B54120B22 K3865 2-200 amp (2) 12 circuit Ringless with lever bypassCP3B5411JB22 K3865 320 amp (400 max) 0 Ringless with lever bypass

Milbank 400 Amp Commercial Pedestals are designed to provide a weather and vandal resistant metered enclosure for various loads and distribution. Each pedestal has been designed to handle a wide range of applications using standard, stocked configurations. • Choice of a single main breaker or twin service disconnect

breakers gives flexibility to the pedestal design. • Optional distribution with feed-through lugs below the

service disconnect breakers allows the pedestal to handle numerous applications.

• Typical applications include remote homes where the metering is best located at the curb side or other remote area. The pedestal can also provide power to secondary residence, on-site business, workshop, irrigation, lighting, security or other secondary load.

• Available in custom colors to match home or landscaping.

Features

These units include everything required for remote service:• Type 3R construction• Main circuit breaker or dual service disconnects• Expandable: load center units allow for future expansion

without costly modifications• Optional mounting base can be embedded in concrete for

fast, easy installation• Separate sealable and lockable utility termination section

with lug termination• Separate sealable and lockable metering section • A separate sealable and lockable customer section with a

circuit directory and a print pocket to hold all documentation• Meter socket options include ring type with bypass studs,

ringless with heavy duty lever bypass, or K-Type bolt-on

Typical Applications

Remote site service for residential and commercial job sites.

Notes

• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.• Stud utility landing is standard. Lug kits are available from factory.

• Units with load centers have (2) #6-250 sub-feed lugs on each load center. (Each load center is 200 amp rated and UL listed with: Siemens, General Electric and Cutler-Hammer plug-in style circuit breakers.)

Page 53: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

53

Features

• 3Ø4W, 480Y/277 volt• One technician can install in under an hour with use of Milbank’s pre-drilled box pad• All units are UL listed and service entrance rated• Fused disconnect with accessible handle through the deadfront• HOA and push button start• Separate accessible utility side with pre-wired landing lugs• NEMA rated starters (sizes 1-5)• Soft start units sizes 30HP-150HP• 30 amp fuse block for pivot pre-wired in the unit• White powder coated paint finish helps keep components cooler • Options include: • Hour meter • Chemical injection receptacle • Multiple injection receptacle • Multiple 30 amp fuse blocks possible

COMMERCIALPEDESTALS

Commercial PedestalsCP3B “IR” Irrigation Control Series

Standard Pedestals Exterior Cabinet NEMA Rating

CP3B0281UMWIR04 White 4CP3B0281UMWIR03 White 3CP3B0181UMWIR02 White 2

Notes

• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.

Milbank “IR” Series Irrigation Pedestals install quickly and simply – often in less than an hour with a single technician—a fraction of the time typically needed for strut farm and other installation set ups. Additionally, the pedestal comes pre-wired, so the technician simply drops in the pre-drilled concrete box pad, fastens the pedestal and runs the wires. Prewired landing lugs are provided in a separate utility side so that there is no more need to wrestle with hard-to-bend wires. Simply run the utility wire up and land on the lugs. With both the motor starter and disconnect in the same enclosure, all the controls are housed in a safe, lockable pedestal that protects against vandalism and energy theft.

Typical Applications

Power pedestal for irrigation systems or other pump control

applications.

Page 54: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

54COMMERCIALPEDESTALS

Commercial PedestalsCP3B “BBS” Battery Backup Series

Milbank BBS Series Commercial Pedestals are designed to provide battery backup power for various loads, and to switch specific loads on and off under certain conditions; a photoelectric cell or time clock to control lighting circuits, as an example. Metered and unmetered power distribution options are available. The back-up power pedestal is designed to handle the vast majority of todays back-up power requirements. By using 19” rack design, shelves can be adjusted to accommodate the required batteries and manufactures DC to AC inverters, transfer switches and other related equipment. This design gives the user a wide range of design and configuration options. Complete turnkey, ready to power-up pedestals are offered along with basic units ready to accept batteries and inverters supplied by others.

Features

• Type 3R construction• 100 through 320 amp meter socket with the option of

either a ring type socket (conforms to EUSERC 308) with or without test/bypass blocks or a heavy duty ringless socket with lever bypass

• Separate sealable utility termination compartment• An isolated separate customer section with service

disconnects, power distribution options and power control • 19” wide rack in customer compartment for easy layout of

equipment• Battery trays• Thermostat with cooling fan• Filtered louvers for heat rise flow through ventilation• Three point door latch (key or pad lockable)

Options

• Manual bypass switch• Transfer switch for generator

power back-up• Generator inlet receptacles 30

amp through 200 amp • Pad lockable provision for

receptacles• Police access door

• Metered load center distribution• Unmetered load center

distribution• Photo electric controls (for street

lighting)• Time clocks• HOA switches• Contactors

• GFI duplex receptacles• Thermostat for heating control• Heating pads or elements• Roll out shelves for batteries• Surge arrestors and lighting

arrestors

Typical Applications

Metered emergency uninterrupted power for traffic intersections, wireless, phone and communications equipment, parking lots,

camera and security locations

Page 55: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

55COMMERCIALPEDESTALS

Commercial PedestalsCP3B “Power Transfer” Series

Milbank Power Transfer Series Pedestals provide unmetered AC power, distribution, surge suppression, mechanical interlock and stand-by generator receptacle— all in a neat, compact pedestal.

Features

• 120/240V 1Ø3W through 277/480V 3Ø4W ratings• Metered or unmetered units• Choice of EUSERC ring type or ringless meter sockets• 60 amp through 400 amp ratings • UL listed Type 3R rated• Pad lockable, isolated utility compartments• 20 amp GFI convenience receptacle• Lockable recessed generator receptacle door • Utility and generator indicator light options• All stainless steel hardware• Galvanized steel, aluminum or stainless steel cabinet

options• Custom designs available

Typical Applications

Traffic intersections, cell sites, cable TV, pump and lift stations requiring utility power with

backup generator power

Page 56: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

56COMMERCIALPEDESTALS

Commercial PedestalsCP3BB “CT Metered” Series

Typical Applications

Large homes, pumping & lift stations, motor control, water treatment plants, EV charging stations, commercial buildings, large remote service

requirements, commercial and industrial control systems

Milbank CT Metered Series Commercial Pedestals are designed to be used where a smaller service package would be a better choice over large 3R rated combination switchboards. These pedestals have amperage ratings of 400 to 800 amps at voltages up through 480 volt three phase.

Features

• UL listed, freestanding Type 3R service• A low profile CT pedestal• All utility equipment is isolated in separated pad

lockable and sealable compartments • Separate customer compartment designed to hold

distribution and control equipment• Dead front customer construction• Optional mounting base• Optional construction in steel, aluminum and stainless

steel.• Wide choice of powder paint colors

Page 57: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

57COMMERCIALPEDESTALS

Commercial Pedestals CP3A “Slimline” Series

Typical Applications

Roadway lighting and signage, wastewater

treatment facilities, parks and landscaping, and any application where physical

space is at a premium

Milbank Slimline Series Commercial Pedestals provide a sleeker, smaller footprint, with wireway access on the side of the unit rather than the back, allowing maximum flexibility to place the pedestal in tighter spaces.

Features• UL listed as service equipment• 100 or 200 amp• Vandal-resistant, secure and attractive design• Customer compartment with distribution and control equipment with

swing dead front door, secured with both a hasp/latch and draw latch outer door

• Utility metering compartment protected with a hinged hood, increasing resistance to meter vandalism

• Small footprint• Wireway located on left side of pedestal for utility incoming wire,

allowing pedestal to be mounted with back very close to a wall (14")• Available in 12" and 20" widths and 50" and 63" (metered) and 43"

(unmetered) heights• Includes a print pocket for plans and drawings• 200 amp main available• Voltage range: 120V–480V• Compatible with both ringless and ring type meter sockets, 4–7

terminals• Available in a wide array of colors, including but not limited too all ANSI

powder coated paint colors upon request• Pedestal mounting base option saves time and labor to install on a

cement pad—no anchor bolts required• Powder coated G90 galvanized steel, raw, anodized or powder coated

aluminum and stainless steel exterior options

“Slimline” Series Direct Bury Extension• No need for concrete• Bolts directly to unit• Easy, modular design• Ships in a smaller package• Increases project flexibility• Easier to handle and install• Utilizes stabilizer feet to prevent leaning over time• Pedestal and extension can be installed within 45 minutes

Notes

• 14 guage steel• Only available for 12” pedestals

Page 58: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

58CIRCUIT

BREAKERS

Circuit BreakersUQFP Plug-In & UQFB Bolt-On Series | 120/240 VAC

UQFPUQFPH

UQFP-MUQFPH-M

200 Amp Frame | Plug-In | 10,000 AIC & 22,000 AIC | Two-Pole - Common Trip

200 Amp Frame | Bolt-On | 10,000 AIC & 22,000 AIC | Two-Pole - Common Trip

Amps10K AIC Plug-In

22K AIC Plug-In

10K AICPlug-In

22K AICPlug-In

Wire Range

CU AL

100 UQFP-100 UQFPH-100 UQFP-M-100 UQFPH-M-100 #3-#1 #1-1/0

125 UQFP-125 UQFPH-125 UQFP-M-125 UQFPH-M-125 #3-#1 #1-1/0

150 UQFP-150 UQFPH-150 UQFP-M-150 UQFPH-M-150 1/0-300 2/0-300

175 UQFP-175 UQFPH-175 UQFP-M-175 UQFPH-M-175 1/0-300 2/0-300

200 UQFP-200 UQFPH-200 UQFP-M-200 UQFPH-M-200 1/0-300 2/0-300

Amps10K AICBolt-On

22K AICBolt-On

10K AICBolt-On

22K AICBolt-On

Wire Range

CU AL

100 UQFB-100 UQFBH-100 UQFB-100-X1 UQFBH-M-100 #3-#1 #1-1/0

125 UQFB-125 UQFBH-125 UQFB-125-X1 UQFBH-M-125 #3-#1 #1-1/0

150 UQFB-150 UQFBH-150 UQFB-150-X1 UQFBH-M-150 1/0-300 2/0-300

175 UQFB-175 UQFBH-175 UQFB-175-X1 UQFBH-M-175 1/0-300 2/0-300

200 UQFB-200 UQFBH-200 UQFB-200-X1 UQFBH-M-200 1/0-300 2/0-300

Notes

• UL listed: For use with 60°C or 75°C wire.• UQFP: For parallel main circuit breaker applications.• UQFP-M: For series main circuit breaker applications. Split load tab features allow for feed-through capability.• UQFB: (2) 1/0-300 lugs provided on load and line side (cable-in, cable-out).• UQFB3: Three-pole available. Consult factory.• UQFB-X: (2) 1/0-300 lugs provided on load side and (2) line bar bus connections on line side.• UQFB-M: For series main circuit breaker applications. Split load tab features allow for feed-through capability.• UQFB-X-MOD: Replacement circuit breaker with line barriers removed.

UQFB-X1 UQFB-X UQFB UQFB-X-MOD

Page 59: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

59CIRCUIT

BREAKERS

Circuit BreakersQP (small frame) and QN (large frame) | 120/240 VAC

QN2200H

Q250

QN2200RH

15–125 Amp BreakerPlug-In Type | 1” Per Pole

Amps Poles10K AIC Plug-In

22K AIC Plug-In

15 Single Q115 Q115H

15 Double Q215 Q215H

20 Single Q120 Q120H

20 Double Q220 Q220H

25 Single Q125 Q125H

25 Double Q225 Q225H

30 Single Q130 Q130H

30 Double Q230 Q230H

35 Single Q135 Q135H

35 Double Q235 Q235H

40 Single Q140 Q140H

40 Double Q240 Q240H

50 Single Q150 Q150H

50 Double Q250 Q250H

60 Single Q160 Q160H

60 Double Q260 Q260H

70 Single Q170 Q170H

70 Double Q270 Q270H

80 Double Q280 Q280H

90 Double Q290 Q290H

100 Double Q2100 Q2100H

125 Double Q2125 Q2125H

• Load connectors supplied with breakers.• UL listed for use with 60°C or 75°C wire.• Wire sizes shown are lug capacity. Consult NEC Article #310 for specific wire sizes.

Notes

200 Amp Frame | Plug-In | 10,000 AIC & 22,000 AIC | Two-Pole, Common Trip

Amps 10K AIC Plug-In 22K AIC Plug-In Handle LocationWire Range

CU AL

150 QN2150 QN2150H Left facing #4-300 #4-300

200 QN2200 QN2200H Left facing #4-300 #4-300

150 QN2150R QN2150RH Right facing #4-300 #4-300

200 QN2200R QN2200RH Right facing #4-300 #4-300

Page 60: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

60 AccessoriesHubs and Closing Plates

-R

Large hub opening

-WL A7514 -YL A7515 -ZL A7516 -DL A7517 -EL A7518 -XL A7551

1" hub 11⁄4" hub 11⁄2" hub 2" hub 21⁄2" hub Small closing plate

-F A8110 -G A8111 -H A8112 -X A9064 -RRL S8324

3" hub 31⁄2" hub 4" hub Large closing plate Large hub opening adapted to small

hub oepning

-RL

Small hub opening

Notes

• Suffix: Add to catalog number for factory installation of hub.• Packaging: Individually packed units for field installation.• Abbreviations: H.O. (hub opening), C.P. (closing plate).

ACCESSORIES

Page 61: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

61ACCESSORIES

AccessoriesConnector Kits, Closing Kits & Generator Interlock

Connector Kits — For Use with 3⁄8"-16 Stud Type Units Only

Closing Covers

Single Twin

Suffix Part # (3 per set) - 1Ø Suffix Part # (3 per set) - 1Ø

K1 K1539 6-350 K2 K1350 6-350

K3 K1540 4-600 or (2) 1/0-250* K2L K1350L 6-350 (non rotating)

K3L K1540L4-600 or (2) 1/0-250*

(non rotating) K4 K1541 4-600

Suffix Part # (4 per set) - 3Ø Suffix Part # (4 per set) - 3Ø

K5 K3082 6-350 K6 K3442 6-350

K7 K3441 4-600 or (2) 1/0-250* K8 K3083 4-600

Meter Closing Plate(Ring Type/Ringless)

Metal Closing Plate(For Ringless Sockets)

6003 - Grey Plastic CP-21

6116 - Clear Plastic

K8180 (sold in pairs)

K5815 - large QN with small frame Q

K5820 - large frame QN with large frame QN

K5830 - small frame Q to small frame Q

Bypass Link

Generator Interlock

A-GPK3235

Suitable for use with pedestals for extra support

S2291-TO

K4802

M5-144

Do not use with lever bypass

sockets

Touch-Up PaintStake KitPedestal Raceway Anti-Inversion Clip

Disconnect Sleeve

Note

Consult factory for proper connector kits for studded meter sockets.

*For (2) 1/0-250, conductors must be of same size.

PED

Grade Line

10”

24”

54”

18”

Page 62: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

62ACCESORIES

AccessoriesFifth Terminals, Tap Connectors & Block Assemblies

K1190 (For factory installed triplex ground, add suffix -TG to catalog number)

Fifth Terminals

Tap Connectors (3 per set)

100 Amp Blocks (single sockets only) 200 Amp Blocks (single sockets only)

5T8K2 - 100-200 Amp“Plug-In”

K5T - 200 Amp (Block with Square Hole)

K3865 - Heavy Duty Jaw Clamping (K3866 without Neutral Wire)

Replaces the load or line side slide-in nut assembly on Milbank 200 amp sockets. Allows for a 100 amp tap location in addition to the #6-350 kcmil load-side connector. K5022 includes safety barrier extensions for applications over 300 VAC. Three lugs per kit.

K4977-INT - Internal Hex

K4977-EXT - External Hex

K5022-INT - Internal Hex (set of 4 w/ barrier)

BL7474 - Block Assembly

BL7499 - Horn Bypass Block Assembly

Z904486-AO - Slotted Nut Assembly

Z903274-AO - Horn Bypass Nut Assembly

Z802965-AC - Neutral without Nut

Z901925-AC - Hex Nut Set Screw

K4527 - Internal Hex Block Assembly (w/ meter support)

K4528 - External Hex Block Assembly (w/ meter support)

K4529 - Internal Hex Horn Bypass Block Assembly (w/ meter support)

K4530 - External Hex Horn Bypass Block Assembly (w/ meter support)

Z916265-AO - Internal Nut Assembly

Z916264-AO - External Nut Assembly

Z814898-AC - Neutral without Nut

Triplex Ground

Page 63: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

63COMMERCIAL& INDUSTRIALENCLOSURES

Commercial & Industrial Enclosures

NEMA Commercial Enclosures

Milbank’s line of commercial enclosures includes the full gamut of styles and sizes; everything from junction boxes to transformer cabinets, telephone cabinets to wireway.

Type 1 EnclosuresMilbank’s Type 1 enclosures are designed for indoor use to provide a degree of protection to personnel against access to hazardous parts and to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects, such as falling dirt.

Type 3R EnclosuresMilbank’s Type 3R enclosures are designed for either indoor or outdoor use to provide a degree of protection from harmful effects on the equipment due to the ingress of water (rain, sleet, snow) and that will be undamaged by the external formation of ice on the enclosure.

WirewayMilbank’s wide range of wireway is available in many styles and sizes and its wide range of fittings allows it to smoothly transition to and from competitors’ products.

NEMA Industrial Enclosures

Milbank’s line of industrial enclosures include junction boxes, wiring trough, push-button enclosures and modular enclosures. Milbank also excels in special designs; nearly any type, size or color of enclosure you need, we can make!

Type 12 EnclosuresEnclosures constructed without knockouts for indoor use to provide a degree of protection to personnel against access to hazardous parts, and protect components against falling dirt, circulating dust and lint, and dripping or splashing water.

Type 4 EnclosuresEnclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; protect equipment against falling dirt and windblown dust; protect against rain, sleet, snow, splashing water, and hose directed water; and is resistant to damage by the external formation of ice on the enclosure.

Industrial Enclosure SpecialsMilbank specializes in custom enclosure projects, offering an almost limitless amount of styles, options, colors and sizes. Milbank will meet your needs and specifications and deliver a custom enclosure that protects your crucial electric equipment.

Thermal ManagementProtect components housed in enclosures from damage caused by overheating, freezing, humidity and condensation with these thermal management products.

Page 64: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

64WATTHOUR

METER FORMS

Watthour Meter FormsStandard Forms | Transformer Rated or Self-Contained

SC SC TR TR TR

TR SC SC SC SC

TR TR SC SC TR

TR TR SC SC TR

TR TR TR

2 and 3-WIRE FORMS1S & 2S

2 and 3-WIRE FORMS1S & 2S with BYPASS

2-WIRE FORM 3S5th Term. 9 o’clock

2-WIRE FORM 3Swith BYPASS

2-WIRE FORM 3S5th Term. 6 o’clock

2-WIRE FORM 3Swith BYPASS

2 ELEMENT3-WIRE NETWORK

FORM 12S 5thTERM. 9 o’clock

2 ELEMENT 3-WIRENETWORK FORM 12S

with BYPASS5th Term. 9 o’clock

2 ELEMENT 3-WIRENETWORK FORM 12S

with BYPASS5th Term. 6 o’clock

2 ELEMENT3-WIRE NETWORK

FORM 12S 5thTERM. 6 o’clock

3-WIRE FORM 4S 3-WIRE FORM 4SWITH BYPASS

2 or 3 ELEMENT3Ø4W Y or

Y FORM 14SFORM 15S

Y FORM 16S

2 or 3 ELEMENT3Ø4W Y or

FORMS 14S & 15Swith BYPASS

2 ELEMENT3Ø4W Y orY FORM 7SFORM 24S

with BYPASS

2 ELEMENT2Ø3W, 2Ø4W, 3Ø3W

FORM 5S

2 ELEMENT Ø3W,2Ø4W, 3Ø3W FORM 5S with

BYPASS

2 ELEMENT2Ø3W, 2Ø4W, 3Ø3W

FORM 13S

2 or 3 ELEMENT2Ø3W, 2Ø4W, 3Ø3W

FORM 13S withBYPASS

2 or 3 ELEMENT3Ø4W Y orY FORM 9SFORM 8S

2 or 3 ELEMENT3Ø4W Y or

FORMS 8S & 9SFORMS 8S & 9S

with BYPASS

2 ELEMENT3Ø4W YFORM 6S

2 ELEMENT3Ø4W YFORM 6S

with BYPASS

TR = TRANSFORMER RATEDSC = SELF CONTAINED

Page 65: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

65METERFORMS

Meter FormsReference Information

++

ILINE (BONDED)N

C.T.LOAD

2 ++

DIAGRAM D

P1 P2 C+1 C2C+

2PN C1

C.T.

DIAGRAM D1∅3W or 3W Network with 2 C.T.’s

2 Stator Meter - Form 5S8T Socket, Test Switch #TS07-0105

++

1LINE

C.T.LOAD2

P1 C+1

++

3

++

PT PT

DIAGRAM E

P3 P2 C1 C+3 C3

C.T.

DIAGRAM E3∅3W “∆” with 2 P.T.’s & 2 C.T.’s

2 Stator Meter - Form 5S8T Socket, Test Switch #TS07-0105

++

1LINE

C.T.LOAD2

P1 C+1

++

3

DIAGRAM F

P3 P2 C1 C+3 C3

C.T.

DIAGRAM F3∅3W “∆” with 2 C.T.’s2 Stator Meter - Form 5S

8T Socket, Test Switch #TS07-0105

+

+

C.T.LOAD

P1

+

+

P3 PN C+ C+

C.T.

C.T.

++

(BONDED)

DIAGRAM G

C C C+ C

1

LINE23N

DIAGRAM G3∅4W “Y” with 3 C.T.’s

2 1⁄2 Stator Meter - Form 6S13T Socket, Test Switch #TS10-0109

+

+

1

LINE

C.T.LOAD2

P1

+

+3

P3 PN C+

N

C.T.

C.T.

++

(BONDED)

+ +

PTPT

+ +

DIAGRAM H

C C+C+ CC

DIAGRAM H3∅4W “Y” with 2 P.T.’s & 3 C.T.’s

2 1⁄2 Stator Meter - Form 6S13T Socket, Test Switch #TS10-0109

+

+

1

LINE

C.T.LOAD2

P1

+

+3

P3 PN C+

N

C.T.

C.T.

++

(BONDED)

P2

DIAGRAM I

C C+ C C+ C

DIAGRAM I3∅4W “Y” or “∆” with 3 C.T.’s“Y” 3 Stator Meter - Form 9S“∆” 2 Stator Meter - Form 8S

13T Socket, Test Switch #TS10-0109

+

+

1

LINE

C.T.LOAD2

P1

+

+3

PN C+

N

C.T.

C.T.

+

+

(BONDED)

+ +PT PT

++

P3

PT

+ +

DIAGRAM J

P2 C C+ C C+ C

DIAGRAM J3∅4W “Y” with 3 P.T.’s & 3 C.T.’s

3 Stator Meter - Form 9S13T Socket, Test Switch #TS10-0109

DIAGRAM A

(ALT.LOC.)

++

+

+

ILINE

(BONDED)N C.T. LOAD

P1 PN C+1 C1

P.T.

DIAGRAM A1∅2W with 1 P.T. & 1 C.T.

Single Stator Meter(2W1∅) - Form 3S5T Socket, Test Switch #TS04-0101

(ALT.LOC.)

++I

LINE

(BONDED)N C.T.

LOAD2

DIAGRAM B

P1 PN C+1 C1

DIAGRAM B1∅3W with 1 C.T.

Single Stator Meter (2W1∅) - Form 3S5T Socket, Test Switch #TS04-0101

++

ILINE (BONDED)N

C.T.LOAD

2

P1 P2 C+1 C+

2 C2C+2

++

DIAGRAM C

C.T.

DIAGRAM C1∅3W with 2 C.T.’s

Single Stator Meter (3W1∅) - Form 4S6T Socket, Test Switch #TS07-0105

Prewiring: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram.

Page 66: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

66

This table is for concentric stranded conductors only. For cables with compact conductors refer to NEC. Refer to latest NEC Code or Local Codes for updated requirements.

TypeConductor Size

(AWG/kcmil)Conduit Trade Sizes (Inches)

1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4

THHN,THWN,THWN-2

12 9 16 26 46 62 102 146 225 301 387

10 6 10 17 29 39 64 92 142 189 244

8 3 6 9 16 22 37 53 82 109 140

6 2 4 4 12 16 27 38 59 79 101

4 1 2 4 7 10 16 23 36 48 62

3 1 1 3 6 8 14 20 31 41 53

2 1 1 3 5 7 11 19 26 34 44

1 1 1 1 4 5 8 12 19 25 35

1/0 1 1 1 3 4 7 10 16 21 27

2/0 0 1 1 2 3 6 8 13 18 23

3/0 0 1 1 1 3 5 7 11 15 19

4/0 0 1 1 1 2 4 6 9 12 16

XHH,XHHW,XHHW-2

4 1 2 4 7 10 16 24 37 49 63

2 1 1 3 5 7 12 17 26 35 45

1/0 1 1 1 3 4 7 10 16 22 28

2/0 0 1 1 2 3 6 9 13 18 23

4/0 0 1 1 1 2 4 6 9 12 16

250 0 0 1 1 1 3 5 7 10 13

350 0 0 1 1 1 2 3 6 7 10

500 0 0 0 1 1 1 2 4 5 7

750 0 0 0 0 1 1 1 3 4 5

MAXIMUM NUMBER OF CONDUCTORS IN CONDUITTable from 2008 NEC Code Reference: Rigid Metal Conduit

Conduit, Ampacity & SCCRReference Information

CONDUIT, AMPACITY &

SCCR

CATALOG NUMBERS U5952 & U5953100A MAXIMUM, 120/240 VAC SINGLE PHASE, THREE WIRE

RAINPROOF NEMA TYPE 3R

SHORT CIRCUIT CURRENT RATING IS 10,000 RMS SYMMETRICAL AMPERE AT 240 VACMAXIMUM, BUT IS LIMITED TO THE LOWEST SHORT CIRCUIT CURRENT RATING OF ANYINSTALLED CIRCUIT BREAKER. WATTHOUR METER NOT INCLUDED IN SHORT CIRCUITCURRENT RATING. REPLACEMENT CIRCUIT BREAKER MUST BE THE SAME TYPE AND

RATING. USE SIEMENS QP, QT; CUTLER-HAMMER QP, BD, BR;SQUARE D HOMELINE; G.E. TQ, THQ, THQL.

SUITABLE FOR USE ASRECREATIONAL VEHICLE SITE

SUPPLY EQUIPMENT

UNDERGROUND FEED ONLY

ONTRIPOFF

TO RESETBREAKER MOVE TO

“OFF” THEN TO “ON”

DANGERHAZARD OF ELECTRICAL

SHOCK OR BURN

TURN OFF POWER

SUPPLYING THIS EQUIPMENTBEFORE WORKING INSIDE

SIZE OF FIELD INSTALLEDCONDUCTORS SHALL BE

60° OR 75°C SIZED TO 60°CRATING FOR 110 AMPS ORLESS AND 75°C SIZED TO75°C FOR 125 AMPS AND

ABOVE

SHIPPING TENDS TO LOOSEN BOLTED

CONNECTIONS. CHECKAND TIGHTEN ALL

HARDWARE BEFORE ENERGIZING UNIT

LINE LINE

GROUNDLOADNEUTRAL

LINENEUTRAL

WIRE TERMINAL INFORMATION USE AL-CU CONDUCTORS

TERMINAL WIRE RANGE TORQUE LB-IN

LINE AND LINE NEUTRAL 350 KCMIL - #6

2/0 AWG -#14 AWGGROUND CONNECTOR

LOAD NEUTRAL (LARGESLOTTED HEAD HOLE)

LOAD NEUTRAL (SMALLSLOTTED HEAD HOLE)

250

120

35404550

202535

14 - 108

6 - 43 - 1/0

14 - 1086

SAMPLE RATING LABEL

Page 67: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

67ENERGIZATIONOF ELECTRICAL

EQUIPMENT

Energization of Electrical EquipmentImportant Information for Installers

Before EnergizingA. Give equipment a thorough visual examination to determine that: 1) No shipping or installation damage exists. 2) Proper clearances have been maintained. 3) All connections have been made. 4) Equipment is clean and dry.B. Make a thorough examination to: 1) Verify tightness of all bolted connections (see table below). 2) Manually operate all circuit breakers, switches, relays, etc. 3) Check rigidity of all mountings, bus bars and components. 4) Use test equipment to check continuity of circuitry and integrity of insulation.C. All switches and circuit breakers should be in the “off” position.D. Verify that manual meter bypass (if applicable) is in non-bypass position.E. Install cover and/or close doors.F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These steps will secure the installation in case of accidental energization.

When EnergizingA. Use caution and follow established safety procedures: 1) Wear safety apparel. 2) Use safety equipment. 3) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it.

After EnergizingA. Secure the installation: 1) To prevent accidental contact with energized parts, cover all openings with approved filler devices. 2) To prevent unauthorized access, secure all covers and/or doors with approved security devices. 3) Attach/post information to advise others of potential hazards associated with the installation.

Important NoteIn addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment.

*Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first.CU: CopperAL: Aluminum

Nominal Size

Joint DescriptionHead Type

Torque(Inch Lbs.)Screw Nut

10 Brass Brass Nut or Extruded Hole All 20-25 inch lbs.

10 Steel Copper or Aluminum Busbar ≤ 1/8" All 25-30 inch lbs.

10 Steel Steel Nut or Extruded Hole; CU or AL Busbar > 1/8" All 30-35 inch lbs.

12 Steel Aluminum Extruded Hole All 30-35 inch lbs.

12 Steel Steel Nut or Extruded Hole All 40-50 inch lbs.

1/4 Steel Aluminum Extruded Hole All 40-50 inch lbs.

1/4 Steel Steel Nut or Extruded Hole; CU or AL Busbar All 50-60 inch lbs.

5/16 Steel Aluminum Extruded Hole Hex 60-70 inch lbs.

5/16 Steel Steel Nut or Extruded Hole; CU or AL Busbar Hex 100-150 inch lbs.

3/8 Steel Steel Nut Hex 150-200 inch lbs.

1/2 Steel Steel Nut Hex 200-250 inch lbs.

Recommended Torque for General Applications*

Page 68: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

68MATERIALS& FINISHES

Materials & FinishesReference Information

Materials

Finish

Ratings & Compliance

The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute.

Steel Quality

16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. (AISI G90)14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.

Steel Sheet

Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire.Bus Bar: Alloy; 6101-O & 6063-O

Aluminum Extrusion

3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064–.125

Aluminum Sheet

Electrolytic copper with tin plating in most applications.

Copper Sheet & Bus

• In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds.

• Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds.

• Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers.

Insulating Materials

Light gray state-of-the-art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory.

Process

Zinc-coated with a chromate dip.

Metal Fastners

All Milbank electrical enclosures in this catalog are rated “Type 3R Enclosure” unless specified otherwise on the product’s page. All enclosures with a UL designation are constructed per the appropriate UL Standard and may be installed per the National Electric Code. UL procedure files associated with the UL Standards are listed as follows: Meter Sockets (UL 414, File E30202), Test Switches (UL 414, File E62531), Power Outlets (UL 231, File E90945), Panelboards (UL 67, File E32628) and Pullout Switches (UL 1429, File E133062). Additional standards are utilized as applicable: Meter Sockets (ANSI C12.7), Test Switches (ANSI C12.9) and Panelboards (NEMA PB-1).

Ratings & Compliance

Page 69: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

69Utility Approvals Chart

CatalogNumber

AlliantEnergy

WeEnergies

Wisconsin Public Service

Madison Gasand Electric

PageNumber

L572-XL-KK X X X X 19L573-XL-KK X X X X 19L574-XL-KK X X X X 19L575-XL-KK X X X X 19L576-XL-KK X X X X 19

NU8980-O-200-KK X X X 34NU8980-O-200-KK-LP X X X 34

NU8980-O-KK X X X 34NU8980-O-KK-LP X X X 34

NU8980-O-SF100-KK X X X 34NU8980-O-SF100-KK-LP X X X 34

S9995-B-XL X X 42S9996-B-XL X X 42S9997-B-XL X X 42

SDRCW X X X 42SDRCW X X X 42

U1211-RXL X X X 10U1252-X-KK X X X X 22

U1252-X-KK-K1-PED X X X 22U1253-X-KK X X X X 22

U1253-X-KK-K3-PED X X X 22U1254-X-KK X X X X 22

U1254-X-KK-K3-PED X X X 22U1255-X-KK-K4-PED X X X 22

U1256-X-KK-PED X X X 22U1748-O-5T9-WI X 41

U1748-O-WI X X X X 41U1773-XL-TG-KK X X X X 8

U1779-RRL-5T9-K3 OH only X 13U1779-RRL-K3 X 13U1783-O-KK X X X X 31U2120-X-K7 X 14U2594-X-K7 X 14

U2692-XL-KK X X X 21U2732-XT-PED X X Call for approval 25U2733-XT-PED X X Call for approval 25U2734-XT-PED X X Call for approval 25U2735-XT-PED X X Call for approval 25U2736-XT-PED X X Call for approval 25

U2872-XT X X Call for approval 24U2872-XT-5T9-K3 X Call for approval 24

U2872-XT-K3 X Call for approval 24U2873-XT X X Call for approval 24

U2873-XT-K3 X Call for approval 24U2874-XT X X Call for approval 24

U2874-XT-K3 X Call for approval 24U3000-O-5T9-K3L-K2L X 13

U3000-O-K3L X 13U3000-O-K3L-K2L X 13

U3358-O-KK X X X X 31

UTILITYAPPROVALS

CHART

Page 70: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

70 Utility Approvals Chart

CatalogNumber

AlliantEnergy

WeEnergies

Wisconsin Public Service

Madison Gasand Electric

PageNumber

U3849-O-2/150 X X 39U3849-O-2/200 X X X 39

U3849-O-200/100 X X 39U3850-O-TG-KK X 9

U4322-O-5T9 Call for approval Call for approval 38U4323-O-5T9 Call for approval 38

U4329-O X X X 41U4363-X-QG X X OH approved only 13

U4664-X-8502 X 43U4664-X-8507 X 43U4664-XT-9507 X 43U4667-X-8013 X 44U4667-X-8512 X 44U4667-XT-9504 X 44U4667-XT-9506 X 44

U4701-XL X X 12U4724-O X 33

U4724-O-5T9 X X 33U4801-XL X 10

U4801-XL-5T9 X 10U5136-O-100S X X X X 36U5136-O-150S X X X X 36U5136-O-200S X X X X 36U5137-O-100S X X X X 36U5137-O-150S X X X X 36U5137-O-200S X X X X 36

U5168-XTL-100-KK X X X X 16U5168-XTL-200-KK X X X X 16

U5701-0-100S X 38U5701-0-150S X 38U5701-0-200S X 38

U5706-O-200S-KK X 37U5767-X-200-TF X 17U5787-O-200-TF X 17U5842-RL-100-KK X X X 15U5842-RL-200-KK X X X 15

U5844-PXL-200-KK Call for approval 15U5882-X-KK-K1 X X 27

U5882-X-KK-K1-PED X X X 27U5883-X-KK-K1 X X 27

U5883-X-KK-K1-PED X X X 27U5884-X-KK-K1 X X 27

U5884-X-KK-K1-PED X X X 27U5885-X-KK-K1 X X 27

U5885-X-KK-K1-PED X X X 27U5886-X-KK-K1 X X 27

U5886-X-KK-K1-PED X X X 27U5902-X-KK-K1 X X 27

U5902-X-KK-K1-PED X X X 27U5903-X-KK-K1 X X 27

UTILITYAPPROVALS

CHART

Page 71: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

71Utility Approvals ChartUTILITY

APPROVALSCHART

CatalogNumber

AlliantEnergy

WeEnergies

Wisconsin Public Service

Madison Gasand Electric

PageNumber

U5903-X-KK-K1-PED X X X 27U5904-X-KK-K1 X X 27

U5904-X-KK-K1-PED X X X 27U5905-X-KK-K1 X X 27

U5905-X-KK-K1-PED X X X 27U5906-X-KK-K1 X X 27

U5906-X-KK-K1-PED X X X 27U5925-O-100-KK X 35U5925-O-150-KK X 35U5925-O-200-KK X 35

U7362-RL-KK X X X X 20U7363-RL-KK X X X X 20U7364-RL-KK X X X X 20U7365-RL-KK X X X X 20U7366-RL-KK X X X X 20U7375-RL-KK X X 15

U7421-RL X X 12U7423-XL X X 12

U7487-RL-TG-KK X X X 7U7573-RL X X 8

U8032-XL-KK X X X X 18U8033-XL-KK X X X X 18U8034-XL-KK X X X X 18U8035-XL-KK X X X X 18U8036-XL-KK X X X X 18U8624-RXL X X 11U9107-O X X 32

U9107-O-WI X XU9108-O X X X 32

U9320-RXL X X 8U9550-DL X X X 11U9551-O X X X 11

U9700-RRL X X X 12U9701-RXL X X X X 12UC1962-XL X X X 29UC2427-XL X X 30UC2428-XL X X 30UC3887-XL X X X 29UC3889-XL X X X 29UC7448-XL X X X X 29UC7449-XL X X X 29UC7532-XL X X X 29

WS X X X 42

Page 72: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

72

6003.................................... 616116.................................... 61 U5268-XTL-100-KK ............ 165T8K2 ................................. 62A7514 ................................. 60A7515 ................................. 60A7516 ................................. 60A7517 ................................. 60A7518 ................................. 60A7551 ................................. 60A8110 ................................. 60A8111 ................................. 60A8112 ................................. 60A9064 ................................. 60A-GP ................................... 61BL7474 ............................... 62BL7499 ............................... 62CP-21 .................................. 61K1350 ................................. 61K1350L ............................... 61K1539 ................................. 61K1540 ................................. 61K1540L ............................... 61K1541 ................................. 61K1990 ................................. 62K3082 ................................. 61K3083 ................................. 61K3235 ................................. 61K3441 ................................. 61K3442 ................................. 61K3865 ................................. 62K3866 ................................. 62K4527 ................................. 62K4528 ................................. 62K4529 ................................. 62K4530 ................................. 62K4802 ................................. 61K4977-EXT .......................... 62K4977-INT .......................... 62K5022-INT .......................... 62K5815 ................................. 61K5820 ................................. 61K5830 ................................. 61K5T ..................................... 62K8180 ................................. 61L572-XL-KK ......................... 19L573-XL-KK ......................... 19L574-XL-KK ......................... 19

L575-XL-KK ......................... 19L576-XL-KK ......................... 19M5-144 ............................... 61NU8980-O-200-KK ............. 34NU8980-O-200-KK-LP ........ 34NU8980-O-KK .................... 34NU8980-O-KK-LP ............... 34NU8980-O-SF100-KK ......... 34NU8980-O-SF100-KK-LP .... 34Q115................................... 59Q115H ................................ 59Q120................................... 59Q120H ................................ 59Q125................................... 59Q125H ................................ 59Q130................................... 59Q130H ................................ 59Q135................................... 59Q135H ................................ 59Q140................................... 59Q140H ................................ 59Q150................................... 59Q150H ................................ 59Q160................................... 59Q160H ................................ 59Q170................................... 59Q170H ................................ 59Q2100................................. 59Q2100H .............................. 59Q2125................................. 59Q2125H .............................. 59Q215................................... 59Q215H ................................ 59Q220................................... 59Q220H ................................ 59Q225................................... 59Q225H ................................ 59Q230................................... 59Q230H ................................ 59Q235................................... 59Q235H ................................ 59Q240................................... 59Q240H ................................ 59Q250................................... 59Q250H ................................ 59Q260................................... 59Q260H ................................ 59Q270................................... 59

Q270H ................................ 59Q280................................... 59Q280H ................................ 59Q290................................... 59Q290H ................................ 59QN2150 .............................. 59QN2150H ........................... 59QN2150R ............................ 59QN2150RH ......................... 59QN2200 .............................. 59QN2200H ........................... 59QN2200R ............................ 59QN2200RH ......................... 59S2291-TO ........................... 61S8324.................................. 60S9995-B-XL ......................... 43S9996-B-XL ......................... 43S9997-B-XL ......................... 43U1211-RXL .......................... 10U1252-X-KK ........................ 22U1252-X-KK-K1-PED .......... 22U1253-X-KK ........................ 22U1253-X-KK-K3-PED .......... 22U1254-X-KK ........................ 22U1254-X-KK-K3-PED .......... 22U1255-X-KK-K4-PED .......... 22U1256-X-KK-PED ................ 22U1748-O-5T9-WI ................ 41U1748-O-WI ....................... 41U1773-XL-TG-KK .................. 8U1779-RRL-5T9-K3 ............. 13U1779-RRL-K3 .................... 13U1783-O-KK ....................... 31U2120-X-K7 ........................ 14U2594-X-K7 ........................ 14U2692-XL-KK ...................... 21U2732-XT-PED .................... 25U2732-XT-PED-K7 .............. 25U2733-XT-PED .................... 25U2733-XT-PED-K7 .............. 25U2734-XT-PED .................... 25U2734-XT-PED-K7 .............. 25U2735-XT-PED .................... 25U2735-XT-PED-K7 .............. 25U2736-XT-PED .................... 25U2736-XT-PED-K7 .............. 25U2872-XT ............................ 24U2872-XT-5T9-K3 ............... 24

U2872-XT-K3 ....................... 24U2873-XT ............................ 24U2873-XT-K3 ....................... 24U2874-XT ............................ 24U2874-XT-K3 ....................... 24U3000-O-5T9-K3L-K2L ....... 13U3000-O-K3L ...................... 13U3000-O-K3L-K2L .............. 13U3358-O-KK ....................... 31U3802 ................................... 4U3812 ................................... 4U3822-20GWR ...................... 5U3832 ................................... 4U3849-O-2/150 .................. 40U3849-O-2/200 .................. 40U3849-O-200-100 .............. 40U3850-O-TG-KK ................... 8U3862 ................................... 4U4322-O-5T9 ...................... 39U4323-O-5T9 ...................... 39U4329-O ............................. 42U4363-X-QG ....................... 13U4664-X-8502 .................... 44U4664-X-8507 .................... 44U4664-XT-9507 ................... 44U4667-X-8013 .................... 45U4667-X-8512 .................... 45U4667-XT-9504 ................... 45U4667-XT-9506 ................... 45U4701-XL ............................ 12U4724-O ............................. 33U4724-O-5T9 ...................... 33U4801-XL ............................ 10U4801-XL-5T9 ..................... 10U4881-O ............................... 6U4881-O-50GB ..................... 6U4881-O-60GB ..................... 6U5136-O-100S .................... 36U5136-O-150S .................... 36U5136-O-200S .................... 36U5137-O-100S .................... 36U5137-O-150S .................... 36U5137-O-200S .................... 36U5168-XTL-100-KK ............. 16U5168-XTL-200-KK ............. 16U5268-XTL-200-KK ............. 16U5701-0-100S ..................... 38U5701-0-150S ..................... 38

IndexINDEX

Page 73: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.

73INDEX

U5701-0-200S ..................... 38U5706-O-200S-KK .............. 37U5767-O-200-CB ................ 17U5767-X-200-CB ................ 17U5767-X-200-TF ................. 17U5787-O-200-TF ................ 17U5842-RL-100-KK ............... 15U5842-RL-200-KK ............... 15U5844-PXL-200-KK ............. 15U5882-X-KK-K1-PED .......... 27U5883-X-KK-K1-PED .......... 27U5884-X-KK-K1-PED .......... 27U5885-X-KK-K1-PED .......... 27U5886-X-KK-K1-PED .......... 27U5902-X-KK-K1-PED .......... 27U5903-X-KK-K1-PED .......... 27U5904-X-KK-K1-PED .......... 27U5905-X-KK-K1-PED .......... 27U5906-X-KK-K1-PED .......... 27U5925-O-100-KK ................ 35U5925-O-150-KK ................ 35U5925-O-200-KK ................ 35U6221-O-100-10GR ............ 35U6221-O-200-10GR ............ 35U7362-RL-KK ...................... 20U7363-RL-KK ...................... 20U7364-RL-KK ...................... 20U7365-RL-KK ...................... 20U7366-RL-KK ...................... 20U7375-RL-KK ...................... 15U7421-RL ............................ 12U7423-XL ............................ 12U7487-RL-TG-KK .................. 7U7573-RL .............................. 9U8032-XL-KK ...................... 18U8033-XL-KK ...................... 18U8034-XL-KK ...................... 18U8035-XL-KK ...................... 18U8036-XL-KK ...................... 18U8624-RXL .......................... 11U9107-O-CECHA ............... 32U9107-O-WI ....................... 32U9108-O-WI ....................... 32U9320-RXL ............................ 9U9550-DL ........................... 11U9551-O ............................. 11U9700-RRL .......................... 12U9701-RXL .......................... 12

UC1290-RL ......................... 29UC1299-RL ......................... 29UC2427-XL ......................... 30UC2428-XL ......................... 30UC3887-XL ......................... 29UC3889-XL ......................... 29UC7448-XL ......................... 29UC7449-XL ......................... 29UC7532-XL ......................... 29UQFB-100 ........................... 58UQFB-100-X1 ..................... 58UQFB-125 ........................... 58UQFB-125-X1 ..................... 58UQFB-150 ........................... 58UQFB-150-X1 ..................... 58UQFB-175 ........................... 58UQFB-175-X1 ..................... 58UQFB-200 ........................... 58UQFB-200-X1 ..................... 58UQFBH-100 ........................ 58UQFBH-125 ........................ 58UQFBH-150 ........................ 58UQFBH-175 ........................ 58UQFBH-200 ........................ 58UQFBH-M-100 .................... 58UQFBH-M-125 .................... 58UQFBH-M-150 .................... 58UQFBH-M-175 .................... 58UQFBH-M-200 .................... 58UQFP-100 ........................... 58UQFP-125 ........................... 58UQFP-150 ........................... 58UQFP-175 ........................... 58UQFP-200 ........................... 58UQFPH-100 ........................ 58UQFPH-125 ........................ 58UQFPH-150 ........................ 58UQFPH-175 ........................ 58UQFPH-200 ........................ 58UQFPH-M-100 .................... 58UQFPH-M-125 .................... 58UQFPH-M-150 .................... 58UQFPH-M-175 .................... 58UQFPH-M-200 .................... 58UQFP-M-100 ...................... 58UQFP-M-125 ...................... 58UQFP-M-150 ...................... 58UQFP-M-175 ...................... 58

UQFP-M-200 ...................... 58Z703916-AC ....................... 47Z703917-AC ....................... 46Z703917-AC ....................... 47Z703918-AC ....................... 46Z703918-AC ....................... 47Z703919-AC ....................... 46Z703919-AC ....................... 47Z703921-AC ....................... 47Z704693-AC ....................... 46Z704693-AC ....................... 47Z704694-AC ....................... 46Z704694-AC ....................... 47Z705420-AC ....................... 46Z705420-AC ....................... 47Z705456-AC ....................... 46Z705456-AC ....................... 47Z708145-AC ....................... 47Z802965-AC ....................... 62Z844898-AC ....................... 62Z901925-AC ....................... 62Z903274-AO ....................... 62Z904486-AO ....................... 62Z916264-AO ....................... 62Z916265-AO ....................... 62

Index

Page 74: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American
Page 75: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American
Page 76: Wisconsin - Milbankdesign and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com WISCONSIN 7/18