2
Powerful Technology Research grade microscope SWIFT™ 10x faster Raman images Integrated motorized optics/lasers Higher sensitivity deep cooled CCD Higher spectral resolution Full confocality - 500 nm XY Multi-laser options with OneClick operation Expandable platform: AFM, macro sampling, EMCCD The XploRA PLUS incorporates many unique and powerful functions in a reliable, high performance system design, ideally suited to the research and analytical lab. It is fully confocal, not compromising image quality or spatial or depth resolution. The simplicity and power of the XploRA PLUS is unmatched and with a broad range of options, the system provides the best platform for multi-sample and multi-user environments. Find out more at www.horiba.com/xplora Chemical Analysis & Imaging for Research & Industry Simply Better Raman XploRA PLUS

Upload: others

Post on 02-May-2022

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: XploRA PLUS - Gammadata

Powerful Technology

•Research grade microscope•SWIFT™ 10x faster Raman images• Integrated motorized optics/lasers•Higher sensitivity deep cooled CCD•Higher spectral resolution•Full confocality - 500 nm XY•Multi-laser options with OneClick operation•Expandable platform: AFM, macro sampling, EMCCD

The XploRA PLUS incorporates many unique and powerful functions in a reliable, high performance system design, ideally suited to the research and analytical lab. It is fully confocal, not compromising image quality or spatial or depth resolution. The simplicity and power of the XploRA PLUS is unmatched and with a broad range of options, the system provides the best platform for multi-sample and multi-user environments.

Find out more at www.horiba.com/xplora

Chemical Analysis & Imaging for Research& Industry

Simply Better Raman

XploRA PLUS

Page 2: XploRA PLUS - Gammadata

[email protected] www.horiba.com/scientific

This

doc

umen

t is

not

con

trac

tual

ly b

ind

ing

und

er a

ny c

ircum

stan

ces

- P

rinte

d in

Fra

nce

- ©

HO

RIB

A J

obin

Yvo

n 03

/201

4

USA: +1 732 494 8660 France: +33 (0)1 69 74 72 00 Germany: +49 (0)89 4623 17-0UK: +44 (0)20 8204 8142 Italy: +39 2 5760 3050 Japan: +81 (0)3 6206 4721China: +86 (0)21 6289 6060 Brazil: +55 (0)11 2923 5400 Other: +33 (0)1 69 74 72 00

XploRA PLUS Specifications

XploRA PLUS - Raman Base Unit

Laser options• Integrated up to 3 internally: 532 nm, 638 nm, 785 nm• Other wavelengths and high power options available on request• PC controlled with AutoSwitch option for Raman/white light selection

Spectral resolution • 1.4 cm-1 to 8 cm-1 depending upon grating, laser and CCD selection

Spectral range • 50 cm-1 to 4000 cm-1 depending upon grating, laser selection

Spectrograph • Imaging flat field spectrometer for use with larger CCD detectors• High throughput with 4 position grating turret

Confocal resolution • Fully confocal, adjustable confocal aperture, 500 nm XY resolution • Option for SWIFT™ 10x faster Raman imaging mode

Laser control • PC controlled ND filter module• Optional Raman polarizors

Detector

• OE. 1024 x 256 pixel TE deep- air cooled -60° C scientific CCD• USB control• No maintenance vacuum• 16 bit and up to 1.48 MHz readout speed

Optional detectors • 1024 x 256 BIDD TE air cooled scientific CCD • Various EMCCD detectors available on request

Microscope Options

Upright scientific microscope

• Includes standard 2 position illuminator with illumination by transmission/reflection• USB image camera• 10x and 100x objectives included

Epifluorescence and visualization

• Fluorescence imaging options (6 position illuminator)• High sensitivity camera and filter cubes • Polarized light accessories • DIC and dark field imaging

XY motorized stage

• Optional 70 x 50 mm • 0.1 µm step mapping stage with SWIFT™ imaging • Synchronous confocal Raman scanning• Optional 10 nm Piezo XY stage

CDRH Class (I) • Option for larger volume Class (I) safety enclosure for use in the open laboratory

Objectivessampling optics

• 50x LWD, 100x LWD options• Macro cuvette cell sampler • Fibre-optic probes • Optional autofocus

Heating cell• Optional heating/cooling cells for sample temperature control • DAC optional• Humidity and incubator stages optional

Validation

• Autocalibration/validation as standard• Methods and user level login compliant software options as standard• NIST traceable calibration standards• Optional standard PRO patented calibration objective

Software• OneClick operation as standard• LabSpec Spectroscopy Suite• Options: database, chemometric, imaging, ParticleFinder

Environment - RequirementsWeight • 35 kg - 77 lbs

Operating temperature • 15 - 28° C (optimal 22° C ± 1° C)

Voltage • 110/240 VAC, Mains supply

Dimensions (wxdxh) • 479 x 352 x 661 mm

Note: No water cooling or LN2 supply required

λ = (400 nm - 800 nm) P ≤ 150 mWVISIBLE AND/OR INVISIBLE LASER RADIATION

AVOID EXPOSURE TO BEAMCLASS 3B LASER PRODUCT