wmahm & wmahv ah.01.pdf · 2011. 4. 27. · product specifications modular ah.01 4/11 cooling...

10
P RODUCT S PECIFICATIONS Modular AH.01 www.whirlpoolcomfort.com 4/11 COOLING CAPACITY: 18,000 - 60,000 BTU/H WMAHM & WMAHV VARIABLE AND MULTI-SPEED MODULAR BLOWERS Standard Features WMAHM is a multi-speed blower — motor speed is easily changed • WMAHV has a variable-speed ECM™ blower motor • Cooling or heat pump applications: upflow, down- flow, and horizontal applications WMAHM control board includes a fan delay in cool- ing mode and is isolated from the air stream WCC & WCH coils are equipped with a check flow- rater • Cooling and Heat Pump Applications • ARI Certified • ETL Listed Cabinet Features • Painted, galvanized steel cabinet • Blower section usable as an electric furnace • Uses HKR Electric Heat Kits • Intended for use with cased evaporator coils (WCC & WCH) and condensing units or heat pumps Foil-faced insulation is glued in place and covers the entire blower case to reduce operating sound and cabinet condensation Bottom flanges formed inwardly for additional strength and to provide a good mounting surface for a cased-coil section to form a two-piece blower coil The Whirlpool ® WMAHM & WMAHV Modular Blowers are tailor-made for exceptional energy efficiency. When matched with our cased coils for upflow, downflow, and horizontal applications, these two-piece blowers increase both installation and application flexibility. * To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. Full warranty details are available at www.whirlpoolhvac.com.

Upload: others

Post on 26-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • PRODUCT SPECIFICATIONS

    Modular AH.01 www.whirlpoolcomfort.com 4/11

    COOLING CAPACITY:18,000 - 60,000 BTU/H

    WMAHM & WMAHVVARIABLE AND MULTI-SPEED

    MODULAR BLOWERS

    Standard Features• WMAHM is a multi-speed blower — motor speed

    is easily changed• WMAHV has a variable-speed ECM™ blower motor• Cooling or heat pump applications: upfl ow, down-

    fl ow, and horizontal applications• WMAHM control board includes a fan delay in cool-

    ing mode and is isolated from the air stream• WCC & WCH coils are equipped with a check fl ow-

    rater• Cooling and Heat Pump Applications• ARI Certifi ed• ETL Listed

    Cabinet Features• Painted, galvanized steel cabinet• Blower section usable as an electric furnace• Uses HKR Electric Heat Kits• Intended for use with cased evaporator coils

    (WCC & WCH) and condensing units or heat pumps• Foil-faced insulation is glued in place and covers the

    entire blower case to reduce operating sound and cabinet condensation

    • Bottom fl anges formed inwardly for additional strength and to provide a good mounting surface for a cased-coil section to form a two-piece blower coil

    The Whirlpool® WMAHM & WMAHV Modular Blowers are tailor-made for exceptional energy effi ciency. When matched with our cased coils for upfl ow, downfl ow, and horizontal applications, these two-piece blowers increase both installation and application fl exibility.

    * To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or

    Québec. Full warranty details are available at www.whirlpoolhvac.com.

  • PRODUCT SPECIFICATIONS

    2 www.whirlpoolcomfort.com Modular AH.01

    Design SeriesMAH Modular Air Handler

    ElectricalA 208-230/60/1

    Motor Speed

    Revisions

    V Variable Speed

    A First Series

    M Constant Speed

    Circuit Breaker

    Airflow Delivered

    A No Circuit Breaker

    08 800 CFM

    B Circuit Breaker

    12 1200 CFM16 1600 CFM

    Factory-installed Electric Heat

    20 2000 CFM

    00 No Heat

    11

    AM

    52,3,4

    AMAH

    BrandW Whirlpool

    1

    W

    12

    12

    6,7

    00

    8,9

    A

    10

    NOMENCLATURE

    W" D" H"

    MBE1200 1,200 to 600 3, 5, 6, 8, 10, 15 208/230-1 17½ 21 26 72

    MBE1600 1,600 to 1,200 3, 5, 6, 8, 10, 15 208/230-1 21 21 30 82

    MBE2000 2,000 to 1,200 3, 5, 6, 8, 10, 15, 20 208/230-1 24½ 21 30 94

    MBR0800 910-720-500 3, 5, 6, 8, 10 208/230-1 17½ 21 26 72

    MBR1200 1,100-1,060-940 3, 5, 6, 8, 10, 15, 20, 21 208/230-1 17½ 21 26 72

    MBR1600 1,580-1,380-1,000 3, 5, 6, 8, 10, 15, 20, 21 208/230-1 21 21 30 82

    MBR2000 1,860-1,510-1,320 3, 5, 6, 8, 10, 15, 20, 21 208/230-1 24½ 21 30 94

    Model Ship Weight (lbs)DimensionsVoltage/

    PhaseElectric

    Heat (kW)CFM @ 0.3” ESP

    High/Med/Low

    WMAHV1200

    WMAHV1600

    WMAHV2000

    WMAHM0800

    WMAHM1200

    WMAHM1600

    WMAHM2000

    PHYSICAL DATA

  • PRODUCT SPECIFICATIONS

    Modular AH.01 www.whirlpoolcomfort.com 3

    SPECIFICATIONSCFM @ 0.3" ESP Voltage-

    htdiWretemaiDesahP)woL-deM-hgiH(

    WMAHV1200AA-1 1,200 to 600 208/230-1 4.3 15 10" 8" ½ 73

    WMAHV1600AA-1 1,600 to 1,200 208/230-1 6.3 15 10" 8" ¾ 83

    WMAHV2000AA-1 2,000 to 1,200 208/230-1 5.8 15 11" 10" ¾ 95

    WMAHM0800AA-1 910-720-500 208/230-1 1.9 15 9" 6" ¼ 72

    WMAHM1200AA-1 1,100-1,060-940 208/230-1 3 15 9" 8" ¹⁄₃ 72

    WMAHM1600AA-1 1,580-1,380-1,000 208/230-1 3.8 15 10" 8" ¹⁄₃ 82

    WMAHM2000AA-1 1,860-1,510-1,320 208/230-1 4.9 15 10" 10" ½ 94

    to unit nameplate for these specifications with approved accessory heaters installed.

    ModelShip

    Weight(lbs)

    MCA*

    * Minimum Circuit Ampacity and Maximum Overcurrent Protection Device (MOD) for blower without supplemental heat installed. Refer

    MOD*Motor

    HP

    Blower Dimensions

    WMAHM0800

    AA-1A*

    WMAHM1200

    AA-1A*

    WMAHM1600

    AA-1A*

    WMAHM2000

    AA-1A*

    WMAHV1200

    AA-1A*

    WMAHV1200

    AA-1B*

    WMAHV1600

    AA-1A*

    WMAHV1600

    AA-1B*

    WMAHV2000

    AA-1A*

    WMAHV2000

    AA-1B*

    HKR-03* X X X X X X X

    HKR-05*/-05C* X X X X X X X

    HKR-06* X X X X X X X

    HKR-08*/-08C* X X X X X X X X

    HKR-10*/-10C* X X X X X X X X X X

    XXXXXXXXX*C51-RKH

    XXXXX*C02-RKH

    XXX*C12-RKHX Allowable combinations; Shaded areas indicate restricted combinations

    * Indicates revision level that may or may not be designated

    C Indicates Circuit Breaker option

    ELECTRIC HEAT KIT DATA

    Model HKR-15C HKR-20C HKR-21C

    SPW-01 X X X

    SINGLE POINT KIT**

    **Must be installed along with any of the above compatible heat kits. This kit will fi t any WMAHV - WMAHM blower as long as a compatible heat kit is installed in the unit.

  • PRODUCT SPECIFICATIONS

    4 www.whirlpoolcomfort.com Modular AH.01

    WMAHV BLOWER PERFORMANCE DATACOOLING / HP AIRFLOW

    S1 S2 Speed Tap WMAHV1200 Airflow (SCFM)WMAHV1600

    Airflow (SCFM)WMAHV2000

    Airflow (SCFM)

    A 600 1000 1200B 800 1200 1600C 1000 1400 1800

    on on D 1200 1600 2000

    Cooling / HP / Aux Trim Cooling ProfileS3 S4 Trim Value S5 S6

    0 Aon B

    on Con on 0 on on D

    onoffoffoffoff

    on

    offon

    off off offoff

    offoff

    off on -10%10%

    HEATER KIT KW AIRFLOWS9 S10 S11 Heater KW WMAHV1200 Airflow (SCFM)

    WMAHV1600 Airflow (SCFM)

    WMAHV2000 Airflow (SCFM)

    21 NA NA NAon 20 NA NA 2000

    on 15 1400 1500 1500on on 10 1000 1000 1200

    on 8 740 1000 1000on on 6 635 800 800on on 5 600 800 800on on on 3 600 800 800

    off off offoffoff

    off offoff

    off off

    offoff

    WMAHV BLOWER PERFORMANCE DATA — DIPSWITCH SUMMARYDipswitch # Function Default Setting

    S1 - S2* A/B/C/D

    S3 - S4* Cooling / HP / Aux Trim (-10%, 0, +10%) No Trim

    S5 - S6* A,B,C,D

    S7* Dehum

    S8 Unused OnS9 - S11 Heater Kit Kw

    Off

    Off/Off/Off

    Profile 1

    Airflow DCooling / HP Airflow

    Cooling Profile

    (on/off)

    *Valid only if the system is wired in legacy mode. If system is wired in the 4-wire communicating mode, these functions are selected via the user menu in the CTK01AA T-STAT.

  • PRODUCT SPECIFICATIONS

    Modular AH.01 www.whirlpoolcomfort.com 5

    WMAHM BLOWER PERFORMANCE DATA (CONT.)

    Speed StaticWMAHM0800***

    SCFMWMAHM1200***

    SCFMWMAHM1600***

    SCFMWMAHM2000***

    SCFM

    High

    0.1 1,240 1,500 1,800 2,160

    0.2 1,170 1,460 1,740 2,080

    0.3 1,120 1,360 1,680 1,990

    0.4 1,060 1,280 1,610 1,890

    0.5 980 1,200 1,520 1,790

    0.6 900 1,110 1,430 1,690

    Medium

    0.1 900 1,380 1,540 1,730

    0.2 850 1,320 1,490 1,670

    0.3 790 1,270 1,450 1,590

    0.4 740 1,200 1,400 1,520

    0.5 680 1,140 1,350 1,420

    0.6 605 1,040 1,280 1,320

    Low

    0.1 650 1,170 1,130 1,520

    0.2 590 1,130 1,100 1,450

    0.3 540 1,080 1,070 1,360

    0.4 500 1,020 1,030 1,290

    0.5 430 950 990 1,200

    0.6 330 830 930 1,090

    External static is for blower @ 230 Volts, it does not include Coil, Air Filter or Electric heaters.

  • PRODUCT SPECIFICATIONS

    6 www.whirlpoolcomfort.com Modular AH.01

    DIMENSIONSSIDE AND FRONT VIEWS

    W

    H

    (3) KNOCKOUTS1.1251.3751.750

    .875 KNOCKOUT(2 PLACES)

    C

    6 1/2

    5

    5 1/83 1/4

    D

    20"

    TOP VIEW

    SMALL MEDIUM LARGE

    8.840

    10.159

    16.500

    11.029

    11.209

    20.021

    13.178

    11.209

    23.464

    813/16"

    103/16"

    16 ½"

    133/16"

    11¼"

    23 ½"

    17½" 21" 24½"

    11"

    11¼"

    201/16"

    Width Depth Height

    WMAHV1200AA-1 17½" 21" 26"

    WMAHV1600AA-1 21" 21" 30"

    WMAHV2000AA-1 24½" 21" 30"

    WMAHM0800AA-1 17½" 21" 26"

    WMAHM1200AA-1 17½" 21" 26"

    WMAHM1600AA-1 21" 21" 30"

    WMAHM2000AA-1 24½" 21" 30"

    ModelDimensions

  • PRODUCT SPECIFICATIONS

    Modular AH.01 www.whirlpoolcomfort.com 7

    WIRING DIAGRAMS WMAHM

    Low Voltage Wiring Diagram for Cooling Unit with optional heat kit 10KW and below

    Low Voltage Wiring Diagram for Cooling Unit with optional heat kit 15KW and above

    RED

    GREEN

    WHITE

    BLUE

    TO CONDENSINGUNIT 24V. CONNECTIONS

    #18 GA. 2 WIRES

    ROOM THERMOSTAT

    W Y G R

    R

    G

    W

    Y

    #18 GA. 4 WIRES WITHCOOLING 3 WIRES WITHOUT

    WMAHM UNIT

    ROOM THERMOSTAT

    W2 W Y G R

    TO CONDENSINGUNIT 24V. CONNECTIONS

    #18 GA. 2 WIRES

    CONTACTORCOIL

    #18 GA. 2 WIRES

    OUTDOORTHERMOSTAT(OPTIONAL)

    R

    G

    W

    Y

    #18 GA. 4 WIRE WITHCOOLING 3 WIRE WITHOUT

    GREEN

    RED

    WHITE

    BROWN

    BLUE

    WMAHM UNIT

    Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

    HIGH VOLTAGE!

    WARNING

    Disconnect all power before servicing or installing this unit.

    Multiple power sources may be present.

    Failure to do so may cause property damage, personal injury, or death.

  • PRODUCT SPECIFICATIONS

    8 www.whirlpoolcomfort.com Modular AH.01

    WIRING DIAGRAMS WMAHM (CONT.)

    C W2 Y R

    HEAT PUMP

    BLUE

    WHITE

    ORANGE

    YELLOW

    RED

    Y O C R E

    ROOM THERMOSTAT

    !"#$"%&'()

    GREEN

    BLUE

    #18 GA. 5 WIRES

    OUTDOOR THERMOSTATS(OPTIONAL) MAKE ON FALL

    BL

    #18 GA. 6 WIRE NEEDED WHEN OT IS USED

    OT - 1

    *+*),"%-."/.*(),%0(#12#"!"#$"3433

    536!%7%8,9.!

    Y

    O

    W2

    R

    BR

    G

    W

    BL

    RED

    WHITE

    W

    G

    SEE NOTE 3

    O

    R

    HEAT PUMP ROOM THERMOSTAT

    C W2 O Y R Y O GW2 R E

    R

    C

    BRG

    W

    BLBL

    W

    O

    BLUE

    WHITE

    ORANGE

    YELLOW

    RED

    RED

    GREEN

    WHITE

    BROWN

    BLUE

    EHR

    1 1

    3 4

    #18 GA. 5 WIRESOT-1

    OT-2

    #18 GA. 7 WIRES

    #18 GA. 7 WIRE NEEDED WHEN (2) OTs ARE USED.NOTES1) OUTDOOR THERMOSTAT (OT-1) SHOULD BE THE FIRST TO CLOSE AND THE FIRST TO OPEN.2) IF OUTDOOR THERMOSTAT IS NOT USED, TIE WHITE AND BROWN WIRES FROM AIR HANDLER TOGETHER. 3) REMOVE WIRE WHEN USING OUTDOOR T-STAT. #18 GA. 7 WIRE NEEDED WHEN (2) OTs ARE USED.

    NOMENCLATUREOT - OUTDOOR TEMPERATURE (OPTIONAL)MOF - MAKE ON FALLEHR - EMERGENCY HEAT RELAY (OPTIONAL)

    COLOR CODESR - REDY - YELLOWBL - BLUEV - VIOLETBR - BROWN

    O - ORANGEW - WHITEG - GREEN

    *+*),"%-."/.*(),%0(#12#"!"#$"5:33%;%:333

    #8.

  • PRODUCT SPECIFICATIONS

    Modular AH.01 www.whirlpoolcomfort.com 9

    WIRING DIAGRAMS WMAHV

    Wiri

    ng is

    sub

    ject

    to c

    hang

    e.

    Alw

    ays

    refe

    r to

    the

    wiri

    ng

    diag

    ram

    on

    the

    unit

    for

    the

    mos

    t up-

    to-d

    ate

    wiri

    ng.

    HIG

    H V

    OL

    TA

    GE

    !

    WA

    RN

    ING

    Dis

    con

    nec

    t all

    po

    wer

    bef

    ore

    ser

    vici

    ng

    or

    inst

    allin

    g th

    is u

    nit

    .

    Mu

    ltip

    le p

    ow

    er s

    ou

    rces

    may

    be

    pre

    sen

    t.

    Fai

    lure

    to d

    o s

    o m

    ay c

    ause

    pro

    per

    ty d

    amag

    e, p

    erso

    nal

    inju

    ry, o

    r d

    eath

    .

    2

    7

    GN

    CO

    OL

    DE

    LAY

    RD

    TE

    RM

    3

    BL

    RD

    8

    GN

    RD

    BK

    EL

    EC

    RD

    9

    2

    3

    BKBL

    SEE NOTE 6

    1

    BK

    BIA

    S

    UN

    US

    ED

    BR66

    PL2

    BL5

    BK

    4

    BIA

    S

    7

    9

    8

    3

    AD

    JUS

    T

    5

    LEARN

    -

    4

    RD

    DE

    HU

    M

    SEE NOTE

    7

    2

    4

    PL1

    WH

    RD

    SEENOTE 5

    1 1

    HE

    AT

    AF

    YL BK

    BK

    HTR1

    8

    L2

    FLFL

    RD

    BKWH

    2

    M7YL

    FL

    RD

    6

    R

    BL

    HTR2

    NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER

    TL TL

    TWO (2) ELEMENT ROWS

    8

    L1

    BK

    M4

    M2

    H TR2

    R2

    9

    L2

    RD

    M1

    3

    BK

    1

    BK

    M1

    BK

    BL

    ONE (1) ELEMENT ROWS

    TL

    HT R3TL

    M2

    M3

    YL

    HT R2

    RD

    FL

    BL

    L1

    TL

    L1

    4

    R2

    H TR3

    9R D

    8

    RD

    M4

    R1

    BK

    M3

    9

    WH

    BK

    BL

    M3

    6

    BK

    RD

    BK

    PURD

    6

    4

    BK

    KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE.

    FL

    M2

    PU

    R1

    H TR4

    TL

    HT R1

    FL

    BK

    M6

    PU

    HTR1

    M1

    2

    W H

    M1

    5

    PLM

    BKTL

    BR

    RD

    BK

    MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.

    6W H

    7

    M1

    BK

    9

    TL

    FL

    YL

    BR

    1

    PU

    YLBK

    BL

    BK

    PLM

    7

    5

    RD7

    M8

    R D

    2

    BL

    BL

    L2

    TL

    THREE (3) ELEMENT ROWS

    R D

    7

    3

    1FL

    L2

    BL

    RD

    4

    L1L1

    L2

    RM2

    PLM

    2

    M5

    5

    1

    4

    H TR1

    M2

    FOUR (4) ELEMENT ROWS

    TL

    FL

    BK

    5

    R DRD

    L1

    PLM

    3

    R D

    BK

    8

    YL

    RD

    L2

    BK

    BK

    3

    RD

    BL

    FL

    M4

    R D

    0140A00039 REV. A

    BLWR

    OVERCURRENT

    TR

    HEAT SEQUENCER R1

    24 V T

    HE

    RM

    OS

    TAT C

    ON

    NE

    CT

    ION

    S

    GN GREEN

    TRANSFORMER

    HEAT SEQUENCER R2

    GND

    FIELD GND

    INTERNAL TO

    TWO-STAGE INTEGRATED CONTROL MODULE TX (3)

    DEHUM

    C

    W1 (1)

    5

    FIELD SPLICE

    W1

    CFM LED

    R

    Y1

    NOTES:LOW VOLTAGE (24V)

    4

    GND

    W1

    24 V 3 A

    4

    RX (2)

    COLOR CODES:

    Y2

    TH

    STATUS LED

    5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (N THERMOSTAT INPUTS).

    208 VAC

    Y1+VDC (1)

    TH

    INTEGRATED CONTROL

    INDOOR

    PROT. DEVICE

    2 GND (4)

    1

    CTR

    RESISTER

    Y2

    2

    BR BROWN

    DISCONNECT

    L2

    W2

    YL YELLOW

    1. PLACE RED WIRE ON TRANSFORMER TERMINAL 2 FOR 208 VAC OPERATION.

    7. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT.

    COM

    24V THERM

    OSTA

    T CON

    NECTIO

    NS

    4

    RX LED

    3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE BLOWER MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY.

    HI VOLTAGE (230V)

    3

    6. BIAS AND TERM DIPSWITCHES MUST BE IN "ON" POSITION. RED STATUS LED PROVIDES NETWORK STATUS. GREEN RX LED INDICATES NETWORK TRAFFIC. USE LEARN BUTTON TO RESET NETWORK.

    W2

    2

    1 O

    INTEGRATED CONTROL MODULE

    G

    VT VIOLET

    G

    COM

    L1

    L2

    GND

    ECM MOTOR HARNESS

    JUNCTION

    GND

    208/230 VAC

    FUSE 3 A

    WH WHITE

    1

    4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

    24 VAC

    INDOOR

    L1

    40 VA TRANSFORMER, SEE NOTE 1

    HI VOLTAGE FIELD

    3

    1

    LOW VOLTAGE FIELD

    3

    2

    40 VA

    AIR

    DIP SWITCHES

    BLWRFUSE

    24 VAC

    RD RED

    DEHUM

    PLUG CONNECTION

    O

    GY GRAY

    TERMINAL

    EQUIPMENT GND

    PK PINK

    BL BLUE

    DIAGNOSTIC LED

    230 VAC

    AIR

    W2 (2)

    R TO MICRO

    CIRCULATOR

    CIRCULATOR

    OR ORANGE

    BK BLACK

    2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

    CIRCULATOR BLOWER

    COM4 CIRCUIT HEATER CONNECTOR

    BLGY

    BKRD

    GND

  • PRODUCT SPECIFICATIONS

    10 www.whirlpoolcomfort.com Modular AH.01

    Whirlpool® is a trademark of Whirlpool Corporation and used under license to Tradewinds Distributing Co. LLC. All rights reserved. Our continuing commitment to quality products may mean a change in specifi cations without notice. © 2009 • Tradewinds Distributing Co. LLC. • Jacksonville, FL • Printed in the USA.