zdot data center cooling
TRANSCRIPT
-
7/31/2019 Zdot Data Center Cooling
1/4
1
Darshi
Dhaliw
al
2
0
1
1
ZdoT
D
ata
CenterAircon
ditioner
Toro Cooling System s have developed a com plete r ange of LOpexSensible Cooling solutions.Latest addition is ZdoT , an ener gy efficient sensible cooling Unitfor free cooling of data centers, which can rem ove large amount ofsensible heat from high power ser vers using a combination ofIndirect Adiabatic Cooling Pr ocess and integr ated compr essionrefrigeration.The process saves mor e than 5 0 to 7 0 % % energy on annualizedbasis, depending on the geographical location of the data cen ter .
Team LOpexTORO COOLING SYSTEM S PVT. LTD
+ 9 1 9 1 5 8 0 0 9 4 8 4+ 9 1 2 1 1 4 2 3 2 1 5 9
-
7/31/2019 Zdot Data Center Cooling
2/4
2
DATA CENTER COOLIN G
Problem:
Ener gy costs in India ar e cons tant ly r ising and
power gr ids ar e already pushed to the limitsAt t he sam e time, energy consum ption of ICT
facil it ies / data centers is increasing at a
prodigious rat e due to geomet ric r ise in
computing. Cooling energy costs in most cases
exceed 6 0 % of total energy used.
Some of the old data cent r es still use m ixed
flow ventilation and have very poor equipm ent
layouts.
M any a tim e, adhoc CRAC additions and
positioning is resor ted to address the hot spot
pr oblems . Litt le or No att ention is paid to
energy efficiency.
Although, globally, Hot aisle/ Cold aisle concept
is now considered one of the essential low
hanging fruit type of techn ique to contr ol
energy wastage but this practice is still not very
will recognised in India
As Dat a cent er cooling plays a significant r ole
in planning, owning and operat ing data center ,m any data centers have started paying
attention to energy use at their facilities.
Now building codes will also put pres sur e on
thes e facilities to reduc e the ener gy use by
adopting more energy efficient technology.
Simple Solution :
Heat Load:
As th e conventional refr igeration bas ed, off the
shelf equipm ent is not s uitable for t his
application h ence t he CRACs (r ead sensiblecooling machines) were introduced for
removing sensible heat from these buildings.
CRACSs are designed to pr imar ily r em ove
sensible heat loads and hence will not
dehum idify the air.
In pr actice it is extr em ely difficult, energy
intensive and expensive solution.
Toro c ooling System s is intr oducing LOpex
ZdoT air con ditioner, the advanced Indirec tAdiabatic Cooling system based on sensible
cooling t echnology.
LOpex ZdoT air conditioners meet new
ASHRAE guide lines for sensible cooling of data
center s at th e lowest oper ating cost while
reducing green house gas emissions and use
of chemical refr igerant s.
LOpex ZdoT air conditioners nor m ally work in
indirect adiabatic cooling mode but are also
fitted with r efrigerat ive back up for t hose
humid days when ambient air does not provide
adequate c apacity as a h eat sink.The cooling
pr ocess offers fail safe option for cont inuous
heat rem oval besides ensur ing annualized
energy savings exceeding 5 0 to 7 0 % also .
Sensible Cooling option for Data centers & ICT facilities
-
7/31/2019 Zdot Data Center Cooling
3/4
3
Principle:LOpex ZdoT is based o n the benefi t s of
evaporat ive Refr igera t ion w i thout the
disadvantages of adding any m oisture to t heretu rn or supply a ir .
Sensib le coo l ing o f the ho t re tu rn a i r f rom the
data center t akes place at th e Tw in Polymer
p la te heat exchanger w ork ing in tandem .
The return a ir is cooled by t he adiabatical ly
cooled outside air . This out side air does not
com e in d irect cont act the recirculat ing air as
can be seen in th e f igure above.
Further
cool ing i f
desired can
be achieved
using a
chil led
wa te r o r DX
coil. This
pre cooled
air can also
be rou ted
t o t h e
exist ing
CRACs. U se
of th ese
unit s can
n o w b e
contro l led
to a f te r
coolin g, as
and when requ i red .
Lopex ZdoT air condi t ioners use a d edicated
m icroprocessor based contr o l system s for
unint rupp ted, effect ive and precise process
contro l and energy e f f icien t opera t ion .
Benefits1 . Lowest Operating Cost2 . Usage of Free Cooling3 . Lowest back up Power4 . Lowest m aintenance cost5 . No Chemical refr igerant used6 . Lowest carbon foot print7 . Year r ound uninter rupted operation
W eather it is Data center or any other high sensible heat factor (SHF)
applicat ion, LOpex offers most energy efficient and eco fr iendly solutions.
-
7/31/2019 Zdot Data Center Cooling
4/4
4
Compat ibility with raised floorsLOpex ZdoT air condi t ioners are com patib le
w ith Raised f loors and Isle isolat ion
Raised f loo rs reduce the op erat ing cost of HVAC
system s by l imi t ing the supply of cold a ir to t he
m axim um he igh t o f t he rack. Iso la t ion o f co ld
isle and hot is le ensures opt im um use of th is
expensive resource.
Gradual ly, because of t he poo r avai labi l i ty of
e lectr ical energy and constantly r is ing energy
costs Isle isolation i s bein g accept ed in t he
Indian data centre in sta l lat ion s.
Product profile
Capaci ty 25-100 kW out put Low connected load
M otor ised Backward curve fans
Int egral VFD and Plc Cont rol Suit able fo r use in high SHF buil dings
such as Data centers, Sw itch r oom s,
industr ia l process contro l room s and
m ission crit ical facil i t i es.
Variants avai lable for Indirect Directevaporat ive cool ing aided by integrated
chil ler
Nom inal a ir ou tpu t fo r Return / supp lya i r f rom 7500 M 3/ Hr onw ar ds
Construct ion op t ionsGI pow der coated or sta in less steel
Low est w ater use Can use STP/ Bore w el l w ater for
cool ing
Un it capacity 7000 CFM
Supply a ir tem peratur e 20-23C
T over the servers 12 C
M oving parts Fans and pum ps
Avg. Cool ing capacity 25 KW
M ax Inpu t power 5 KW e
Supply air t emper at ure will always remain sta ble, duet o dependence of the heat sink on fixed ADP. Even if
t he ambient condit ions reach 45 C and humidity
rea ches satur at ion, the supply air conditions rema in
stable
LOpex ZdoT air condit ioners- Best answer for Dat a Center Cooling