x11cb product sheet back rev4 - tecnova...

2
Can be programmed in the field using Ronan’s Configuration Software Application Local Monitoring Applications EVENT RECORDING ANNUNCIATOR X11CB 28209 Avenue Stanford, Valencia, CA 91355 U.S.A. 800-327-6626 [email protected] www.ronan.com DISPLAY PRODUCTS DIVISION Remote Monitoring with Network Transfer Applications Multiplexing | Alarm Annunciation | Networking | Event Recording

Upload: others

Post on 19-Feb-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

  • Can be programmed in the �eld usingRonan’s Con�guration Software Application

    Local Monitoring Applications

    EVENT RECORDING ANNUNCIATOR

    X11CB

    28209 Avenue Stanford, Valencia, CA 91355 U.S.A. • 800-327-6626 • [email protected] • www.ronan.comDISPLAY PRODUCTS DIVIS ION

    Remote Monitoring with Network Transfer Applications

    Multiplexing | Alarm Annunciation | Networking | Event Recording

  • Chassis:

    • Up to 100 I/O Modules*• Power Supply Filter Module• AUX Relay Modules• Interface and Communication ModuleSystem Size:• Basic Cabinet Module is 3.50 in. (88.90mm) x 3.50 in. (88.90mm)

    Enclosures:• Weather Proof - NEMA 4 (optional) - NEMA 4X (optional) - NEMA 12 (optional)

    • Panel Mount• Surface-mount• 19” Rack-mount

    *Multiple chassis can be connected through CAN bus to share communications capabilities up to a maximum of

    FEATURES

    Alarm Display LEDs:

    • Minimum of 4 LEDs per window• Colors: red, green, yellow, white and blue

    Built-In Diagnostics:

    • Hardware startup• System failure/status

    PUSHBUTTON INPUTS

    • Front Bezel Pushbuttons• Rear Input Terminals• via Network Interface

    - Silence- Acknowledge- Reset- First-Out Reset- LED Test

    • 24 VDC via optional Power Supply

    INTERFACE MODULE

    Communications with the SER/HMI or a Host via a 10/100 Base-T Interface via:

    • Ronan Proprietary Protocol• ModBus/TCP Protocol• DNP 3.0 Protocol via Ronan’s

    X200 REC-UCM-2 (Optional)

    • Alarm module monitoring generates system error with missing module.

    Fully con�gurable via TCP/IP over a network (LAN) using the Ronan Con�guration Software

    ALARM MODULE

    (4) Opto-Isolated Channels per module featuring:

    ENVIRONMENT

    • Operating Temperature - 0 to 60º C (32 to 140ºF)**

    • Storage Temperature - 40 to +85ºC (-40 to +185ºF)

    • Humidity 5-95% RH, non-condensing** Operating at temperatures over 50ºC for more than a few hours at a time will shorten the life of the system. The average

    temperature over life of the system should be