x-ray production: sources and optics r.m. sweet brookhaven biology

Download X-Ray Production: Sources and Optics R.M. Sweet Brookhaven Biology

If you can't read please download the document

Upload: sabastian-kettlewell

Post on 15-Dec-2015

218 views

Category:

Documents


2 download

TRANSCRIPT

  • Slide 1

X-Ray Production: Sources and Optics R.M. Sweet Brookhaven Biology Slide 2 Plan for the lecture: I. Considerations in the choice of an x-ray source A. Resolve the spots B. Optimize accuracy (decrease error) II. Types of Source A. Sealed tube and rotating Anode B. Synchrotron III. X-Ray Optics A. Monochromatization B. Collimation C. Focussing Slide 3 Considerations in the choice, or design, of an x-ray beam for a diffraction experiment. What should the source look like? How do we condition the beam: Monochromators? Focussing? Slits? How should the beam match the properties of the specimen? Slide 4 What are the goals of the crystallographic experiment? Bring all Bragg planes into diffracting position Integrate the diffraction intensity from each set of Bragg planes Over the volume of the crystal Over the crossfire of the x-ray beam Over the mosiac nature of the crystal To accomplish this, we must resolve the reflected beams: On the surface of the x-ray detector Throughout any rotation of the crystal Slide 5 Heres an example of the problem! The longest unit-cell edge is 570 in this photo from crystals of the Nobel-Prize winning 50S ribosomal subunit project. Ban, et al, Cell 1998 Slide 6 Lets look at it in detail: Ban, et al, Cell 1998 Blow this up Slide 7 The spots almost touch. Their length comes from the horizontal divergence of the focussed beam The kidney shape comes from defects in the optics. Ban, et al, Cell 1998 Slide 8 Consider the diffraction one would get from a perfect infinitesimal (point) crystal and a point source of x-rays... Rotation Intensity Detector Surface Source of x-rays The Crystal The crystal diffracts only at one position, and the diffracted beam is thin on the detector. rotate Slide 9 Next, consider diffraction from a finite perfect crystal and a point source of x-rays.. Rotation Intensity Detector Surface Source of x-rays The Crystal One must rotate the crystal to allow first its top and then its bottom to see the source. F s The total angle of reflection is = s / (F + ) s / Slide 10 There are perfect crystals, and then there are mosaic crystals Perfect Mosaic If the rays coming in are perfectly parallel, the whole block of the perfect crystal will diffract, but only those blocks of the mosaic crystal that are aligned with the beam will diffract. To get all of the mosaic crystal to diffract, one must: Use an x-ray beam with crossfire, or Rotate the crystal in the beam. Slide 11 Now, consider diffraction from a finite mosaic crystal and a point source of x-rays.. Rotation Intensity Detector Surface Source of x-rays The Crystal The crystal must be rotated over an even wider range of positions, producing a diffracted beam that is the same size on the detector, but is wider in rotation. F s The total angle of reflection is = s / + (F + ) s / Slide 12 Finally, consider a finite mosaic crystal and a finite source of x-rays. Rotation Intensity Detector Surface Source of x-rays The Crystal The crystal diffracts over an even wider range of positions, and now the beam on the detector is wider. F s The total angle of reflection is = (s + f) / + f (F + ) s / + F f / Slide 13 Lets think about spot size and spot separation. On the previous drawing we had that the spot size was: (F + ) s / + F f / = s + (s + f) F/ Notice that this (s + f) / term represents all of the crossfire of the beam, whatever the source Well call it . So the spot size becomes s + F Slide 14 1 / 1 / d F / d F / d Therefore, to resolve spots, we must have that the spacing is greater than the size: F / d > s + F F [ / d - ] > s F > s / [ / d - ] One can see that this will work as long as the beam crossfire is small enough!! Slide 15 Plan for the lecture: I. Considerations in the choice of an x-ray source A. Resolve the spots B. Optimize accuracy (decrease error) II. Types of Source A. Sealed tube and rotating Anode B. Synchrotron III. X-Ray Optics A. Monochromatization B. Collimation C. Focussing Slide 16 Accuracy - I: Statistical Precision With photon counting, var (I) = 2 (I) = I For example, relative error is the standard deviation / the measured intensity = (I)/I = 1/I 1/2 Therefore, for I = 10 4, (I)/I = 0.01 (1% error) There must be sufficient photons to provide the statistical precision one wants. The signal must be strong enough to rise above the noise in the counting system and other sources of background noise. Slide 17 How can we minimize background noise? Detector noise and x-ray background The integrated intensity we seek: I Total scanned intensity: S Intensity Scan Intensity Scan The portion of the background that must be subtracted from the scan: B We have: I = S - B Standard error propagation gives 2 I = 2 S + 2 B Since I, B, and S all are counts, 2 S = S, 2 B = B This gives: I / I = (S - B) / (S + B) 1/2 It pays to make the reflection sharp. One wants a bright source! {Photons / (time, area, wavlelength bandwidth, crossfire)} Slide 18 Detective Quantum Efficiency DQE is a useful concept for assessing the quality of a data- collection system. Define efficiency as the double ratio: the squared output signal-to-noise (including background and detector noise) against the ideal signal-to-noise. If the output is simply a count attenuated by some factor, say the efficiency of absorption, we can see the term Efficiency makes sense. Slide 19 So any change in an experimental system that decreases B, whether its x-ray background or instrumental noise, improves the efficiency of this system. Evaluate DQE for an Integrated Intensity Slide 20 Ways to Decrease the Background Make the specimen mount as small as possible Use a beam no larger than the specimen Place the beamstop as close to the specimen as practicable Move the detector as far from the crystal as possible, consistent with the resolution you desire Slide 21 Accuracy - II: Minimize Systematic Errors Specimen damage: One will see usually uncorrectable variation in data Resolution limit decreases Freezing the crystal helps Consider using several x-tals with shorter total exposures on each Absorption errors: Watch for high salt solutions Make freezing loops as small as possible Because absorption varies as 3 while scattering varies as 2, it pays to use a shorter wavelength. Slide 22 Plan for the lecture: I. Considerations in the choice of an x-ray source A. Resolve the spots B. Optimize accuracy (decrease error) II. Types of Source A. Sealed tube and rotating Anode B. Synchrotron III. X-Ray Optics A. Monochromatization B. Collimation C. Focussing Slide 23 Conventional Sources of X-Rays Conventional x-ray sources depend on a beam of electrons, drawn from a hot filament by a high voltage field. The electrons strike an anode, usually made from a pure elemental metal, driving an electron from an atomic orbital. The emitted radiation depends on the fluorescence spectrum of the emitting element. Anode Cathode ~10V ~40kV + - Slide 24 E.W. Nuffield (1966) X-Ray Diffraction Methods Pseudo-Monochromatic X-Rays There is typically a complex series of lines, with K emission being strongest K is a peak that needs to be separated from K Most of low wave-length radiation is removed with a filter that is one atomic number lower than the anode. K 1 and K 2 are distinct emissions. Wavelengths ( ) are: K 1 = 1.54051 K 2 = 1.54433 K ave = 1.5418 K = 1.39217 Slide 25 The Modern Laboratory X- Ray Generator Old-style generators had a fixed anode with water cooling. Modern ones employ a rotating water-cooled anode. The specific loading of this sort of generator can be 4kW of electrical power through a square mm of the anode surface!! Water for cooling Motor drive Rotating anode Rotating seal X-Rays Beryllium window -40 kV relative to the anode Focusing cup Electrons Hot filament Slide 26 Plan for the lecture: I. Considerations in the choice of an x-ray source A. Resolve the spots B. Optimize accuracy (decrease error) II. Types of Source A. Sealed tube and rotating Anode B. Synchrotron III. X-Ray Optics A. Monochromatization B. Collimation C. Focussing Slide 27 The National Synchrotron Light Source The NSLS can produce usable radiation from the dipole, or bending magnets. There are two storage rings producing radiation. The lower-energy ring (750 MeV) produces light from the IR through to soft X-rays. The higher energy ring (2.6 GeV) produces hard X-rays for diffraction studies. Both rings have multi-magnet insertion devices. Slide 28 Dipole Magnet Relativistic Electron Electron trajectory Synchrotron Light The Source of Synchrotron Radiation Induced Electric Vector The harder the bend, and the faster the electrons (higher energy), the shorter the wavelength is of the light. Its like flicking a string! Slide 29 Theres a wide spectrum of x-rays available to us for diffraction studies. Here you see the arc (dipole or bending- magnet) and wiggler sources. Slide 30 This is for dipoles (bending magnets). For undulators, the photons emitted at the little dipoles run along beside the (relativistic) electrons. Courtesy of Wayne Hendrickson Slide 31 Just like the slalom skier see how the snow she disturbs follows along the fall line at about the same speed. Courtesy of Wayne Hendrickson Slide 32 The X25 undulator spectrum. The photons interfere with the electrons, and at each undulation the electrons produce new photons that are a harmonic of the frequency of the original, thus the peaky spectrum you see here. Slide 33 Plan for the lecture: I. Considerations in the choice of an x-ray source A. Resolve the spots B. Optimize accuracy (decrease error) II. Types of Source A. Sealed tube and rotating Anode B. Synchrotron III. X-Ray Optics A. Monochromatization B. Collimation C. Focussing Slide 34 MSC/Rigaku/Osmic, Inc. are making synthetic crystal multilayer systems to be used in synchrotrons and home laboratories. Slide 35 Slight elliptical curvature gives focussing Their confocal system employs a graded multilayer on a curved backing. It gives a nice beam for most crystallographic applications. Fine spacing, high angle Coarse spacing, low angle Slide 36 For a synchrotron source: Rays are nearly parallel Use a perfect crystal Si cut to use the (1,1,1) planes is a good choice Often we use two crystals: One to monochromatize One to deflect the beam back up into the horizontal plane Braggs law determines the wavelength Slide 37 Plan for the lecture: I. Considerations in the choice of an x-ray source A. Resolve the spots B. Optimize accuracy (decrease error) II. Types of Source A. Sealed tube and rotating Anode B. Synchrotron III. X-Ray Optics A. Monochromatization B. Collimation C. Focussing Slide 38 Beam Collimation (Use of Slits) In a classic sense, collimation means to make the rays parallel. We generally use the term to mean limiting the beam and avoiding extra scattered rays. Source of x-rays Specimen Limiting Aperture Guard or Scatter Aperture Beamstop The beamstop must be placed to catch the scatter from the limiting aperture that is missed by the scatter aperture. Slide 39 Plan for the lecture: I. Considerations in the choice of an x-ray source A. Resolve the spots B. Optimize accuracy (decrease error) II. Types of Source A. Sealed tube and rotating Anode B. Synchrotron III. X-Ray Optics A. Monochromatization B. Collimation C. Focussing Slide 40 Beam Focusing (Use of a bent mirror) Although we cant make a lens for x-rays, we can do some optical things by total reflection at very low angles. Physically, its like internal reflection in a prism. These are very low angles: ~ 0.5 deg. One application is Franks (sometimes called Yale) mirrors On your local x-ray generator the distances are ~100mm. Slide 41 Focussing of the X-Ray Beam.. X-Rays come from the synchrotron in a fan. Wed like a more condensed beam of radiation for crystallography One should be able to focus with an ellipsoid of revolution We cant actually manage that, so we make a cylinder, then bend it to the shape of a toroid. Slide 42 Summary I. Careful choice of an x-ray source helps to A. Resolve the spots B. Optimize accuracy (decrease error) II. Several kinds of Source are available A. Sealed tube and rotating Anode B. Synchrotron III. X-Ray Optics condition the beam A. Monochromatization B. Collimation C. Focussing Slide 43 The Future Light Source for the Northeastern US NSLS-II Slide 44 A highly optimized x-ray synchrotron delivering: very high brightness and flux; exceptional beam stability; and a suite of advanced instruments, optics, and detectors that capitalize on these special capabilities. Together, these will enable: ~ 1 nm spatial resolution, ~ 0.1 meV energy resolution, and single atom sensitivity. High Level Description of NSLS-II New Science Nanoscience Life Science Nanocatalysis New Capabilities Nanoprobes Diffraction Imaging Coherent Dynamics Slide 45 A Suite of Structural Biology Beamlines 3PW hutch DW hutch Undulator hutch VUV MX FPFP XRSS XAS MX Slide 46 18 Months Total Schedule Contingency Preliminary Summary Schedule Slide 47 Micro- beam diffraction The modern 3 rd generation sources easily produce beams in the 10 micrometer size range. A few can accomplish 5 micrometers, and ones are being planned in the 1 micrometer range. How might these be useful? Slide 48 Small beams can be used either with very small crystals... 30 m http://www.gmca.anl.gov/MiniBeam_for_WEB.pdf Slide 49 Or to make multiple small-beam exposures at different points on a larger crystal. This strategy minimizes the damage exhibited in the overall diffraction data set from the crystal.