GAFCHROMIC XR Type RAn ideal tool to measure surface peak skin dose in Interventional radiation,
guided by fluoroscopy
Updated Jan’06
INTERNATIONAL SPECIALTY PRODUCTSINTERNATIONAL SPECIALTY PRODUCTS
1361 Alps Road Wayne NJ 07470∙ Tel: 973-628-40001361 Alps Road Wayne NJ 07470∙ Tel: 973-628-4000A BUSINESS UNIT OF ISP
What are the harmful effects from cumulative X-Ray exposure?
Short term: Dermal erythema, depilation, ulceration Long term: Stochastic effects including cancer inducement
What we know……
How to minimize the risks? Responsible Radiation Management
Monitor and document patients’ peak skin dose. In particular for:
Heavy patients Long Procedures Repeat Procedures
Strategize & refine fluoroscopy management
INTERNATIONAL SPECIALTY PRODUCTSINTERNATIONAL SPECIALTY PRODUCTS
1361 Alps Road Wayne NJ 07470∙ Tel: 973-628-40001361 Alps Road Wayne NJ 07470∙ Tel: 973-628-4000A BUSINESS UNIT OF ISP
Ways to Measure Dose Skin dose is determined by measuring the Skin dose is determined by measuring the darkening of the film using either:darkening of the film using either: Densitometer (preferably a reflection Densitometer (preferably a reflection densitometer) densitometer)
Comparator stripComparator strip Flatbed scanner – Epson’s 1640-XL or GT-15000Flatbed scanner – Epson’s 1640-XL or GT-15000
INTERNATIONAL SPECIALTY PRODUCTSINTERNATIONAL SPECIALTY PRODUCTS
1361 Alps Road Wayne NJ 07470∙ Tel: 973-628-40001361 Alps Road Wayne NJ 07470∙ Tel: 973-628-4000A BUSINESS UNIT OF ISP
How does GAFCHROMIC XR help?
Detail dose distribution Immediate visualization of patient exposure – magnitude and location L & R are
patient’s orientation
L
R
A picture worth a thousand words Raises physicians’ awareness Know where to treat a latent skin injury Define where to avoid exposure in future procedures
GAFCHROMIC XR Type R film - a simple tool for comprehensive monitoring of patient exposure and physician training. Comes in 14”x17” in size
INTERNATIONAL SPECIALTY PRODUCTSINTERNATIONAL SPECIALTY PRODUCTS
1361 Alps Road Wayne NJ 07470∙ Tel: 973-628-40001361 Alps Road Wayne NJ 07470∙ Tel: 973-628-4000A BUSINESS UNIT OF ISP
A look at the positioning of the GAFCHROMIC XR Type R film
FILM
INTERNATIONAL SPECIALTY PRODUCTSINTERNATIONAL SPECIALTY PRODUCTS
1361 Alps Road Wayne NJ 07470∙ Tel: 973-628-40001361 Alps Road Wayne NJ 07470∙ Tel: 973-628-4000A BUSINESS UNIT OF ISP
GAFCHROMIC XR-R Feature Large (14”x17”), stable and easy to handle sheetsLarge (14”x17”), stable and easy to handle sheets
Functions as a wide-area dosimeterFunctions as a wide-area dosimeter Ideal for measuring and mapping patient skin doseIdeal for measuring and mapping patient skin dose Use is transparent to the patient and physicianUse is transparent to the patient and physician
Film Film darkensdarkens in proportion to dose in proportion to dose Results easily interpreted by visual inspectionResults easily interpreted by visual inspection Easily measured with off-the-shelf Easily measured with off-the-shelf
densitometers/scannersdensitometers/scanners Absolutely no post-exposure processing requiredAbsolutely no post-exposure processing required Not light sensitiveNot light sensitive Energy independent from 60kVp to 120kVpEnergy independent from 60kVp to 120kVp Dose rate and dose fraction independentDose rate and dose fraction independent Can be cut into smaller sizesCan be cut into smaller sizes
INTERNATIONAL SPECIALTY PRODUCTSINTERNATIONAL SPECIALTY PRODUCTS
1361 Alps Road Wayne NJ 07470∙ Tel: 973-628-40001361 Alps Road Wayne NJ 07470∙ Tel: 973-628-4000A BUSINESS UNIT OF ISP
For more System Information…..
Please visit
www.gafchromic.comOr
Customer service @ 877-591-7884
and 973-628-3523
INTERNATIONAL SPECIALTY PRODUCTSINTERNATIONAL SPECIALTY PRODUCTS
1361 Alps Road Wayne NJ 07470∙ Tel: 973-628-40001361 Alps Road Wayne NJ 07470∙ Tel: 973-628-4000A BUSINESS UNIT OF ISP
GAFCHROMIC XR Type R Filmhas been Widely Used
Field trials and clinical users includeField trials and clinical users include J. O’Connell, Bureau of Environmental Radiation Protection, New J. O’Connell, Bureau of Environmental Radiation Protection, New
York State Department of Health – Cardiology Dosimetry Survey York State Department of Health – Cardiology Dosimetry Survey at 32 Interventional Cardiology Centers in New York State at 32 Interventional Cardiology Centers in New York State
Dr. B. Archer, Baylor College of Medicine, Houston, TXDr. B. Archer, Baylor College of Medicine, Houston, TX Dr. L. Wagner, UTH-Texas Medical Center, Houston, TX Dr. L. Wagner, UTH-Texas Medical Center, Houston, TX E. Giles, St. Luke’s Episcopal Hospital, Houston, TXE. Giles, St. Luke’s Episcopal Hospital, Houston, TX Dr. R Chu, University of Oklahoma, Oklahoma City, OKDr. R Chu, University of Oklahoma, Oklahoma City, OK Dr. G. Hegy, McGill University Health Center, Montreal, QCDr. G. Hegy, McGill University Health Center, Montreal, QC Dr. D. North, Rhode Island Hospital, Providence, RIDr. D. North, Rhode Island Hospital, Providence, RI Dr. P. Kuan, Univ. Hospital and Medical Center, Stony Brook, NYDr. P. Kuan, Univ. Hospital and Medical Center, Stony Brook, NY Dr. A. Meigooni, Univ. of Kentucky Medical Center, Lexington, Dr. A. Meigooni, Univ. of Kentucky Medical Center, Lexington,
KYKY J. Campbell, William Beaumont Hospital, Troy, MIJ. Campbell, William Beaumont Hospital, Troy, MI Dr. H. Nishitani, University of Takushima, JapanDr. H. Nishitani, University of Takushima, Japan Dr. R. Padovani, Santa Maria della Misericordia Hosp., Udine, Dr. R. Padovani, Santa Maria della Misericordia Hosp., Udine,
ItalyItaly Dr. E Vano, S. Carlos University Hospital, Madrid, SpainDr. E Vano, S. Carlos University Hospital, Madrid, Spain