April 30, 2018 Mr. Jason Thomas WYPDES Permit Section Department of Environmental Quality/WQD 200 W. 17th St. 4th Floor Cheyenne, Wyoming 82002 RE: Renewal for EOG Y Resources, Inc. WYPDES Permit WY0056502 Dear Mr. Thomas: On behalf of EOG Y Resources, Inc. (EOG), WWC Engineering (WWC) is submitting the following materials for WYPDES permit WY0056502 (Rolling Pin Spatula State). WYPDES permit renewal application; Topographic map showing the CBNG wells, water pipeline connections, and the discharge points; Water quality analysis; A CD with all the submitted materials in digital format. EOG is applying for renewal of existing WYPDES permit WY056502, an Option 2 facility, located in southeastern Johnson County and southwestern Campbell County. WYPDES permit WY0056502 authorizes discharge of CBNG produced water to on- channel reservoirs located in unnamed ephemeral tributaries to Cottonwood Creek which is tributary to the Powder River. The permitted discharges are located in Township 43 North, Range 77 West. If you have any questions or comments, please contact us at (307) 672-0761. Thank you, Ray Moores, P.E. Project Manager RM Enclosures: as noted cc: Jason Rauen K:\Sheridan\Yates\05014\Task 124 Rollin Pin Spatula\Corres\WYPDES Permit Renewal_4-30-18.doc 1849 Terra Avenue • Sheridan, WY 82801 Phone: 307-672-0761 • Fax: 307-674-4265 www.wwcengineering.com

Upload: others

Post on 09-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

April 30, 2018

Mr. Jason Thomas WYPDES Permit Section Department of Environmental Quality/WQD 200 W. 17th St. 4th Floor Cheyenne, Wyoming 82002 RE: Renewal for EOG Y Resources, Inc. WYPDES Permit WY0056502 Dear Mr. Thomas: On behalf of EOG Y Resources, Inc. (EOG), WWC Engineering (WWC) is submitting the following materials for WYPDES permit WY0056502 (Rolling Pin Spatula State).

• WYPDES permit renewal application;

• Topographic map showing the CBNG wells, water pipeline connections, and the discharge points;

• Water quality analysis;

• A CD with all the submitted materials in digital format.

EOG is applying for renewal of existing WYPDES permit WY056502, an Option 2 facility, located in southeastern Johnson County and southwestern Campbell County. WYPDES permit WY0056502 authorizes discharge of CBNG produced water to on-channel reservoirs located in unnamed ephemeral tributaries to Cottonwood Creek which is tributary to the Powder River. The permitted discharges are located in Township 43 North, Range 77 West. If you have any questions or comments, please contact us at (307) 672-0761.

Thank you,

Ray Moores, P.E. Project Manager

RM Enclosures: as noted cc: Jason Rauen K:\Sheridan\Yates\05014\Task 124 Rollin Pin Spatula\Corres\WYPDES Permit Renewal_4-30-18.doc

1849 Terra Avenue • Sheridan, WY 82801

Phone: 307-672-0761 • Fax: 307-674-4265

www.wwcengineering.com

Page 2: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/30/Renewal Application/HUC1009020202/WY0056502 Page 1 of 14

SUBMIT ONE HARD COPY AND ONE ELECTRONIC COPY

WYOMING POLLUTANT DISCHARGE ELIMINATION SYSTEM

APPLICATION FOR PERMIT TO SURFACE DISCHARGE PRODUCED WATER

FROM COAL BED METHANE NEW DISCHARGES, RENEWALS, OR MAJOR

MODIFICATIONS

Revised: 4-25-16

PLEASE PRINT OR TYPE (Submission of illegible materials will result in return of

the application to the applicant)

1. Check the box corresponding to the type of application being applied for:

New CBM permit

CBM permit renewal Permit number WY0056502 Expiration Date: June 30, 2018

CBM permit major modification Permit number _____________ Expiration Date: ________________

2. Identify the river basin in which the discharge will occur:

Belle Fourche Cheyenne Powder Little Powder Tongue

Other (identify) _________________________________________

3. Select permit option(s): if more than one option is selected, the applicant must describe which option applies to which

outfall.

Option 1A – Discharge is contained within an off-channel pit (class 4C) capable of containing all effluent plus up to a

50-year / 24-hour storm event. For existing permits only, Option 1A also applies to discharges that are contained within a

headwater reservoir situated within a class 4 channel and capable of containing all effluent plus up to a 50-year/24-hour

storm event.

Option 1B – Discharge is contained within a natural closed basin or playa lake (class 3A). Option 1B also applies to

discharges that are contained within a headwater reservoir situated within a class 3 channel and capable of containing all

effluent plus up to a 50-year/24-hour storm event. Option 1B headwater reservoirs shall not be located within alluvial

deposits or the floodplain of any perennial, intermittent or ephemeral stream. Option 1B headwater reservoirs less than 50

acre feet in capacity shall not be located within 500 feet of such features; reservoirs greater than 50 acre feet in capacity shall

not be located within ¼ mile (1320 feet) of such features.

Option 2 – This option includes any on-channel discharge (including discharge into an on-channel reservoir) that does

not meet the impoundment requirements specified in options 1A or 1B above.

4. General Facility Location: Township(s) 43 North Range(s) 76 West

Immediate Receiving Stream(s) Produced water will be discharged to on-channel reservoirs located on unnamed

ephemeral tributaries to Cottonwood Creek which is tributary to the Dry Fork of the Powder River, tributary to the

Powder River.

5. Name of the facility producing the discharge (this is the facility name that will appear on the WYPDES permit)

Rolling Pin Spatula State

For Agency Use Only

Application Number

WY00_______________

Date Received:

__________________ (mo/day/yr)

Page 3: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/30/Renewal Application/HUC1009020202/WY0056502 Page 2 of 14

6. Company, Contact Name, mailing address, e-mail address, and telephone number of the individual or company which

owns the facility producing the discharge, and the person (consultant) responsible for permit submission.

Company Contact Name Jason Rauen

Consultant Contact Name Ray Moores

Company Name

EOG Y Resources, Inc.

Company Name

WWC Engineering

Mailing Address

600 17th Street, Suite 1000N

Mailing Address

1849 Terra Avenue

City, State, and Zip Code Denver, CO 80202

City, State, and Zip Code Sheridan, WY 82801

Telephone Number (303) 262-9914

Telephone Number (307) 672-0761

E-Mail Address Jason [email protected]

E-Mail Address [email protected]

Status of applicant as owner, operator or both Both.

Status of applicant as federal, state, private or public Public company.

7.a. If applying for outfalls under Option 2, are any of the proposed Option 2 outfalls DIRECT DISCHARGES*that

would require the use of assimilative capacity credits for salt and sodium in the Powder River?

Yes No

If “yes”, please complete Table 5.

*DIRECT DISCHARGE means those discharges that are not or are only partially contained within reservoirs. Discharges to

reservoirs that only overtop and spill during storm events are not subject to assimilative capacity requirements. Direct discharges that

can meet Powder River ambient concentrations for TDS and sodium are also not subject to assimilative capacity requirements.

7.b. If applying for outfalls under Option 2, is it possible that INTENTIONAL RESERVOIR RELEASES* will be

requested for any of the reservoirs receiving CBM discharges under this permit?

Yes No

*INTENTIONAL RESERVOIR RELEASE means purposeful and intentional reservoir releases (opening a valve or pumping out

a reservoir) to provide freeboard within a reservoir. Discharges that occur solely in response to storm events are not considered

intentional reservoir releases, and do not require assimilative capacity credits. Intentional reservoir releases are authorized on a

case-by-case basis and require WDEQ approval above and beyond a WYPDES surface discharge permit (authorization

application form available on WDEQ website).

8. If submitting a major modification or permit renewal, please describe all requested permit modifications (i.e. add 2

outfalls, add 23 wells, move outfall 001 500 feet…):

1. Remove outfall 006, associated reservoir, and reservoir monitoring point. __________________

2. _____________________________________________________________________________

3. _____________________________________________________________________________

(add additional lines as necessary)

*NOTE: Major modification applications requesting to increase the permitted flow for a facility will be processed as

RENEWALS. Major modification applications for permits within six months of their expiration date will also be processed

as RENEWALS.

Page 4: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/30/Renewal Application/HUC1009020202/WY0056502 Page 3 of 14

9. Name(s) and mailing address(es) of owner(s) of the surface rights on whose land the discharge occurs (in cases where

the land is owned by the state or federal government but surface rights are leased to a private individual, provide lessee’s

name and address)

(additional spaces may be added as necessary)

10a. Please provide the maximum anticipated discharge rate, in million gallons per day (MGD), from this facility:

The maximum anticipated discharge rate from this facility is controlled by the consumptive capacity of the

reservoirs which is estimated at 1.69 MGD. The reservoirs will contain all effluent during normal operations

and will only overtop during a storm event of any magnitude.

10b. Does this facility rely on containment in reservoirs (of any type) as part of the water management strategy?

YES NO

10c. If NO is checked above, please proceed to item #11. If YES is checked above, the permittee is required to conduct

an internal evaluation of the ability of the reservoir(s) at this facility to contain discharges. Based on the results of this

evaluation, please describe the ability of the reservoir(s) at this facility to contain effluent and surface run-off from

precipitation events. If there are multiple reservoirs at this facility which have different reservoir containment

capabilities, please describe separately, identifying reservoirs using reservoir name. For example, “Reservoir A will

contain all effluent and will only overtop during a storm event of any magnitude; Reservoir B will contain all effluent plus

surface run-off from up to the 50 year/24 hour storm event, etc…”:

All reservoirs will be operated such that they contain all effluent during normal operations and will only overtop during a

storm event of any magnitude. _____________________________________________________________________________

_______________________________________________________________________________________________________

_______________________________________________________________________________________________________

The internal evaluation does NOT need to be submitted to the WYPDES Program as part of this application. By completing

item 10b and signing this application, the permittee certifies that the reservoirs at this facility are capable of meeting the

containment abilities which have been provided. The WYPDES Program will use the information provided above to

determine the appropriate reservoir containment requirements that will be established in the permit. If reservoir containment

requirements established in the permit are not met, this may constitute a violation of the permit, which is subject to full

enforcement by the WYPDES Program.

11. Attach a description and a clear, legible, detailed topographic map of the discharging facility. Include the following:

a. A legend. Please refer to Exhibit 1.

b. Well locations. Please refer to Exhibit 1.

c. Ponds. N/A. This facility does not utilize ponds.

d. Reservoirs. Please refer to Exhibit 1.

e. Stock tanks. Please refer to Exhibit 1.

f. Discharge points (outfalls). Please refer to Exhibit 1.

g. Immediate receiving streams. Please refer to Exhibit 1.

h. Water quality monitoring stations. Please refer to Exhibit 2.

i. Irrigation monitoring points. Please refer to Exhibit 1.

j. Location of nearest downstream irrigator. Please refer to Question 26.

k. Well locations where fluids from the facility are injected underground. N/A. l. Springs, other surface water bodies, drinking water wells, and surface water intake structures listed in public records, or otherwise

known to the applicant in the map area. Please refer to Exhibit 1 for surface water features. If present, all non-CBM

related water wells within the same section where an outfall is located are included in Exhibit 1.

m. Location of treatment facilities. N/A.

Landowner #1 Name

Kenneth R. Zink Revocable

Trust c/o Constance Zornes

Landowner #2 Name

Kenneth R. Zink Revocable

Trust c/o Betty Lou Pane

Landowner #3 Name

T-Chair Land Co. c/o Patricia

Clark

Mailing Address

758 North Treetop Lane

Mailing Address

1613 Westminster Trail

Mailing Address

1024 Brown Road

City, State, and Zip Code

Springfield, MO 65802

City, State, and Zip Code

Roanoke, TX 76262

City, State, and Zip Code

Gillette, WY 82718

Page 5: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/30/Renewal Application/HUC1009020202/WY0056502 Page 4 of 14

n. If proposing to use class 4C off-channel pits (option 1A), include footprint outline of the proposed pits. To denote

setback distance, include a distance marker from closest side of pit to the nearest water feature, floodplain, or stream

alluvium. Identify latitude and longitude in decimal degrees (using a minimum of 6 decimal places) for each end point

of the setback distance marker. N/A. This is an Option 2 facility.

o. If proposing discharge to a headwater reservoir or to a playa lake (option 1B), include footprint outline of the

proposed impoundment(s). See page 1 of the application form for option 1B impoundment siting requirements. To

denote setback distance from alluvial floodplain areas, include a distance marker from closest side of the impoundment

to the nearest floodplain, or stream alluvium. Identify latitude and longitude in decimal degrees (using a minimum of 6

decimal places) for each end point of the setback distance marker. N/A. This is an Option 2 facility.

If any of the above are not applicable please indicate in the description and include a brief explanation as to why the item

is not applicable)

12. Describe the control measures that will be implemented to prevent significant damage to or erosion of the receiving

water channel at the point of discharge.

Discharge points are located in areas of minimal slope towards the receiving channel/reservoir. Energy dissipation

devices will be utilized at the discharge points to minimize erosion.

13. Describe the control measures that will be implemented to achieve water quality standards and effluent limits. If

proposing to utilize a treatment process, provide a description of the treatment process. Water quality is good and will meet water quality standards and effluent limits. The outfalls are constructed of riprap that passively aerates the water to help induce the oxidation and precipitation of dissolved metals prior to reaching the receiving channel/reservoir.

14. For facilities that utilize mechanical treatments systems, other than reservoirs, please provide a schematic line drawing

showing the water flow and water balance through the facility. The water balance must show approximate average flows at

intake and discharge points and between units, including treatment units. If a water balance cannot be determined, a pictorial

description of the nature and amount of any sources of water and any collection and treatment measures may be provided.

N/A. This facility does not utilize mechanical treatment systems.

15. Outfall locations must be established as part of a preliminary field reconnaissance survey using GPS or conventional

survey equipment and documented in Table 1. Please document the type of equipment used, the expected accuracy of your

measurements, and a brief rationale for locating the outfalls at the requested sites below. The outfalls were located using a handheld GPS unit with a stated accuracy of +/- 50 feet. Rationale for determination of outfall locations were suitable sites that limit erosional potential and still meet landowner requests for discharge.

16. Complete the attached Table 1. Provide all the information requested in the table for each proposed discharge point or

monitoring point. If proposing changes (a major modification) to an existing facility, clearly indicate the desired changes on

the table. Additional tables may be attached. Use the format provided. Option 2 permits, except those located in the Belle

Fourche or Cheyenne River Basins, must include water quality monitoring station locations. Option 1B headwater reservoir

discharges (reservoirs other than playa lakes capable of 50 year, 24 hour stormwater runoff containment) must include flow

monitoring station locations. Option 1A and 1B permits must include containment unit monitoring station locations.

Information related to reservoirs is only required if the facility’s water management plan includes reservoir containment.

See Table 1.

17. Complete the attached Table 2. Provide all the information requested in the table for each well associated with this

proposed discharge authorization. If proposing changes (a major modification) to an existing facility, clearly indicate the

desired changes on the table. Additional tables may be attached. Use the format provided. See Table 2.

18. Complete the attached Table 3. Provide all the information requested in the table for each reservoir proposed for

containment of CBM produced water. Specified locations refer to the approximate center of the reservoir. If proposing

changes (a major modification) to an existing facility, clearly indicate the desired changes on the table. Additional tables

may be attached. Use the format provided. Information related to reservoirs is only required if the facility’s water

management plan includes reservoir containment. See Table 3.

19. Complete the attached Table 4. Provide all information requested in the table related to reservoir bonding requirements

for each reservoir proposed for the containment of CBM produced water. If proposing any changes (a major modification)

Page 6: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/30/Renewal Application/HUC1009020202/WY0056502 Page 5 of 14

to an existing facility, clearly indicate the desired changes on the table. Additional tables may be attached. Use the format

provided. Information related to reservoirs is only required if the facility’s water management plan includes reservoir

containment. See Table 4.

20. Provide a list of all potential pollutants expected to be in the discharge and an explanation of their presence in the

discharge.

Discharge is expected to meet all water quality standards and effluent limits established in this WYPDES

permit. Please see question 25 for further discussion.

21. Provide the results of water analyses for a sample collected from a location representative of the quality of the water

being proposed for discharge for all of the chemical parameters listed in the table below. The sample must be collected

from well(s) or outfall(s) within a twenty mile radius of the proposed facility’s location, and from the same coal formation(s)

and the same approximate depth(s) as proposed in this application. If filing an application for a permit renewal or

modification, the representative sample must be collected from the facility being proposed for renewal or modification.

Explain why this sample is representative of the produced water to be discharged.

Please refer to the attached water quality sample taken from Outfall 005 of WYPDES permit WY0056502. Since this

sample was collected from this permit, it is representative of the water that will be discharged from this facility

Samples from co-mingled coal seams are acceptable as long as the sample(s) meet the following criteria:

A. all of the coal seams being proposed for development are represented in the co-mingled sample, with no contribution

from coal seams not being proposed for development at the new facility.

B. the ratio of each coal seam’s contribution is approximately the same in the sample and the proposed development,

C. documentation is provided to verify the criteria listed in A. and B.

The analyses must be conducted in accordance with approved EPA test procedures (40 CFR Part 136). Include a signed

copy of your lab report that includes the following:

a. Analytical method

b. Results of each of the chemical parameters at the chemical state given below

c. Quarter/quarter, section, township and range of the sample collection location

d. Time and date of sample collection

e. Time and date of analysis for each parameter

f. Analyst’s initials for each parameter

g. Detection limit for each parameter as achieved by the laboratory

h. WYPDES permit number and outfall number, where the sample was collected.

i. Origin of produced water (coal seam and legal location of sample collection location)

If more than one coal seam is being proposed for development, the permittee must submit a lab analysis and complete

information characterizing water quality from each coal seam being proposed for development. If the permittee is proposing

to include discharges from a coal seam not previously developed at this facility, the permittee must submit a lab analysis and

complete information characterizing water quality from the new coal seam being proposed for development. A mixing

analysis may be required if the representative water quality analysis from the new coal seam indicates that the inclusion of

the new effluent source may result in degradation of existing effluent quality. Analyses must be provided in the units listed

below.

Parameter* (See notes following

the table on chemical states)

Required Detection Limits and Required Units

Alkalinity, Total 1 mg/l as CaCO3

Aluminum, Dissolved 50 g/l

Arsenic, Total Recoverable 1 g/l

Barium, Total Recoverable 100 g/l

Bicarbonate 10 mg/l

Cadmium, Dissolved 5 g/l

Page 7: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/30/Renewal Application/HUC1009020202/WY0056502 Page 6 of 14

Parameter* (See notes following

the table on chemical states)

Required Detection Limits and Required Units

Calcium, Dissolved 50 g/l, report as mg/l

Chlorides 5 mg/l

Copper, Dissolved 10 g/l

Dissolved Solids, Total 5 mg/l

Fluoride, Dissolved 100 µg/l

Hardness, Total 10 mg/l as CaCO3

Iron, Dissolved 50 g/l

Lead, Dissolved 2 g/l

Magnesium, Dissolved 1 mg/l, report as mg/l

Manganese, Dissolved 50 g/l

Mercury, Dissolved 1 g/l

pH to 0.1 pH unit

Radium 226, Total Recoverable 0.2 pCi/l

Radium 228, Total Recoverable** 0.2 pCi/l

Selenium, Total Recoverable 5 g/l

Sodium Adsorption Ratio Calculated as unadjusted ratio

Sodium, Dissolved 100 g/l, report as mg/l

Specific Conductance 5 micromhos/cm

Sulfates 10 mg/l

Zinc, Dissolved 50 g/l

*Discharges into drainages other than the Powder River geologic basin may require analysis of additional parameters,

please contact the WDEQ for a separate list.

**This parameter is only required for those discharges located within one stream mile of a class 2 water.

22. For new facilities, provide the expected (estimated) flow volume from each well in gallons per day, and provide the

rationale behind the flow volume estimate. For existing facilities, provide actual flow data from all wells within the last six

months.

N/A. This is an existing facility.

23. For new facilities, provide the expected (estimated) flow rate from each outfall in barrels per day and million gallons per

day, and provide the rationale behind the flow rate estimate. N/A. This is an existing facility.

Expected date of commencement of discharge. _________________________________

For existing facilities, provide actual flow data from each outfall within the last six months

No water has been discharged under this WYPDES permit over the last 6 months. Some of the wells are temporarily shut-in or not yet constructed for economic purposes and/or alternate discharge points under adjacent WYPDES permits are being utilized to discharge produced water. The current permit does not specify a maximum flowrate. Since discharge rates to this facility are limited by containment capacity, EOG Y respectfully requests that upon renewal the permit not specify a maximum permitted flow rate.

Will discharge be continuous or intermittent?

If the discharge is to be intermittent the following information for each outfall shall be provided:

(I) Number of times per year the discharge is to occur.

(II) Anticipated duration of each discharge.

(III) Anticipated flow of each discharge.

(IV) Months in which discharge is expected to occur.

Page 8: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/30/Renewal Application/HUC1009020202/WY0056502 Page 7 of 14

24. For applications for new facilities, are any of the required chemical constituents in the laboratory analysis present in

concentrations above Wyoming Water Quality Standards?

YES NO N/A. This is an existing facility.

If the answer to question # 21 is yes, answer 21.a. – 21.b below. If no, proceed to question 23.

a. Which constituents?

b. Has this constituent been addressed in the response to question 13?

25. For applications for existing facilities, has the facility ever exceeded permit limits or water quality standards? If the

facility has never discharged or has not yet been constructed, please indicate below.

YES NO

If the answer to question 22 is yes, answer 22.a. – 22.c. If no, proceed to question 23.

a. Which constituents? Barium

b. Has the exceedance been addressed? Yes

c. Describe how the exceedance was addressed. EOG has not had any further exceedances since 2009.

26. Does any irrigation occur downstream of the discharge? Please note that irrigation may include conventional

(artificial) irrigation involving the use of diversion structures; as well as natural irrigation, which occurs passively

from overbank flooding or sub-irrigation.

Downstream irrigation has been well documented in a Section 20 analysis submitted in conjunction with Bill

Barrett’s Pine Tree POD (WY0055751). Please refer to the Section 20 analysis submitted with WY0055751 for

details on downstream irrigation. Outfalls 001-004 are located above known irrigation activity on the Dry Fork

Powder River mainstem. Outfall 005 is located downstream of documented irrigation.

YES NO

If yes, at a minimum, the WYPDES Program requires submission of the following information:

1. Location(s) of irrigation diversions (if any) and/or naturally-irrigated acreage;

2. Type(s) of Crops grown under irrigation;

3. Description of Irrigation Practices

4. A topographic map showing irrigated acreage, any structures, ownership of irrigated acreage.

In addition to the minimum information described above, the WYPDES Program may require additional

information should the permittee request site-specific effluent limits protective of irrigation uses. Contact the

WYPDES Program for more information regarding requirements for site-specific SAR, TDS, and EC limits.

27. Provide name(s) and address(es) for all downstream irrigators between the outfalls and the mainstem.

Irrigator #1 Name

T-Chair Land Company; c/o Patricia Clark

Irrigator #2 Name

Mailing Address

1024 Brown Road

Mailing Address

City, State, and Zip Code

Gillette, WY 82718

City, State, and Zip Code

(additional spaces may be added as necessary)

Page 9: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/30/Renewal Application/HUC1009020202/WY0056502 Page 8 of 14

28. The applicant may submit any optional information the applicant wishes to have considered.

___________________________________________________________________________________________

I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in

accordance with a system designed to assure that qualified personnel properly gather and evaluate the information

submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for

gathering the information, the information submitted is to the best of my knowledge and belief, true, accurate, and complete.

I am aware that there are significant penalties for submitting false information, including the possibility of fine and

imprisonment for knowing violations. I am requesting 5 (fill in number) outfalls in this application.

Jason Rauen Environmental Supervisor

Printed Name of Person Signing* Title

Signature* Date

*All permit applications must be signed in accordance with Section 14, Chapter 2 of the Wyoming Water Quality Rules and

Regulations, “for” or “by” signatures are not acceptable.

Section 35-11-901 of Wyoming Statutes provides that:

Any person who knowingly makes any false statement, representation, or certification in any application ... shall upon

conviction be fined not more than $10,000 or imprisoned for not more than one year, or both. Permittees are required to

retain records of all data used to complete permit applications in accordance with Chapter 2, Section 5, Part 5.V.vii of the

Wyoming Water Quality Rules and Regulations.

Mail this application to:

WYPDES Permits Section

Department of Environmental Quality/WQD

200 W. 17th St. 4th Floor

Cheyenne, WY 82002

Page 10: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/30/Renewal Application/HUC1009020202/WY0056502 Page 9 of 14

Wyoming Statute 35-11-312 was revised to require discharge permit fees be paid prior to permit issuance. Therefore, payment of

permit fees must be accompanied with the application. Any application received without proper fee payment will be returned.

Individual permits are issued for a period of five years. A check for $500 per permit must be included with all applications for new

permits and renewals for individual WYPDES permits.

I have enclosed a check for $______________.

Check Number ________________

For Agency Use Only

Date Check Received __________________

Check Amount ________________

Permit Term __________________

Approval _______________

Page 11: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/30/Renewal Application/ HUC1009020202/WY0056502 Page 10 of 14

TABLE 1: Outfall, Water Quality Monitoring Station, Containment Unit, and Flow Monitoring Station Location Information

Desired

Changes

(modifications

and renewals

only

Discharge

Point

(Outfall)

#

Immediate

Receiving

Stream

Mainstem

(closest

perennial

water)

Distance

from

outfalls to

mainstem

QTR/

QTR Section TNP Range

Latitude

Longitude

County

Reservoir

Name and

Type

001 Unnamed Tributary

to Cottonwood Creek

Powder

River 29.0 mi NENW 9 43N 76W 43.72058 -106.00236 Campbell Bull Pasture #3

(on-channel)

002 Unnamed Tributary

to Cottonwood Creek Powder

River 26.9 mi NENE 17 43N 76W 43.70695 -106.01022 Campbell Bull Pasture #4

(on-channel)

003 Unnamed Tributary

to Cottonwood Creek Powder

River 26.9 mi NWNW 16 43N 76W 43.70804 -106.00564 Campbell Dune

(on-channel)

004 Unnamed Tributary

to Cottonwood Creek Powder River

27.6 mi NWSE 16 43N 76W 43.69706 -105.99627 Campbell Thumper

(on-channel)

005 Unnamed Tributary

to Cottonwood Creek Powder

River 20.5 mi NENW 18 43N 76W 43.70501 -106.04033 Johnson

Tex

(on-channel)

Remove Outfall 006 Unnamed Tributary

to Cottonwood Creek Powder River

23.7 mi NWSE 18 43N 76W 43.69873 -106.03749 Johnson Zink

(on-channel)

UPR Upstream Powder River monitoring

station (above Dry Fork Powder) NESW 17 44N 78W 43.77717 -106.25822

Only required for Option 2 outfalls in drainages

other than the Belle Fourche and Cheyenne Rivers, facility may require more than one TRIB

station

DPR

Downstream Powder River

monitoring station (below Dry Fork

Powder)

SWNW 9 44N 78W 43.79234 -106.25311

TRIB1 Tributary monitoring station on Dry

Fork Powder River SENW 16 44N 78W 43.78304 -106.19984

CU1 Containment unit water quality

monitoring station N/A - Option 2 permit application

Only required for option 1A and Option 1B

permits. Separate containment unit monitoring

stations are required for each containment unit CU2 Containment unit water quality

monitoring station

FM1 Flow monitoring station

N/A - Option 2 permit application

Only required for Option 1A discharges that are

not into off-channel pits (i.e. 50 yr/24 hour containment in on-channel reservoirs located in

Class 4 drainages) and forOption 1B reservoirs

that are not playa lakes.Separate flow monitoring stations are required for each

containment unit

FM2 Flow monitoring station

Please note that not all station types may be applicable for a particular facility. Additional spaces/pages may be added if necessary. Use the format provided. Please denote reservoir type(s) – on channel, off-channel, playa,

headwater Option 1B – in the appropriate column. Please note that reservoir information is not required if reservoir containment is not part of the facility’s water management plan – for instance, information about existing “incidental” downstream reservoirs is not required. Please use North American Datum 1983 (NAD 83) when reporting latitudes and longitudes.

Page 12: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/6/Renewal Application/ HUC1009020202/WY0056502 Page 11 of 14

TABLE 2: WELL INFORMATION

Desired

changes Well Name

API

Number

Coal

Seam(s)

Well

Depth

Legal Location (QQ,

Section, Township,

Range)

Discharge

to

Outfall # - Spatula CS State 1 49-005-58232 Big George 1,625 NENE, 16, T43N, R76W AWAO

- Spatula CS State 2 49-005-53900 Big George 1,605 NENW, 16, T43N, R76W AWAO

- Spatula CS State 3 49-005-58233 Big George 1,570 SWNW, 16, T43N, R76W AWAO

- Spatula CS State 4 49-005-58234 Big George 1,575 SWNE, 16, T43N, R76W AWAO

- Spatula CS State 5 49-005-47350 Big George 1,285 NESW, 16, T43N, R76W AWAO

- Spatula CS State 6 49-005-58235 Big George 1,465 SWSW, 16, T43N, R76W AWAO

- Rolling Pin CS State 1 49-005-58387 Big George 1,510 SESE, 16, T43N, R76W AWAO

- Rolling Pin CS State 2 49-005-40940 Big George 1,510 NWSE, 16, T43N, R76W AWAO

- Blade CS Federal 1 49-019-28526 Big George 1740' NENE, 1, 43N, 77W AWAO

- Blade CS Federal 2 49-019-28530 Big George 1700' SWNE, 1, 43N, 77W AWAO

- Blade CS Federal 3 49-019-28531 Big George 1630' NESE, 1, 43N, 77W AWAO

- Blade CS Federal 4 49-019-28532 Big George 1620' SWSE, 1, 43N, 77W AWAO

- Blade CS Federal 5 49-019-28538 Big George 1530' NENW, 10, 43N, 77W AWAO

- Blade CS Federal 6 49-019-38533 Big George 1635' SWNW, 10, 43N, 77W AWAO

- Blade CS Federal 7 49-019-28540 Big George 1515' SWNE, 10, 43N, 77W AWAO

- Blade CS Federal 8 49-019-28536 Big George 1515' NESE, 10, 43N, 77W AWAO

- Blade CS Federal 9 49-019-28539 Big George 1630' NESW, 10, 43N, 77W AWAO

- Blade CS Federal 10 49-019-28537 Big George 1655' SWSW, 10, 43N, 77W AWAO

- Blade CS Federal 11 49-019-28535 Big George 1570' SWSE, 10, 43N, 77W AWAO

- Blade CS Federal 12 TBD Big George 1450' SWNW, 11, 43N, 77W AWAO

- Blade CS Federal 13 49-019-28534 Big George 1385' NESW, 11, 43N, 77W AWAO

- Blade CS Federal 14 49-019-28525 Big George 1510' SWSW, 11, 43N, 77W AWAO

- Blade CS Federal Com 15 TBD Big George 1385' SWSE, 11, 43N, 77W AWAO

- Blade CS Federal 16 49-019-28529 Big George 1430' NENE, 13, 43N, 77W AWAO

- Blade CS Federal Com 17 49-019-27124 Big George 1435' NENW, 13, 43N, 77W AWAO

- Blade CS Federal 18 49-019-28528 Big George 1525' NESE, 13, 43N, 77W AWAO

- Blade CS Federal 19 49-019-28524 Big George 1610' NENW, 24, 43N, 77W AWAO

- Blade CS Federal 20 49-019-28527 Big George 1615' SWNW, 24, 43N, 77W AWAO

- Cuisine CS Federal 1 49-005-59807 Big George 1510' SWNE, 20, 43N, 76W AWAO

- Cuisine CS Federal 2 49-005-59806 Big George 1535' NESE, 20, 43N, 76W AWAO

- Cuisine CS Federal 3 49-005-57549 Big George 1550' SWSE, 20, 43N, 76W AWAO

- Mixer CS Federal 1 49-019-28542 Big George 1565' NESW, 19, 43N, 76W AWAO

- Mixer CS Federal Com 2 49-019-28541 Big George 1510' SWSW, 19, 43N, 76W AWAO

- Eberhart CS Federal 1 49-019-28546 Big George 1695' NENW, 20, 44N, 77W AWAO

- Eberhart CS Federal 2 49-019-28545 Big George 1635' SWNW, 20, 44N, 77W AWAO

- Aileron CS Federal 1 49-019-28543 Big George 1550' NENE, 33, 44N, 77W AWAO

- Aileron CS Federal 2 49-019-28544 Big George 1480' SWNE, 33, 44N, 77W AWAO

- Bullwhacker CS State 1 49-019-21763 Big George 1135' NESE, 32, 44N, 77W AWAO

- Bullwhacker CS State 2 49-019-22925 Big George 1440' SWNE, 32, 44N, 77W AWAO

- Beecher Draw CS State 1 49-019-22034 Big George 1670' NENE, 36, 44N, 77W AWAO

- Beecher Draw CS State 2 49-019-22033 Big George 1500' NENW, 36, 44N, 77W AWAO

- Beecher Draw CS State 3 49-019-22032 Big George 1499' SWNW, 36, 44N, 77W AWAO

- Beecher Draw CS State 4 49-019-22031 Big George 1540' SWNE, 36, 44N, 77W AWAO

- Beecher Draw CS State 5 49-019-22030 Big George 1730' NESE, 36, 44N, 77W AWAO

- Beecher Draw CS State 6 49-019-22029 Big George 1640' NESW, 36, 44N, 77W AWAO

- Beecher Draw CS State 7 49-019-22028 Big George 1650' SWSW, 36, 44N, 77W AWAO

- Beecher Draw CS State 8 49-019-22027 Big George 1660' SWSE, 36, 44N, 77W AWAO

Use format provided. Additional sheets may be included if necessary. AWAO = “all wells to all outfalls”

Total Number of Wells 47

Page 13: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/30/Renewal Application/ HUC1009020202/WY0056502 Page 12 of 14

TABLE 3: RESERVOIR INFORMATION

Desired

Changes

(modifications

and renewals

only)

Reservoir

Name

Reservoir

Storage

Volume

(acre/feet)

SEO

Permit #

SEO Reservoir

Requirements

Legal Location

(QQ, Section Township, Range)

Geographic Location

(Latitude and Longitude,

Decimal Degrees)

Quarter-

Quarter Section Township Range Latitude Longitude

Dune 19.6 P18794S -- NWNW 16 43 76 43.70534536 -106.00729779

Thumper 15.8 18691S

Reclaim once facility

ceases to receive

CBNG discharges

SWSE 16 43 76 43.69601459 -105.99630800

Tex 12.5 18615S

Reclaim once facility

ceases to receive

CBNG discharges

NENW 18 43 76 43.70593806 -106.04162585

Remove

Reservoir Zink 19.9 18732S

Reclaim once facility

ceases to receive

CBNG discharges

NWSE 18 43 76 43.69659323 -106.03753019

Bull Pasture #3 12.1 18653S

Reclaim once facility

ceases to receive

CBNG discharges

NENW 9 43 76 43.71963101 -106.00155334

Bull Pasture #4 15.6 18733S

Reclaim once facility

ceases to receive

CBNG discharges

NENE 17 43 76 43.70502605 -106.00981196

Additional spaces/tables may be included as necessary. Use the format provided. Please note that reservoir information is not required if reservoir containment is not part of the facility’s water

management plan – for instance, information about existing “incidental” downstream reservoirs is not required.

Page 14: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/30/Renewal Application/ HUC1009020202/WY0056502 Page 13 of 14

Table 4: Bonding Information Table

Please check only one “reservoir reclamation

volume” box for each reservoir.

Desired

Changes

(modifications

and renewals

only)

Reservoir

Name

Reservoir

Bonding

Authority

(BLM,

WDEQ,

WOGCC, or

OSLI)

Reservoir

Reclamation

Volume* less

than 5000

cubic yards?

Reservoir

Reclamation

Volume*

between 5000

and 10, 000

cubic yards?

Reservoir

Reclamation

Volume*

greater than

10, 000 cubic

yards?

Reservoir

constructed prior

to September 1,

2005?

Bond currently posted

with bonding

authority?

Dune WDEQ X No Yes

Thumper WDEQ X No Yes

Tex WDEQ X No Yes

Bull Pasture #3 BLM X No Yes

Bull Pasture #4 WDEQ X No Yes

*”Reservoir reclamation volume” is the volume of backfill and/or topsoil needed to fill reservoir upon reclamation, in cubic yards. This can also be measured in the amount of material that was excavated to

create the reservoir. Please note that reservoir information is not required if reservoir containment is not part of the facility’s water management plan – for instance, information about existing “incidental”

downstream reservoirs is not required.

Page 15: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

EOG Y Resources, Inc.: 2018/April/30/Renewal Application/ HUC1009020202/WY0056502 Page 14 of 14

TABLE 5. Assimilative Capacity Information for Direct Discharges Within Powder River Hydrologic

Basin Only*

* DIRECT DISCHARGES means those discharges that are not or are only partially contained within reservoirs. Discharges to

reservoirs that only overtop and spill during storm events are not subject to assimilative capacity requirements. Direct discharges

that can meet Powder River ambient concentrations for TDS and sodium are also not subject to assimilative capacity requirements.

This table ONLY needs to be completed for applications requesting Option 2 direct discharges located within the Powder River

hydrologic basin that cannot meet Powder River ambient concentrations for TDS and sodium for all months of the year.

Assimilative capacity for monthly planned reservoir releases will be evaluated at the time that the permittee applies for the monthly

release authorization; this table does NOT need to be completed for monthly reservoir release situations.

1. List all outfalls that are requested for direct discharge:

2. Please indicate, for both total dissolved solids and dissolved sodium, the pounds per month (“credits”)

the permittee wishes to allocate to this permit (i.e. what portion of the total assimilative capacity

available to the permittee will be issued to this permit for each month?).

Constituent Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

TDS (lb/mo)

Dissolved

Na (lb/mo)

3. Please indicate, for each month of the year, what the expected water quality concentrations for TDS

and dissolved sodium (in mg/l) and the expected flow volumes (in millions of gallons per month), will be

for this facility:

Constituent Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

TDS (mg/l)

Dissolved

Na (mg/l)

Flow,

(MG/month)

4. Please provide a brief description of the source of information used to determine concentrations and

flow volumes listed in item #3 above:

5. Does the applicant intend to treat water at this facility to meet the concentrations provided in item #3

above? □ Yes □ No

6. Please indicate, for the months of August and September when no assimilative capacity is available to

any operator, how the applicant will manage water such that no additional salt loads are contributed

to the Powder River (i.e. contain all discharges in reservoir(s) up to storm event, treat effluent from

direct discharge outfalls to Powder River ambient concentration, cease discharge from these outfalls

for these two months, etc.):

Page 16: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

Analyses Result Units Analysis Date / ByRL Method

LABORATORY ANALYTICAL REPORT

Client Sample ID WY0056502-005 Collection Date: 04/15/10 11:40

Matrix: Aqueous

Client: Yates Petroleum Corp

Lab ID: G10040479-001

Report Date: 05/06/10

Date Received: 04/15/10Location:

Sampled By: David Clink

Qualifier

Samp FRQ/Type

Project: Not Indicated

ENERGY LABORATORIES, INC. * 400 W Boxelder Rd * Gillette, WY 82718-5315

Toll Free 866.686.7175 * 307.686.7175 * FAX 307.682.4625 * [email protected]

Result Units

FIELD PARAMETERS

04/15/10 11:40 / ***s.u.pH, field FIELD7.92

*** Performed by Sampler

MAJOR IONS, DISSOLVED

04/16/10 19:22 / wrwmg/LBicarbonate as HCO3 A2320 B34.22080 5 meq/L

04/20/10 12:14 / wrwmg/LChloride E300.00.217 1 meq/L

04/20/10 12:14 / wrwmg/LFluoride E300.00.061.1 0.1 meq/L

04/20/10 12:14 / wrwmg/LSulfate E300.0<0.02ND 1 meq/L

04/20/10 01:53 / eli-bmg/LCalcium E200.72.2946 1 meq/L

04/20/10 01:53 / eli-bmg/LMagnesium E200.72.7634 1 meq/L

04/20/10 01:53 / eli-bmg/LPotassium E200.70.9738 1 meq/L

D 04/20/10 01:53 / eli-bmg/LSodium E200.729.7682 2 meq/L

METALS, DISSOLVED

04/20/10 19:51 / eli-bug/LAluminum E200.8ND 50

04/20/10 01:53 / eli-bug/LBoron E200.7183 100

04/20/10 19:51 / eli-bug/LCadmium E200.8ND 0.1

04/20/10 19:51 / eli-bug/LChromium E200.82 1

04/20/10 19:51 / eli-bug/LCopper E200.8ND 1

04/20/10 01:53 / eli-bug/LIron E200.779 30

04/20/10 19:51 / eli-bug/LLead E200.8ND 2

04/20/10 01:53 / eli-bug/LManganese E200.728 10

04/20/10 19:51 / eli-bug/LMercury E200.8ND 0.06

04/20/10 01:53 / eli-bug/LNickel E200.7ND 10

04/20/10 19:51 / eli-bug/LSilver E200.8ND 3

04/20/10 01:53 / eli-bug/LZinc E200.7ND 10

METALS, TOTAL

04/21/10 01:05 / eli-bug/LBarium E200.81700 100

04/21/10 01:05 / eli-bug/LIron E200.8589 30

04/21/10 01:05 / eli-bug/LManganese E200.823 10

METALS, TOTAL RECOVERABLE

04/22/10 07:30 / eli-bug/LAluminum E200.8ND 50

04/21/10 01:05 / eli-bug/LAntimony E200.8ND 5

04/21/10 01:05 / eli-bug/LArsenic E200.81.5 0.5

04/21/10 01:05 / eli-bug/LBeryllium E200.8ND 0.03

04/22/10 07:30 / eli-bug/LSelenium E200.8ND 5

04/21/10 01:05 / eli-bug/LThallium E200.8ND 1

Report

Definitions:

RL - Analyte reporting limit. MCL - Maximum contaminant level.

QCL - Quality control limit. ND - Not detected at the reporting limit.

D - RL increased due to sample matrix interference.

Page 17: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

Analyses Result Units Analysis Date / ByRL Method

LABORATORY ANALYTICAL REPORT

Client Sample ID WY0056502-005 Collection Date: 04/15/10 11:40

Matrix: Aqueous

Client: Yates Petroleum Corp

Lab ID: G10040479-001

Report Date: 05/06/10

Date Received: 04/15/10Location:

Sampled By: David Clink

Qualifier

Samp FRQ/Type

Project: Not Indicated

ENERGY LABORATORIES, INC. * 400 W Boxelder Rd * Gillette, WY 82718-5315

Toll Free 866.686.7175 * 307.686.7175 * FAX 307.682.4625 * [email protected]

Result Units

NON-METALS

04/16/10 19:22 / wrwmg/LAlkalinity, Total as CaCO3 A2320 B1760 5

04/16/10 10:29 / klrumhos/cmConductivity @ 25 C A2510 B2930 10

04/20/10 13:42 / eli-bug/LCyanide, Total Kelada modND 5

04/22/10 15:42 / clbmg/LHardness as CaCO3 A2340 B250 10

04/19/10 12:26 / eli-bmg/LPhenolics, Total Recoverable (Distilled) E420.4ND 0.01

04/22/10 15:42 / clbunitlessSodium Adsorption Ratio (SAR) Calculation18.7 0.1

04/20/10 10:22 / mlimg/LSolids, Total Dissolved TDS @ 180 C A2540 C1850 20

04/23/10 08:51 / djkmg/LTotal Petroleum Hydrocarbons E1664AND 1.0

RADIONUCLIDES - TOTAL

05/03/10 14:13 / eli-cpCi/LRadium 226 E903.00.61

05/03/10 14:13 / eli-cpCi/LRadium 226 precision (±) E903.00.20

05/03/10 14:13 / eli-cpCi/LRadium 226 MDC E903.00.12

U 04/28/10 14:29 / eli-cpCi/LRadium 228 RA-05-0.10

04/28/10 14:29 / eli-cpCi/LRadium 228 precision (±) RA-050.86

04/28/10 14:29 / eli-cpCi/LRadium 228 MDC RA-050.90

U 05/04/10 16:26 / eli-cpCi/LRadium 226 + Radium 228 A7500-RA0.51

05/04/10 16:26 / eli-cpCi/LRadium 226 + Radium 228 precision (±) A7500-RA0.44

05/04/10 16:26 / eli-cpCi/LRadium 226 + Radium 228 MDC A7500-RA0.91

DATA QUALITY

04/22/10 15:39 / clb%A/C Balance A1030 E0.28

04/22/10 15:39 / clbmeq/LAnions A1030 E35.5 0.01

04/22/10 15:39 / clbmeq/LCations A1030 E35.7 0.01

Report

Definitions:

RL - Analyte reporting limit. MCL - Maximum contaminant level.

QCL - Quality control limit. ND - Not detected at the reporting limit.

MDC - Minimum detectable concentration U - Not detected at minimum detectable concentration

Page 18: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

JOHN

SON

COUN

TYCA

MPBE

LLCO

UNTY

R. 77 W. R. 76 W.

T.44N.

T.43N.

R. 77 W. R. 76 W.EBERHART CS

FEDERAL 1

AILERON CSFEDERAL 1

AILERON CSFEDERAL 2

BLADE CSFEDERAL 5

MIXER CSFEDERAL 1

MIXER CSFEDERAL COM 2

CUISINE CSFEDERAL 1

BULLWHACKER CSSTATE 2

SPATULA CSSTATE 1

E. 240000

E. 240000

E. 245000

E. 245000

E. 250000

E. 250000

E. 255000

E. 255000

E. 260000

E. 260000

E. 265000

E. 265000

E. 270000

E. 270000

E. 275000

E. 275000

E. 280000

E. 280000

N.

1100

000

N.

1100

000

N.

1105

000

N.

1105

000

N.

1110

000

N.

1110

000

N.

1115

000

N.

1115

000

N.

1120

000

N.

1120

000

N.

1125

000

N.

1125

000

N.

1130

000

N.

1130

000

N.

1135

000

N.

1135

000

ROLLING PINCS STATE 1

ROLLING PINCS STATE 2

SPATULA CSSTATE 2

SPATULA CSSTATE 4SPATULA CS

STATE 3

SPATULA CSSTATE 5

SPATULA CSSTATE 6

CUISINE CSFEDERAL 2

CUISINE CSFEDERAL 3

BLADE CSFEDERAL 7BLADE CS

FEDERAL 6

BLADE CSFEDERAL 9

BLADE CSFEDERAL 10

BLADE CSFEDERAL COM 12

BLADE CSFEDERAL 8

BLADE CSFEDERAL 13

BLADE CSFEDERAL COM 15

BLADE CSFEDERAL 14

BLADE CSFEDERAL 11

BLADE CSFEDERAL COM 17

BLADE CSFEDERAL 16

BLADE CSFEDERAL 18

BLADE CSFEDERAL 19

BLADE CSFEDERAL 20

BLADE CSFEDERAL 1

BLADE CSFEDERAL 2

BLADE CSFEDERAL 3

BLADE CSFEDERAL 4

BEECHER DRAWCS STATE 2

BEECHER DRAWCS STATE 1

BEECHER DRAWCS STATE 4BEECHER DRAW

CS STATE 3

BEECHERDRAW CSSTATE 6

BEECHER DRAWCS STATE 5

BEECHERDRAW CSSTATE 7

BEECHERDRAW CSSTATE 8

BULLWHACKER CSSTATE 1

EBERHART CSFEDERAL 2

Thumper15.8 a.f.

Tex12.5 a.f.

Dune19.6 a.f.

Bull Pasture#4

15.6 a.f.

Bull Pasture#3

12.1 a.f.

005

004

003

002

001

T.44N.

T.43N.

LEGEND

WATER DISCHARGE LINE

PERMITTED WATER DISCHARGE

PERMITTED RESERVOIR

PERMITTED FEDERAL CBNG WELL LOCATION

PERMITTED STATE CBNG WELL LOCATION

STOCK TANK

50

192

TRIB1UPR

DPR

T.45N.

T.46N.

T.44N.

T.43N.

T.47N.

PROJECT AREAVIEW FRAME(EXHIBIT 1)

DOWNSTREAM MONITORING LOCATIONSVIEW FRAME (EXHIBIT 2)

R. 74 W.R. 75 W.R. 76 W.R. 77 W.R. 78 W.

T.45N.

T.46N.

T.44N.

T.43N.

T.47N.

R. 74 W.R. 75 W.R. 76 W.R. 77 W.R. 78 W.

R. 79 W.

R. 79 W.

Pumpkin Creek

Pow

der

Rive

r

Wil low

Creek

Dry Fork Powder River

IMP2

IMP3

IMP4

LOCATION MAPSCALE: 1" = 6 MILES

PROJECT AREASCALE: 1" = 2000'

SHERIDAN, WY. 82801(307) 672-0761

1849 TERRA AVE.

Page 19: WYPDES Permit Section 200 W. 17th St. 4th Floordeq.state.wy.us/.../FP_0056001-0058000/WY0056502_REN_2018-051… · EOG is applying for renewal of existing WYPDES permit WY056502,

LEGENDMONITORING LOCATION

T.44N.

R. 78 W.

E. 210000

E. 210000

E. 215000

E. 215000

E. 220000

E. 220000

N.

1135

000

N.

1135

000

N.

1140

000

N.

1140

000

N.

1145

000

N.

1145

000

T.44N.

R. 78 W.

UPR

DPR

TRIB1

E. 225000

E. 225000

50

192

TRIB1UPR

DPR

T.45N.

T.46N.

T.44N.

T.43N.

T.47N.

PROJECT AREAVIEW FRAME(EXHIBIT 1)

DOWNSTREAM MONITORING LOCATIONSVIEW FRAME (EXHIBIT 2)

R. 74 W.R. 75 W.R. 76 W.R. 77 W.R. 78 W.

T.45N.

T.46N.

T.44N.

T.43N.

T.47N.

R. 74 W.R. 75 W.R. 76 W.R. 77 W.R. 78 W.

R. 79 W.

R. 79 W.

Pumpkin Creek

Pow

der

Rive

r

Wil low

Creek

Dry Fork Powder River

IMP2

IMP3

IMP4

DOWNSTREAM MONITORING LOCATIONSSCALE: 1" = 2000'

LOCATION MAPSCALE: 1" = 6 MILES

SHERIDAN, WY. 82801(307) 672-0761

1849 TERRA AVE.