your partner for gas monitoring solutions ... systems.pdf · sm200 particulate monitor. ... your...

42
Your Partner for Gas Monitoring Solutions www.opsis.se OPSIS Gas Monitoring Systems

Upload: lamngoc

Post on 19-Apr-2018

220 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

OPSIS Gas Monitoring Systems

Page 2: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

OPSIS ABA Swedish Environmental Technology Company, providing:

• Air quality monitoring systems using open-path technology

• Air Quality Management Software Tools

• Continuous Emission Monitoring Systems

Page 3: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

• Founded in 1985

• Located in Furulund, south of Sweden

• 55 employees

• Represented worldwide

OPSIS AB

Page 4: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Our Skilled Distributors• Attend Opsis technical

training courses at least oncea year to keep up the highknowledge about oursystems.

• Knows the installationprocedures.

• Offer service andmaintenance.

• Are well educated in bothhardware and software.

• Has direct contact with therespective marketing managerin Sweden.

Page 5: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

CEM AQMData management and modelling

Major Application Areas

Page 6: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

AQM Applications• Urban trend monitoring (“roof top”)

• Fence-line monitoring of fugitive emissions

• Street-level monitoring

• Airport monitoring

• Background monitoring

Page 7: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

OPSIS Products

Page 8: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Fibre Optic Cable

Emitter Receiver

Analyser

NO2

O3

SO2

DifferentialOpticalAbsorptionSpectroscopy

OPSIS DOAS Open Path

BTX

Page 9: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

DOAS Analyser

Page 10: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Emitter and Receiver Set

Page 11: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Criteria pollutantsSO2

NO2

NOO3

Aromatic HCBenzeneTolueneStyrene

EthylbenzeneXylenesCresols

TrimethylbenzenesMonochlorbenzene

Dichlorbenzene

Smelling compoundsNH3

CS2

TrimethylamineFormaldehydeAcetaldehyde

Phenol

Compounds Measured by Opsis DOAS

Page 12: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Mercury (Hg0)

Phosgene (COCl2 )

Chlorine (Cl2)

Sulphur Trioxide (SO3)

Hydrogene Fluoride (HF)

Hydrogen Chloride (HCl)

Hydrogene Cyanide (HCN )

Methylisocyanate (MIC)

Special Opsis DOAS Compounds

Page 13: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

OPSIS DOAS Benefits• No sampling system, pumps, filters or scrubbers

• Low maintenance and operational costs

• Multiple gas capability

• Multiple path capability

• Superior area coverage

• High performance

• Integrated signal handling system

• Long life time

• Internationally approved

Page 14: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

TÜV, Germany• SO2• NO2• O3

• Benzene• PM10

Gosstandard, Russia• SO2

• NO• NO2

• O3

• H2S• NH3

• CO• Cl2

• HCl• Styrene• Benzene• Toluene• Phenol• Formaldehyde• HF• CH4

C.N.R., Italy• Benzene• SO2• NO2• O3• PM10

U.S. EPAThe Opsis system is designated equivalent to 40 CFR.

• SO2, NO2, O3

MCERTS, UK• SO2• NO2• O3

• Benzene• PM10 (pending)

Approvals AQM

Page 15: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

OPSIS Laser Diode Gas Analyser

Page 16: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

LD500 Laser Diode Gas Analyser

Page 17: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

• Operates with a minimum of maintenance

• Fast response time (~ 1 sec)

• Multiple paths (1-8)

• Multiple gases (NH3, HF, HCl, O2, CO2, H2S, CH4, H2O…)

• Long fibre cable lengths (< 1 km)

• Low detection limits

• Semiconductor laser = reliable, long lifetime

• Automatic optical alignment

• Calibration equipment

• I/O signals with IO256 and IOMan modules

• Built-in serial communication and modem

Features of LD500

Page 18: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

SM200 Particulate Monitor

Page 19: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

• Automatic particulate monitor and sampler

• TSP, PM10, PM2.5 and PM1.0

• Tested and approved within the European Union

• Samples on 47 mm filters for further lab analysis(such as led, cadmium etc.)

• Several hundreds of installations

Features of SM200

Page 20: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Data acquisition and validation

Emission calculations, presentation and reporting

Advanced analysis of data

Dynamic emission database

GIS and dispersion modelling

Air quality forecasts

Export to Intranet/Internet

Software Products

Page 21: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

• Monitoring the air quality for compliancewith directives/guidelines

• Monitoring fugitive industrial emissions

• Providing a fast and sensitive gas alarmsystem

Three functions in one package:

The Fence-line Monitoring Concept

Page 22: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Configuration Example

Page 23: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

• Provides useful information on general air quality, but also on specificindustrial fugitive emissions.

• Provides useful information for air quality management and ISO14000 compliance.

• Will give extensive information on export and import of gaseouscompunds to and from neighbouring areas.

• Provides alarms in case of gas leaks or accidential releases.

• Detection and actions against gas leaks and fugitive emissions costsavings.

Features of Fence-line Monitoring

Page 24: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Fence-line monitoringusing 3 × 3 DOAS paths

Case Study – Biferno, Italy

Page 25: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

• The problem: Several industries in a valley creating high pollutionlevels.

• The objectives: Finding efficient monitoring techniques that can beused for monitoring multiple paths and a large number of gascompounds, and a software tool for managing obtained data.

• The solution: Advanced monitoring stations in a fence-lineconfiguration using DOAS open-path monitors in combination withEnviMan software.

Why Choosing Opsis?

Page 26: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Type of industries and fugitive Emissions:

• Automotive – Formaldehyde, HC

• Sugar factory and refinery – NOx, SO2, H2S

• Various chemical industries – Phenols, CS2, NH3

• Food industry – Various HC

Industries and Emissions

Page 27: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

DOAS:SO2, NO2, NO, O3, NH3, Benzene, Toluene, P-xylene,Styrene, CS2, Formaldehyde, Acetaldehyde, Phenol, HCl, HF,Hg0, O-, M- and P-Cresol

Meteorological:Wind speed, wind direction, temperature, pressure, humidity andglobal radiation

Others:CO, GC ( PAH), PM10

Parameters Monitored

Page 28: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

The Opsis open-path stations are using motorized receivers (RE130)to monitor 3 light paths at each station.

The emitters used in this application are of the model EM150,designed for a maximum path length of 2000 m.

The AR520 analysers can handle both UV and IR absorption.

Monitoring Equipment

Page 29: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Air-conditioned shelter

Metereological mast with sensors

Motorized receiver (operating3 monitoring paths/emitters)

Station Design

Page 30: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

View of the Emitter

Page 31: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Station with Shelter and RE130 Receiver

Page 32: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

The major sources of SO2 could be identified at ”WITCO”using Breuer diagram with SO2 and wind information

Page 33: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

The major sources of Toluene could be identified at ”STS”using Breuer diagram with toluene and wind information

Page 34: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Modern technologies such as the open-path DOAS monitoring systemcan provide important information on the pollution situation in andaround industrial estates, such as:

• How residential areas are affected by specific industrial emissions

• Import and export of pollution in the area

• Locations of the most significant sources of pollution

• Concentrations of gases to be compared with guidelines and healthlimits

• A database for future planning and decision-making

Conclusions

Page 35: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Runway

Gateway

Control tower

AnalyserReceiverEmitter

Gases monitoredBenzene, toluene, 1,2,4-trimethylbenzene,1,3,5-trimethylbenzene, NO, NO2, SO2

200 m

Cologne, Germany

Copenhagen, Denmark

Düsseldorf, Germany

Greece

Toronto, Canada

Zürich, Switzerland

OPSIS Monitoring at Airports

Page 36: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Receiver Analyser

Analyser

Emitter1) 5 m elevation

2) 15 m elevation

Receiver

Emitter

20 m

20 m

Location:China

Parameter:Methylisocyanate

Chemical Plant

Page 37: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

800 mPlant Area

Village

CS MonitoringLocation: Valkeakoski, Finland

Parameter: CS

Page 38: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

1300 m

300 m

Plant Area

800 m

Fertilizer and Chemical PlantLocation: Norway

Parameters: Hg, Cl2, NH3, NO, O2, NO2, SO2

Page 39: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Receiver Analyser

Emitter

Receiver

Emitter

300 m

300 m

MX Refinery 1Location: Belgium

Parameter: Benzene

Page 40: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

800 m

2

Plant Area

Refinery 2Location:Saudi Arabia

Parameters:NO, NO2, BTX, HF, HCl, CS,Phenol, Formaldehyde

Page 41: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

Receiver

Analyser

Emitter

1000 m

Plant Area

Waste IncineratorLocation: Florida, the U.S.

Parameter: Hg

Page 42: Your Partner for Gas Monitoring Solutions ... Systems.pdf · SM200 Particulate Monitor. ... Your Partner for Gas Monitoring Solutions Modern technologies such as the open-path DOAS

Your Partner for Gas Monitoring Solutions

www.opsis.se

WWW.OPSIS.SE >>