yavar - work sample
TRANSCRIPT
-
Balboa Research Park Complex
-
S Scale 1/16=1-00
Concerete Pads Concept
1/64" = 1'-0"1Section 1 1/64" = 1'-0"1Section 1
-
1/64" = 1'-0"2Section 3 1/64" = 1'-0"2Section 3
Diamond Gliding Port
Glider Storage 1350 sq.ft
Lecture 400 sq.ft
Display 600 sq.ft
Break Room 150 sq.ft
Assistant Manager 100 sq.ft
Manager Office 200 sq.ft
Kitchen 200 sq.ft
Indoor Dining 500 sq.ft
Serving Counter 100 sq.ft
Dry/Cold Storage 100 sq.ftCheck-In/ Store 900 sq.ft1
2
3
4
5
6
7
8
9
10
11
12 Bathrooms 600 sq.ft
322
338
322
320
310
320
330
31 8
1
Section C-C
+ 330 ft
+ 330 ft
+ 330 ft
+ 330 ft + 330 ft
+ 330 ft
+ 330 ft
+ 330 ft
+ 330 ft
+ 330 ft
Section C-C
23
4
5
6
7
8
109
11
12
Section A-A
Sec
tion
A-ASection B-B
Section B-B
6 3D View 9
-
Squares of Labs
-
Framing the Space
REF.REF.
REF.
2 3 5
A
D
F
1 4
E
C
-
6 3D View 9
Coccon Kindergarten
-
Surface of Art Gallery
-
Renders
-
Architecture Professional Works
Hilltop ProjectRemodel & Permit
971 Hilltop Dr.Chula Vista, CA 91910
12/06/2016
Jones ResidenceRemodel & Permit
3736 Budd St.San Diego, CA 92111
06/17/2016
Corte Maria ProjectRemodel & Permit170 corte maria Ave
Chula Vista, CA 9191011/09/2016
Ashton TownhomesDraing
10390 Ashton Ave.Los Angles, CA 90025
08/01/2013
Tenenbaum ResidenceDraing
23973 Long Valley RoadHidden Hills, CA 91302
08/01/2012
Richards ResidenceDraing
23726 Long Valley Rd.Hidden Hills, CA 91302
08/20/2012
Lionelli ResidenceDraing
24221 Long Valley Rd.Hidden Hills, CA 91302
07/06/2012
Awenta ProjectDraing
11425 Awenta CT.Inidian Spr, CA 91311
06/18/2012
Daneshbodi ResidenceRemodel & Permit
1340 Knoxville St.San Diego, CA 92110
05/04/2016
Schotz ResidenceDraing
5400 JED Smith Rd.Hidden Hills, CA 91302
07/23/2012
RSRA PropertiesDraing
30300 Agoura RdAAgoura hills, CA 91301
11/16/2012
Kravitz ResidenceDraing
5546 JED Smith Rd.Hidden Hills, CA 91302
07/05/2012
Tenenbaum Residence
-
MEP Professional Works
Rumex LLCDraing
717 N McCadden PL.Los Angeles, CA 90038
07/04/13
Hangar HomesDraing
12107 Ocean Park Blvd.Los Angeles, CA 90064
11/30/13
Lockwood LLCDraing
4255 Lockwood Ave.Los Angeles, CA 90029
08/13/13
New HampshireDraing
1759 New Hampshire AveLos Angeles, CA 90027
2/12/14
Bakman ApartmentsDraing
5044 Bakman AveLos Angeles, CA 91601
01/30/14
Rumex CO.Draing
Los Angeles, CA 9003806/12/13
OCEAN PARK BLVD. HANGARHOMES12107 Ocean Park Blvd.Los Angeles, CA 90064Owner: Matthew Jacobs andLani Sung, Tenants in Common,or assignees
KEY PLAN
OCEAN PARK BLVD.
AB
CD
All ideas, designs, arrangements and plansindicated or represented by this drawingare owned by and the property ofModative, Inc. and are solely for use on thespecified project and shall not be used onother projects, or for additions to thisproject, or for the completion of this projectby others without the prior written consentof and appropriate compensation toModative, Inc. No part thereof shall bereproduced, copied, adapted, published,sold, distributed to others or otherwise usedwithout the prior written consent of andappropriate compensation to Modative,Inc. Copyright
PROJECT NO 12005
DATESCALE
A8.2
PARCEL C - LIGHTING/REFLECTED CEILINGPLANS
11/30/13AS SHOWN
25% CD
s
NOT FO
R CON
STRUCT
ION
W WW
GARAGE14
LIVING11
KITCHEN12
CA
9.3.6
9.3.6
9.3.6
9.1.4
9.1.4
+7'-0"
UCFL
V
UCFL
+12'-10 7/8"
M
LEV
ELA
BOV
E
+7'-0"
+7'-10 7/8"
M
D
+8'-0
"
M BATH22
W.I.C.23
MASTER BEDROOM21
DECK24
W
CA
SD
9.3.6
9.3.6
+8'-10 7/8"
OPEN TOSKY
SEE UPPER SECONDLEVEL RCP
+7'-0"
+8'-10 7/8"
LEV
ELBE
LOW LE
VEL
ABO
VE
V
D
9.3.6
BATH27
LAUNDRY26
WALK-IN CLOSET29
BEDROOM28
OFFICE25
WCA
SD
9.3.6
9.3.6
9.3.69.3.6
9.3.6
SEE LOWER SECONDLEVEL PLAN
+8'-0"
SLOPED
+8'-0"
LEV
ELA
BOV
E
LEV
ELBE
LOW
+7'-9 1/8"
V
SLOPED
SLOPED
+8'-0"
DECK31
9.3.6
LEV
ELBE
LOW
SEE UPPER SECONDLEVEL RCP
OPEN TOSKY
SLOPED
W
W
W
W
9.1.4
9.3.6
SLOPED
SLOPED
AF
W
J
J
DL
V
M
DR
CA
CM
SD
REFLECTED CEILING PLAN NOTES
A. SEE ELECTRICAL NOTES.
B. FOR LIGHTING LOCATIONS, DIMENSIONS,SWITCHING AND WIRING, SEE RCPs.
C. ALL SOFFITS AND CEILINGS ARE DIMENSIONEDTO FINISH FACE UNLESS OTHERWISE NOTED.
D. CEILING HEIGHT CALLOUTS ARE APPROXIMATE.VERIFY HEIGHTS OF CEILING CALLOUTS IN FIELDBASED ON ACTUAL FRAMING.
E. SMOKE ALARMS - SHALL RECEIVE THIERPRIMARY POWER SOURCE FROM THE BUILDINGWIRING AND SHALL BE EQUIPPED WITHBATTERY BACKUP AND LOW BATTERY SIGNAL.WHERE MORE THAN ONE SMOKE ALARM ISREQUIRED TO BE INSTALLED, THEY SHALL BEINTERCONNECTED IS SUCH A MANNER SOTHAT THE ACTIVATION OF ONE ALARM WILLACTIVATE ALL OF THE ALARMS. SMOKEALARMS SHALL BE INSTALLED AND MAINTAINEDAT ALL OF THE FOLLOWING LOCATIONS: INEACH ROOM USED FOR SLEEPING PURPOSES,ON THE CEILING OR WALL OUTSIDE IMMEDIATEVICINITY OF SLEEPING ROOM, IN EACH STORY,BASEMENT OR SPLIT LEVEL WITHIN A DWELLINGUNIT, AND IN ENCLOSED COMMONSTAIRWELLS OF TWO OR MORE DWELLINGUNITS. (R314)
CEILING HEIGHT A.F.F.
GYPSUM BOARD CEILING
GYPSUM BOARD SOFFIT
WOOD T & G CEILING
METAL PANEL CEILING
SHIPLAP CEMENT BOARD CEILING
REFLECTED CEILNG PLAN SYMBOLS
+9'-0"
ELECTRICAL NOTES
A. DOCUMENTS - THE LIGHTING PLAN IS NOTINTENDED TO REPRESENT A COMPLETE SET OFELECTRICAL DRAWINGS. EXCEPT WHEREINDICATED OTHERWISE, THE LOCATION ANDSELECTION OF ANY ELECTRICALREQUIREMENTS NOT DIRECTLY RELATED TO THELIGHTING SHALL BE BY OTHERS.
B. ENGINEERING - ELECTRICAL CONTRACTOR TOPROVIDE ELECTRICAL WORK DESIGN BUILD.ALL WORK TO BE PERFORMED INCOMPLIANCE WITH ALL LAWS ANDAPPLICABLE CODES.
WALL MOUNTED FIXTURE
SURFACE MOUNTED FIXTURE
RECESSED (4 PIN) FLUORESCENTDOWNLIGHT
RECESSED LED DOWNLIGHT
WATERPROOF (4 PIN)FLUORESCENT RECESSEDDOWNLIGHT
EXHAUST FAN W/ HUMIDISTATCONTROL, ENERGY STARCOMPLIANT, DUCTED TO OUTSIDE
EXHAUST FAN/LIGHT COMBO W/HUMIDISTAT CONTROL, ENERGYSTAR COMPLIANT, DUCTED TOOUTSIDE
SURFACE MOUNTED J BOX
WALL MONTED J BOX
SURFACE MOUNTED FLUORESCENTTUBE FIXTURE
FLUORESCENT TUBE FIXTURE UNDERCABINET
LIGHTING SYMBOLS
UCFL
CEILNG FAN(FOR WIRING, OWNER SUPPLIEDFIXTURE. PROVIDE CEILING FANRATED J BOX.)
SWITCH(2WAY, 3 WAY, & 4 WAY PERPLANS)
DIMMER SWITCH
MOTION SENSOR SWITCH
VACANCY SENSOR SWITCH
DOOR CONTROLLED SWITCH
SMOKE ALARM W/ BATTERYBACKUP, HARDWIRED,INTERCONNECTED
CARBON MONOXIDE ALARM W/BATTERY BACKUP, HARDWIRED,INTERCONNECTED
COMBINATION SMOKE ANDCARBON MONOXIDE ALARM W/BATTERY BACKUP, HARDWIRED,INTERCONNECTED
NORTH
FIRST LEVEL LIGHTING / R.C.P. 11/4" = 1'-0"
LOWER SECOND LEVEL LIGHTING / R.C.P. 21/4" = 1'-0"
UPPER SECOND LEVEL LIGHTING / R.C.P. 31/4" = 1'-0"
DECK LEVEL LIGHTING / R.C.P. 41/4" = 1'-0"
C