y.cheetah experience brilliance in any job!
DESCRIPTION
Y.Cheetah Experience brilliance in any job!. International Sales Meeting 2009 Hamburg Holger Behnsen. More than Y.Cougar‘s versatility Higher than Y.Tiger‘s flexibility Highest quality image chain as standard Easier to operate but not as precise as Y.Fox …now goes also NDT!. - PowerPoint PPT PresentationTRANSCRIPT
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
1
Y.CheetahExperience brilliance in any job!
International Sales Meeting 2009 Hamburg
Holger Behnsen
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
2
Y.CheetahNew solution in the Feinfocus family
More than Y.Cougar‘s versatility
Higher than Y.Tiger‘s flexibility
Highest quality image chain as standard
Easier to operate but not as precise as Y.Fox
…now goes also NDT!
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
3
Unique Features: Secure your findings
with brilliant images: Proprietary Feinfocus
Technology – µ-focus & multi-focus (MFT)– TXI, HP-Target, other targets
High-speed digital flat panel detector as standard
Unmatched manipulation concept: – Twin instead of single
magnification axis– Multimodal operation of
magnification axis– Image stabilization through air
bearing …
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
4
ApplicationsElectronics
Typically used in electronics and related industries
2D & 3D inspection
Modular concept allow for reconfiguration for NDT applications
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
5
Microfocus Tube TechnologyGeometric unsharpness
Importance of a small focal spot
size
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
6
Feinfocus Tube Technology Open tube design Microfocus or Multifocus (MFT)
design Optional MFT offering 3 modes:
– Nanofocus– Microfocus– High-Power
Unlimited life-time TXI – True X-ray Intensity control 64W tube power Various options Detail detectability down to <500
nm
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
7
Detector Technology Best image quality in
the market Flat panels detector
technology as standard Distortion-free Real time imaging 16 bit image
processing Various modes such as:
– High quality– Medium quality– Real-time
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
8
Advanced ManipulationZoom+ - Synchronized motion for tube & detector
Constant X-ray intensity No alteration to tube
settings No detector re-calibration Constant contrast Continuously brilliant
images throughout the inspection
Faster inspection Superior image quality Effortless operationClick image for animation
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
9
Advanced ManipulationPowerDrive – Driving for power and speed
Increasing intensity Optimizing for signal-to-
noise Faster image capture Even quicker µCT scans All while magnification
remains constant 1-click to PowerDrive
mode Simple joystick operation Power boost factor of 33x Click image for animation
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
10
1-click Solutions 1-click to first image 1-click „Click & Center“ 1-click „Frame & Zoom“ 1-click „Steer & Fly“ 1-click access to library
of automated inspection routines
1-click access with to µCT workspace with execution (option)
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
11
Y.CheetahWhat makes it suitable for NDT market?
Modular design– Exchangeable sample
tabels for easy customization
Multifocus Tube technology with High Power operating mode
High Power target for best resolution at high power
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
12
Y.CheetahModular design allows for easy customization
Various sample tabels
Standard up to 5 kg
Sample table for NDT may carry up to 10 kg
Different fixtures allow for adaption to customer needs
Standardsample table
Standardsample table
CT-sample tabel
Rotational sample tabel
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
13
ApplicationsNDT – Al casting
Al casting for automotive industry
Small part for front lights
Structure and voids clearly visible
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
14
ApplicationsNDT – Casted fitting
Picture of fitting
2D X-ray picture
Cross section of hexagonincl. Measurements
Cross section lengthwise incl. measurements
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
15
ApplicationsNDT – Turbine blades
2D picture of turbine blade
Microfocus X-ray using High-Power-Target
130kV, 7µA
All details visible
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
16
ApplicationsNDT – Turbine blades
Detailed view of previous turbine blade
130kV, 7µA
Defective area clearly visible
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
17
ApplicationsNDT – Turbine blades
Detailed view of previous turbine blade
130kV, 7µA
Defective area clearly visible
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
18
1-click Series Inspection Easy and fast loading
of sample trays 1-click to apply one
inspection routine at numerous cells in a grid
Full view of inspection are in overview image
Access to a databank of inspection routines
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
19
Automated Inspection RoutinesEasy teach-in via 6-step recipe
1. Load sample and activate X-ray2. Position sample and adjust settings3. Compose image process (optionally)4. Select "Set & Save Image"5. Go back to step 2 for further analysis6. Select “Finish” in Teach-In menu
Training automated inspections
Access to fully
flexible Visual
Basic …And to
library of inspections
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
20
µCT – Computed TomographyPrincipal
2D projections
ima, jpg, tif …
Focus
Object
DetectorFOD
FDD
α
x
yz
3D slices
3D view
Filtered back-projection
µ, α,no.
Volume Data
Voxel
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
21
µCT – Computed TomographyExample car key
µCT volume scan µCT Region of Interest (ROI) scan Higher magnification, better
resolution
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
22
Y.CheetahExperience Brilliance in Any Job!
Benefits
Secure your findings with brilliant images
Any task in your daily routine solved quickly
1-click solutions
BI 2
9.08
.03
YXLON. The reason why
Y.Ch
eeta
h – I
SM20
09 H
olge
r Be
hnse
n
23
Y.CheetahExperience brilliance in any job!
Sharp.Fast.Versatile