wuthipong suponthana member tc82, - welcome to the iec · international electrotechnical commission...
TRANSCRIPT
![Page 1: Wuthipong Suponthana Member TC82, - Welcome to the IEC · INTERNATIONAL ELECTROTECHNICAL COMMISSION Wuthipong Suponthana Member TC82, JWG1, WG3 and WG6 . ... IEC 62109- 1, -2:](https://reader031.vdocuments.net/reader031/viewer/2022030608/5ad7201d7f8b9a32618be244/html5/thumbnails/1.jpg)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
Wuthipong Suponthana Member TC82, JWG1, WG3 and WG6
Event : WIC Date : Oct 12, 2016 Location : PTB
![Page 2: Wuthipong Suponthana Member TC82, - Welcome to the IEC · INTERNATIONAL ELECTROTECHNICAL COMMISSION Wuthipong Suponthana Member TC82, JWG1, WG3 and WG6 . ... IEC 62109- 1, -2:](https://reader031.vdocuments.net/reader031/viewer/2022030608/5ad7201d7f8b9a32618be244/html5/thumbnails/2.jpg)
![Page 3: Wuthipong Suponthana Member TC82, - Welcome to the IEC · INTERNATIONAL ELECTROTECHNICAL COMMISSION Wuthipong Suponthana Member TC82, JWG1, WG3 and WG6 . ... IEC 62109- 1, -2:](https://reader031.vdocuments.net/reader031/viewer/2022030608/5ad7201d7f8b9a32618be244/html5/thumbnails/3.jpg)
IEC 62257 TECHNICAL SPECIFICATIONS : Recommendations for small renewable energy and hybrid systems for rural electrification
![Page 4: Wuthipong Suponthana Member TC82, - Welcome to the IEC · INTERNATIONAL ELECTROTECHNICAL COMMISSION Wuthipong Suponthana Member TC82, JWG1, WG3 and WG6 . ... IEC 62109- 1, -2:](https://reader031.vdocuments.net/reader031/viewer/2022030608/5ad7201d7f8b9a32618be244/html5/thumbnails/4.jpg)
Battery
MTP-6117H
300 kW x3
1,200 kWh @ 10 h 480 Vdc 3000 Ah
450 kVA 350 kVABi-Direction Bi-Direction Bi-Direction
MPPTMPPT MPPT
415 Vac
DC Switch Panel
1 M
VA
1 M
VA
Pow
er H
ouse
Load
Pow
er S
tatio
n Lo
ad
PV 62.5 kWp
PV 62.5 kWp
PV 62.5 kWp
SCM-48020010 units
DG PlantController
InverterSystem
Controller
(HCCU)
V-SAT SYSTEM
LAN
Router
RS4
85
RS4
85R
S485
Fuel level Tank 1
Fuel level Tank 2
V-F2CH91
SMU
1
LAN
LAN
BMS
Battery
1,200 kWh @ 10 h 480 Vdc 3000 Ah
BMSMPPT MPPT
PV 62.5 kWp
PV 62.5 kWp
Indoor Temp.
Pyranometer
V-F2CH91
GCI GCI 1 M
VA
1 M
VA
GTP-512
250 kW x3
PV 250 kWp
PV 250 kWp
Battery
1,200 kWh @ 10 h 480 Vdc 3000 Ah
BMSMPPT
PV 62.5 kWp
450 kVA
1 M
VA
AC Switch Panel
GCI
PV 250 kWp
IEC 62548 : PV arrays – Design Requirement
IEC 62116 : Islanding
IEC 61427-2 : Battery Testing for PV
IEC 61727 : Utility Interconnected
IEC 60439-1 : LV Switch Gear & control gear type-tested IEC 60439-2 : LV switch gear & control gear Assembly
IEC 62257-2 : From requirement to a range of electrical system IEC 62257-4 : Design
IEC 61683 : Inverter Efficiency Test
IEC 61724-1, -2, -3: PV Performance Evaluation
IEC 62257-7-3 : Selection of Generator set for rural electrification
IEC 60038 : Standard Voltages
IEC 62109-1, -2: Safety of PCE
IEC 61850-7-420 : Data com. for DER
IEC 61215 : PV module - Design Qualification
IEC 60034 : Rotating electrical machine
IEC 60076 : Power Transformer
IEC 62509 : Battery charge controllers for photovoltaic systems - Performance and functioning.
IEC 60364-5-57 : Battery Selection and eraction
![Page 5: Wuthipong Suponthana Member TC82, - Welcome to the IEC · INTERNATIONAL ELECTROTECHNICAL COMMISSION Wuthipong Suponthana Member TC82, JWG1, WG3 and WG6 . ... IEC 62109- 1, -2:](https://reader031.vdocuments.net/reader031/viewer/2022030608/5ad7201d7f8b9a32618be244/html5/thumbnails/5.jpg)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
Wuthipong Suponthana Member TC82, JWG1, WG3 and WG6
Event : WIC Date : Oct 12, 2016 Location : PTB