wisconsin - milbankdesign and manufacturing, milbank’s portfolio includes metering equipment,...
TRANSCRIPT
WisconsinArea Catalog
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
2
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
MILBANKOVERVIEW
Milbank OverviewEnergy At Work since 1927
Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial, industrial, utility and transportation sectors. With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American manufacturer headquartered in Kansas City, Mo. For more information, please visit milbankworks.com.
As a market leader in electrical metering equipment, Milbank has set the standard for quality since 1927. Hundreds of configurations are available, including many sizes, knockout configurations, terminal configurations, bypass options, hubs, locks and connectors. Milbank has the socket you need with thousands of active products to meet your utility’s requirements.
Milbank doesn’t just build empty enclosures. We can deliver the entire package, complete with custom control equipment built to your exact specifications by our engineers. Milbank commercial pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures. Milbank’s manual and automatic transfer switches are durable, easy to install and compatible with most generators.
Milbank’s line of enclosures include commercial junction boxes, panel mount enclosures, transformer cabinets, wireway, trough and industrial panel mount and push-button enclosures. Built with high-quality craftsmanship and materials which meet or exceed industry standards, Milbank enclosures are made to protect controls and equipment from dust, dirt and other harmful elements found in a wide variety of environments.
METERING
ENCLOSED CONTROLS
ENCLOSURES
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
3TABLE OFCONTENTS
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Table of ContentsAir Conditioner Disconnects30-60 amp AC disconnects .......................................................................................................................................... 4–5Hot tub disconnects .......................................................................................................................................................... 6
Single Position Sockets125 amps, 4 terminals, ringless ......................................................................................................................................... 7200 amps, 4 terminals, ringless ......................................................................................................................................... 8125 amps, 7 terminals, lever bypass, ringless ................................................................................................................... 9200 amps, 4, 5 & 7 terminals, lever bypass, ringless ................................................................................................ 10–12320 amps, 4, 5 & 7 terminals, lever bypass, ringless ................................................................................................ 13–14
Meter Mains100–200 amps, 4 terminals, ringless ............................................................................................................................... 15200 amps, 4 terminals, with load center, ringless ........................................................................................................... 16200 amps, cold sequence meter mains ........................................................................................................................... 17
Multi-Position100–200 amps, 4 terminals, ringless ......................................................................................................................... 18–23200 amps, 5 & 7 terminals, lever bypass, ringless .................................................................................................... 24–26125 & 200 amps, 4 terminals, meter mains, ringless ................................................................................................. 27–28
Transformer Rated Sockets20 amps, 5–13 terminals, ringless ................................................................................................................................... 29Two-position, 20 amps, 8–13 terminals, ring type .......................................................................................................... 30
Pedestals200 amps, 4 terminals, ringless ....................................................................................................................................... 31100–200 amps, 4, 5 & 7 terminals, ringless .............................................................................................................. 32–33100–200 amps, 4 terminals, meter main, ringless ........................................................................................................... 34100–200 amps, 4 terminals, meter main with load center, ringless .......................................................................... 35–37100–200 amps, 5 terminals, meter main with load center, lever bypass, ringless ..................................................... 38-39320 amps, 4 & 5 terminals, meter main with load center, lever bypass, ringless ....................................................... 40-41
MiscellaneousJoint Use Termination Cabinet ....................................................................................................................................... 42Polyphase enclosures for A base meters ........................................................................................................................ 43Type K4 & K7 meter sockets .................................................................................................................................... 44–46Lugs for K-Series ............................................................................................................................................................. 47Commercial Pedestals ................................................................................................................................................ 48-49Circuit Breakers ......................................................................................................................................................... 50-57Accessories ............................................................................................................................................................... 60–62Commerical & Industrial Enclosures ................................................................................................................................ 63Reference Information .............................................................................................................................................. 64–68Utility Approvals Chart ............................................................................................................................................. 69–71Index ......................................................................................................................................................................... 72–73
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
4AC
DISCONNECTS
Air Conditioner Disconnects30-60 Amps | Fusible & Non-Fusible
Milbank’s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements in the NEC, and also complies with Article 440-14 in the NEC. To ensure the safest conditions, we designed our disconnect pullouts to be removable so they may be reinstalled in the off position. Another safety feature is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading finish.
Catalog Number
Amps TypeMax H.P.
Weight(lbs.)
Line/Load Wire Range Ground Wire
Range CU/ALDimensions Wire Rating
CU AL D" W" H" CU °C AL °C
U3802 60 Non-Fusible 10 3.25 #14-#2 #12-#2 #14-4 21⁄2 5 71⁄2 60°/75° 60°/75°
U3812 60 Non-Auto 10 3.25 #14-#2 #12-#2 #14-4 21⁄2 5 71⁄2 60°/75° 60°/75°
U3832 30 Fusible 3 2.5 #14-#3 #14-#3 #14-3 21⁄8 5 7 60°/75° 60°/75°
U3862 60 Fusible 10 3.3 #14-#3 #14-#3 #14-3 21⁄8 5 9 60°/75° 60°/75°
30–60 Amps | 1Ø 240 VAC | Air Conditioner Disconnects
Notes
• UL listed as Enclosed Pullout Switch• Type 3R rain-resistant• One-inch concentric knockouts
U3832U3812U3802
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
5Air Conditioner Disconnects60 Amps | With 20 Amp GFCI Receptacle
ACDISCONNECTS
CatalogNumber
TypeMax H.P.
Weight(lbs.)
Line/Load Wire Range
Ground Wire Range
CU/AL
Dimensions Wire Rating
CU AL D" W" H" CU °C AL °C
U3822-20GWR Non-Fusible 10 6 #14-#2 #12-#2 #14-4 44⁄5 51⁄4 72⁄5 60°/75° 60°/75°
60 Amps | 1Ø, 240 VAC | Air Conditioner Disconnect with GFCI Receptacle
Notes
• Disconnect Pullouts: To ensure the safest conditions, Milbank disconnect pullouts are reversible so they may be reinstalled in the OFF position.• Padlock Provision: All units are designed with a padlock provision on the cover for security.• *In-Use Cover: Cover is rated as an in-use cover (cover may be closed with cords plugged into receptacle).
• Meets NEC #210.63 requirements• UL listed as Power Outlet• Type 3R enclosure• In-use cover*• Duplex ground connector• 1" concentric knockouts
• 1Ø, 240 volt• 60 amp, non-fused• 20 amp GFCI receptacle• Reset/test button• Weather and tamper resistant• Meets NEC #406.8 requirements
Specifications
U3822-20GWR
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
6HOT TUB
DISCONNECTS
Hot Tub DisconnectsType 3R Enclosures
U4881-O-50GB U4881-O-60GB
Catalog Number
Breaker Amps
TypeWeight(lbs.)
Line/LoadWire Range
Ground Wire Range
CU/AL
Dimensions
CU AL D" W" H"
U4881-O — Breaker Provision 7 #14-1/0 #14-1/0 #14-1/0 33⁄4 71⁄2 81⁄2
U4881-O-50GB 50 Breaker 8 #14-1/0 #14-1/0 #14-1/0 33⁄4 71⁄2 81⁄2
U4881-O-60GB 60 Breaker 8 #14-1/0 #14-1/0 #14-1/0 33⁄4 71⁄2 81⁄2
100 Amps | Hot Tub Disconnect or Sub Panel Breaker Enclosure | Type 3R
Specifications
• 240 volt ground fault protection• UL listed, Type 3R rain-resistant• 2-pole, 50 or 60 amp GFCI breaker protection• Compact size• Three or four wire installation
• 1Ø, 120/240 VAC• Standard package of 12• Two extra one-pole breaker spaces• 100 amp overall rating• Easy to install
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
7
1
2 2
4
33
Single Position Sockets125 Amps | 4 Terminals | Ringless | 600 VAC
Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Bypass: The horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.• Connectors: Extruded aluminum connectors are tin plated. Unit is supplied with a triplex neutral.• Fifth Terminal: For field-installed fifth terminal, order catalog number 5T8K2 (must be bolted in).
7487
CatalogNumber
Terminals Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4
U7487-RL-TG-KK 4 OH H.O. #6-2/0 #6-2/0 Horn 35⁄16 8 111⁄2 2 11⁄2 11⁄4 1⁄4
125 Amps | 4 Terminals | Ringless | Single Position
U7487-RL-TG-KK
125 AMPSINGLE
POSITIONSOCKETS
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
8
1
1 1 1
2 3
1
200 AMPSINGLE
POSITIONSOCKETS
Single Position Sockets200 Amps | 4 Terminals | Ringless | 600 VAC
1773
Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Bypass: The horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.• Connectors: Units are supplied with extruded aluminum connectors and bonded triplex neutral.• Fifth Terminal: For field-installed fifth terminal, order catalog number K5T to fit into square opening in the 9 o’clock position.
CatalogNumber
Terminals Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4
U1773-XL-TG-KK 4 OH C.P. #6-350 #6-350 Horn 41⁄8 11 151⁄2 21⁄2 1⁄4,1⁄2 1⁄4 —
U3850-O-TG-KK 4 UG Blank #6-350 #6-350 Horn 41⁄2 13 151⁄4 3 21⁄2 11⁄2 1⁄4,1⁄2
200 Amps | 4 Terminals | Ringless | Single Position
U1773-XL-TG-KK
1 2
2
3
4
2
3850
U3850-O-TG-KK
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
9
1 1
1
2
23
1 2
34
1 1 1
125 AMPSINGLE
POSITIONSOCKETS
Lever Bypass Single Position Sockets125 Amps | 7 Terminals | Ringless | 600 VAC
7573 9320
Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Bypass: The lever operates bypass only; it does not provide clamping action on meter spades.• Connectors: Units are supplied with extruded aluminum connectors and bonded triplex neutral.
CatalogNumber
Terminals Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4
U7573-RL 7 OH H.O. #6-2/0 #6-2/0 Lever 47⁄8 10 181⁄2 2 3⁄4 1⁄4,1⁄2 —
U9320-RXL 7 OH/UG C.P. #6-2/0 #6-2/0 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4
125 Amps | 7 Terminals | Ringless | Single Position
U7573-RL U9320-RXL
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
10
1 2
34
1 1 1
200 AMPLEVER
BYPASSSOCKETS
Lever Bypass Single Position Sockets200 Amps | 4 & 5 Terminals | Ringless | 600 VAC
U1211-RXL U4801-XL-5T9
12114801
Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Bypass: The lever on the U1211 operates bypass only; it does not provide clamping action on meter spades. The U4801 is a heavy duty lever bypass and the lever supplies clamping action on meter spades.• Connectors: Units are supplied with extruded aluminum connectors and bonded triplex neutral.• Fifth Terminal: For field-installed fifth terminal, order catalog number K3866.• †Factory-Insalled Fifth Terminal: These units include a factory-installed fifth terminal in the 9 o’clock position for use on Alliant Energy lines when a fifth terminal is required.
CatalogNumber
Terminals Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4
U1211-RXL 4 OH C.P. #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4
U4801-XL 4 OH/UG C.P. #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4
U4801-XL-5T9 5† OH/UG C.P. #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4
200 Amps | 4 & 5 Terminals | Ringless | Lever Bypass | Single Position
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
11
1
1
2
3
34 1 1
1
1
2
34
200 AMPLEVER
BYPASSSOCKETS
Lever Bypass Single Position Sockets200 Amps | 5 Terminals | Ringless | 600 VAC
U9550-RL U9551-O U8624-RXL
9550 95518624
Notes
• Grounded B Phase: The U9550 and U9551 have a grounded B phase that can be field-isolated.• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Bypass: The lever operates the bypass device and supplies clamping action on meter spades.• Connectors: Supplied with internal hex connectors. Extruded aluminum connectors are tin plated.
CatalogNumber
Terminals Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4
U9550-DL 5 OH 2" #6-350 #6-350 Lever 47⁄8 10 181⁄2 3 21⁄2 3⁄4 1⁄4,1⁄2
U9551-O 5 UG Blank #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4
200 Amps | 5 Terminals | Ringless | Lever Bypass | Single Position
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
12
1
34
1 1 1
2
200 AMPLEVER BYPASS
SOCKETS
74219700
7423 97014701
U9700-RRLU7423-XLU7421-RL
Lever Bypass Single Position Sockets200 Amp | 7 Terminals | Ringless | 600 VAC
Notes
• †Service: The U7423 and U9701 are overhead only for We Energy.• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• External Hex: The U4701 has external hex bolt in the lugs. • Lever Bypass: The lever in the U7421 and U7423 operates the bypass only and does not provide clamping action on meter spades. The lever in the U9700, U9701, U4701 supplies clamping action and operates bypass device.• Isolated Neutral: For field-installed isolated neutral for U9701, U7423 and U4701, order K1047.• Connectors: Units are supplied with extruded aluminum connectors.
CatalogNumber
Terminals Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4
U7421-RL 7 OH H.O. #6-350 #6-350 Lever 47⁄8 10 181⁄2 3 21⁄2 3⁄4 1⁄4,1⁄2
U9700-RRL 7 OH H.O. #6-350 #6-350 Lever 47⁄8 10 181⁄2 3 21⁄2 3⁄4 1⁄4,1⁄2
U7423-XL 7 OH/UG† C.P. #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4
U9701-RXL 7 OH/UG† C.P. #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4
U4701-XL 7 OH/UG C.P. #6-350 #6-350 Lever 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4
200 Amps | 7 Terminals | Ringless | Lever Bypass | Single Position
1
1
2
3
34
U9701-RXL U4701-XL
1 2
1 1 134
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
13320 AMP
LEVER BYPASSSOCKETS
Lever Bypass Single Position Sockets320 Amp | 4 & 5 Terminals | Ringless | 600 VAC
4363 3000 1779
U4363-X-QG U3000-O-K3L-K2L U1779-RRL-5T9-K3
Notes
• †Factory-Installed Fifth Terminal: Includes factory installed fifth terminal in the 9-o’clock position for use on Alliant Energy lines when a fifth terminal is required.†
• ‡Amperage Rating: These units are rated 300 amp continuous when used on Alliant Energy lines.• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Lever Bypass: The lever supplies clamping action and operates bypass device.• Fifth Terminal: For field-installed fifth terminal, order catalog number K3865.• Isolated Neutral: For field-installed isolated neutral for U3000, order K5978. For the U4363, order K5986• Connectors: Studded products are supplied with 3⁄8”-16 hex head nuts with Belleville washers. For connector lug kits for
the U1779, order as extra K1539L (350 kcmil non-rotating), K1540L (600 kcmil non-rotating) or K1350L (twin 350 kcmil non-rotating). For U3000, order K1350L (350 kcmil non-rotating) or K1540L (600 kcmil non-rotating). For U4363, order K1539 (350 kcmil), K1540 (600 kcmil) or K1350 (twin 350 kcmil). Note that U4363 is UL listed based on parallel 250 conductors only.
CatalogNumber
Terminals Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4
U1779-RRL-K3‡ 4 OH H.O. #4-600 kcmil (1)1/0-250 kcmil (2)
3⁄8"x16 Studs Lever 47⁄8 13 383⁄4 3 21⁄2 1⁄4,1⁄2 1⁄4
U4363-X-QG 4 OH/UG C.P. 3⁄8"x16 Studs 3⁄8"x16 Studs Lever 47⁄8 13 281⁄4 3 1⁄4,1⁄2 1⁄4 —
U3000-O-K3L 4 UG Blank #4-600 kcmil (1)1/0-250 kcmil (2)
3⁄8"x16 Studs Lever 47⁄8 15 30 3 1⁄4,1⁄2 1⁄4 —
U3000-O-K3L-K2L‡ 4 UG Blank #4-600 kcmil (1)1/0-250 kcmil (2) (2) #6-350 Lever 47⁄8 15 30 3 1⁄4,1⁄2 1⁄4 —
U1779-RRL-5T9-K3‡ 5† OH H.O. #4-600 kcmil (1)1/0-250 kcmil (2)
3⁄8"x16 Studs Lever 47⁄8 13 383⁄4 3 21⁄2 1⁄4,1⁄2 1⁄4
U3000-O-5T9-K3L-K2L‡ 5† UG Blank #4-600 kcmil (1)1/0-250 kcmil (2) (2) #6-350 Lever 47⁄8 15 30 3 1⁄4,1⁄2 1⁄4 —
320 Amps | Ringless | Lever Bypass | Single Position
1 1
111
23
1 1
1 1 123
1 1 1
1 2
34
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
14320 AMP
LEVER BYPASSSOCKETS
Lever Bypass Single Position Sockets320 Amps | 7 Terminals | Ringless | 600 VAC
2594 2120
U2594-X U2120-X
2
13
4
1
1
3
4
1
2
1
Catalog Number Terminals Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4
U2594-X-K7 7 OH/UG C.P. #4-600 kcmil (1)1/0-250 kcmil (2)
3⁄8"x16 Studs Lever 61⁄2 19 341⁄8 4 3 1 1⁄4
U2120-X-K7 7 UG C.P. #4-600 kcmil (1)1/0-250 kcmil (2)
3⁄8"x16 Studs Lever 61⁄2 173⁄4 313⁄4 4 3 1 1⁄4
320 Amps† | Ringless | Lever Bypass | Single Position
Notes
• †Amperage Rating: These units are rated 300 amp continuous when used on Alliant Energy lines.• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.• Lever Bypass: The lever supplies clamping action and operates bypass device.• Connectors: Studded products are supplied with 3⁄8”-16 hex head nuts with Belleville washers. For connector lug kits, order
as extra K3082 (350 kcmil), K3441 (600 kcmil) or K3442 (twin 350 kcmil).• Isolated Neutral: For field-installed isolated neutral, order K5977.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
15
1 1
12
100-200 AMPMETERMAINS
Meter Mains100–200 Amps | 4 Terminals | Ringless | 120/240 VAC
U5842-RL-200-KKU7375-RL-KK U5844-PXL-200-KK
1 2
35
3
3
4
4
4
4
2 2 2
584273755844
Catalog Number Service HubConnectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2 3 4 5
U7375-RL-KK OH C.P. #6-2/0 CB 33⁄4 81⁄8 22 11⁄4 1⁄4,1⁄2 — — —
U5842-RL-100-KK* OH H.O. #6-350 CB - 100A 41⁄8 8 30 21⁄2 1⁄4,1⁄2 1⁄4 — —
U5842-RL-200-KK* OH H.O. #6-350 CB - 200A 41⁄8 8 30 21⁄2 1⁄4,1⁄2 1⁄4 — —
U5844-PXL-200-KK* OH/UG C.P. #6-350 CB - 200A 41⁄2 14 30 3 21⁄2 1 1⁄2,3⁄4 1⁄4,1⁄2
100-200 Amp | 4 Terminal | Meter Mains | Horn Bypass | Ringless
*AIC Rating: Models are rated 22K AIC when using Siemens QPH (100 amp) or QNH (200 amp) breakers.• Hub: -PXL versions supplied with one (1) closing plate packed inside. Order other hubs separately.• Fifth Terminal: For field installable fifth terminal kit, order K5T.• Bypass: The horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.
Notes
1 1
1 23
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
16200 AMP
METER MAINW/ LOAD CENTER
Meter Mains with Load Center200 Amps | 4 Terminals | Ringless | 120/240 VAC
1 2
3 3 3
4 56
54
5 51685268
U5168-XTL-200-KK U5268-XTL-200-KK
Catalog Number Service HubConnectors
CU/AL – LineBranchCircuits
Dimensions Knockouts
D" W" H" 1 2 3 4 5 6
U5168-XTL-100-KK OH/UG C.P. #6-350 10 41⁄2 141⁄8 32 3 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2
U5168-XTL-200-KK OH/UG C.P. #6-350 8 41⁄2 141⁄8 32 3 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2
U5268-XTL-100-KK OH/UG C.P. #6-350 20 41⁄2 141⁄8 30 3 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2
U5268-XTL-200-KK OH/UG C.P. #6-350 20 41⁄2 141⁄8 30 3 21⁄2 2 1 1⁄4,1⁄2 1⁄4,1⁄2
200 Amps | 4 Terminals | Meter Mains with Load Center | Horn Bypass | Ringless
• AIC Rating: The U5168 and U5268 are is rated 22K AIC when using Siemens QPH (100 amp) or QNH (200 amp) breakers. • Fifth Terminal: For field installable fifth terminal kit, order K5T.• Bypass: The horn type bypass is factory installed and permits changing and testing of the meter without interrupting
customer service when used with utility-supplied jumpers.
Notes
K5815Large QN with small frame Q
K5820 Large frame QN with large frame
QN
K5830 Small frame Q to
small frame Q
Generator Interlock (compatible with U5168 and U5268)
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
17200 AMP
COLDSEQUENCE
METER MAINS
Cold Sequence Meter Mains200 Amps | 7 Terminals | Ringless
200 Amps | Fuse Pullout Disconnects Ahead Of Meter Socket
Catalog Number Terminals Service HubConnectors CU/AL
BypassDimensions Knockouts
Line & Load D" W" H" 1 2 3 4
U5767-X-200-TF 7 OH/UG C.P. #6-350 Lever 427⁄32 13 43 3 1⁄4,1⁄2 1⁄4 —
U5767-X-200-CB 7 OH/UG C.P. #6-350 Lever 427⁄32 13 43 4 21⁄2 1 1⁄2 , 3⁄4
U5787-O-200-TF 7 UG Blank #6-350 Lever 427⁄32 26 28 4 1⁄2 , 3⁄4 1 1⁄2 , 3⁄4
U5767-O-200-CB 7 UG Blank #6-350 Lever 427⁄32 13 43 4 21⁄2 1 1⁄2 , 3⁄4
U5767-X-200-TF U5787-O-200-TF
5767
1
23 344
2 2 21 1
1 1
5787
Notes
• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.• Fuse pullouts use class T fuses.
1
1 1 123
1
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
18100 AMPMULTI-
POSITIONSOCKETS
Multi-Position Sockets100 Amp | 4 Terminals | Ringless | 300 VAC
1223 3 3 3 3 3
2 2 2 2 2 2
2 2
123 3 3 3 3 3 3
2 2 2 2 2 2
2 2 2 2 123 3 3 3 3 3 3 32 2 2 2 2
2 222222
1
2 2 2 2
23 333 2
U8032-XL-KK
8033 80348032
8035 8036
Catalog Number Positions Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3
U8032-XL-KK 2 OH/UG† C.P. #6-350 #6-2/0 Horn 41⁄2 241⁄2 16 21⁄2 2 1⁄2
U8033-XL-KK 3 OH/UG† C.P. #6-350 #6-2/0 Horn 41⁄2 3211⁄16 16 21⁄2 2 1⁄2
U8034-XL-KK 4 OH/UG† C.P. #6-350 #6-2/0 Horn 41⁄2 407⁄8 16 21⁄2 2 1⁄2
U8035-XL-KK 5 OH/UG† C.P. #6-350 #6-2/0 Horn 41⁄2 491⁄16 16 21⁄2 2 1⁄2
U8036-XL-KK 6 OH/UG† C.P. #6-350 #6-2/0 Horn 41⁄2 571⁄4 16 21⁄2 2 1⁄2
100 Amp per Position | 4 Terminals | Multi-Position | Center Wireway | Horn Bypass | Ringless
• †Service: Overhead only for We Energy.• Fifth Terminal: For field mounted fifth terminal, order catalog number 5T8K2 for the 6-o’clock position, and K9959 for the 9 o’clock position. Only the U8032-XL-KK is Alliant approved for fifth terminal (U8032-XL-KK-5T9)• Connectors: Extruded aluminum connectors are tin plated.• Bypass: The horn bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.
Notes
1
2 2 2 2 2
22 3333 32
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
19100 AMPMULTI-
POSITIONSOCKETS
Multi-Position Sockets100 Amps | 4 Terminals | Ringless | 300 VAC
L572-XL-KK
13333331 2 2 2 2
2 2 2 2 2
2
2 2 2 2 2 2 11 3 3
2 2 2 2 2 2
122222
2 22222
3 31
1 3 32 2 2
2 2 2 2
Catalog Number
Positions Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3
L572-XL-KK 2 OH/UG C.P. #6-350 #6-2/0 Horn 41⁄2 205⁄16 16 21⁄2 2 1⁄4,1⁄2
L573-XL-KK 3 OH/UG C.P. #6-350 #6-2/0 Horn 41⁄2 281⁄2 16 21⁄2 2 1⁄4,1⁄2
L574-XL-KK* 4 OH/UG C.P. #6-350 #6-2/0 Horn 41⁄2 4011⁄16 16 21⁄2 2 1⁄4,1⁄2
L575-XL-KK* 5 OH/UG C.P. #6-350 #6-2/0 Horn 41⁄2 487⁄8 16 21⁄2 2 1⁄4,1⁄2
L576-XL-KK* 6 OH/UG C.P. #6-350 #6-2/0 Horn 41⁄2 571⁄16 16 21⁄2 2 1⁄4,1⁄2
100 Amp per Position | 4 Terminal | Multi-Position | Horn Bypass | Side Wireway | Ringless
• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.• Fifth Terminal: For field mounted fifth terminal, order catalog number 5T8K2 for the 6-o’clock position, and K9959 for the 9 o’clock position.• Connectors: Extruded aluminum connectors are tin plated.• Bypass: The horn bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.• Alliant: Only the L572 and L573 are approved for overhead and underground applications.*Positions 4, 5 and 6: OH only for Alliant Energy.
Notes
1 2 2
2 22
3 3 L572 L573
L575
L576
L574
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
20100 AMPMULTI-
POSITIONSOCKETS
Multi-Position Sockets100 Amps | 4 Terminals | Ringless | 300 VAC
1 1 1 1 1 1 1
1 1 1 1 1 1 22
1 1 1 1 1
12 21 1 1
• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.• Fifth Terminal: For field mounted fifth terminal, order catalog number 5T8K2 for the 6-o’clock position, and K9959 for the 9 o’clock position.• Connectors: Extruded aluminum connectors are tin plated.• Bypass: The horn bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.
Notes
U7363-RL-KK
Catalog Number Positions Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2
U7362-RL-KK 2 OH H.O. #6-350 #6-2/0 Horn 41⁄2 165⁄16 16 21⁄2 1⁄4,1⁄2
U7363-RL-KK 3 OH H.O. #6-350 #6-2/0 Horn 41⁄2 241⁄2 16 21⁄2 1⁄4,1⁄2
U7364-RL-KK 4 OH H.O. #6-350 #6-2/0 Horn 41⁄2 3211⁄16 16 21⁄2 1⁄4,1⁄2
U7365-RL-KK 5 OH H.O. #6-350 #6-2/0 Horn 41⁄2 407⁄8 16 21⁄2 1⁄4,1⁄2
U7366-RL-KK 6 OH H.O. #6-350 #6-2/0 Horn 41⁄2 491⁄16 16 21⁄2 1⁄4,1⁄2
100 Amp/Position | 4 Terminals | Multi-Position | Horn Bypass | Ringless
1 1 1 1
1112 2
1 1 1
1 22 17362 7363 7364
1 1 1 1 1 1
111112 2 7365 7366
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
21100 AMPMULTI-
POSITIONSOCKETS
Multi-Position Sockets100 Amps | 4 Terminals | Ringless | 300 VAC
U2692-XL-KK
• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.• Fifth Terminal: For field mounted fifth terminal, order catalog number 5T8K2 for the 9 o’clock position.• Connectors: Extruded aluminum connectors are tin plated.• Bypass: The horn bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.
Notes
CatalogNumber
Positions Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4
U2692-XL-KK 2 OH C.P. #2-350 #6-2/0 Horn 41⁄8 8 251⁄4 21⁄2 11⁄2 11⁄4 1⁄4
100 Amp/Position | 4 Terminals | Multi-Position | Horn Bypass | Ringless
26921
22
3 3
4
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
22200 AMPMULTI-
POSITIONSOCKETS
Multi-Position Sockets200 Amps | 4 Terminals | Ringless | 300 VAC
U1252-X-KK-K1-PED(shown without pedestal)
Catalog Number Positions Service HubConnectors CU/AL
BypassDimensions
Line Load D" W" H"
U1252-X-KK 2 OH C.P. 3⁄8" x 16 Studs #6-350 Horn 51⁄8 261⁄2 14
U1253-X-KK 3 OH C.P. 3⁄8" x 16 Studs #6-350 Horn 51⁄8 343⁄4 14
U1254-X-KK 4 OH C.P. 3⁄8" x 16 Studs #6-350 Horn 51⁄8 427⁄8 16
U1252-X-KK-K1-PED 2 UG† C.P. #6-350 #6-350 Horn 51⁄8 261⁄2 14
U1253-X-KK-K3-PED 3 UG† C.P. #4-600 #6-350 Horn 51⁄8 343⁄4 14
U1254-X-KK-K3-PED 4 UG† C.P. #4-600 #6-350 Horn 51⁄8 427⁄8 16
U1255-X-KK-K4-PED 5 UG† C.P. (2) #2-600 #6-350 Horn 51⁄8 541⁄2 16
U1256-X-KK-PED 6 UG† C.P. 3⁄8" x 16 Studs #6-350 Horn 51⁄8 631⁄16 18
200 Amp per Position | 4 Terminal | Multi-Position | Horn Bypass | Ringless
Notes
• †Underground Applications: For underground service, order S2291-TO pedestal raceway. A 12” pedestal extension kit is also available — order catalog number S2571. • Knockouts: See next page for knockout configuration information.• Hubs: For proper hub selection, refer to the hub suffix chart in the accessories section. Two hub openings are supplied (5 and 6 position units only) and the extra opening is closed with a closing plate as standard. To use a hub smaller than 3", the S8324 adaptor is required.• Fifth Terminal: For field mounted fifth terminal, order catalog number K5T (9 o’clock position).• Connectors: Units supplied with 3⁄8"-16 hex head nuts with Belleville washers on line side. Order connector kits K1539 (350 kcmil), K1540 (600 kcmil), or K1541 ((2) 600 kcmil).• Bypass: The horn bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
23200 AMPMULTI-
POSITIONSOCKETS
Multi-Position SocketsU1252 Series | Knockout Information
Knockouts (Pedestal Units)
1
21⁄2
Knockouts (Non-Pedestal Units)
1 2 3 4 5
3 21⁄2 1 1⁄2 1⁄4
1 1 1 1 1 1
1 1 1 1 1 1
1
PED
1 1 1 1 1
1 1 1 1 1
1
PED
1 1 1
1 1 1
1
PED
1 1 1
11 PED
1 1 1 1
1 1 1 1
1
PED
12 234 5 4
2 22
12 4 453
2 2 2 2
2 2 12 2 3 25 2
22222
4 4 4 41
1252 1253 1254
1255 1256
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
24200 AMP
LEVER BYPASSMULTI-POSITION
SOCKETS
Lever Bypass Multi-Position Sockets200 Amps | 5 Terminals | Ringless | 600 VAC
2 2 2 2
2 2 21 1 3 2
22
2 231 1
2 2
287428732872
• Connectors: Units supplied with 3⁄8”-16 hex head nuts with Belleville washers on line side. Order connector kits K1539 (350 kcmil), K1540 (600 kcmil), K1350 ((2) 350 kcmil) or K1541 ((2) 600 kcmil).• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.• Fifth Terminal: Fifth terminal is in 6-o’clock position unless part number includes -5T9, which is in the 9-o’clock position.• MGE Applications: Contact Madison Gas and Electric for approval and mounting instructions.
Notes
U2873-XT
Catalog Number Positions Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3
U2872-XT 2 OH (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 321⁄8 251⁄4 4 21⁄2 1⁄4,1⁄2
U2872-XT-K3 2 OH (2) C.P. #4-600 #6-350 Lever 6 321⁄8 251⁄4 4 21⁄2 1⁄4,1⁄2
U2872-XT-5T9-K3 2 OH (2) C.P. #4-600 #6-350 Lever 6 321⁄8 251⁄4 4 21⁄2 1⁄4,1⁄2
U2873-XT 3 OH (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 423⁄16 251⁄4 4 21⁄2 1⁄4,1⁄2
U2873-XT-K3 3 OH (2) C.P. #4-600 #6-350 Lever 6 423⁄16 251⁄4 4 21⁄2 1⁄4,1⁄2
U2874-XT 4 OH (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 521⁄4 251⁄4 4 21⁄2 1⁄4,1⁄2
U2874-XT-K3 4 OH (2) C.P. #4-600 #6-350 Lever 6 521⁄4 251⁄4 4 21⁄2 1⁄4,1⁄2
200 Amps per Position | 5 Terminals | Multi-Position | Ringless
2 2
21 1 3 22
2 2
2 2 2 2 2
2 2 1 1 3 2 2 2
2 2 2
1 1 3
2 2 2 2 2
2 2 2 2 2 22875 2876
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
25200 AMP
LEVER BYPASSMULTI-
POSITIONSOCKETS
Lever Bypass Multi-Position Sockets200 Amps | 7 Terminals | Ringless | 600 VAC
U2732-XT-PED(shown without pedestal)
• Knockouts: See next page for knockout configuration information.• Hubs: Units supplied with two closing plates. To order as extra, refer to the hub suffix chart in the accessories section.• Connector Kits: For line side connector kits, order as extra K3082 (350 kcmil), K3441 (600 kcmil), K3442 (twin 350 kcmil),
or K3083 (twin 600 kcmil). Line connectors can be reversed to change from overhead to underground service.• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.• Underground Applications: For underground service, order S2291-TO raceway. A 12" pedestal extension kit is also
available—order catalog number S2571.• MGE Applications: Contact Madison Gas and Electric for approval and mounting instructions.
Notes
Catalog Number Positions Service HubConnectors CU/AL Dimensions
Line Load D" W" H"
U2732-XT-PED 2 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 321⁄8 251⁄4
U2732-XT-PED-K7 2 OH/UG (2) C.P. #4-600 #6-350 6 321⁄8 251⁄4
U2733-XT-PED 3 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 423⁄16 251⁄4
U2733-XT-PED-K7 3 OH/UG (2) C.P. #4-600 #6-350 6 423⁄16 251⁄4
U2734-XT-PED 4 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 521⁄4 251⁄4
U2734-XT-PED-K7 4 OH/UG (2) C.P. #4-600 #6-350 6 521⁄4 251⁄4
U2735-XT-PED 5 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 625⁄16 251⁄4
U2735-XT-PED-K7 5 OH/UG (2) C.P. #4-600 #6-350 6 625⁄16 251⁄4
U2736-XT-PED 6 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 723⁄8 311⁄4
U2736-XT-PED-K7 6 OH/UG (2) C.P. #4-600 #6-350 6 723⁄8 311⁄4
200 Amps per Position | 7 Terminals | Multi-Position | Ringless
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
26200 AMP
LEVER BYPASSMULTI-
POSITIONSOCKETS
Lever Bypass Multi-Position SocketsU2732 Series | Knockout Information
1 1 1 1
1 1 1PED 2 1
1
1
1 12
1 1
PED2732
2733 2734
1 1
1PED 2 11
1 1
1 1 1 1 1
1 1 2 1PED 1 1
11 1
2
1 1 1 1 1
1 1 1 PED 1 1 12735 2736
Knockouts
1 2
21⁄2 1⁄4,1⁄2
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
27125–200 AMP
MULTI-POSITION
METER MAINS
Multi-Position Meter Mains125-200 Amps | 4 Terminals | Ringless | 120/240 VAC
Catalog Number Amps Positions Service HubConnectors CU/AL
BypassDimensions Weight
(lbs.)Line Load D" W" H"
U5902-X-KK-K1-PED 125 2 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 261⁄2 30 58
U5903-X-KK-K1-PED 125 3 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 345⁄9 30 88
U5904-X-KK-K1-PED 125 4 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 424⁄5 30 107
U5905-X-KK-K1-PED 125 5 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 511⁄20 30 128
U5906-X-KK-K1-PED 125 6 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 593⁄10 30 146
Catalog Number Amps Positions Service HubConnectors CU/AL
BypassDimensions Weight
(lbs.)Line Load D" W" H"
U5882-X-KK-K1-PED 200 2 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 261⁄2 30 58
U5883-X-KK-K1-PED 200 3 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 345⁄9 30 88
U5884-X-KK-K1-PED 200 4 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 424⁄5 30 107
U5885-X-KK-K1-PED 200 5 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 511⁄20 30 128
U5886-X-KK-K1-PED 200 6 OH/UG C.P. 1/0-350 #6-350 Horn 51⁄8 593⁄10 30 146
125 Amps per Position | 4 Terminals | Multi-Position Meter Mains | Horn Bypass | Ringless
200 Amps per Position | 4 Terminals | Multi Position Meter Mains | Horn Bypass | Ringless
• Knockouts: See drawings on the next page.• Alliant Energy Use: For use on Alliant Energy lines, omit the -PED from the catalog number.• AIC Rating: All models are rated 22K AIC when used with approved breakers rated at 22K.• Hub: Units supplied with one (1) closing plate. Order hubs separately, see the accessories page.• Fifth Terminal: For field installed fifth terminal, order K5T. • Underground Applications: Order the S2291-TO pedestal raceway.
Notes
U5882-X-KK-K1 U5884-X-KK-K1
Breaker Chart - 10K AIC (unless noted 22K)
Manufacturer Cutler Hammer Siemens G.E. (50 Amp Max) Square D
125 Amps or Less BR, HQP, QPGF QP, QPH (22K) THQL, THQL-GF Homeline
150-200 Amp BR, BJ QN, QNH (22K) — —
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
28125-200 AMP
MULTI-POSITION
METER MAINS
Multi-Position Meter MainsU5882 & U5902 Series | Knockout Information
30"
26.5"
1 34 45 22
2 2
58825902
5.125"
30”
26.5”
2
2
2
2
5.13”
PED
34.56"
30"
12 3 22 158835903
5.125"
30”
5.13”34.56”
2 2 2PED
2 2 2 2
30”
42.81” 5.13”
PED
30"
51.06"5.125"
1 12 2 2 2 2358855905
30”
51.06” 5.13”
2 2 2 2 2PED
1 12 2 2 2 2 23
30"
59.31"5.125"
58865906
2 2 2 2 2 2
30”
59.31” 5.13”
PED
58825902
5884 5904
5885 5905
58835903
Knockouts
1 2 3 4 5
3 21⁄2 1 7⁄8 1⁄4
30"
42.81" 5.125"
1 3 1 222 2
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
2920 AMP
TRANSFORMERRATED SOCKETS
1
1 1 1 2
12
1
4
33
2
Transformer Rated Meter Sockets20 Amps | 5–13 Terminals | Ringless
1 1
1 211
UC7448-XL
744874497532
12901299
38873889
Catalog Number TerminalsMeter Form
Cover Service HubConnectors
CUBypass
Dimensions Knockouts
D" W" H" 1 2 3 4
UC1290-RL 5 3S 1-Piece OH/UG H.O. #14-2 Max Plunger 35⁄16 8 14 2 11⁄2 11⁄4 1⁄4
UC1299-RL 6 4S 1-Piece OH/UG H.O. #14-2 Max Plunger 35⁄16 8 14 2 11⁄2 11⁄4 1⁄4
UC7532-XL 6 4S 2-Piece OH/UG C.P. #14-2 Max None 41⁄8 12 20 11⁄4 1⁄4,1⁄2 — —
UC7448-XL 8 5S 2-Piece OH/UG C.P. #14-2 Max None 41⁄8 12 20 11⁄4 1⁄4,1⁄2 — —
UC3887-XL 8 5S 1-Piece OH/UG C.P. #14-2 Max None 5 13 19 11⁄4 1⁄4,1⁄2 — —
UC7449-XL 13 6, 8, 9 & (ALT) 10S 2-Piece OH/UG C.P. #14-2 Max None 41⁄8 12 20 11⁄4 1⁄4,1⁄2 — —
UC3889-XL 13 6, 8, 9 & (ALT) 10S 1-Piece OH/UG C.P. #14-2 Max None 5 13 19 11⁄4 1⁄4,1⁄2 — —
20 Amps | Transformer Rated Meter Sockets | Ringless
Notes
• Hubs: For proper hub selection, see the hub suffix chart in the accessories section.• UC1290 and UC1299: These units do not have a test switch provision.• Pre-wiring: If factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch
model and number, and meter form number. Please be sure to provide a copy of your wiring diagram.• Utility Approval: For utility approval information see pages 69-71.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
3020 AMPMULTI-
POSITIONTRANSFORMER
RATED
Multi-Position Transformer Rated20 Amps | 8–13 Terminals | Ring Type
1
1 2 1
1 1
UC2428-XL
24272428
Catalog Number TerminalsMeter Form
Cover Service HubConnectors
CUBypass
Dimensions Knockouts
D" W" H" 1 2
UC2427-XL 8 5S 2-Piece OH/UG C.P. #14-2 Max None 41⁄8 241⁄16 20 11⁄4 1⁄4,1⁄2
UC2428-XL 13 6, 8, 9 & (ALT) 10S 2-Piece OH/UG C.P. #14-2 Max None 41⁄8 241⁄16 20 11⁄4 1⁄4,1⁄2
20 Amps | Transformer Rated Meter Sockets | Ring Type
• Sealing Rings: These units are supplied with two MR-4 screw type sealing ring.• Hubs: For proper hub selection, see the hub suffix chart in the accessories section.• Pre-wiring: If factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram.• Utility Approval: For utility approval information see pages 69-71.
Notes
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
31200 AMP
LEVER BYPASSMETER
PEDESTALS
Meter Socket Pedestals200 Amps | 4 Terminals | Ringless | 600 VAC
Notes
• Extension Unit: For 15” burial applications for the U3358, order extension unit K5800; for 30” burial applications, order two of K5800. For the U1783, order S8988.
• Fifth Terminal: For field-mounted fifth terminal, order K5T to install in the 9-o’clock position.• Horn Bypass: The -KK horn bypass is factory installed and permits changing and testing of the meter without interrupting
customer service when used with utility-supplied jumpers.• Short Circuit Current Rating: The U3358 has a 30K SCCR rating.*U3358: K6366 can be used when dual line side lugs are needed.
Catalog Number Positions Terminals Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3
U3358-O-KK* 1 4 UG Blank #6-350 #6-350 Horn 41⁄8 9 62 2 3⁄4 —
U1783-O-KK 2 4 UG Blank #6-350 #6-350 Horn 41⁄2 81⁄5 74 21⁄2 11⁄3 1⁄2
200 Amp | Meter Pedestals | Horn Bypass | Ringless
1
1
1
2
2
1
1
U1783-O-KKU3358-O-KK
3358 1783
1 1
1 1 1
3
2
3
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
32200 AMP
LEVER BYPASSMETER
PEDESTAL
Lever Bypass Meter Pedestals200 Amps | 5 & 7 Terminals | Ringless | 600 VAC
U9107-O-WI
• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.• Neutral Disconnect: The U9108 has a manual neutral disconnect bolt.• Direct Burial: For free standing use, order separately burial kit S3488.• U9108 Single Phase: To use U9108-O-WI in single phase applications, field install kit K6027 (ordered separately).• MGE Applications: The U9108 is for 3-phase use only on Madison Gas and Electric lines.
Notes
Catalog Number Terminals Phase Service HubConnectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2
U9108-O-WI 5 1Ø3W or 3Ø3W UG Blank #6-350 #6-350 6 11 58 21⁄2 5⁄16
U9107-O-WI 7 3Ø4W UG Blank #6-350 #6-350 6 11 58 21⁄2 5⁄16
U9107-O-CECHA 7 3Ø4W UG Blank #6-350 #6-350 6 11 58 21⁄2 5⁄16
200 Amps | Metered Pedestals | Lever Bypass | Ringless
1 1 1
2
2 2
2
91079108
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
33200 AMP
LEVER BYPASSMETER
PEDESTALS
Lever Bypass Meter Pedestals200 Amps | 4 & 5 Terminals | Ringless | 600 VAC
Catalog Number Terminals Voltage Service HubConnectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1
U4724-O 4 600 UG Blank 3/0-4/0 #6-350 6 11 64 21⁄2
U4724-O-5T9 5 600 UG Blank 3/0-4/0 #6-350 6 11 64 21⁄2
200 Amps | Metered Pedestals | Lever Bypass | Ringless
• Lever Bypass: Lever provides clamping action on meter spades and also operates bypass device.• Fifth Terminal Kit: For field-installed fifth terminal, order catalog number K3865 (neutral wire provided). Units with -5T9 suffix supplied with fifth terminal factory installed at 9 o’clock.• MGE Applications: The U4724-O-5T9 is for single phase, three wire use only on Madison Gas and Electric lines.
Notes
U4724-O-5T9
4724
1 1 1
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
34100-200 AMPMETER MAINPEDESTALS
Meter Main Pedestal100–200 Amps | 4 Terminals | Ringless | 120/240 VAC
Grade Line
1
1
NU8980-O-200-KK
8980
100 & 200 Amp | 4 Terminal | Horn Bypass | Ringless
Catalog Number Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1
NU8980-O-KK UG Blank #6-350 CB* Horn 6 9 79 21⁄2
NU8980-O-KK-LP UG Blank #6-350 CB* Horn 6 9 70 21⁄2
NU8980-O-SF100-KK UG Blank #6-350 #6-1/0 Horn 6 9 79 21⁄2
NU8980-O-SF100-KK-LP UG Blank #6-350 #6-1/0 Horn 6 9 70 21⁄2
NU8980-O-200-KK UG Blank #6-350 1/0-300 Horn 6 9 79 21⁄2
NU8980-O-200-KK-LP UG Blank #6-350 1/0-300 Horn 6 9 70 21⁄2
* Field installed circuit breaker required.• Series Wired Main: For series wired main, order wire kit K4714 for black interior and the K5194 for red interior and
UQFPH-M type circuit breaker.• SF: SF in catalog number has small frame plug-in type circuit breaker installed on middle stabs of 4-circuit
interior. Only two single pole spaces available.• Fifth Terminal: For field-installed 5th terminal order kit K5T. Mounts in 9 o’clock position only.• Extension Kit: Available for low profile (-LP) units only. Order kit K4694.• Branch Circuit Breakers (Four Additional Single Pole Spaces): Branch interior accepts most manufacturers’ small frame
plug-in type circuit breakers (GE, Siemens, Cutler Hammer, Murray). Load center rated up to 125 amps max.
Notes
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
35100-200 AMPMETER MAIN
W/ LOAD CENTERPEDESTALS
Meter Main with Load Center Pedestal100–200 Amps | 4 Terminals | Ringless | 120/240 VAC
100 & 200 Amps | 4 Terminal | All-In-One Pedestal | Horn Bypass | Ringless
100 & 200 Amps | 4 Terminal | All-In-One Pedestal | Lever Bypass | Ringless
Catalog Number Service Bypass CircuitsConnectors CU/AL Dimensions Knockouts
Line Load D” W” H” 1 2 3 4 5
U5925-O-100-KK UG Horn 10 #6-350 CB 37⁄16 14 78 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2
U5925-O-150-KK UG Horn 8 #6-350 CB 37⁄16 14 78 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2
U5925-O-200-KK UG Horn 8 #6-350 CB 37⁄16 14 78 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2
Catalog Number Service Bypass CircuitsConnectors CU/AL Dimensions Knockouts
Line Load D” W” H” 1 2 3
U6221-O-100-10GR* UG Lever 10 #6-350 CB 41⁄8 911⁄16 80 2 1⁄2 1⁄4
U6221-O-200-10GR* UG Lever 8 #6-350 CB 41⁄8 911⁄16 90 2 1⁄2 1⁄4
Notes
• Fifth Terminal: For field installed fifth terminal, order K5T.• Branch Circuit Breakers: Branch interior accepts most manufacturers’ small frame plug-in type circuit breakers (GE, Siemens, Cutler Hammer, Murray).• U6221 with 10GR has the 520GR included.* When used in an Alliant territory the U6221 must have a shielded GFI receptacle. Use kit number K6265-HRD.
U5925-O-200-KK U6221-O-100-10GR
1
2 3
3
4
5
2 2
1
1
Grade Level
24”
46.875”
78”
14”3.4”
4.5”
Grade Level
24”
48”
80”
911/16”41/8 ”
4.5”
1 1 1
23
5925
6221
K5815Large QN with small frame Q
K5820 Large frame QN with large frame
QN
K5830 Small frame Q to
small frame Q
Generator Interlock (compatible with U5925)
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
36200 AMP
METER MAINW/ LOAD CENTER
PEDESTALS
Meter Main with Load Center Pedestal200 Amps | 4 Terminals | Ringless | 120/240 VAC
U5136-O-200S
24”
27.5”
50”
80”
Grade Level
1
1
2 2
3 3
1
1
9.875”4.13”
16.07”
51365137
200 Amps | 4 Terminals | Meter Main Pedestal | Horn Bypass | Ringless
Catalog Number ServiceAIC
RatingConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3
U5136-O-100S UG 22K #6-350 CB Horn 41⁄8 97⁄8 80 2 1⁄2,3⁄4 1⁄4
U5136-O-150S UG 22K #6-350 CB Horn 41⁄8 97⁄8 80 2 1⁄2,3⁄4 1⁄4
U5136-O-200S UG 22K #6-350 CB Horn 41⁄8 97⁄8 80 2 1⁄2,3⁄4 1⁄4
U5137-O-100S UG 22K #6-350 CB Horn 41⁄8 97⁄8 80 2 1⁄2,3⁄4 1⁄4
U5137-O-150S UG 22K #6-350 CB Horn 41⁄8 97⁄8 80 2 1⁄2,3⁄4 1⁄4
U5137-O-200S UG 22K #6-350 CB Horn 41⁄8 97⁄8 80 2 1⁄2,3⁄4 1⁄4
Notes
• Fifth Terminal: For field installed fifth terminal, order K5T.• Stabilizer Foot: For field installed stabilizer foot, order K5415.• Penta Bolt Locking: For field installed pedestal fronts penta bolt locking, order K5039.• Receptacles: Consult factory for installed receptacle assemblies.• U5137: Double power head version.• Branch Circuit Breakers (Four Additional Single Pole Spaces): Branch interior accepts most manufacturers’ small frame
plug-in type circuit breakers (GE, Siemens, Cutler Hammer, Murray). Load center rated up to 125 amps max.• Use part number K6265-HRD when adding a 120V 20 amp GFI receptacle in Alliant territory.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
37200 AMP
METER MAINW/ LOAD CENTER
PEDESTALS
Meter Main with Load Center Pedestal200 Amps | 4 Terminals | Ringless | 120/240 VAC
200 Amps | 4 Terminals | Meter Main Pedestal | Horn Bypass | Ringless
Catalog Number Service BypassConnectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2 3 4
U5706-O-200S-KK UG Horn #6-350 CB 51⁄2 14 80 21⁄2 2 1 1⁄4,1⁄2
Notes
• Fifth Terminal: For field installed fifth terminal, order K5T.• Branch Circuit Breakers (Four Additional Single Pole Spaces): Branch interior accepts most manufacturers’ small frame
plug-in type circuit breakers (GE, Siemens, Cutler Hammer, Murray). Load center rated up to 125 amps max.• Use part number K6265-HRD when adding a 120V 20 amp GFI receptacle in Alliant territory.
U5706-O-200S-KKPicture shown with bridge
K5400-BRIDGE-3POS installed
5706
1
1
1
1 2
3
3
4
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
38
24”
22”
48”
80”
Grade Level
12 2
3 3
1
9.875”4.13”
16.07”
100-200 AMPMETER MAIN
W/ LOAD CENTERPEDESTAL
100-200 Amp | 5 Terminal | Meter Main Pedestal | Heavy Duty Lever Bypass | Ringless | 1Ø3W
Catalog NumberMeter
PositionsBypass
Mounting Type
Number of power units
Twin Line Connectors CU/AL
Circuit Provisions
Knockouts
1 2 3
U5701-0-100S Single Lever D.B. Post 1 #6-350 4 2 3⁄4 1⁄4
U5701-0-150S Single Lever D.B. Post 1 #6-350 4 2 3⁄4 1⁄4
U5701-0-200S Single Lever D.B. Post 1 #6-350 4 2 3⁄4 1⁄4
• Lever Bypass: Lever provides clamping action on meter spades and also operates bypass device.• Breakers: Quadplex style breakers may be used in accordance to the NEC. If main breaker is used, there are provisions for
two 2-pole breakers or four 1-pole breakers in series.• Kits: For 5701 and 5702 order stabilizer kit K5415. For 5703 order pad mount kit K5035. • If receptacles are required contact factory for additional kit information. Two outlet devices maximum can be installed.• *The U5702 is a back to back unit with 2 power heads.
Notes
Meter Main with Load Center Pedestal100-200 Amp | 5 Terminal | HD Lever Bypass | Ringless
120/240 VAC
U5701-O-200SPicture shown with bridge
K5400-BRIDGE-3POS installed
5702*
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
39200 AMP
METER MAINW/ LOAD CENTER
PEDESTALS
Meter Main with Load Center Pedestal200 Amps | 5 Terminals | Lever Bypass | 120/240 VAC
12"
21"
55"
5 1/2"
4 1/8"
StabilizerFoot
1 1 1
23
9 7/8"
43224323
200 Amps | 5 Terminals | Meter Main Pedestals | Lever Bypass | Ringless
Catalog NumberMeter
PositionsBypass
Connectors CU/AL CircuitProvisions
Knockouts Dimensions
Line Load 1 2 3 D" W" H"
U4322-O-5T9 Single Lever Twin #6-350 CB 6 2 1⁄2 1⁄4 95⁄8 97⁄8 55
U4323-O-5T9 Double Lever Twin #6-350 CB 6 2 1⁄2 1⁄4 151⁄8 97⁄8 55
Notes
• Lever Bypass: Lever provides clamping action on meter spades and also operates bypass device• Application: The U4322 & U4323 pedestals are suitable for use as service equipment or mobile home service equipment.
K5081/K3188 for direct burial application is included with unit. K5151 for pad mount application must be ordered as extra.• Breakers: These units are wired as parallel mains and have provisions for six circuits: 6 single-pole or 3 double-pole
breakers.• Short Circuit Current Rating: 10K AIC. However, this rating is limited to the lowest interrupting capacity of any circuit
breaker installed. Watthour meter not included in short circuit current rating.• Main Breaker sold separately.
U4322-O-5T9 U4323-O-5T9
Breaker Chart
Manufacturer 150–200 Amps 125 Amps or Less
Cutler Hammer BJ, WBJ Quicklag P BR, HQP
Siemens (ITE) QNR QP
Murray MD MP
G.E. — Q Line
Square D — Homeline
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
40320 AMP
METER MAINW/ LOAD CENTER
PEDESTALS
Meter Main Pedestal320 Amps | 4 Terminals
Notes
• Breakers: Supplied from factory with 2 double-pole, Milbank UQFB or UQFBH (22K AIC) bolt-on circuit breakers.• Connectors: The line wire section is supplied with 3/8”-16 studs with hex nuts and captive Bellville washers. For line side
connectors,order as extra catalog numbers K1539 (single-350 kcmil), or K1540 (single-600 kcmil), or for twin K1350 (twin-350 kcmil). Order one kit per unit.
• Extension Kit: For extension kit, order as extra catalog number S1848.• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.• Short Circuit Current Rating: These units are rated 22K AIC. However, this rating is limited to the lowest interrupting
capacity of any circuit breaker installed. Watthour meter not included in short circuit current rating.• Alliant Approved: Limited to 300 amp; U6317 only.
U3849-O-2-200
18"
Grade Line
1 1
2 2
1
Grade Line
2 2
13" O.D.
16-15/16"15"
4-27/32"I.D.
320 Amps | 4 Terminals | Meter Main Pedestal | Ringless | 120/240 VAC
Catalog Number Terminals Service Hub BypassConnectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2
U3849-O-200-100 4 UG Blank Lever 3⁄8" x 16 Stud 1/0-300 47⁄8 13 64 21⁄2 5⁄16
U3849-O-2/150 4 UG Blank Lever 3⁄8" x 16 Stud 1/0-300 47⁄8 13 64 21⁄2 5⁄16
U3849-O-2/200 4 UG Blank Lever 3⁄8" x 16 Stud 1/0-300 47⁄8 13 64 21⁄2 5⁄16
3849
S1848
Catalog Number Terminals Service Hub BypassConnectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2
U6317-O-2/150-K3L 4 UG Blank Lever 3⁄8” x 16 Studs Twin #6-350 47⁄8 13 64 21⁄2 5⁄16
U6317-O-200-100-K3L 4 UG Blank Lever 3⁄8” x 16 Studs Twin #6-350 47⁄8 13 64 21⁄2 5⁄16
Alliant Approved | 300 Amp | Meter Main with Breakers | Ringless
U6317-O-2/150
1
1
1
1
6317
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
41320 AMP
METER MAINW/ LOAD CENTER
PEDESTALS
Meter Socket Pedestal320 Amps | 4 & 5 Terminals
Notes
• Connectors: On the U1748-O-WI and U1748-O-5T9-WI, the connectors K1539 (single-350 kcmil) are factory installed on the line side. Load side is furnished with K1350 (twin-350 kcmil).
• Extension Kit: For extension kit, order as extra catalog number S1848.• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.• Hanging Hook: Units supplied with hanger hooks for easy mounting.• Short Circuit Current Rating: These units are rated 22K AIC. Watthour meter not included in short circuit current rating.
U1748-O-WI
13" O.D.
16-15/16"15"
4-27/32"I.D.
Grade Line Grade Line
1
2 218”
1 1
11
2 2
320 Amps | Ringless | 600 VAC
Catalog Number Terminals Service Hub BypassConnectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2
U1748-O-WI 4 UG Blank Lever #6-350 (2) #6-350 47⁄8 13 64 21⁄2 5⁄16
U1748-O-5T9-WI 5 UG Blank Lever #6-350 (2) #6-350 47⁄8 13 64 21⁄2 5⁄16
1748 S1848
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
42JOINT USE
TERMINATIONCABINETS
Grade Line
12"
58"
13" 4 1/2"
37 5/16" 33 5/16" 39"
21"
6"1
1
1 1
1
2
3
1
1
4329
Joint Use Termination Cabinet
Catalog Number Hub BypassConnectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2 3
U4329-O Blank None None None 47⁄8 13 58 1 1⁄2 7⁄16
Notes
• Communication Compartment: Easily attaches to Milbank meter pedestals for use in new construction.• Telephone and Cable Conductors: This unit will accommodate both telephone and cable conductors, eliminating the use
of multiple, unsightly network interface devices on the outer structure of the home, while providing tamper resistance to the communication modules.
• Single Location Point of Service: The U4329 combined with the Milbank meter pedestal provides a single location point of service, making access for utility service personnel convenient and efficient.
U4329-O
Joint Use Termination CabinetAccommodates telephone and cable conductors
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
43POLYPHASE
ENCLOSURES
Glass Window Demand Reset Cover All Metal Demand Reset Cover Window Shield
SDRCW SDRC WS
Polyphase EnclosuresFor “A” Base Meters
Pole Mounting BracketsOrder #830 for one pair (2 pcs.) with keyhole
bracket and mounting hardware. Order #850 for two pair (4 pcs.) with
mounting hardware.
Notes
• Bridge and Mounting Board: Units are supplied with board and bridge.• Windows and Covers: Units supplied with one 41⁄2" x 6 glass window per meter position. If glass demand reset window is
desired, add suffix -CW to the catalog number. If metal demand reset cover is desired, add suffix -C to the catalog number. If window shield is desired, add suffix -WS to the catalog number.
• Hubs: Units supplied with closing plate. Order hub as extra; refer to the accessories page.
S9997-B-XL S9997-B-XL
830 850
Polyphase Enclosures
Field Installed Accessories
Catalog Number Hub PositionsDimensions
D" W" H"
S9995-B-XL C.P. 1 11 15 26
S9996-B-XL C.P. 1 11 15 3011⁄16
S9997-B-XL C.P. 2 11 27 3011⁄16
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
44TYPE K4
METER SOCKETS
Type K4 Meter Sockets4 Terminals | 480 Amps Cont. | Ringless | 300 VAC
U4664-X
1 1
2 2 3
1
1 1 1
CatalogNumber
Service HubL & G
NumberLugKit
Connectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2 3
U4664-X-8502 OH/UG C.P. 9810-8502 Installed Twin #6-350 Twin #6-350 6 173⁄4 36 4 1⁄2,3⁄4 1⁄4
U4664-X-8507 OH/UG C.P. 9810-8507 None 1⁄2-20 Stud 1⁄2-20 Stud 6 173⁄4 36 4 1⁄2,3⁄4 1⁄4
U4664-XT-9507 OH/UG (2) C.P. 9810-9507 None 1⁄2-20 Stud 1⁄2-20 Stud 6 173⁄4 36 4 1⁄2,3⁄4 1⁄4
480 Amps | 4 Terminals | Ringless | Type K4 Meter Sockets
Notes
• Application: For use with 1Ø3W self-contained Type MS-K watthour meters.• Capacity: 480 amp continuous, 600 amp maximum.• Connectors: 1⁄2"-20 plated steel studs with nuts and captive Belleville washers to accommodate various bolt-on type lugs
for conductors from #6 to 800 kcmil CU or AL. Use 3⁄4" insulated wrench to fasten connectors to block. U4664-X8502 includes phase and neutral connectors. For lugs, refer to page 45.
• Enclosure: Constructed of 14-gauge galvanized steel suitable for indoor or outdoor installations.• Bypass: Rated 50%, separate manual type, order Milbank kit #K4687 (kit includes 2 bypasses).• Meter Mounting: Two position stud type. One set of studs provides out-of-service storage. The in-service studs are
positioned so the meter cannot be installed upside-down. Full travel meter opening slide plate eliminates the need for repositioning the slide plate for the “IN” or “OUT OF SERVICE” position.
• Blocks: Glass fiber reinforced polyester plastic. High arc withstand strength and track resistant. Provisions for lighting arresters.
4664
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
45TYPE K7
METER SOCKETS
Type K7 Meter Sockets7 Terminals | 480 Amps Cont. | Ringless | 600 VAC
U4667-X-8013
CatalogNumber
Service HubL & G
NumberLugKit
Connectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2 3
U4667-X-8512 OH/UG C.P. 9817-8512 Installed Twin 4-500 Twin 4-500 6 201⁄4 43 4 1⁄2,3⁄4 1⁄4
U4667-XT-9504 OH/UG (2) C.P. 9817-9504 None 1⁄2-20 Stud 1⁄2-20 Stud 6 201⁄4 43 4 1⁄2,3⁄4 1⁄4
U4667-XT-9506 OH/UG (2) C.P. 9817-9506 Installed Twin 4-500 Twin 4-500 6 201⁄4 43 4 1⁄2,3⁄4 1⁄4
U4667-X-8013 OH/UG C.P. 9817-8013 Installed Twin 4-500 Twin 4-500 6 201⁄4 43 4 1⁄2,3⁄4 1⁄4
480 Amps | 7 Terminals | Ringless | Type K7 Meter Sockets
Notes
• Application: For use with self-contained Type MT-K watthour meters on 3Ø4W Wye or 4-wire delta services.• Capacity: 480 amp continuous, 600 amp maximum.• Connectors: 1⁄2"-20 plated steel studs with nuts and captive Belleville washers to accommodate various bolt-on type lugs
for conductors from #6 to 800 kcmil CU or AL. Use 3⁄4" insulated wrench to fasten connectors to block. For lugs, refer to page 46.
• Enclosure: Constructed of 14-gauge galvanized steel suitable for indoor or outdoor installations.• Bypass: Rated 50%, separate manual type, order Milbank kit #K4688 (kit includes 3 bypasses).• Meter Mounting: The meter is mounted on 6 studs using 5⁄16"-24 studs with nuts with captive Belleville washers. The upper
studs are positioned so that the meter cannot be installed upside-down. Use 1⁄2" insulated wrench. Another set of studs provides on site “OUT OF SERVICE” storage. Full travel meter opening slide plate eliminates the need for repositioning the slide plate for the “IN” or “OUT OF SERVICE” position.
1 1 1
1
2 23
1 14667
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
46K4/K7 SERIESSCHEMATICS
K4/K7 Series Schematics Wiring and Lug Kit Information
K4 Lug Kit(overhead)
K4 Lug Kit(underground)
K7 Lug Kit(underground)
K7 Lug Kit(underground)
LugMilbank Connector
NumberLine/Load Feed
(OH/UG)Description
K4Z703917-ACZ705456-ACZ705420-AC
ParallelLine/LoadOH/UG
(2) Twin #6-350 kcmil connector (phase)(2) Twin #6-350 kcmil connector (phase)
(1) Quad #6-350 connector (neutral)
K7Z704693-ACZ704694-AC
ParallelLine/Load
UG
(3) Twin #2-500 kcmil connector (phase)(5) Twin #4-500 kcmil connector (phase)
K7Z703919-ACZ703918-AC
ParallelLine/Load
UG
(3) Twin #6-350 kcmil connector (phase)(5) Twin #4-350 kcmil connector (phase)
Milbank Bypass L&G Bypass Description
K4687 56495 Manual bypass for K-4 Series (U4664). Kit includes 2.
K4688 58888 Manual bypass for K-7 Series (U4667). Kit includes 3.
Notes
• Bypass: Rated 50%, separate manual type.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
47LUGS FORK-SERIES
Lugs for K-SeriesL&G Cross-Reference
H
L
W
Milbank ConnectorNumber
L&G Connector Number
# of Conductorsand Size
StudOpening
Pressure Screw Head
DimensionsL" W" H"
Z703916-AC 58852 3/0-800 kcmil 9⁄16” 1⁄2” Allen 315⁄16 13⁄4 113⁄16
Z703917-AC 56427 Two #6-350 kcmil 9⁄16” 5⁄16” Allen 45⁄16 11⁄8 21⁄16
Z703918-AC 56732 Two #4-350 kcmil 9⁄16” 5⁄16” Allen 27⁄8 159⁄64 11⁄4
Z703919-AC 58853 Two #6-350 kcmil 9⁄16” 5⁄16” Allen 315⁄16 11⁄8 11⁄2
Z703921-AC 56476 3/0-800 kcmil 9⁄16” 1⁄2” Allen 31⁄4 15⁄16 113⁄16
Z704693-AC 56427-M Two #2-500 kcmil 9⁄16” 3⁄8” Allen 41⁄4 11⁄8 113⁄16
Z704694-AC 56732-M Two #4-500 kcmil 9⁄16” 3⁄8” Allen 213⁄16 25⁄32 113⁄16
Z705420-AC 56426 Four #6-350 kcmil 17⁄32” 5⁄16” Allen 27⁄8 315⁄16 19⁄16
Z705456-AC 56425 Two #6-350 kcmil 9⁄16” 5⁄16” Allen 27⁄8 157⁄64 11⁄4
Z708145-AC 68752-1 Three #6-250 kcmil 9⁄16” 5⁄16” Allen 27⁄8 21⁄2 15⁄16
#Z703916-AC | #58852
#Z703921-AC | #56476 #Z705420-AC | #56426 #Z705456-AC | #56425
#Z708145-AC
#Z703918-AC | #56732#Z704694-AC | #56732-M
#Z703919-AC | #58853#Z704693-AC | #56427-M
Bolt-on type lugs for Milbank stud type meter mounting devices are made of 6061-T6 aluminum to provide high strength and high conductivity. All lugs are tin-plated to ensure low contact resistance and to reduce corrosion. Allen or hex head pressure screws are furnished to provide excellent conductor spread for maximum binding action with the lug.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
48COMMERCIALPEDESTALS
Commercial PedestalsAttractive | Easy to Install | Secure | Cost-Effective
Milbank Commercial Pedestals are pad-mounted, weather resistant electrical enclosures consisting of a utility pull section with optional meter socket, and a customer section containing distribution and control equipment. Milbank Commercial Pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures.
UL Listed as Industrial Control Equipment (File E113855)
Strut and backboard Commercial pedestal
• Type 3R rain-resistant, vandal-resistant cabinet of polyurethane powder coated steel (aluminum or stainless steel also available)• UL listed as enclosed industrial control equipment (UL508)• Isolated lockable and sealable utility metering and lug landing sections• Lockable customer section for distribution and control equipment with internal deadfront• Print pocket inside customer section door contains wiring schematics and installation instructions• Most load centers are UL listed for use with various manufacturers’ circuit breakers• All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws)
Standard Features Note
All meter form and bypass options
available to meet utility requirements.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
49COMMERCIALPEDESTALS
K3865Fifth terminal kit for use with ringless meter sockets
CP-ABK5/8Anchor bolt kit (includes four 5⁄8 - 13 x 18” anchor bolts
105JFifth terminal kit for use with ring type meter sockets
CP-PE-HOA-3POSHOA switch for field installation
CP-TC7D 7-day time clock kitCP-TC24H24-hour time clock kitCP-TCWIREMale 4-pin connector and wiring harness for use with time clocks other than above
CP-16PDMNT-CALT 16" pedestal mounting baseCP-24PDMNT-CALT 24” pedestal mounting base (includes mounting hardware)
Commercial PedestalsAttractive | Easy to Install | Secure | Cost-Effective
Accessories
These units are ideal for controlling and metering:• Traffic signals• Street lighting• Power distribution for EV charging stations• Irrigation and sprinkler systems• Cell towers and telephone vaults• Pump stations• Temporary power for fairgrounds, swap meets, outdoor markets,
portable offices, holiday lights, etc.• Outdoor lighting for athletic fields, tennis and basketball courts,
parking lots, landscaping and subdivision entrances, etc.
• Meter sockets: ring type or ringless, up to 400 amp• Main and branch breakers or T fuses• Distribution: copper load centers and panel boards• Clocks, timers and relays• Photoelectric cells and controls• Power receptacles: pin and sleeve, twist lock or straight blade• Contactors: definite purpose, electrical or mechanically held, IEC
and mercury types• Surge protection and lightning arrestors• Reserve inlet generator receptacle with interlocked circuit breakers• Motor starters and relays• Push button controls• Thermostat controls, fans and heating strips• Power blocks and terminal blocks• Steel, aluminum and plywood backboards• Transformers• Interlock devices for circuit breakers• Available in steel, aluminum (raw painted or anodized) or stainless steel
construction with powder coated finish available in eight standard colors or special-ordered RAL colors
• Available for applications up to 400 amp, 120V, 208V, 240V, 277V, 480V - 1Ø or 3Ø
Applications
Available Factory-Installed Options
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
50
CP3B “ML” SeriesMain Load Center Series1Ø3 wire 120/240V or 208Y/120VApplication: remote site service for multiple loadsMilbank Main Load Center Commercial Pedestals are designed to handle the vast majority of all requirements in a standard, stocked configuration. • All units feature a load center with a plug-on, back-fed main breaker. • Load center has 16 positions for the 100 amp pedestals and 24 circuits for the 200 amp pedestals. • Both sizes include sub-feed lugs to allow feeding an external panel.
If your application requires turning loads on based on “dusk-to-dawn” requirements, be sure to see the Milbank Switched Load Center Commercial Pedestal products on the following page.
Standard PedestalsOptional Fifth Terminal Kit
Main CB Load Center Circuits
Meter Socket TypeAmp Spaces
CP3B51115A22 K3865 100 1,2 16 Ringless socket with lever bypassCP3B52119A22 K3865 200 1,2,3,4 24 Ringless socket with lever bypass
Typical Applications
Remote site service for multiple loads.
COMMERCIALPEDESTALS
Commercial PedestalsMain Load Center Series | Custom Designs Available
Features
These units include everything required for remote site service:
• NEMA 3R construction.• Expandable: load centers allow for future expansion without costly
modifications.• All units feature 200 amp meter socket with optional field installable
fifth terminal kit available.• 22K amps interrupting capacity (AIC) standard.• Optional mounting base can be embedded in concrete for fast, easy
installation.• Separate sealable and lockable utility termination section.• Separate sealable and lockable metering section.• Separate sealable and lockable customer section with a load center
for “always on” loads that include a main circuit breaker, 20 (125 or 200 amp model) or 14 (100 amp model) blank breaker spaces and a circuit directory to document configuration.
Notes
• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.
Note
All meter form and bypass options
available to meet utility requirements.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
51
Standard PedestalsOptional Fifth Terminal Kit
Main CB Contactor Amperage
Meter Socket TypeAmp Spaces
CP3B51110A22SL1 K3865 100 1,3 60 Ringless socket with lever bypassCP3B52110A22SL1 K3865 200 1,2,3,4 100 Ringless socket with lever bypass
Typical Applications
Traffic signals, parking lots, highways & athletic
field lighting
COMMERCIALPEDESTALS
Commercial PedestalsSwitched Load Center Series | Custom Designs Available
CP3B “SL” SeriesSwitched Load Center Series1Ø3 wire 120/240V or 208Y/120V
Milbank Switched Load Center Commercial Pedestals are designed not only to provide power for various loads, but also to switch specific loads on and off under certain conditions. A photoelectric cell is used for these controlled loads, and an optional time clock is also available.
Notes
• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.
Features
These units include everything required for remote site service:
• NEMA 3R construction.• Expandable: load centers allow for future expansion without costly
modifications.• All units feature 200 amp meter socket with optional field installable fifth
terminal kit available.• 22K amps interrupting capacity (AIC) standard.• Optional mounting base can be embedded in concrete for fast, easy
installation.• Separate sealable and lockable utility termination section.• Separate sealable and lockable metering section.• Separate sealable and lockable customer section with a control circuit
including PE receptacle, Lexan® window, glare shield, Hand-Off-Auto (HOA) switch, contractor controlling a 16-circuit load center for controlled loads, a pre-mounted DIN rail and pre-wired connector to add an optional “plug-and-play” time clock kit for PE on and TC off operation and a circuit directory to document configuration.
• A load center for “always on” loads that includes a main circuit breaker, a control power circuit breaker, a switched load center main breaker, nine (125 or 200 amp model) or 11 (100 amp model) blank breaker spaces and a circuit directory to document configuration.
Note
All meter form and bypass options
available to meet utility requirements.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
52COMMERCIALPEDESTALS
Commercial PedestalsCP3B “400” 400 Amp Series
Standard PedestalsOptional fifth Terminal Kit
Main CB Load Center Circuits Meter Socket Type
CP3B54120B22 K3865 2-200 amp (2) 12 circuit Ringless with lever bypassCP3B5411JB22 K3865 320 amp (400 max) 0 Ringless with lever bypass
Milbank 400 Amp Commercial Pedestals are designed to provide a weather and vandal resistant metered enclosure for various loads and distribution. Each pedestal has been designed to handle a wide range of applications using standard, stocked configurations. • Choice of a single main breaker or twin service disconnect
breakers gives flexibility to the pedestal design. • Optional distribution with feed-through lugs below the
service disconnect breakers allows the pedestal to handle numerous applications.
• Typical applications include remote homes where the metering is best located at the curb side or other remote area. The pedestal can also provide power to secondary residence, on-site business, workshop, irrigation, lighting, security or other secondary load.
• Available in custom colors to match home or landscaping.
Features
These units include everything required for remote service:• Type 3R construction• Main circuit breaker or dual service disconnects• Expandable: load center units allow for future expansion
without costly modifications• Optional mounting base can be embedded in concrete for
fast, easy installation• Separate sealable and lockable utility termination section
with lug termination• Separate sealable and lockable metering section • A separate sealable and lockable customer section with a
circuit directory and a print pocket to hold all documentation• Meter socket options include ring type with bypass studs,
ringless with heavy duty lever bypass, or K-Type bolt-on
Typical Applications
Remote site service for residential and commercial job sites.
Notes
• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.• Stud utility landing is standard. Lug kits are available from factory.
• Units with load centers have (2) #6-250 sub-feed lugs on each load center. (Each load center is 200 amp rated and UL listed with: Siemens, General Electric and Cutler-Hammer plug-in style circuit breakers.)
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
53
Features
• 3Ø4W, 480Y/277 volt• One technician can install in under an hour with use of Milbank’s pre-drilled box pad• All units are UL listed and service entrance rated• Fused disconnect with accessible handle through the deadfront• HOA and push button start• Separate accessible utility side with pre-wired landing lugs• NEMA rated starters (sizes 1-5)• Soft start units sizes 30HP-150HP• 30 amp fuse block for pivot pre-wired in the unit• White powder coated paint finish helps keep components cooler • Options include: • Hour meter • Chemical injection receptacle • Multiple injection receptacle • Multiple 30 amp fuse blocks possible
COMMERCIALPEDESTALS
Commercial PedestalsCP3B “IR” Irrigation Control Series
Standard Pedestals Exterior Cabinet NEMA Rating
CP3B0281UMWIR04 White 4CP3B0281UMWIR03 White 3CP3B0181UMWIR02 White 2
Notes
• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.
Milbank “IR” Series Irrigation Pedestals install quickly and simply – often in less than an hour with a single technician—a fraction of the time typically needed for strut farm and other installation set ups. Additionally, the pedestal comes pre-wired, so the technician simply drops in the pre-drilled concrete box pad, fastens the pedestal and runs the wires. Prewired landing lugs are provided in a separate utility side so that there is no more need to wrestle with hard-to-bend wires. Simply run the utility wire up and land on the lugs. With both the motor starter and disconnect in the same enclosure, all the controls are housed in a safe, lockable pedestal that protects against vandalism and energy theft.
Typical Applications
Power pedestal for irrigation systems or other pump control
applications.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
54COMMERCIALPEDESTALS
Commercial PedestalsCP3B “BBS” Battery Backup Series
Milbank BBS Series Commercial Pedestals are designed to provide battery backup power for various loads, and to switch specific loads on and off under certain conditions; a photoelectric cell or time clock to control lighting circuits, as an example. Metered and unmetered power distribution options are available. The back-up power pedestal is designed to handle the vast majority of todays back-up power requirements. By using 19” rack design, shelves can be adjusted to accommodate the required batteries and manufactures DC to AC inverters, transfer switches and other related equipment. This design gives the user a wide range of design and configuration options. Complete turnkey, ready to power-up pedestals are offered along with basic units ready to accept batteries and inverters supplied by others.
Features
• Type 3R construction• 100 through 320 amp meter socket with the option of
either a ring type socket (conforms to EUSERC 308) with or without test/bypass blocks or a heavy duty ringless socket with lever bypass
• Separate sealable utility termination compartment• An isolated separate customer section with service
disconnects, power distribution options and power control • 19” wide rack in customer compartment for easy layout of
equipment• Battery trays• Thermostat with cooling fan• Filtered louvers for heat rise flow through ventilation• Three point door latch (key or pad lockable)
Options
• Manual bypass switch• Transfer switch for generator
power back-up• Generator inlet receptacles 30
amp through 200 amp • Pad lockable provision for
receptacles• Police access door
• Metered load center distribution• Unmetered load center
distribution• Photo electric controls (for street
lighting)• Time clocks• HOA switches• Contactors
• GFI duplex receptacles• Thermostat for heating control• Heating pads or elements• Roll out shelves for batteries• Surge arrestors and lighting
arrestors
Typical Applications
Metered emergency uninterrupted power for traffic intersections, wireless, phone and communications equipment, parking lots,
camera and security locations
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
55COMMERCIALPEDESTALS
Commercial PedestalsCP3B “Power Transfer” Series
Milbank Power Transfer Series Pedestals provide unmetered AC power, distribution, surge suppression, mechanical interlock and stand-by generator receptacle— all in a neat, compact pedestal.
Features
• 120/240V 1Ø3W through 277/480V 3Ø4W ratings• Metered or unmetered units• Choice of EUSERC ring type or ringless meter sockets• 60 amp through 400 amp ratings • UL listed Type 3R rated• Pad lockable, isolated utility compartments• 20 amp GFI convenience receptacle• Lockable recessed generator receptacle door • Utility and generator indicator light options• All stainless steel hardware• Galvanized steel, aluminum or stainless steel cabinet
options• Custom designs available
Typical Applications
Traffic intersections, cell sites, cable TV, pump and lift stations requiring utility power with
backup generator power
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
56COMMERCIALPEDESTALS
Commercial PedestalsCP3BB “CT Metered” Series
Typical Applications
Large homes, pumping & lift stations, motor control, water treatment plants, EV charging stations, commercial buildings, large remote service
requirements, commercial and industrial control systems
Milbank CT Metered Series Commercial Pedestals are designed to be used where a smaller service package would be a better choice over large 3R rated combination switchboards. These pedestals have amperage ratings of 400 to 800 amps at voltages up through 480 volt three phase.
Features
• UL listed, freestanding Type 3R service• A low profile CT pedestal• All utility equipment is isolated in separated pad
lockable and sealable compartments • Separate customer compartment designed to hold
distribution and control equipment• Dead front customer construction• Optional mounting base• Optional construction in steel, aluminum and stainless
steel.• Wide choice of powder paint colors
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
57COMMERCIALPEDESTALS
Commercial Pedestals CP3A “Slimline” Series
Typical Applications
Roadway lighting and signage, wastewater
treatment facilities, parks and landscaping, and any application where physical
space is at a premium
Milbank Slimline Series Commercial Pedestals provide a sleeker, smaller footprint, with wireway access on the side of the unit rather than the back, allowing maximum flexibility to place the pedestal in tighter spaces.
Features• UL listed as service equipment• 100 or 200 amp• Vandal-resistant, secure and attractive design• Customer compartment with distribution and control equipment with
swing dead front door, secured with both a hasp/latch and draw latch outer door
• Utility metering compartment protected with a hinged hood, increasing resistance to meter vandalism
• Small footprint• Wireway located on left side of pedestal for utility incoming wire,
allowing pedestal to be mounted with back very close to a wall (14")• Available in 12" and 20" widths and 50" and 63" (metered) and 43"
(unmetered) heights• Includes a print pocket for plans and drawings• 200 amp main available• Voltage range: 120V–480V• Compatible with both ringless and ring type meter sockets, 4–7
terminals• Available in a wide array of colors, including but not limited too all ANSI
powder coated paint colors upon request• Pedestal mounting base option saves time and labor to install on a
cement pad—no anchor bolts required• Powder coated G90 galvanized steel, raw, anodized or powder coated
aluminum and stainless steel exterior options
“Slimline” Series Direct Bury Extension• No need for concrete• Bolts directly to unit• Easy, modular design• Ships in a smaller package• Increases project flexibility• Easier to handle and install• Utilizes stabilizer feet to prevent leaning over time• Pedestal and extension can be installed within 45 minutes
Notes
• 14 guage steel• Only available for 12” pedestals
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
58CIRCUIT
BREAKERS
Circuit BreakersUQFP Plug-In & UQFB Bolt-On Series | 120/240 VAC
UQFPUQFPH
UQFP-MUQFPH-M
200 Amp Frame | Plug-In | 10,000 AIC & 22,000 AIC | Two-Pole - Common Trip
200 Amp Frame | Bolt-On | 10,000 AIC & 22,000 AIC | Two-Pole - Common Trip
Amps10K AIC Plug-In
22K AIC Plug-In
10K AICPlug-In
22K AICPlug-In
Wire Range
CU AL
100 UQFP-100 UQFPH-100 UQFP-M-100 UQFPH-M-100 #3-#1 #1-1/0
125 UQFP-125 UQFPH-125 UQFP-M-125 UQFPH-M-125 #3-#1 #1-1/0
150 UQFP-150 UQFPH-150 UQFP-M-150 UQFPH-M-150 1/0-300 2/0-300
175 UQFP-175 UQFPH-175 UQFP-M-175 UQFPH-M-175 1/0-300 2/0-300
200 UQFP-200 UQFPH-200 UQFP-M-200 UQFPH-M-200 1/0-300 2/0-300
Amps10K AICBolt-On
22K AICBolt-On
10K AICBolt-On
22K AICBolt-On
Wire Range
CU AL
100 UQFB-100 UQFBH-100 UQFB-100-X1 UQFBH-M-100 #3-#1 #1-1/0
125 UQFB-125 UQFBH-125 UQFB-125-X1 UQFBH-M-125 #3-#1 #1-1/0
150 UQFB-150 UQFBH-150 UQFB-150-X1 UQFBH-M-150 1/0-300 2/0-300
175 UQFB-175 UQFBH-175 UQFB-175-X1 UQFBH-M-175 1/0-300 2/0-300
200 UQFB-200 UQFBH-200 UQFB-200-X1 UQFBH-M-200 1/0-300 2/0-300
Notes
• UL listed: For use with 60°C or 75°C wire.• UQFP: For parallel main circuit breaker applications.• UQFP-M: For series main circuit breaker applications. Split load tab features allow for feed-through capability.• UQFB: (2) 1/0-300 lugs provided on load and line side (cable-in, cable-out).• UQFB3: Three-pole available. Consult factory.• UQFB-X: (2) 1/0-300 lugs provided on load side and (2) line bar bus connections on line side.• UQFB-M: For series main circuit breaker applications. Split load tab features allow for feed-through capability.• UQFB-X-MOD: Replacement circuit breaker with line barriers removed.
UQFB-X1 UQFB-X UQFB UQFB-X-MOD
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
59CIRCUIT
BREAKERS
Circuit BreakersQP (small frame) and QN (large frame) | 120/240 VAC
QN2200H
Q250
QN2200RH
15–125 Amp BreakerPlug-In Type | 1” Per Pole
Amps Poles10K AIC Plug-In
22K AIC Plug-In
15 Single Q115 Q115H
15 Double Q215 Q215H
20 Single Q120 Q120H
20 Double Q220 Q220H
25 Single Q125 Q125H
25 Double Q225 Q225H
30 Single Q130 Q130H
30 Double Q230 Q230H
35 Single Q135 Q135H
35 Double Q235 Q235H
40 Single Q140 Q140H
40 Double Q240 Q240H
50 Single Q150 Q150H
50 Double Q250 Q250H
60 Single Q160 Q160H
60 Double Q260 Q260H
70 Single Q170 Q170H
70 Double Q270 Q270H
80 Double Q280 Q280H
90 Double Q290 Q290H
100 Double Q2100 Q2100H
125 Double Q2125 Q2125H
• Load connectors supplied with breakers.• UL listed for use with 60°C or 75°C wire.• Wire sizes shown are lug capacity. Consult NEC Article #310 for specific wire sizes.
Notes
200 Amp Frame | Plug-In | 10,000 AIC & 22,000 AIC | Two-Pole, Common Trip
Amps 10K AIC Plug-In 22K AIC Plug-In Handle LocationWire Range
CU AL
150 QN2150 QN2150H Left facing #4-300 #4-300
200 QN2200 QN2200H Left facing #4-300 #4-300
150 QN2150R QN2150RH Right facing #4-300 #4-300
200 QN2200R QN2200RH Right facing #4-300 #4-300
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
60 AccessoriesHubs and Closing Plates
-R
Large hub opening
-WL A7514 -YL A7515 -ZL A7516 -DL A7517 -EL A7518 -XL A7551
1" hub 11⁄4" hub 11⁄2" hub 2" hub 21⁄2" hub Small closing plate
-F A8110 -G A8111 -H A8112 -X A9064 -RRL S8324
3" hub 31⁄2" hub 4" hub Large closing plate Large hub opening adapted to small
hub oepning
-RL
Small hub opening
Notes
• Suffix: Add to catalog number for factory installation of hub.• Packaging: Individually packed units for field installation.• Abbreviations: H.O. (hub opening), C.P. (closing plate).
ACCESSORIES
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
61ACCESSORIES
AccessoriesConnector Kits, Closing Kits & Generator Interlock
Connector Kits — For Use with 3⁄8"-16 Stud Type Units Only
Closing Covers
Single Twin
Suffix Part # (3 per set) - 1Ø Suffix Part # (3 per set) - 1Ø
K1 K1539 6-350 K2 K1350 6-350
K3 K1540 4-600 or (2) 1/0-250* K2L K1350L 6-350 (non rotating)
K3L K1540L4-600 or (2) 1/0-250*
(non rotating) K4 K1541 4-600
Suffix Part # (4 per set) - 3Ø Suffix Part # (4 per set) - 3Ø
K5 K3082 6-350 K6 K3442 6-350
K7 K3441 4-600 or (2) 1/0-250* K8 K3083 4-600
Meter Closing Plate(Ring Type/Ringless)
Metal Closing Plate(For Ringless Sockets)
6003 - Grey Plastic CP-21
6116 - Clear Plastic
K8180 (sold in pairs)
K5815 - large QN with small frame Q
K5820 - large frame QN with large frame QN
K5830 - small frame Q to small frame Q
Bypass Link
Generator Interlock
A-GPK3235
Suitable for use with pedestals for extra support
S2291-TO
K4802
M5-144
Do not use with lever bypass
sockets
Touch-Up PaintStake KitPedestal Raceway Anti-Inversion Clip
Disconnect Sleeve
Note
Consult factory for proper connector kits for studded meter sockets.
*For (2) 1/0-250, conductors must be of same size.
PED
Grade Line
10”
24”
54”
18”
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
62ACCESORIES
AccessoriesFifth Terminals, Tap Connectors & Block Assemblies
K1190 (For factory installed triplex ground, add suffix -TG to catalog number)
Fifth Terminals
Tap Connectors (3 per set)
100 Amp Blocks (single sockets only) 200 Amp Blocks (single sockets only)
5T8K2 - 100-200 Amp“Plug-In”
K5T - 200 Amp (Block with Square Hole)
K3865 - Heavy Duty Jaw Clamping (K3866 without Neutral Wire)
Replaces the load or line side slide-in nut assembly on Milbank 200 amp sockets. Allows for a 100 amp tap location in addition to the #6-350 kcmil load-side connector. K5022 includes safety barrier extensions for applications over 300 VAC. Three lugs per kit.
K4977-INT - Internal Hex
K4977-EXT - External Hex
K5022-INT - Internal Hex (set of 4 w/ barrier)
BL7474 - Block Assembly
BL7499 - Horn Bypass Block Assembly
Z904486-AO - Slotted Nut Assembly
Z903274-AO - Horn Bypass Nut Assembly
Z802965-AC - Neutral without Nut
Z901925-AC - Hex Nut Set Screw
K4527 - Internal Hex Block Assembly (w/ meter support)
K4528 - External Hex Block Assembly (w/ meter support)
K4529 - Internal Hex Horn Bypass Block Assembly (w/ meter support)
K4530 - External Hex Horn Bypass Block Assembly (w/ meter support)
Z916265-AO - Internal Nut Assembly
Z916264-AO - External Nut Assembly
Z814898-AC - Neutral without Nut
Triplex Ground
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
63COMMERCIAL& INDUSTRIALENCLOSURES
Commercial & Industrial Enclosures
NEMA Commercial Enclosures
Milbank’s line of commercial enclosures includes the full gamut of styles and sizes; everything from junction boxes to transformer cabinets, telephone cabinets to wireway.
Type 1 EnclosuresMilbank’s Type 1 enclosures are designed for indoor use to provide a degree of protection to personnel against access to hazardous parts and to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects, such as falling dirt.
Type 3R EnclosuresMilbank’s Type 3R enclosures are designed for either indoor or outdoor use to provide a degree of protection from harmful effects on the equipment due to the ingress of water (rain, sleet, snow) and that will be undamaged by the external formation of ice on the enclosure.
WirewayMilbank’s wide range of wireway is available in many styles and sizes and its wide range of fittings allows it to smoothly transition to and from competitors’ products.
NEMA Industrial Enclosures
Milbank’s line of industrial enclosures include junction boxes, wiring trough, push-button enclosures and modular enclosures. Milbank also excels in special designs; nearly any type, size or color of enclosure you need, we can make!
Type 12 EnclosuresEnclosures constructed without knockouts for indoor use to provide a degree of protection to personnel against access to hazardous parts, and protect components against falling dirt, circulating dust and lint, and dripping or splashing water.
Type 4 EnclosuresEnclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; protect equipment against falling dirt and windblown dust; protect against rain, sleet, snow, splashing water, and hose directed water; and is resistant to damage by the external formation of ice on the enclosure.
Industrial Enclosure SpecialsMilbank specializes in custom enclosure projects, offering an almost limitless amount of styles, options, colors and sizes. Milbank will meet your needs and specifications and deliver a custom enclosure that protects your crucial electric equipment.
Thermal ManagementProtect components housed in enclosures from damage caused by overheating, freezing, humidity and condensation with these thermal management products.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
64WATTHOUR
METER FORMS
Watthour Meter FormsStandard Forms | Transformer Rated or Self-Contained
SC SC TR TR TR
TR SC SC SC SC
TR TR SC SC TR
TR TR SC SC TR
TR TR TR
2 and 3-WIRE FORMS1S & 2S
2 and 3-WIRE FORMS1S & 2S with BYPASS
2-WIRE FORM 3S5th Term. 9 o’clock
2-WIRE FORM 3Swith BYPASS
2-WIRE FORM 3S5th Term. 6 o’clock
2-WIRE FORM 3Swith BYPASS
2 ELEMENT3-WIRE NETWORK
FORM 12S 5thTERM. 9 o’clock
2 ELEMENT 3-WIRENETWORK FORM 12S
with BYPASS5th Term. 9 o’clock
2 ELEMENT 3-WIRENETWORK FORM 12S
with BYPASS5th Term. 6 o’clock
2 ELEMENT3-WIRE NETWORK
FORM 12S 5thTERM. 6 o’clock
3-WIRE FORM 4S 3-WIRE FORM 4SWITH BYPASS
2 or 3 ELEMENT3Ø4W Y or
Y FORM 14SFORM 15S
Y FORM 16S
2 or 3 ELEMENT3Ø4W Y or
FORMS 14S & 15Swith BYPASS
2 ELEMENT3Ø4W Y orY FORM 7SFORM 24S
with BYPASS
2 ELEMENT2Ø3W, 2Ø4W, 3Ø3W
FORM 5S
2 ELEMENT Ø3W,2Ø4W, 3Ø3W FORM 5S with
BYPASS
2 ELEMENT2Ø3W, 2Ø4W, 3Ø3W
FORM 13S
2 or 3 ELEMENT2Ø3W, 2Ø4W, 3Ø3W
FORM 13S withBYPASS
2 or 3 ELEMENT3Ø4W Y orY FORM 9SFORM 8S
2 or 3 ELEMENT3Ø4W Y or
FORMS 8S & 9SFORMS 8S & 9S
with BYPASS
2 ELEMENT3Ø4W YFORM 6S
2 ELEMENT3Ø4W YFORM 6S
with BYPASS
TR = TRANSFORMER RATEDSC = SELF CONTAINED
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
65METERFORMS
Meter FormsReference Information
++
ILINE (BONDED)N
C.T.LOAD
2 ++
DIAGRAM D
P1 P2 C+1 C2C+
2PN C1
C.T.
DIAGRAM D1∅3W or 3W Network with 2 C.T.’s
2 Stator Meter - Form 5S8T Socket, Test Switch #TS07-0105
++
1LINE
C.T.LOAD2
P1 C+1
++
3
++
PT PT
DIAGRAM E
P3 P2 C1 C+3 C3
C.T.
DIAGRAM E3∅3W “∆” with 2 P.T.’s & 2 C.T.’s
2 Stator Meter - Form 5S8T Socket, Test Switch #TS07-0105
++
1LINE
C.T.LOAD2
P1 C+1
++
3
DIAGRAM F
P3 P2 C1 C+3 C3
C.T.
DIAGRAM F3∅3W “∆” with 2 C.T.’s2 Stator Meter - Form 5S
8T Socket, Test Switch #TS07-0105
+
+
C.T.LOAD
P1
+
+
P3 PN C+ C+
C.T.
C.T.
++
(BONDED)
DIAGRAM G
C C C+ C
1
LINE23N
DIAGRAM G3∅4W “Y” with 3 C.T.’s
2 1⁄2 Stator Meter - Form 6S13T Socket, Test Switch #TS10-0109
+
+
1
LINE
C.T.LOAD2
P1
+
+3
P3 PN C+
N
C.T.
C.T.
++
(BONDED)
+ +
PTPT
+ +
DIAGRAM H
C C+C+ CC
DIAGRAM H3∅4W “Y” with 2 P.T.’s & 3 C.T.’s
2 1⁄2 Stator Meter - Form 6S13T Socket, Test Switch #TS10-0109
+
+
1
LINE
C.T.LOAD2
P1
+
+3
P3 PN C+
N
C.T.
C.T.
++
(BONDED)
P2
DIAGRAM I
C C+ C C+ C
DIAGRAM I3∅4W “Y” or “∆” with 3 C.T.’s“Y” 3 Stator Meter - Form 9S“∆” 2 Stator Meter - Form 8S
13T Socket, Test Switch #TS10-0109
+
+
1
LINE
C.T.LOAD2
P1
+
+3
PN C+
N
C.T.
C.T.
+
+
(BONDED)
+ +PT PT
++
P3
PT
+ +
DIAGRAM J
P2 C C+ C C+ C
DIAGRAM J3∅4W “Y” with 3 P.T.’s & 3 C.T.’s
3 Stator Meter - Form 9S13T Socket, Test Switch #TS10-0109
DIAGRAM A
(ALT.LOC.)
++
+
+
ILINE
(BONDED)N C.T. LOAD
P1 PN C+1 C1
P.T.
DIAGRAM A1∅2W with 1 P.T. & 1 C.T.
Single Stator Meter(2W1∅) - Form 3S5T Socket, Test Switch #TS04-0101
(ALT.LOC.)
++I
LINE
(BONDED)N C.T.
LOAD2
DIAGRAM B
P1 PN C+1 C1
DIAGRAM B1∅3W with 1 C.T.
Single Stator Meter (2W1∅) - Form 3S5T Socket, Test Switch #TS04-0101
++
ILINE (BONDED)N
C.T.LOAD
2
P1 P2 C+1 C+
2 C2C+2
++
DIAGRAM C
C.T.
DIAGRAM C1∅3W with 2 C.T.’s
Single Stator Meter (3W1∅) - Form 4S6T Socket, Test Switch #TS07-0105
Prewiring: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
66
This table is for concentric stranded conductors only. For cables with compact conductors refer to NEC. Refer to latest NEC Code or Local Codes for updated requirements.
TypeConductor Size
(AWG/kcmil)Conduit Trade Sizes (Inches)
1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4
THHN,THWN,THWN-2
12 9 16 26 46 62 102 146 225 301 387
10 6 10 17 29 39 64 92 142 189 244
8 3 6 9 16 22 37 53 82 109 140
6 2 4 4 12 16 27 38 59 79 101
4 1 2 4 7 10 16 23 36 48 62
3 1 1 3 6 8 14 20 31 41 53
2 1 1 3 5 7 11 19 26 34 44
1 1 1 1 4 5 8 12 19 25 35
1/0 1 1 1 3 4 7 10 16 21 27
2/0 0 1 1 2 3 6 8 13 18 23
3/0 0 1 1 1 3 5 7 11 15 19
4/0 0 1 1 1 2 4 6 9 12 16
XHH,XHHW,XHHW-2
4 1 2 4 7 10 16 24 37 49 63
2 1 1 3 5 7 12 17 26 35 45
1/0 1 1 1 3 4 7 10 16 22 28
2/0 0 1 1 2 3 6 9 13 18 23
4/0 0 1 1 1 2 4 6 9 12 16
250 0 0 1 1 1 3 5 7 10 13
350 0 0 1 1 1 2 3 6 7 10
500 0 0 0 1 1 1 2 4 5 7
750 0 0 0 0 1 1 1 3 4 5
MAXIMUM NUMBER OF CONDUCTORS IN CONDUITTable from 2008 NEC Code Reference: Rigid Metal Conduit
Conduit, Ampacity & SCCRReference Information
CONDUIT, AMPACITY &
SCCR
CATALOG NUMBERS U5952 & U5953100A MAXIMUM, 120/240 VAC SINGLE PHASE, THREE WIRE
RAINPROOF NEMA TYPE 3R
SHORT CIRCUIT CURRENT RATING IS 10,000 RMS SYMMETRICAL AMPERE AT 240 VACMAXIMUM, BUT IS LIMITED TO THE LOWEST SHORT CIRCUIT CURRENT RATING OF ANYINSTALLED CIRCUIT BREAKER. WATTHOUR METER NOT INCLUDED IN SHORT CIRCUITCURRENT RATING. REPLACEMENT CIRCUIT BREAKER MUST BE THE SAME TYPE AND
RATING. USE SIEMENS QP, QT; CUTLER-HAMMER QP, BD, BR;SQUARE D HOMELINE; G.E. TQ, THQ, THQL.
SUITABLE FOR USE ASRECREATIONAL VEHICLE SITE
SUPPLY EQUIPMENT
UNDERGROUND FEED ONLY
ONTRIPOFF
TO RESETBREAKER MOVE TO
“OFF” THEN TO “ON”
DANGERHAZARD OF ELECTRICAL
SHOCK OR BURN
TURN OFF POWER
SUPPLYING THIS EQUIPMENTBEFORE WORKING INSIDE
SIZE OF FIELD INSTALLEDCONDUCTORS SHALL BE
60° OR 75°C SIZED TO 60°CRATING FOR 110 AMPS ORLESS AND 75°C SIZED TO75°C FOR 125 AMPS AND
ABOVE
SHIPPING TENDS TO LOOSEN BOLTED
CONNECTIONS. CHECKAND TIGHTEN ALL
HARDWARE BEFORE ENERGIZING UNIT
LINE LINE
GROUNDLOADNEUTRAL
LINENEUTRAL
WIRE TERMINAL INFORMATION USE AL-CU CONDUCTORS
TERMINAL WIRE RANGE TORQUE LB-IN
LINE AND LINE NEUTRAL 350 KCMIL - #6
2/0 AWG -#14 AWGGROUND CONNECTOR
LOAD NEUTRAL (LARGESLOTTED HEAD HOLE)
LOAD NEUTRAL (SMALLSLOTTED HEAD HOLE)
250
120
35404550
202535
14 - 108
6 - 43 - 1/0
14 - 1086
SAMPLE RATING LABEL
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
67ENERGIZATIONOF ELECTRICAL
EQUIPMENT
Energization of Electrical EquipmentImportant Information for Installers
Before EnergizingA. Give equipment a thorough visual examination to determine that: 1) No shipping or installation damage exists. 2) Proper clearances have been maintained. 3) All connections have been made. 4) Equipment is clean and dry.B. Make a thorough examination to: 1) Verify tightness of all bolted connections (see table below). 2) Manually operate all circuit breakers, switches, relays, etc. 3) Check rigidity of all mountings, bus bars and components. 4) Use test equipment to check continuity of circuitry and integrity of insulation.C. All switches and circuit breakers should be in the “off” position.D. Verify that manual meter bypass (if applicable) is in non-bypass position.E. Install cover and/or close doors.F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These steps will secure the installation in case of accidental energization.
When EnergizingA. Use caution and follow established safety procedures: 1) Wear safety apparel. 2) Use safety equipment. 3) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it.
After EnergizingA. Secure the installation: 1) To prevent accidental contact with energized parts, cover all openings with approved filler devices. 2) To prevent unauthorized access, secure all covers and/or doors with approved security devices. 3) Attach/post information to advise others of potential hazards associated with the installation.
Important NoteIn addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment.
*Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first.CU: CopperAL: Aluminum
Nominal Size
Joint DescriptionHead Type
Torque(Inch Lbs.)Screw Nut
10 Brass Brass Nut or Extruded Hole All 20-25 inch lbs.
10 Steel Copper or Aluminum Busbar ≤ 1/8" All 25-30 inch lbs.
10 Steel Steel Nut or Extruded Hole; CU or AL Busbar > 1/8" All 30-35 inch lbs.
12 Steel Aluminum Extruded Hole All 30-35 inch lbs.
12 Steel Steel Nut or Extruded Hole All 40-50 inch lbs.
1/4 Steel Aluminum Extruded Hole All 40-50 inch lbs.
1/4 Steel Steel Nut or Extruded Hole; CU or AL Busbar All 50-60 inch lbs.
5/16 Steel Aluminum Extruded Hole Hex 60-70 inch lbs.
5/16 Steel Steel Nut or Extruded Hole; CU or AL Busbar Hex 100-150 inch lbs.
3/8 Steel Steel Nut Hex 150-200 inch lbs.
1/2 Steel Steel Nut Hex 200-250 inch lbs.
Recommended Torque for General Applications*
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
68MATERIALS& FINISHES
Materials & FinishesReference Information
Materials
Finish
Ratings & Compliance
The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute.
Steel Quality
16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. (AISI G90)14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.
Steel Sheet
Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire.Bus Bar: Alloy; 6101-O & 6063-O
Aluminum Extrusion
3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064–.125
Aluminum Sheet
Electrolytic copper with tin plating in most applications.
Copper Sheet & Bus
• In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds.
• Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds.
• Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers.
Insulating Materials
Light gray state-of-the-art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory.
Process
Zinc-coated with a chromate dip.
Metal Fastners
All Milbank electrical enclosures in this catalog are rated “Type 3R Enclosure” unless specified otherwise on the product’s page. All enclosures with a UL designation are constructed per the appropriate UL Standard and may be installed per the National Electric Code. UL procedure files associated with the UL Standards are listed as follows: Meter Sockets (UL 414, File E30202), Test Switches (UL 414, File E62531), Power Outlets (UL 231, File E90945), Panelboards (UL 67, File E32628) and Pullout Switches (UL 1429, File E133062). Additional standards are utilized as applicable: Meter Sockets (ANSI C12.7), Test Switches (ANSI C12.9) and Panelboards (NEMA PB-1).
Ratings & Compliance
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
69Utility Approvals Chart
CatalogNumber
AlliantEnergy
WeEnergies
Wisconsin Public Service
Madison Gasand Electric
PageNumber
L572-XL-KK X X X X 19L573-XL-KK X X X X 19L574-XL-KK X X X X 19L575-XL-KK X X X X 19L576-XL-KK X X X X 19
NU8980-O-200-KK X X X 34NU8980-O-200-KK-LP X X X 34
NU8980-O-KK X X X 34NU8980-O-KK-LP X X X 34
NU8980-O-SF100-KK X X X 34NU8980-O-SF100-KK-LP X X X 34
S9995-B-XL X X 42S9996-B-XL X X 42S9997-B-XL X X 42
SDRCW X X X 42SDRCW X X X 42
U1211-RXL X X X 10U1252-X-KK X X X X 22
U1252-X-KK-K1-PED X X X 22U1253-X-KK X X X X 22
U1253-X-KK-K3-PED X X X 22U1254-X-KK X X X X 22
U1254-X-KK-K3-PED X X X 22U1255-X-KK-K4-PED X X X 22
U1256-X-KK-PED X X X 22U1748-O-5T9-WI X 41
U1748-O-WI X X X X 41U1773-XL-TG-KK X X X X 8
U1779-RRL-5T9-K3 OH only X 13U1779-RRL-K3 X 13U1783-O-KK X X X X 31U2120-X-K7 X 14U2594-X-K7 X 14
U2692-XL-KK X X X 21U2732-XT-PED X X Call for approval 25U2733-XT-PED X X Call for approval 25U2734-XT-PED X X Call for approval 25U2735-XT-PED X X Call for approval 25U2736-XT-PED X X Call for approval 25
U2872-XT X X Call for approval 24U2872-XT-5T9-K3 X Call for approval 24
U2872-XT-K3 X Call for approval 24U2873-XT X X Call for approval 24
U2873-XT-K3 X Call for approval 24U2874-XT X X Call for approval 24
U2874-XT-K3 X Call for approval 24U3000-O-5T9-K3L-K2L X 13
U3000-O-K3L X 13U3000-O-K3L-K2L X 13
U3358-O-KK X X X X 31
UTILITYAPPROVALS
CHART
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
70 Utility Approvals Chart
CatalogNumber
AlliantEnergy
WeEnergies
Wisconsin Public Service
Madison Gasand Electric
PageNumber
U3849-O-2/150 X X 39U3849-O-2/200 X X X 39
U3849-O-200/100 X X 39U3850-O-TG-KK X 9
U4322-O-5T9 Call for approval Call for approval 38U4323-O-5T9 Call for approval 38
U4329-O X X X 41U4363-X-QG X X OH approved only 13
U4664-X-8502 X 43U4664-X-8507 X 43U4664-XT-9507 X 43U4667-X-8013 X 44U4667-X-8512 X 44U4667-XT-9504 X 44U4667-XT-9506 X 44
U4701-XL X X 12U4724-O X 33
U4724-O-5T9 X X 33U4801-XL X 10
U4801-XL-5T9 X 10U5136-O-100S X X X X 36U5136-O-150S X X X X 36U5136-O-200S X X X X 36U5137-O-100S X X X X 36U5137-O-150S X X X X 36U5137-O-200S X X X X 36
U5168-XTL-100-KK X X X X 16U5168-XTL-200-KK X X X X 16
U5701-0-100S X 38U5701-0-150S X 38U5701-0-200S X 38
U5706-O-200S-KK X 37U5767-X-200-TF X 17U5787-O-200-TF X 17U5842-RL-100-KK X X X 15U5842-RL-200-KK X X X 15
U5844-PXL-200-KK Call for approval 15U5882-X-KK-K1 X X 27
U5882-X-KK-K1-PED X X X 27U5883-X-KK-K1 X X 27
U5883-X-KK-K1-PED X X X 27U5884-X-KK-K1 X X 27
U5884-X-KK-K1-PED X X X 27U5885-X-KK-K1 X X 27
U5885-X-KK-K1-PED X X X 27U5886-X-KK-K1 X X 27
U5886-X-KK-K1-PED X X X 27U5902-X-KK-K1 X X 27
U5902-X-KK-K1-PED X X X 27U5903-X-KK-K1 X X 27
UTILITYAPPROVALS
CHART
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
71Utility Approvals ChartUTILITY
APPROVALSCHART
CatalogNumber
AlliantEnergy
WeEnergies
Wisconsin Public Service
Madison Gasand Electric
PageNumber
U5903-X-KK-K1-PED X X X 27U5904-X-KK-K1 X X 27
U5904-X-KK-K1-PED X X X 27U5905-X-KK-K1 X X 27
U5905-X-KK-K1-PED X X X 27U5906-X-KK-K1 X X 27
U5906-X-KK-K1-PED X X X 27U5925-O-100-KK X 35U5925-O-150-KK X 35U5925-O-200-KK X 35
U7362-RL-KK X X X X 20U7363-RL-KK X X X X 20U7364-RL-KK X X X X 20U7365-RL-KK X X X X 20U7366-RL-KK X X X X 20U7375-RL-KK X X 15
U7421-RL X X 12U7423-XL X X 12
U7487-RL-TG-KK X X X 7U7573-RL X X 8
U8032-XL-KK X X X X 18U8033-XL-KK X X X X 18U8034-XL-KK X X X X 18U8035-XL-KK X X X X 18U8036-XL-KK X X X X 18U8624-RXL X X 11U9107-O X X 32
U9107-O-WI X XU9108-O X X X 32
U9320-RXL X X 8U9550-DL X X X 11U9551-O X X X 11
U9700-RRL X X X 12U9701-RXL X X X X 12UC1962-XL X X X 29UC2427-XL X X 30UC2428-XL X X 30UC3887-XL X X X 29UC3889-XL X X X 29UC7448-XL X X X X 29UC7449-XL X X X 29UC7532-XL X X X 29
WS X X X 42
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in
specifications and features shown without notice or obligation.
72
6003.................................... 616116.................................... 61 U5268-XTL-100-KK ............ 165T8K2 ................................. 62A7514 ................................. 60A7515 ................................. 60A7516 ................................. 60A7517 ................................. 60A7518 ................................. 60A7551 ................................. 60A8110 ................................. 60A8111 ................................. 60A8112 ................................. 60A9064 ................................. 60A-GP ................................... 61BL7474 ............................... 62BL7499 ............................... 62CP-21 .................................. 61K1350 ................................. 61K1350L ............................... 61K1539 ................................. 61K1540 ................................. 61K1540L ............................... 61K1541 ................................. 61K1990 ................................. 62K3082 ................................. 61K3083 ................................. 61K3235 ................................. 61K3441 ................................. 61K3442 ................................. 61K3865 ................................. 62K3866 ................................. 62K4527 ................................. 62K4528 ................................. 62K4529 ................................. 62K4530 ................................. 62K4802 ................................. 61K4977-EXT .......................... 62K4977-INT .......................... 62K5022-INT .......................... 62K5815 ................................. 61K5820 ................................. 61K5830 ................................. 61K5T ..................................... 62K8180 ................................. 61L572-XL-KK ......................... 19L573-XL-KK ......................... 19L574-XL-KK ......................... 19
L575-XL-KK ......................... 19L576-XL-KK ......................... 19M5-144 ............................... 61NU8980-O-200-KK ............. 34NU8980-O-200-KK-LP ........ 34NU8980-O-KK .................... 34NU8980-O-KK-LP ............... 34NU8980-O-SF100-KK ......... 34NU8980-O-SF100-KK-LP .... 34Q115................................... 59Q115H ................................ 59Q120................................... 59Q120H ................................ 59Q125................................... 59Q125H ................................ 59Q130................................... 59Q130H ................................ 59Q135................................... 59Q135H ................................ 59Q140................................... 59Q140H ................................ 59Q150................................... 59Q150H ................................ 59Q160................................... 59Q160H ................................ 59Q170................................... 59Q170H ................................ 59Q2100................................. 59Q2100H .............................. 59Q2125................................. 59Q2125H .............................. 59Q215................................... 59Q215H ................................ 59Q220................................... 59Q220H ................................ 59Q225................................... 59Q225H ................................ 59Q230................................... 59Q230H ................................ 59Q235................................... 59Q235H ................................ 59Q240................................... 59Q240H ................................ 59Q250................................... 59Q250H ................................ 59Q260................................... 59Q260H ................................ 59Q270................................... 59
Q270H ................................ 59Q280................................... 59Q280H ................................ 59Q290................................... 59Q290H ................................ 59QN2150 .............................. 59QN2150H ........................... 59QN2150R ............................ 59QN2150RH ......................... 59QN2200 .............................. 59QN2200H ........................... 59QN2200R ............................ 59QN2200RH ......................... 59S2291-TO ........................... 61S8324.................................. 60S9995-B-XL ......................... 43S9996-B-XL ......................... 43S9997-B-XL ......................... 43U1211-RXL .......................... 10U1252-X-KK ........................ 22U1252-X-KK-K1-PED .......... 22U1253-X-KK ........................ 22U1253-X-KK-K3-PED .......... 22U1254-X-KK ........................ 22U1254-X-KK-K3-PED .......... 22U1255-X-KK-K4-PED .......... 22U1256-X-KK-PED ................ 22U1748-O-5T9-WI ................ 41U1748-O-WI ....................... 41U1773-XL-TG-KK .................. 8U1779-RRL-5T9-K3 ............. 13U1779-RRL-K3 .................... 13U1783-O-KK ....................... 31U2120-X-K7 ........................ 14U2594-X-K7 ........................ 14U2692-XL-KK ...................... 21U2732-XT-PED .................... 25U2732-XT-PED-K7 .............. 25U2733-XT-PED .................... 25U2733-XT-PED-K7 .............. 25U2734-XT-PED .................... 25U2734-XT-PED-K7 .............. 25U2735-XT-PED .................... 25U2735-XT-PED-K7 .............. 25U2736-XT-PED .................... 25U2736-XT-PED-K7 .............. 25U2872-XT ............................ 24U2872-XT-5T9-K3 ............... 24
U2872-XT-K3 ....................... 24U2873-XT ............................ 24U2873-XT-K3 ....................... 24U2874-XT ............................ 24U2874-XT-K3 ....................... 24U3000-O-5T9-K3L-K2L ....... 13U3000-O-K3L ...................... 13U3000-O-K3L-K2L .............. 13U3358-O-KK ....................... 31U3802 ................................... 4U3812 ................................... 4U3822-20GWR ...................... 5U3832 ................................... 4U3849-O-2/150 .................. 40U3849-O-2/200 .................. 40U3849-O-200-100 .............. 40U3850-O-TG-KK ................... 8U3862 ................................... 4U4322-O-5T9 ...................... 39U4323-O-5T9 ...................... 39U4329-O ............................. 42U4363-X-QG ....................... 13U4664-X-8502 .................... 44U4664-X-8507 .................... 44U4664-XT-9507 ................... 44U4667-X-8013 .................... 45U4667-X-8512 .................... 45U4667-XT-9504 ................... 45U4667-XT-9506 ................... 45U4701-XL ............................ 12U4724-O ............................. 33U4724-O-5T9 ...................... 33U4801-XL ............................ 10U4801-XL-5T9 ..................... 10U4881-O ............................... 6U4881-O-50GB ..................... 6U4881-O-60GB ..................... 6U5136-O-100S .................... 36U5136-O-150S .................... 36U5136-O-200S .................... 36U5137-O-100S .................... 36U5137-O-150S .................... 36U5137-O-200S .................... 36U5168-XTL-100-KK ............. 16U5168-XTL-200-KK ............. 16U5268-XTL-200-KK ............. 16U5701-0-100S ..................... 38U5701-0-150S ..................... 38
IndexINDEX
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
73INDEX
U5701-0-200S ..................... 38U5706-O-200S-KK .............. 37U5767-O-200-CB ................ 17U5767-X-200-CB ................ 17U5767-X-200-TF ................. 17U5787-O-200-TF ................ 17U5842-RL-100-KK ............... 15U5842-RL-200-KK ............... 15U5844-PXL-200-KK ............. 15U5882-X-KK-K1-PED .......... 27U5883-X-KK-K1-PED .......... 27U5884-X-KK-K1-PED .......... 27U5885-X-KK-K1-PED .......... 27U5886-X-KK-K1-PED .......... 27U5902-X-KK-K1-PED .......... 27U5903-X-KK-K1-PED .......... 27U5904-X-KK-K1-PED .......... 27U5905-X-KK-K1-PED .......... 27U5906-X-KK-K1-PED .......... 27U5925-O-100-KK ................ 35U5925-O-150-KK ................ 35U5925-O-200-KK ................ 35U6221-O-100-10GR ............ 35U6221-O-200-10GR ............ 35U7362-RL-KK ...................... 20U7363-RL-KK ...................... 20U7364-RL-KK ...................... 20U7365-RL-KK ...................... 20U7366-RL-KK ...................... 20U7375-RL-KK ...................... 15U7421-RL ............................ 12U7423-XL ............................ 12U7487-RL-TG-KK .................. 7U7573-RL .............................. 9U8032-XL-KK ...................... 18U8033-XL-KK ...................... 18U8034-XL-KK ...................... 18U8035-XL-KK ...................... 18U8036-XL-KK ...................... 18U8624-RXL .......................... 11U9107-O-CECHA ............... 32U9107-O-WI ....................... 32U9108-O-WI ....................... 32U9320-RXL ............................ 9U9550-DL ........................... 11U9551-O ............................. 11U9700-RRL .......................... 12U9701-RXL .......................... 12
UC1290-RL ......................... 29UC1299-RL ......................... 29UC2427-XL ......................... 30UC2428-XL ......................... 30UC3887-XL ......................... 29UC3889-XL ......................... 29UC7448-XL ......................... 29UC7449-XL ......................... 29UC7532-XL ......................... 29UQFB-100 ........................... 58UQFB-100-X1 ..................... 58UQFB-125 ........................... 58UQFB-125-X1 ..................... 58UQFB-150 ........................... 58UQFB-150-X1 ..................... 58UQFB-175 ........................... 58UQFB-175-X1 ..................... 58UQFB-200 ........................... 58UQFB-200-X1 ..................... 58UQFBH-100 ........................ 58UQFBH-125 ........................ 58UQFBH-150 ........................ 58UQFBH-175 ........................ 58UQFBH-200 ........................ 58UQFBH-M-100 .................... 58UQFBH-M-125 .................... 58UQFBH-M-150 .................... 58UQFBH-M-175 .................... 58UQFBH-M-200 .................... 58UQFP-100 ........................... 58UQFP-125 ........................... 58UQFP-150 ........................... 58UQFP-175 ........................... 58UQFP-200 ........................... 58UQFPH-100 ........................ 58UQFPH-125 ........................ 58UQFPH-150 ........................ 58UQFPH-175 ........................ 58UQFPH-200 ........................ 58UQFPH-M-100 .................... 58UQFPH-M-125 .................... 58UQFPH-M-150 .................... 58UQFPH-M-175 .................... 58UQFPH-M-200 .................... 58UQFP-M-100 ...................... 58UQFP-M-125 ...................... 58UQFP-M-150 ...................... 58UQFP-M-175 ...................... 58
UQFP-M-200 ...................... 58Z703916-AC ....................... 47Z703917-AC ....................... 46Z703917-AC ....................... 47Z703918-AC ....................... 46Z703918-AC ....................... 47Z703919-AC ....................... 46Z703919-AC ....................... 47Z703921-AC ....................... 47Z704693-AC ....................... 46Z704693-AC ....................... 47Z704694-AC ....................... 46Z704694-AC ....................... 47Z705420-AC ....................... 46Z705420-AC ....................... 47Z705456-AC ....................... 46Z705456-AC ....................... 47Z708145-AC ....................... 47Z802965-AC ....................... 62Z844898-AC ....................... 62Z901925-AC ....................... 62Z903274-AO ....................... 62Z904486-AO ....................... 62Z916264-AO ....................... 62Z916265-AO ....................... 62
Index
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com WISCONSIN 7/18