Modular AH.01 www.whirlpoolcomfort.com 4/11
COOLING CAPACITY:18,000 - 60,000 BTU/H
WMAHM & WMAHVVARIABLE AND MULTI-SPEED
MODULAR BLOWERS
Standard Features• WMAHM is a multi-speed blower — motor speed
is easily changed• WMAHV has a variable-speed ECM™ blower motor• Cooling or heat pump applications: upfl ow, down-
fl ow, and horizontal applications• WMAHM control board includes a fan delay in cool-
ing mode and is isolated from the air stream• WCC & WCH coils are equipped with a check fl ow-
rater• Cooling and Heat Pump Applications• ARI Certifi ed• ETL Listed
Cabinet Features• Painted, galvanized steel cabinet• Blower section usable as an electric furnace• Uses HKR Electric Heat Kits• Intended for use with cased evaporator coils
(WCC & WCH) and condensing units or heat pumps• Foil-faced insulation is glued in place and covers the
entire blower case to reduce operating sound and cabinet condensation
• Bottom fl anges formed inwardly for additional strength and to provide a good mounting surface for a cased-coil section to form a two-piece blower coil
The Whirlpool® WMAHM & WMAHV Modular Blowers are tailor-made for exceptional energy effi ciency. When matched with our cased coils for upfl ow, downfl ow, and horizontal applications, these two-piece blowers increase both installation and application fl exibility.
* To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or
Québec. Full warranty details are available at www.whirlpoolhvac.com.
-
PRODUCT SPECIFICATIONS
2 www.whirlpoolcomfort.com Modular AH.01
Design SeriesMAH Modular Air Handler
ElectricalA 208-230/60/1
Motor Speed
Revisions
V Variable Speed
A First Series
M Constant Speed
Circuit Breaker
Airflow Delivered
A No Circuit Breaker
08 800 CFM
B Circuit Breaker
12 1200 CFM16 1600 CFM
Factory-installed Electric Heat
20 2000 CFM
00 No Heat
11
AM
52,3,4
AMAH
BrandW Whirlpool
1
W
12
12
6,7
00
8,9
A
10
NOMENCLATURE
W" D" H"
MBE1200 1,200 to 600 3, 5, 6, 8, 10, 15 208/230-1 17½ 21 26 72
MBE1600 1,600 to 1,200 3, 5, 6, 8, 10, 15 208/230-1 21 21 30 82
MBE2000 2,000 to 1,200 3, 5, 6, 8, 10, 15, 20 208/230-1 24½ 21 30 94
MBR0800 910-720-500 3, 5, 6, 8, 10 208/230-1 17½ 21 26 72
MBR1200 1,100-1,060-940 3, 5, 6, 8, 10, 15, 20, 21 208/230-1 17½ 21 26 72
MBR1600 1,580-1,380-1,000 3, 5, 6, 8, 10, 15, 20, 21 208/230-1 21 21 30 82
MBR2000 1,860-1,510-1,320 3, 5, 6, 8, 10, 15, 20, 21 208/230-1 24½ 21 30 94
Model Ship Weight (lbs)DimensionsVoltage/
PhaseElectric
Heat (kW)CFM @ 0.3” ESP
High/Med/Low
WMAHV1200
WMAHV1600
WMAHV2000
WMAHM0800
WMAHM1200
WMAHM1600
WMAHM2000
PHYSICAL DATA
-
PRODUCT SPECIFICATIONS
Modular AH.01 www.whirlpoolcomfort.com 3
SPECIFICATIONSCFM @ 0.3" ESP Voltage-
htdiWretemaiDesahP)woL-deM-hgiH(
WMAHV1200AA-1 1,200 to 600 208/230-1 4.3 15 10" 8" ½ 73
WMAHV1600AA-1 1,600 to 1,200 208/230-1 6.3 15 10" 8" ¾ 83
WMAHV2000AA-1 2,000 to 1,200 208/230-1 5.8 15 11" 10" ¾ 95
WMAHM0800AA-1 910-720-500 208/230-1 1.9 15 9" 6" ¼ 72
WMAHM1200AA-1 1,100-1,060-940 208/230-1 3 15 9" 8" ¹⁄₃ 72
WMAHM1600AA-1 1,580-1,380-1,000 208/230-1 3.8 15 10" 8" ¹⁄₃ 82
WMAHM2000AA-1 1,860-1,510-1,320 208/230-1 4.9 15 10" 10" ½ 94
to unit nameplate for these specifications with approved accessory heaters installed.
ModelShip
Weight(lbs)
MCA*
* Minimum Circuit Ampacity and Maximum Overcurrent Protection Device (MOD) for blower without supplemental heat installed. Refer
MOD*Motor
HP
Blower Dimensions
WMAHM0800
AA-1A*
WMAHM1200
AA-1A*
WMAHM1600
AA-1A*
WMAHM2000
AA-1A*
WMAHV1200
AA-1A*
WMAHV1200
AA-1B*
WMAHV1600
AA-1A*
WMAHV1600
AA-1B*
WMAHV2000
AA-1A*
WMAHV2000
AA-1B*
HKR-03* X X X X X X X
HKR-05*/-05C* X X X X X X X
HKR-06* X X X X X X X
HKR-08*/-08C* X X X X X X X X
HKR-10*/-10C* X X X X X X X X X X
XXXXXXXXX*C51-RKH
XXXXX*C02-RKH
XXX*C12-RKHX Allowable combinations; Shaded areas indicate restricted combinations
* Indicates revision level that may or may not be designated
C Indicates Circuit Breaker option
ELECTRIC HEAT KIT DATA
Model HKR-15C HKR-20C HKR-21C
SPW-01 X X X
SINGLE POINT KIT**
**Must be installed along with any of the above compatible heat kits. This kit will fi t any WMAHV - WMAHM blower as long as a compatible heat kit is installed in the unit.
-
PRODUCT SPECIFICATIONS
4 www.whirlpoolcomfort.com Modular AH.01
WMAHV BLOWER PERFORMANCE DATACOOLING / HP AIRFLOW
S1 S2 Speed Tap WMAHV1200 Airflow (SCFM)WMAHV1600
Airflow (SCFM)WMAHV2000
Airflow (SCFM)
A 600 1000 1200B 800 1200 1600C 1000 1400 1800
on on D 1200 1600 2000
Cooling / HP / Aux Trim Cooling ProfileS3 S4 Trim Value S5 S6
0 Aon B
on Con on 0 on on D
onoffoffoffoff
on
offon
off off offoff
offoff
off on -10%10%
HEATER KIT KW AIRFLOWS9 S10 S11 Heater KW WMAHV1200 Airflow (SCFM)
WMAHV1600 Airflow (SCFM)
WMAHV2000 Airflow (SCFM)
21 NA NA NAon 20 NA NA 2000
on 15 1400 1500 1500on on 10 1000 1000 1200
on 8 740 1000 1000on on 6 635 800 800on on 5 600 800 800on on on 3 600 800 800
off off offoffoff
off offoff
off off
offoff
WMAHV BLOWER PERFORMANCE DATA — DIPSWITCH SUMMARYDipswitch # Function Default Setting
S1 - S2* A/B/C/D
S3 - S4* Cooling / HP / Aux Trim (-10%, 0, +10%) No Trim
S5 - S6* A,B,C,D
S7* Dehum
S8 Unused OnS9 - S11 Heater Kit Kw
Off
Off/Off/Off
Profile 1
Airflow DCooling / HP Airflow
Cooling Profile
(on/off)
*Valid only if the system is wired in legacy mode. If system is wired in the 4-wire communicating mode, these functions are selected via the user menu in the CTK01AA T-STAT.
-
PRODUCT SPECIFICATIONS
Modular AH.01 www.whirlpoolcomfort.com 5
WMAHM BLOWER PERFORMANCE DATA (CONT.)
Speed StaticWMAHM0800***
SCFMWMAHM1200***
SCFMWMAHM1600***
SCFMWMAHM2000***
SCFM
High
0.1 1,240 1,500 1,800 2,160
0.2 1,170 1,460 1,740 2,080
0.3 1,120 1,360 1,680 1,990
0.4 1,060 1,280 1,610 1,890
0.5 980 1,200 1,520 1,790
0.6 900 1,110 1,430 1,690
Medium
0.1 900 1,380 1,540 1,730
0.2 850 1,320 1,490 1,670
0.3 790 1,270 1,450 1,590
0.4 740 1,200 1,400 1,520
0.5 680 1,140 1,350 1,420
0.6 605 1,040 1,280 1,320
Low
0.1 650 1,170 1,130 1,520
0.2 590 1,130 1,100 1,450
0.3 540 1,080 1,070 1,360
0.4 500 1,020 1,030 1,290
0.5 430 950 990 1,200
0.6 330 830 930 1,090
External static is for blower @ 230 Volts, it does not include Coil, Air Filter or Electric heaters.
-
PRODUCT SPECIFICATIONS
6 www.whirlpoolcomfort.com Modular AH.01
DIMENSIONSSIDE AND FRONT VIEWS
W
H
(3) KNOCKOUTS1.1251.3751.750
.875 KNOCKOUT(2 PLACES)
C
6 1/2
5
5 1/83 1/4
D
20"
TOP VIEW
SMALL MEDIUM LARGE
8.840
10.159
16.500
11.029
11.209
20.021
13.178
11.209
23.464
813/16"
103/16"
16 ½"
133/16"
11¼"
23 ½"
17½" 21" 24½"
11"
11¼"
201/16"
Width Depth Height
WMAHV1200AA-1 17½" 21" 26"
WMAHV1600AA-1 21" 21" 30"
WMAHV2000AA-1 24½" 21" 30"
WMAHM0800AA-1 17½" 21" 26"
WMAHM1200AA-1 17½" 21" 26"
WMAHM1600AA-1 21" 21" 30"
WMAHM2000AA-1 24½" 21" 30"
ModelDimensions
-
PRODUCT SPECIFICATIONS
Modular AH.01 www.whirlpoolcomfort.com 7
WIRING DIAGRAMS WMAHM
Low Voltage Wiring Diagram for Cooling Unit with optional heat kit 10KW and below
Low Voltage Wiring Diagram for Cooling Unit with optional heat kit 15KW and above
RED
GREEN
WHITE
BLUE
TO CONDENSINGUNIT 24V. CONNECTIONS
#18 GA. 2 WIRES
ROOM THERMOSTAT
W Y G R
R
G
W
Y
#18 GA. 4 WIRES WITHCOOLING 3 WIRES WITHOUT
WMAHM UNIT
ROOM THERMOSTAT
W2 W Y G R
TO CONDENSINGUNIT 24V. CONNECTIONS
#18 GA. 2 WIRES
CONTACTORCOIL
#18 GA. 2 WIRES
OUTDOORTHERMOSTAT(OPTIONAL)
R
G
W
Y
#18 GA. 4 WIRE WITHCOOLING 3 WIRE WITHOUT
GREEN
RED
WHITE
BROWN
BLUE
WMAHM UNIT
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
WARNING
Disconnect all power before servicing or installing this unit.
Multiple power sources may be present.
Failure to do so may cause property damage, personal injury, or death.
-
PRODUCT SPECIFICATIONS
8 www.whirlpoolcomfort.com Modular AH.01
WIRING DIAGRAMS WMAHM (CONT.)
C W2 Y R
HEAT PUMP
BLUE
WHITE
ORANGE
YELLOW
RED
Y O C R E
ROOM THERMOSTAT
!"#$"%&'()
GREEN
BLUE
#18 GA. 5 WIRES
OUTDOOR THERMOSTATS(OPTIONAL) MAKE ON FALL
BL
#18 GA. 6 WIRE NEEDED WHEN OT IS USED
OT - 1
*+*),"%-."/.*(),%0(#12#"!"#$"3433
536!%7%8,9.!
Y
O
W2
R
BR
G
W
BL
RED
WHITE
W
G
SEE NOTE 3
O
R
HEAT PUMP ROOM THERMOSTAT
C W2 O Y R Y O GW2 R E
R
C
BRG
W
BLBL
W
O
BLUE
WHITE
ORANGE
YELLOW
RED
RED
GREEN
WHITE
BROWN
BLUE
EHR
1 1
3 4
#18 GA. 5 WIRESOT-1
OT-2
#18 GA. 7 WIRES
#18 GA. 7 WIRE NEEDED WHEN (2) OTs ARE USED.NOTES1) OUTDOOR THERMOSTAT (OT-1) SHOULD BE THE FIRST TO CLOSE AND THE FIRST TO OPEN.2) IF OUTDOOR THERMOSTAT IS NOT USED, TIE WHITE AND BROWN WIRES FROM AIR HANDLER TOGETHER. 3) REMOVE WIRE WHEN USING OUTDOOR T-STAT. #18 GA. 7 WIRE NEEDED WHEN (2) OTs ARE USED.
NOMENCLATUREOT - OUTDOOR TEMPERATURE (OPTIONAL)MOF - MAKE ON FALLEHR - EMERGENCY HEAT RELAY (OPTIONAL)
COLOR CODESR - REDY - YELLOWBL - BLUEV - VIOLETBR - BROWN
O - ORANGEW - WHITEG - GREEN
*+*),"%-."/.*(),%0(#12#"!"#$"5:33%;%:333
#8.
-
PRODUCT SPECIFICATIONS
Modular AH.01 www.whirlpoolcomfort.com 9
WIRING DIAGRAMS WMAHV
Wiri
ng is
sub
ject
to c
hang
e.
Alw
ays
refe
r to
the
wiri
ng
diag
ram
on
the
unit
for
the
mos
t up-
to-d
ate
wiri
ng.
HIG
H V
OL
TA
GE
!
WA
RN
ING
Dis
con
nec
t all
po
wer
bef
ore
ser
vici
ng
or
inst
allin
g th
is u
nit
.
Mu
ltip
le p
ow
er s
ou
rces
may
be
pre
sen
t.
Fai
lure
to d
o s
o m
ay c
ause
pro
per
ty d
amag
e, p
erso
nal
inju
ry, o
r d
eath
.
2
7
GN
CO
OL
DE
LAY
RD
TE
RM
3
BL
RD
8
GN
RD
BK
EL
EC
RD
9
2
3
BKBL
SEE NOTE 6
1
BK
BIA
S
UN
US
ED
BR66
PL2
BL5
BK
4
BIA
S
7
9
8
3
AD
JUS
T
5
LEARN
-
4
RD
DE
HU
M
SEE NOTE
7
2
4
PL1
WH
RD
SEENOTE 5
1 1
HE
AT
AF
YL BK
BK
HTR1
8
L2
FLFL
RD
BKWH
2
M7YL
FL
RD
6
R
BL
HTR2
NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER
TL TL
TWO (2) ELEMENT ROWS
8
L1
BK
M4
M2
H TR2
R2
9
L2
RD
M1
3
BK
1
BK
M1
BK
BL
ONE (1) ELEMENT ROWS
TL
HT R3TL
M2
M3
YL
HT R2
RD
FL
BL
L1
TL
L1
4
R2
H TR3
9R D
8
RD
M4
R1
BK
M3
9
WH
BK
BL
M3
6
BK
RD
BK
PURD
6
4
BK
KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE.
FL
M2
PU
R1
H TR4
TL
HT R1
FL
BK
M6
PU
HTR1
M1
2
W H
M1
5
PLM
BKTL
BR
RD
BK
MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.
6W H
7
M1
BK
9
TL
FL
YL
BR
1
PU
YLBK
BL
BK
PLM
7
5
RD7
M8
R D
2
BL
BL
L2
TL
THREE (3) ELEMENT ROWS
R D
7
3
1FL
L2
BL
RD
4
L1L1
L2
RM2
PLM
2
M5
5
1
4
H TR1
M2
FOUR (4) ELEMENT ROWS
TL
FL
BK
5
R DRD
L1
PLM
3
R D
BK
8
YL
RD
L2
BK
BK
3
RD
BL
FL
M4
R D
0140A00039 REV. A
BLWR
OVERCURRENT
TR
HEAT SEQUENCER R1
24 V T
HE
RM
OS
TAT C
ON
NE
CT
ION
S
GN GREEN
TRANSFORMER
HEAT SEQUENCER R2
GND
FIELD GND
INTERNAL TO
TWO-STAGE INTEGRATED CONTROL MODULE TX (3)
DEHUM
C
W1 (1)
5
FIELD SPLICE
W1
CFM LED
R
Y1
NOTES:LOW VOLTAGE (24V)
4
GND
W1
24 V 3 A
4
RX (2)
COLOR CODES:
Y2
TH
STATUS LED
5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (N THERMOSTAT INPUTS).
208 VAC
Y1+VDC (1)
TH
INTEGRATED CONTROL
INDOOR
PROT. DEVICE
2 GND (4)
1
CTR
RESISTER
Y2
2
BR BROWN
DISCONNECT
L2
W2
YL YELLOW
1. PLACE RED WIRE ON TRANSFORMER TERMINAL 2 FOR 208 VAC OPERATION.
7. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT.
COM
24V THERM
OSTA
T CON
NECTIO
NS
4
RX LED
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE BLOWER MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY.
HI VOLTAGE (230V)
3
6. BIAS AND TERM DIPSWITCHES MUST BE IN "ON" POSITION. RED STATUS LED PROVIDES NETWORK STATUS. GREEN RX LED INDICATES NETWORK TRAFFIC. USE LEARN BUTTON TO RESET NETWORK.
W2
2
1 O
INTEGRATED CONTROL MODULE
G
VT VIOLET
G
COM
L1
L2
GND
ECM MOTOR HARNESS
JUNCTION
GND
208/230 VAC
FUSE 3 A
WH WHITE
1
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
24 VAC
INDOOR
L1
40 VA TRANSFORMER, SEE NOTE 1
HI VOLTAGE FIELD
3
1
LOW VOLTAGE FIELD
3
2
40 VA
AIR
DIP SWITCHES
BLWRFUSE
24 VAC
RD RED
DEHUM
PLUG CONNECTION
O
GY GRAY
TERMINAL
EQUIPMENT GND
PK PINK
BL BLUE
DIAGNOSTIC LED
230 VAC
AIR
W2 (2)
R TO MICRO
CIRCULATOR
CIRCULATOR
OR ORANGE
BK BLACK
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
CIRCULATOR BLOWER
COM4 CIRCUIT HEATER CONNECTOR
BLGY
BKRD
GND
-
PRODUCT SPECIFICATIONS
10 www.whirlpoolcomfort.com Modular AH.01
Whirlpool® is a trademark of Whirlpool Corporation and used under license to Tradewinds Distributing Co. LLC. All rights reserved. Our continuing commitment to quality products may mean a change in specifi cations without notice. © 2009 • Tradewinds Distributing Co. LLC. • Jacksonville, FL • Printed in the USA.