April 2021

X-IE-GDATA SHEETInsulation fastener

Page 2: X-IE-G DATA SHEET - hilti.com.om

04/2021 2www.hilti.group

X-IE-G

X-IE-G 6 and X-IE-G 9 insulation fasteners

Product data

X-IE-G 6 Product description• Suitable for a wide range of insulation materials –

Soft mineral wool, mineral wool, EPS, XPS, PIR, PUR, soft core multilayer board, rigid core multilayer board

• Suitable for 25–200 mm thick insulation• Very high thermal efficiency in a one-step solution• No holes in the fastener shank – helping prevent mold and

moisture penetration in the insulation material• Gauge included for easy visual control of correct fastener

driving depth• Specially-designed 90 mm disc diameter for soft mineral

wool, providing excellent clamping of the insulationX-IE-G 9

Dimensions

Ø

Ls

Designation Diameter Ø Nail length L sX-IE-G 6 60 mm 36 mmX-IE-G 9 90 mm 36 mm

Material properties for plastic parts

Element Designation Material Color Other propertiesPlate X-IE-G 6 HDPE Colorless UV stabilized materialPlate X-IE-G 9 HDPE Black UV stabilized material

Page 3: X-IE-G DATA SHEET - hilti.com.om

3 04/2021www.hilti.group

X-IE-G

Material properties for carbon steel parts

Element Designation Material Coating Minimum coating thickness

Hardness

Nail X-P 36 G3 Carbon steel Zinc 2 µm 57.5 HRC

Applications

Curtain wall insulation Ceiling insulation Basement perimeterinsulation

Base materials

Solid sand- lime masonry

Solid brick

Approvals and certificates

Authority Approval / certificate no. Date of issue Country of issueSocotec 180668080000010 09/ 2018 France

Not all information presented in this product data sheet might be subject to approval / certificate content. Please refer to approval / certificate for further information.

Soft concrete

Medium concrete

Page 4: X-IE-G DATA SHEET - hilti.com.om

04/2021 4www.hilti.group

X-IE-G

• The intended use comprises fastening in dry conditions.

• During construction, exposure to UV due to solar radiation of the fixing element not protected by rendering shall not exceed the time of 6 weeks.

• The temperature during installation of the fixing element shall not be less than 5 °C.

Load condition

Environmental conditions

Staticquasi-static

• Soft core multilayer board: hard top layer with insulation core of mineral wool • Rigid core multilayer board: hard top layer with insulation core of EPS, XPS, PIR,

PUR

Fastened materials

Soft mineral wool

Mineral wool

EPS XPS PIR, PUR

Soft and rigid core multilayer board

Application requirements

Fastened material properties

tI

Fastened material

Compressive strength

Fastened material thickness tl

Soft mineral wool < 500 kN / m2 25–200 mmMineral wool < 500 kN / m2 25–200 mmEPS, XPS, PIR, PUR, soft core multilayer board

< 500 kN / m2 25–200 mm

Rigid core multilayer board < 500 kN / m2 19–197 mm

Page 5: X-IE-G DATA SHEET - hilti.com.om

5 04/2021www.hilti.group

X-IE-G

Fastener edge distance and spacing in base material

cs

sc

ce

c e

Minimum corner distance ce

Minimum edge distance c

Minimum fastener spacing distance s

100 mm 75 mm 100 mm

Number of fasteners per m²

Fastened material Fastened material weight Minimum number of fasteners per m²

Soft mineral wool, mineral wool, EPS, XPS, PIR, PUR,soft core multilayer board, rigid core multilayer board

< 50 kg/m2 450–75 kg/m2 5> 75 kg/m² 7

Fastened material Fastened material density Minimum number of fasteners per m²

Soft mineral wool, mineral wool, EPS, XPS, PIR, PUR,soft core multilayer board, rigid core multilayer board

< 10 kg/m3 410–15 kg/m3 5> 15 kg/m3 7

Please consult insulation material supplier

Fastener edge distance and spacing in insulation material

Base material properties

tII

Base material Base material strength

Base material thickness tII

Soft, medium concrete fcc = 15–45 N / mm2 ≥ 80 mm

Tough concrete fcc = 45–65 N / mm2 ≥ 80 mmSolid sand-lime masonry fb = 15–45 N / mm2 –

Solid brick fb = 28–45 N / mm2 –Steel fu = 360–450 N / mm2 4–6 mm

Page 6: X-IE-G DATA SHEET - hilti.com.om

04/2021 6www.hilti.group

X-IE-G

Performance data

Recommended resistance under tension and shear load

N

V

Base material TensionNrec

ShearVrec

Soft, medium concrete 0.1 kN 0.1 kNSolid sand-lime masonry 0.1 kN 0.1 kNSolid brick 0.1 kN 0.1 kN

• For more details in relation to base material properties, please refer to the chapter

Fastener selection guide in the Direct Fastening Technology Manual (DFTM). • The above data value for solid sand-lime masonry and solid brick are based on

laboratory and field experience. Because of the wide variety of types and forms of masonry in use worldwide, users are advised to carry out tests on site or on masonry of the type and form on which the fastenings are to be made.

• The above data refers to the fastener pull-out failure mode. • For pull-over under tension load please consult insulation material supplier.

Stick rate estimation

Designation Soft, medium concrete15 ≤ fc,cube ≤ 45 N / mm2

X-IE-G 6, X-IE-G 9 Up to 90 %

The stick rate indicates the percentage of nails that were driven correctly to carry a load. Stick rate can vary from the above values depending on job site conditions

Thermal efficiency according to EOTA TR 025

Application Insulation thicknesstI

Point thermal transmittanceϰ

Curtain wall insulation 60–90 mm 0.002 W/K100–200 mm 0.001 W/K

Ceiling insulation 60–90 mm 0.002 W/K100–200 mm 0.001 W/K

Basement perimeter insulation

60 mm 0.003 W/K70–100 mm 0.002 W/K120–200 mm 0.001 W/K

Page 7: X-IE-G DATA SHEET - hilti.com.om

7 04/2021www.hilti.group

X-IE-G

■ = recommended, ■ = feasible

Designation Tools Gas can

GX-IE GX-IE XL GC 52

X-IE-G 6X-IE-G 6-25 X-IE-G 6-140 ■ ■ ■X-IE-G 6-150 X-IE-G 6-200 ■ ■

X-IE-G 9X-IE-G 9-40 X-IE-G 9-140 ■ ■ ■X-IE-G 9-150 X-IE-G 9-200 ■ ■

System recommendation

Tool and energy recommendation

• For more details, please refer to the chapter Accessories and consumables compatibility in the Direct Fastening Technology Manual (DFTM).

Page 8: X-IE-G DATA SHEET - hilti.com.om

04/2021 8www.hilti.group

X-IE-G

Fastener selection

Fastened material Insulation thickness tI

Designation Nail Item number

Soft mineral wool

40 mm X-IE-G 9-40 X-P 36 G3 217215450 mm X-IE-G 9-50 X-P 36 G3 217215560 mm X-IE-G 9-60 X-P 36 G3 217215680 mm X-IE-G 9-80 X-P 36 G3 2172157100 mm X-IE-G 9-100 X-P 36 G3 2172158120 mm X-IE-G 9-120 X-P 36 G3 2172159140 mm X-IE-G 9-140 X-P 36 G3 2163823150 mm X-IE-G 9-150 X-P 36 G3 2192919160 mm X-IE-G 9-160 X-P 36 G3 2163824180 mm X-IE-G 9-180 X-P 36 G3 2163825200 mm X-IE-G 9-200 X-P 36 G3 2163826

Fastened material Insulation thickness tI

Designation Nail Item number

Mineral wool, EPS, XPS, PIR, PUR, soft core multilayer board

25 mm X-IE-G 6-25 X-P 36 G3 219291430 mm X-IE-G 6-30 X-P 36 G3 216381040 mm X-IE-G 6-40 X-P 36 G3 221251450 mm X-IE-G 6-50 X-P 36 G3 221251560 mm X-IE-G 6-60 X-P 36 G3 216381370 mm X-IE-G 6-70 X-P 36 G3 216381475 mm X-IE-G 6-75 X-P 36 G3 219291580 mm X-IE-G 6-80 X-P 36 G3 216381590 mm X-IE-G 6-90 X-P 36 G3 2192916100 mm X-IE-G 6-100 X-P 36 G3 2163816120 mm X-IE-G 6-120 X-P 36 G3 2192917130 mm X-IE-G 6-130 X-P 36 G3 2192918140 mm X-IE-G 6-140 X-P 36 G3 2163817150 mm X-IE-G 6-150 X-P 36 G3 2163818160 mm X-IE-G 6-160 X-P 36 G3 2163819180 mm X-IE-G 6-180 X-P 36 G3 2163820200 mm X-IE-G 6-200 X-P 36 G3 2163821

Page 9: X-IE-G DATA SHEET - hilti.com.om

9 04/2021www.hilti.group

X-IE-G

Fastened material Insulation thickness tI

Designation Nail Item number

Rigid core multilayer board

19–22 mm X-IE-G 6-25 X-P 36 G3 219291424–27 mm X-IE-G 6-30 X-P 36 G3 216381034–37 mm X-IE-G 6-40 X-P 36 G3 221251444–47 mm X-IE-G 6-50 X-P 36 G3 221251554–57 mm X-IE-G 6-60 X-P 36 G3 216381364–67 mm X-IE-G 6-70 X-P 36 G3 216381469–72 mm X-IE-G 6-75 X-P 36 G3 219291574–77 mm X-IE-G 6-80 X-P 36 G3 216381584–87 mm X-IE-G 6-90 X-P 36 G3 219291694–97 mm X-IE-G 6-100 X-P 36 G3 2163816114–117 mm X-IE-G 6-120 X-P 36 G3 2192917124–127 mm X-IE-G 6-130 X-P 36 G3 2192918134–137 mm X-IE-G 6-140 X-P 36 G3 2163817144–147 mm X-IE-G 6-150 X-P 36 G3 2163818154–157 mm X-IE-G 6-160 X-P 36 G3 2163819174–177 mm X-IE-G 6-180 X-P 36 G3 2163820194–197 mm X-IE-G 6-200 X-P 36 G3 2163821

• Insulation board thickness tolerance: ±3 mm

• Soft mineral wool, mineral wool: for intermediate thicknesses use next shorter fastener, example: for mineral wool insulation thickness 110 mm, use X-IE 6-100

• EPS, XPS, PIR, PUR, soft core multilayer board: for intermediate thicknesses use next longer fastener, example: for PIR insulation thickness 110 mm, use X-IE 6-120

• Rigid core multilayer board: for thicknesses not specified, please contact Hilti

Page 10: X-IE-G DATA SHEET - hilti.com.om

04/2021 10www.hilti.group

X-IE-G

Fastening inspection

tI

x hET Designation Embedment depth hET

Distance between nail head and X-IE plate x

X-IE-G 6-25 12 – 19 mm 3 – 10 mmX-IE-G 6-30 12 – 19 mm 3 – 10 mmX-IE-G 6-40, X-IE-G 9-40 12 – 19 mm 14 – 21 mmX-IE-G 6-50, X-IE-G 9-50 12 – 19 mm 24 – 31 mmX-IE-G 6-60, X-IE-G 9-60 12 – 19 mm 34 – 41 mmX-IE-G 6-70 12 – 19 mm 44 – 51 mmX-IE-G 6-75 12 – 19 mm 49 – 56 mmX-IE-G 6-80, X-IE-G 9-80 12 – 19 mm 54 –  61 mmX-IE-G 6-90 12 – 19 mm 64 – 71 mmX-IE-G 6-100, X-IE-G 9-100 12 – 24 mm 74 – 81 mmX-IE-G 6-120, X-IE-G 9-120 12 – 24 mm 94 – 100 mmX-IE-G 6-130 12 – 24 mm 104 – 111 mmX-IE-G 6-140, X-IE-G 9-140 12 – 24 mm 114 – 121 mmX-IE-G 6-150, X-IE-G 9-150 12 – 24 mm 124 – 131 mmX-IE-G 6-160, X-IE-G 9-160 12 – 24 mm 134 – 141 mmX-IE-G 6-180, X-IE-G 9-180 12 – 24 mm 154 – 161 mmX-IE-G 6-200, X-IE-G 9-200 12 – 24 mm 174 – 181 mm

Fastening quality assurance

Page 11: X-IE-G DATA SHEET - hilti.com.om

11 04/2021www.hilti.group

X-IE-G

Setting depth control and power tool adjustment

Check setting depth with the gaugeimmediately after fastening

• Visible setting failures must be replaced with a new fastener, not in the same hole

• These are abbreviated instructions which may vary by application. • ALWAYS review / follow the instructions accompanying the product