    ZdoT

    D

    ata

    CenterAircon

    ditioner

    Toro Cooling System s have developed a com plete r ange of LOpexSensible Cooling solutions.Latest addition is ZdoT , an ener gy efficient sensible cooling Unitfor free cooling of data centers, which can rem ove large amount ofsensible heat from high power ser vers using a combination ofIndirect Adiabatic Cooling Pr ocess and integr ated compr essionrefrigeration.The process saves mor e than 5 0 to 7 0 % % energy on annualizedbasis, depending on the geographical location of the data cen ter .

    Team LOpexTORO COOLING SYSTEM S PVT. LTD

    + 9 1 9 1 5 8 0 0 9 4 8 4+ 9 1 2 1 1 4 2 3 2 1 5 9

  • 7/31/2019 Zdot Data Center Cooling

    2/4

    2

    DATA CENTER COOLIN G

    Problem:

    Ener gy costs in India ar e cons tant ly r ising and

    power gr ids ar e already pushed to the limitsAt t he sam e time, energy consum ption of ICT

    facil it ies / data centers is increasing at a

    prodigious rat e due to geomet ric r ise in

    computing. Cooling energy costs in most cases

    exceed 6 0 % of total energy used.

    Some of the old data cent r es still use m ixed

    flow ventilation and have very poor equipm ent

    layouts.

    M any a tim e, adhoc CRAC additions and

    positioning is resor ted to address the hot spot

    pr oblems . Litt le or No att ention is paid to

    energy efficiency.

    Although, globally, Hot aisle/ Cold aisle concept

    is now considered one of the essential low

    hanging fruit type of techn ique to contr ol

    energy wastage but this practice is still not very

    will recognised in India

    As Dat a cent er cooling plays a significant r ole

    in planning, owning and operat ing data center ,m any data centers have started paying

    attention to energy use at their facilities.

    Now building codes will also put pres sur e on

    thes e facilities to reduc e the ener gy use by

    adopting more energy efficient technology.

    Simple Solution :

    Heat Load:

    As th e conventional refr igeration bas ed, off the

    shelf equipm ent is not s uitable for t his

    application h ence t he CRACs (r ead sensiblecooling machines) were introduced for

    removing sensible heat from these buildings.

    CRACSs are designed to pr imar ily r em ove

    sensible heat loads and hence will not

    dehum idify the air.

    In pr actice it is extr em ely difficult, energy

    intensive and expensive solution.

    Toro c ooling System s is intr oducing LOpex

    ZdoT air con ditioner, the advanced Indirec tAdiabatic Cooling system based on sensible

    cooling t echnology.

    LOpex ZdoT air conditioners meet new

    ASHRAE guide lines for sensible cooling of data

    center s at th e lowest oper ating cost while

    reducing green house gas emissions and use

    of chemical refr igerant s.

    LOpex ZdoT air conditioners nor m ally work in

    indirect adiabatic cooling mode but are also

    fitted with r efrigerat ive back up for t hose

    humid days when ambient air does not provide

    adequate c apacity as a h eat sink.The cooling

    pr ocess offers fail safe option for cont inuous

    heat rem oval besides ensur ing annualized

    energy savings exceeding 5 0 to 7 0 % also .

    Sensible Cooling option for Data centers & ICT facilities

  • 7/31/2019 Zdot Data Center Cooling

    3/4

    3

    Principle:LOpex ZdoT is based o n the benefi t s of

    evaporat ive Refr igera t ion w i thout the

    disadvantages of adding any m oisture to t heretu rn or supply a ir .

    Sensib le coo l ing o f the ho t re tu rn a i r f rom the

    data center t akes place at th e Tw in Polymer

    p la te heat exchanger w ork ing in tandem .

    The return a ir is cooled by t he adiabatical ly

    cooled outside air . This out side air does not

    com e in d irect cont act the recirculat ing air as

    can be seen in th e f igure above.

    Further

    cool ing i f

    desired can

    be achieved

    using a

    chil led

    wa te r o r DX

    coil. This

    pre cooled

    air can also

    be rou ted

    t o t h e

    exist ing

    CRACs. U se

    of th ese

    unit s can

    n o w b e

    contro l led

    to a f te r

    coolin g, as

    and when requ i red .

    Lopex ZdoT air condi t ioners use a d edicated

    m icroprocessor based contr o l system s for

    unint rupp ted, effect ive and precise process

    contro l and energy e f f icien t opera t ion .

    Benefits1 . Lowest Operating Cost2 . Usage of Free Cooling3 . Lowest back up Power4 . Lowest m aintenance cost5 . No Chemical refr igerant used6 . Lowest carbon foot print7 . Year r ound uninter rupted operation

    W eather it is Data center or any other high sensible heat factor (SHF)

    applicat ion, LOpex offers most energy efficient and eco fr iendly solutions.

  • 7/31/2019 Zdot Data Center Cooling

    4/4

    4

    Compat ibility with raised floorsLOpex ZdoT air condi t ioners are com patib le

    w ith Raised f loors and Isle isolat ion

    Raised f loo rs reduce the op erat ing cost of HVAC

    system s by l imi t ing the supply of cold a ir to t he

    m axim um he igh t o f t he rack. Iso la t ion o f co ld

    isle and hot is le ensures opt im um use of th is

    expensive resource.

    Gradual ly, because of t he poo r avai labi l i ty of

    e lectr ical energy and constantly r is ing energy

    costs Isle isolation i s bein g accept ed in t he

    Indian data centre in sta l lat ion s.

    Product profile

    Capaci ty 25-100 kW out put Low connected load

    M otor ised Backward curve fans

    Int egral VFD and Plc Cont rol Suit able fo r use in high SHF buil dings

    such as Data centers, Sw itch r oom s,

    industr ia l process contro l room s and

    m ission crit ical facil i t i es.

    Variants avai lable for Indirect Directevaporat ive cool ing aided by integrated

    chil ler

    Nom inal a ir ou tpu t fo r Return / supp lya i r f rom 7500 M 3/ Hr onw ar ds

    Construct ion op t ionsGI pow der coated or sta in less steel

    Low est w ater use Can use STP/ Bore w el l w ater for

    cool ing

    Un it capacity 7000 CFM

    Supply a ir tem peratur e 20-23C

    T over the servers 12 C

    M oving parts Fans and pum ps

    Avg. Cool ing capacity 25 KW

    M ax Inpu t power 5 KW e

    Supply air t emper at ure will always remain sta ble, duet o dependence of the heat sink on fixed ADP. Even if

    t he ambient condit ions reach 45 C and humidity

    rea ches satur at ion, the supply air conditions rema in

    stable

    LOpex ZdoT air condit ioners- Best answer for Dat a Center Cooling