zeiss callisto eye

5
CALLISTO eye from ZEISS Computer assisted cataract surgery EN_32_010_0008II CALLISTO eye, OPMI LUMERA, IOLMaster, Z ALIGN, K TRACK and FORUM are registered trademarks of Carl Zeiss Meditec AG. The contents of the brochure may differ from the current status of approval of the product in your country. Please contact our regional representative for more information. Subject to change in design and scope of delivery and as a result of ongoing technical development. Printed on elemental chlorine-free bleached paper. © 2016 by Carl Zeiss Meditec AG. All copyrights reserved. Carl Zeiss Meditec AG Goeschwitzer Strasse 51–52 07745 Jena Germany www.zeiss.com/med/contacts www.zeiss.com/callisto-eye CALLISTO eye IOLMaster 500 IOLMaster 700 FORUM OPMI LUMERA 700 OPMI Lumera i S7 / OPMI Lumera S88 / OPMI Lumera T EDIS // PRECISION MADE BY ZEISS 0297 When you achieve precise 1 results fast 2 . ZEISS Cataract Suite markerless

Upload: dinhkhanh

Post on 04-Jan-2017

269 views

Category:

Documents


1 download

TRANSCRIPT

CALLISTO eye from ZEISSComputer assisted cataract surgery

EN_3

2_01

0_00

08II

CALL

ISTO

eye

, OPM

I LUM

ERA,

IOLM

aste

r, Z

ALIG

N, K

TRA

CK a

nd F

ORU

M a

re re

gist

ered

trad

emar

ks o

f Car

l Zei

ss M

edite

c AG

.Th

e co

nten

ts o

f the

bro

chur

e m

ay d

iffer

from

the

curre

nt s

tatu

s of

app

rova

l of t

he p

rodu

ct in

you

r cou

ntry

. Ple

ase

cont

act o

ur re

gion

al re

pres

enta

tive

for m

ore

info

rmat

ion.

Subj

ect t

o ch

ange

in d

esig

n an

d sc

ope

of d

eliv

ery

and

as a

resu

lt of

ong

oing

tech

nica

l dev

elop

men

t. Pr

inte

d on

ele

men

tal c

hlor

ine-

free

blea

ched

pap

er.

© 2

016

by C

arl Z

eiss

Med

itec

AG. A

ll co

pyrig

hts

rese

rved

.

Carl Zeiss Meditec AG Goeschwitzer Strasse 51–5207745 JenaGermanywww.zeiss.com/med/contacts

www.zeiss.com/callisto-eye

CALLISTO eyeIOLMaster 500IOLMaster 700FORUM

OPMI LUMERA 700OPMI Lumera iS7 / OPMI LumeraS88 / OPMI Lumera TEDIS

// PRECISION MADE BY ZEISS

0297

When you achieve precise1 results fast2.ZEISS Cataract Suite markerless

2 9

ZEISS CALLISTO eye touchscreen monitor

Touchscreen Projected Capacitive Touch (PCT) with externed transparencyTemperature range +10°C to +35 °C (+50°F to +95°F)Scratch-proof

Processor Intel® Core i7 620M 2.66GHz

Hard drive SATA, 500 GB

Display Integrated 22" color flat-screen with high luminosity and wide viewing angle

Video signals PAL 576i50; NTSC 480i60; 1080i50; 1080i60Full functionality and usability in conjunction with ZEISS CALLISTO eye is only possible with camera models from Carl Zeiss Meditec AG

Ports 1× CAN-Bus, 1× RS232, 2 × 1Gigabit Ethernet, 5 × USB2.0, 1 × potential equalization

Video input 1× Y/C, 1× HD-SDI

Video output 1× VGA, 2 × HDMI

Connectivity Integrated RJ45 10 / 100Base-T Ethernet port for connection to ZEISS OPMI LUMERA 700 and hospital network

Power supply Integrated fanless 150 W medical power supply

Weight 14 kg

Supported languages German, English, French, Italian, Spanish, Japanese, Finnish, Danish, Nowegian, Swedish, Portugese/Brazilian, Russian, Dutch

Convenient DocumentationFor high quality videos and photos

HD video recording

including assistance functions overlay

• High-quality video recording and photos

HD video recording and photos that include the assistance

functions allow you for example to document the correct

position of the toric IOL. The quality of the videos and

photos meet even the most demanding requirements in

quality management, teaching and presentations.

• Opens up new patient marketing possibilities

You can give every patient a video of their surgery. A video

frame in the microscope eyepiece shows which part of the

operating field is being recorded.

• Connectivity

Receivce patient data ( DMWL) electronically to

avoid spelling errors and to save time. Archive

all videos and photos in ZEISS FORUM via DICOM

to make them accessible from anywhere in the

hospital.

• A better overview

Live video is shown full screen so that the operating

team can easily follow the course of the surgery.

CompatibilityWhich product works with which CALLISTO eye function

ZEISS OPMI LUMERA 700with IDIS

ZEISS OPMI LUMERA family1 with EDIS

ZEIS

S C

ALL

ISTO

eye

ASS

ISTA

NC

E m

arke

rles

s

ZEIS

S C

ALL

ISTO

eye

ASS

ISTA

NC

E

ZEIS

S C

ALL

ISTO

eye

BA

SIC High quality video and photo documentation • •

Mounting options

– Floor stand of the ZEISS surgical microscope •

– Ceiling mount •

– Wheeled stand • •

– Table stand • •

Full remote control of surgical microscope •

Control ZEISS CALLISTO eye via foot control panel of the ZEISS surgical micrsocope

• •

Display ZEISS IOLMaster 500 or 700 patient report via USB2 or Network • •

Superimpose OPMI settings on video screen or eyepiece •

Show video frame as a guide in the eyepiece • •

Archive videos and photos via DICOM • •

Assistant functions in the eyepiece: Incision / LRI, Rhexis, Z ALIGN • •

K TRACK for visualization of corneal curvature3 •

Prepare surgery wizard to safe valuable OR time • •

Using Incision / LRI, Z ALIGN without corneal markers (markerless) • •

Use of ZEISS IOLMaster 500 or 700 patient data • •

1S88 / OPMI Lumera T, OPMI Lumera i, S7 / OPMI Lumera 2 From ZEISS IOLMaster 500 with toric option. 3 Keratoscope of ZEISS OPMI LUMERA 700 required.

Z ALIGN – toric assistant defines the reference and target axes and displays them on-screen and in the eyepiece, assisting the surgeon in the alignment of toric IOLs.

Technical DataCALLISTO eye from ZEISS

5 6 3

ZEISS CALLISTO eyePrecise 1,3,4 premium IOL surgery made easy

Computer assisted cataract surgery with CALLISTO eye® from ZEISS makesprecise1,3,4, premium IOL surgery fast and easy! It helps you meet patientexpectations today and tomorrow with assistance functions projecteddirectly in your surgical field.

ASSISTANCE FUNCTIONS

For surgical precision 3,4,5

PERFECT INTEGRATION

For a streamlined workflow

CONVENIENT DOCUMENTATION

For high quality videos and photos

• Precise1 & markerless alignment of toric IOLs:

Z ALIGN® from ZEISS (toric assistant)

• Support to ensure treatment of correct eye and patient

• Center the IOL along the visual axis of the patient

• Perfom a precisely shaped and sized capsulorhexis1,4

• Create incisions where and of the size you had intended

• View the assisting information in the eyepiece

• Control the ZEISS CALLISTO eye from the foot control panel

or handgrips of the OPMI LUMERA® family5 surgical

microscope from ZEISS

• Get the report from IOLMaster® 500 or 700 from ZEISS with

all relevant biometry data available for review in the OR

• Ergonomic and comfortable for the surgeon and the

OR staff

• HD video recording and photos that include the assistance

functions meet even the most demanding requirements in

quality management, teaching and for presentations

• Import patient lists via a network connection and DICOM

modality worklist or USB stick

• Export videos and photos via a DICOM network connection

or USB stick

• OR team can easily follow surgery progress with the full

screen video

Perfect IntegrationFor a streamlined workflow

Alternatively ZEISS CALLISTO eye

can be mounted directly to the

floorstand or ceiling mount of ZEISS

OPMI LUMERA 700 so that it takes

up no extra space and is always

where you need it.

The optional roll stand or table-top

stand allows the ZEISS CALLISTO eye

to be freely positioned anywhere in

the room.

Data Injection Systems

For maximum comfort, all assistance

functions can be injected into the

eyepiece of your surgical microscope.

Both data injection systems – IDIS* for

ZEISS OPMI LUMERA 700 and EDIS**

for all other ZEISS OPMI LUMERA family5

surgical microscopes – are protected

from being knocked out of alignment.

The high-resolution, high-contrast color

image allows you to work stress free

and ergonomically.

ZEISS CALLISTO eye works as one with the ZEISS OPMI LUMERA family5

of surgical microscopes. View all assistance information in your surgical

field and control ZEISS CALLISTO eye from the foot control panel of

the surgical microscope. The connection with ZEISS FORUM and the

ZEISS IOLMaster 500 or 700 provides you seamless access to diagnostic

reports of your patients in the OR. The flexible mounting options allow

to integrate ZEISS CALLISTO eye into your OR environment and with your

team for a streamlined cataract workflow.

* Integrated Data Injection System ** External Data Injection System

ZEISS Cataract Suite markerlessFor precise1 markerless toric IOL alignment

• Products designed to work together for a high level of precision1

and efficiency by skipping manual steps for toric IOL alignment

• Efficient and reliable data transfer from biometry to surgery

• No manual eye marking

OPMI LUMERA family5 FORUM6 CALLISTO eyeIOLMaster 700

1. Clinical data of Prof. Findl / Dr. Hirnschall presented at ESCRS 2013 – technically verifyed pre-/ intraoperative matching precision ± 1.0° in mean2. Study of Dr. Wolfgang Mayer at LMU, Munich, Germany. Data on file.3. Lackerbauer, C. Modern Solutions for Refractive Cataract Surgery: CALLISTO eye. Cataract & Refractive Surgery Today. February 2013.4. Findl, O. Complications of the CCC. Cataract & Refractive Surgery Today Europe. March 20125. OPMI LUMERA 700, S88 / OPMI Lumera T, OPMI Lumera i, S7 / OPMI Lumera6. Or other compatible DICOM systems

4

Assistance FunctionsFor surgical precision1,3,4

Incision / LRI assistant

Superimpose the exact

position and size of

your incisions to ensure

precise1,3,4 surgery.

Rhexis assistant

Superimpose the exact

shape and size of the

capsulorhexis and center

the IOL along the optical

axis of the patient eye.

K TRACK®

Visualize corneal curvature

in combination with a

keratoscope, e.g. in corneal

transplantations.

ZEISS CALLISTO eye facilitates your premium IOL

surgeries. The assistance functions are injected directly

into the eyepiece of your ZEISS OPMI LUMERA family5

surgical microscope, providing improved ergonomics

without distraction from the surgical field.

In addition, ZEISS CALLISTO eye is equipped with

automated eye tracking, ensuring that the position of

the superimposed assistance functions are properly

positioned on the eye.

Z ALIGN – toric assistant

Inject reference axis and

target axis in your microscope

eyepiece to ensure precise1,3,4

toric IOL alignment without

corneal markers.