zbamb5278a pro eas about the product label deactivator coils

9
ZBAMB5278A PRO EAS LABEL DEACTIVATOR COILS 8200-0747-04, REV. F INSTALLATION GUIDE 1 of 9 *8200-0747-04* ZBAMB5278A Pro EAS Label Deactivator Coils Installation Guide TYPE: AMB-5278 If you need assistance… For product bulletins, the most recent updates to this document, or to speak to a technical support specialist, visit www.sensormatic.com and select the Support link in the menu bar. About the Product European Regulatory Restriction: None. Intended Use: Only install this device as described in this guide. See page 2 for additional WARNINGS and CAUTIONS. Product Description The ZBAMB5278A Pro deactivator coils connect to a ZBSMPROE ScanMax ® Pro controller, ZBAMB9010, or ZBAMB9010-IPS controller to detect and deactivate UltraStrip ® low energy security labels. These coils are installed inside an NCR 78OFX RealScan Bi-optic Scanner/Scale. Note: Installation and service of the coils will be performed by the NCR service group for Walmart. For other accounts the customer may use ADT or a third party to install the coils. © 2017 Sensormatic Electronics, LLC

Upload: others

Post on 18-Dec-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ZBAMB5278A Pro EAS About the Product Label Deactivator Coils

ZBAMB5278A PRO EAS LABEL DEACTIVATOR COILS 8200-0747-04, REV. F

INSTALLATION GUIDE 1 of 9 *8200-0747-04*

ZBAMB5278A Pro EAS Label Deactivator Coils Installation Guide

TYPE: AMB-5278

If you need assistance…

For product bulletins, the most recent updates to this document, or to speak to a technical support specialist, visit www.sensormatic.com and select the Support link in the menu bar.

About the Product

European Regulatory Restriction: None.

Intended Use: Only install this device as described in this guide.

See page 2 for additional

WARNINGS and CAUTIONS.

Product Description

The ZBAMB5278A Pro deactivator coils connect to a ZBSMPROE ScanMax® Pro controller, ZBAMB9010, or ZBAMB9010-IPS controller to detect and deactivate UltraStrip® low energy security labels. These coils are installed inside an NCR 78OFX RealScan™ Bi-optic Scanner/Scale.

Note: Installation and service of the coils will be performed by the NCR service group for Walmart. For other accounts the customer may use ADT or a third party to install the coils.

© 2017 Sensormatic Electronics, LLC

Page 2: ZBAMB5278A Pro EAS About the Product Label Deactivator Coils

ZBAMB5278A PRO EAS LABEL DEACTIVATOR COILS 8200-0747-04, REV. F

INSTALLATION GUIDE 2 of 9 *8200-0747-04*

PRECAUTIONS

Please read the following precautions for:

Safety

Cleaning

Device interaction

Installation.

SAFETY

WARNING!

Hazardous areas. DO NOT install this product in areas where highly combustible or explosive products are stored or used.

Power considerations. DO NOT plug or unplug any cable with power on.

Altitude limitation. This product is evaluated for use at altitudes up to 3200m (10,500ft).

WARNING— RISK OF ELECTRIC SHOCK!

No user-serviceable parts. DO NOT attempt to open this product.

Cable routing. Route the deactivator coil cable away from mechanisms whose operation may pinch or otherwise damage it. Failure to do so may damage equipment or injure people nearby. Also keep the cable from running parallel to cables of POS equipment.

Cleaning

Wipe the housing with a soft cloth moistened (not soaked) with mild detergent. Then wipe off excess.

Keep spills from entering the housing.

DO NOT USE:

Spray cleaners.

Ammonia- or chlorine-based cleaning solutions; they may damage the housing or corrode internal parts.

Abrasives, solvents, or flammable liquids.

Device Interaction

To avoid device interaction:

Keep the deactivator coils:

– At least 30.5cm (12in) from POS devices such as credit card readers, pin pads, keyboards, printers, and remote displays. If this is not possible, contact Sensormatic Technical Support for guidance.

– As far as possible from devices that may interact with the deactivator’s detection field such as computer screens, TVs, switching power supplies, and neon displays.

DO NOT place detached hard tags within 30.5cm (12in) of the deactivator coils.

Installation

Cable reach. Make sure that the coil EEPROM

cable can reach the controller.

Scanner scale. Do not allow the coil EEPROM

cable to rest or place pressure on the weigh scale posts in the scanner; otherwise, the weights and measures calibration will be voided.

Page 3: ZBAMB5278A Pro EAS About the Product Label Deactivator Coils

ZBAMB5278A PRO EAS LABEL DEACTIVATOR COILS 8200-0747-04, REV. F

INSTALLATION GUIDE 3 of 9 *8200-0747-04*

Installation

Parts Required

ZBSMPROE ScanMax Pro, ZBAMB9010, or ZBAMB9010-IPS controller

ZBAMB5278A vert./horiz. deactivator coils

Install Kit 0352-0640-01:

Item Qty Part Number

Cable, Interlock, AMB-5278 1 0652-0432-01

Connector, 4-Pin, Modular 1 2109-0317-01

Install Kit 0352-0337-01:

Item Qty Part Number

Extension Cable, AMB 5278 1 0652-0356-01

Grommet, edge, .052T 1 3200-0007-06

Mount, cable tie, adhesive 4 6009-0003

Cable tie, 5.5in LG x .16in WD 4 6009-0001

Prep pad, alcohol 2 1600-0033

1. Remove the scanner’s top plate and set it aside.

2. Remove the debris guard screws (one Phillips-head screw from each corner). Set the screws aside.

3. Remove the debris guard and set it aside.

4. Place fingers where shown on both sides of the bezel and pull the bezel away from the tower.

Page 4: ZBAMB5278A Pro EAS About the Product Label Deactivator Coils

ZBAMB5278A PRO EAS LABEL DEACTIVATOR COILS 8200-0747-04, REV. F

INSTALLATION GUIDE 4 of 9 *8200-0747-04*

5. Lift the bezel up and set it aside.

6. Route the antenna cable through the opening on the front of the base casting until it emerges out the underside of the scanner.

7. Position the upper antenna coil along the top

edge of the vertical window.

8. Lay the lower antenna coil down around the horizontal window (the coil must lay flat).

9. Make sure the cable wires lay flat and are not crisscrossed. Then insert the cable strain relief into the hole and press to snap it in place.

10. Reseat the debris guard and insert the four screws set aside in step 2.

Page 5: ZBAMB5278A Pro EAS About the Product Label Deactivator Coils

ZBAMB5278A PRO EAS LABEL DEACTIVATOR COILS 8200-0747-04, REV. F

INSTALLATION GUIDE 5 of 9 *8200-0747-04*

11. Snap the bezel back in place.

12. Reattach the top plate.

13. Connect one end of the extension cable 0652-0356-01 to the coil pigtail cable and its other end to the ANTENNA port of the controller.

Note: This cable must remain with the check stand when servicing the scanner or deactivator controller. This cable maintains system settings for the lane in which it is installed.

14. Connect the RJ-11 connector of the interlock cable marked “Connect to Scanner AUX 2” into Auxiliary Port 2 of the scanner, as shown below.

15. For ScanMax Pro controllers only: Cut off the existing 8-pin modular connector from the end of the interlock cable marked “Connect to Sensormatic” and replace it with the 4-pin version supplied. Refer to the wiring diagram below.

Auxiliary Port 2

Wires align with notch in

rear of debris guard.

Page 6: ZBAMB5278A Pro EAS About the Product Label Deactivator Coils

ZBAMB5278A PRO EAS LABEL DEACTIVATOR COILS 8200-0747-04, REV. F

INSTALLATION GUIDE 6 of 9 *8200-0747-04*

16. Carefully place the scanner rear first into the checkstand, taking care to guide the coil cable through the openings and to avoid pinching cables.

To connect to the controller, see either:

ZBSMPROE Connection, page 6.

ZBAMB9010 Connection, page 7.

ZBAMB9010-IPS Connection, page 8.

Spare Parts

A complete parts list is available online at: http://www.sensormatic.com/support/techsupport/. Login, then click the Part Information link on the Tech Support home page.

Part Number / Product Code Description

9U

*

FR

U**

0352-0337-01 AMB-5278 Install Kit No Yes

ZBSMPROE Controller Yes No

ZBAMB9010 Controller Yes No

ZBAMB9010-IPS Controller Yes No

* Reparable unit

** Field replaceable unit.

ZBSMPROE ScanMax Pro Connection

CAUTION: To avoid damaging the controller:

Perform the next three steps in order. DO NOT reverse the steps.

DO NOT plug or unplug any cable with power on.

1. Connect the EEPROM cable to the ANTENNA port of the controller.

2. Plug the interlock cable into the POS port of the controller (this is the modified 4-pin to 8-pin cable).

3. If used, plug the ZPSTP-RA Remote Alarm Module cable into the REMOTE port of the controller.

1

1

8 Pin

To ScanMax Pro To Scanner

4 Pin

0652-0432-01

Modified Cable GND

RS232 RX

RS232 TX

8

3

4

5

1

4

1

3

2

GND (RED)

RS232 TX (GRN) RS232 RX (YEL)

Page 7: ZBAMB5278A Pro EAS About the Product Label Deactivator Coils

ZBAMB5278A PRO EAS LABEL DEACTIVATOR COILS 8200-0747-04, REV. F

INSTALLATION GUIDE 7 of 9 *8200-0747-04*

4. Plug the AC power cord into the controller and its other end into an unswitched AC outlet having less than 0.5Vac between neutral and ground.

Note: The STATUS LED should be solid green. While the controller auto-synchronizes, this LED may briefly flash amber. Auto-sync can take up to ten seconds.

If the STATUS LED is solid red—STOP. Return the controller to an authorized repair center.

Leave the coil EEPROM cable in place if removing the controller for service. The EEPROM maintains system settings for the pad or coil location and will automatically update the new controller.

5. To setup the deactivator coils and verify their proper deactivation, see ZBAMB5278A Pro EAS Label Deactivator Coils Setup Guide 8200-0054-41.

For more information about the controller, see ZBSMPROE EAS Label Deactivator Controller Installation Guide 8200-0054-01.

ZBAMB9010 Connection

Note: If connecting to a ZBAMB9010-IPS, see page 8.

CAUTION: To avoid damaging the controller:

Perform the next three steps in order. DO NOT reverse the steps.

DO NOT plug or unplug any cable with power on.

1. Connect deactivator coil EEPROM cable 0652-0570-01 to the cable port of the controller.

2. Plug the end of interlock cable 0652-0432-01 marked “Connect to Sensormatic” into the scanner port of the controller (this is the 8-pin to 8-pin cable; discard the 4-pin connector in the kit).

Page 8: ZBAMB5278A Pro EAS About the Product Label Deactivator Coils

ZBAMB5278A PRO EAS LABEL DEACTIVATOR COILS 8200-0747-04, REV. F

INSTALLATION GUIDE 8 of 9 *8200-0747-04*

3. If used, plug the ZPSTP-RA Remote Alarm Module cable into the REMOTE port of the controller.

4. Plug the cable from the power supply into the power port of the ZBAMB9010 controller.

5. Plug the AC power cord into the power supply and its other end into an unswitched AC outlet having less than 0.5Vac between neutral and ground.

Note: The Status LED should be solid green. While the controller auto-synchronizes, the Status LED may briefly flash amber. Auto-sync can take up to ten seconds.

If the STATUS LED is solid red—STOP— return the controller to an authorized repair center.

Leave the coil EEPROM cable in place if removing the controller for service. The EEPROM maintains system settings for the coil location and will automatically update the new controller.

6. To verify proper deactivation of the deactivator coil, see ZBAMB5278A Pro EAS Label Deactivator Coils Setup Guide 8200-0054-41.

For more information about the controller, see ZBAMB9010 EAS Label Deactivator Controller Installation Guide 8200-0747-01.

ZBAMB9010-IPS Connection

CAUTION: To avoid damaging the controller:

Perform the next three steps in order. DO NOT reverse the steps.

DO NOT plug or unplug any cable with power on.

1. Connect deactivator coil EEPROM cable 0652-0570-01 to the cable port of the controller.

2. Plug the end of interlock cable 0652-0432-01 marked “Connect to Sensormatic” into the scanner port of the controller (this is the 8-pin to 8-pin cable; discard the 4-pin connector in the kit).

Page 9: ZBAMB5278A Pro EAS About the Product Label Deactivator Coils

ZBAMB5278A PRO EAS LABEL DEACTIVATOR COILS 8200-0747-04, REV. F

INSTALLATION GUIDE 9 of 9 *8200-0747-04*

3. If used, plug the ZPSTP-RA Remote Alarm Module cable into the REMOTE port of the controller.

4. Plug the AC power cord into the controller and its other end into an unswitched AC outlet having less than 0.5Vac between neutral and ground. Secure the power cord to the controller using a cable tie.

Note: The Status LED should be solid green. While the controller auto-synchronizes, this LED may briefly flash amber. Auto-sync can take up to ten seconds.

CAUTION: If the Status LED is solid red—STOP—return the controller to an authorized repair center.

CAUTION: Leave the coil EEPROM cable in place if removing the controller for service. The EEPROM maintains system settings for the coil location and will automatically update the new controller.

5. To setup and verify proper deactivation for the ZBAMB5278A Pro deactivator coils, see ZBAMB5278A Pro EAS Label Deactivator Coils Setup Guide 8200-0054-41.

For more information about the controller, see ZBAMB9010-IPS EAS Label Deactivator Controller Installation Guide 8200-0747-24.

Secure using

a cable tie.