zelio control rm4tu02

7
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Mar 20, 2015 1 Product data sheet Characteristics RM4TU02 three-phase network control relay RM4-T - range 300..430 V Main Range of product Zelio Control Product or component type Industrial measurement and control relays Relay type Control relay Product specific appli- cation For 3-phase supply Relay name RM4-T Relay monitored pa- rameters Phase failure detection Phase sequence Undervoltage detection Time delay Without time delay Measurement range 290...484 V Contacts type and com- position 2 C/O Poles description 3P Complementary [Us] rated supply voltage 380...440 V 50/60 Hz Control threshold undervoltage 300...430 V Output contacts 2 C/O Setting accuracy of the switching threshold +/-3 % Switching threshold drift <= 0.5 % within the measuring range <= 0.06 % per degree centigrade depending permissible ambient air temperature Setting accuracy of time delay 10 P Time delay drift <= 0.5 % within the measuring range <= 0.07 % per degree centigrade depending on the rated operational temperature Hysteresis 5 % fixed of de-energisation threshold Delay at power up < 650 ms Measuring cycle <= 80 ms Marking CE : EMC 89/336/EEC CE : LVD 73/23/EEC Overvoltage category III conforming to IEC 60664-1 [Ui] rated insulation voltage 500 V conforming to IEC Supply frequency 50/60 Hz +/- 5 % Operating position Any position without Connections - terminals Screw terminals 2 x 2.5 mm², flexible cable without cable end Screw terminals 2 x 1.5 mm², flexible cable with cable end Tightening torque 0.6...1.1 N.m Mechanical durability <= 30000000 cycles [Ith] conventional free air thermal current 8 A [Ie] rated operational current 0.3 A at 70 °C 115 V DC-13 conforming to VDE 0660 0.3 A at 70 °C 115 V DC-13 conforming to IEC 60947-5-1/1991 0.1 A at 70 °C 250 V DC-13 conforming to VDE 0660 0.1 A at 70 °C 250 V DC-13 conforming to IEC 60947-5-1/1991 3 A at 70 °C 250 V AC-15 conforming to VDE 0660 3 A at 70 °C 250 V AC-15 conforming to IEC 60947-5-1/1991 3 A at 70 °C 24 V AC-15 conforming to VDE 0660 3 A at 70 °C 24 V AC-15 conforming to IEC 60947-5-1/1991 3 A at 70 °C 115 V AC-15 conforming to VDE 0660 3 A at 70 °C 115 V AC-15 conforming to IEC 60947-5-1/1991 2 A at 70 °C 24 V DC-13 conforming to VDE 0660 2 A at 70 °C 24 V DC-13 conforming to IEC 60947-5-1/1991 Switching capacity in mA 10 mA at 12 V

Upload: matko-zaja

Post on 17-Jan-2016

8 views

Category:

Documents


0 download

DESCRIPTION

zelio

TRANSCRIPT

Page 1: Zelio Control RM4TU02

The

info

rmat

ion

prov

ided

in th

is d

ocum

enta

tion

cont

ains

gen

eral

des

crip

tions

and

/or t

echn

ical

cha

ract

eris

tics

of th

e pe

rform

ance

of t

he p

rodu

cts

cont

aine

d he

rein

.Th

is d

ocum

enta

tion

is n

ot in

tend

ed a

s a

subs

titut

e fo

r and

is n

ot to

be

used

for d

eter

min

ing

suita

bilit

y or

relia

bilit

y of

thes

e pr

oduc

ts fo

r spe

cific

use

r app

licat

ions

.It

is th

e du

ty o

f any

suc

h us

er o

r int

egra

tor t

o pe

rform

the

appr

opria

te a

nd c

ompl

ete

risk

anal

ysis

, eva

luat

ion

and

test

ing

of th

e pr

oduc

ts w

ith re

spec

t to

the

rele

vant

spe

cific

app

licat

ion

or u

se th

ereo

f.N

eith

er S

chne

ider

Ele

ctric

Indu

strie

s SA

S no

r any

of i

ts a

ffilia

tes

or s

ubsi

diar

ies

shal

l be

resp

onsi

ble

or li

able

for m

isus

e of

the

info

rmat

ion

cont

aine

d he

rein

.

Mar 20, 20151

Product data sheetCharacteristics

RM4TU02three-phase network control relay RM4-T -range 300..430 V

MainRange of product Zelio ControlProduct or componenttype

Industrial measurement and control relays

Relay type Control relayProduct specific appli-cation

For 3-phase supply

Relay name RM4-TRelay monitored pa-rameters

Phase failure detectionPhase sequenceUndervoltage detection

Time delay Without time delayMeasurement range 290...484 VContacts type and com-position

2 C/O

Poles description 3P

Complementary[Us] rated supply voltage 380...440 V 50/60 HzControl threshold undervoltage 300...430 VOutput contacts 2 C/OSetting accuracy of the switching threshold +/-3 %Switching threshold drift <= 0.5 % within the measuring range

<= 0.06 % per degree centigrade depending permissible ambient air temperatureSetting accuracy of time delay 10 PTime delay drift <= 0.5 % within the measuring range

<= 0.07 % per degree centigrade depending on the rated operational temperatureHysteresis 5 % fixed of de-energisation thresholdDelay at power up < 650 msMeasuring cycle <= 80 msMarking CE : EMC 89/336/EEC

CE : LVD 73/23/EECOvervoltage category III conforming to IEC 60664-1[Ui] rated insulation voltage 500 V conforming to IECSupply frequency 50/60 Hz +/- 5 %Operating position Any position withoutConnections - terminals Screw terminals 2 x 2.5 mm², flexible cable without cable end

Screw terminals 2 x 1.5 mm², flexible cable with cable endTightening torque 0.6...1.1 N.mMechanical durability <= 30000000 cycles[Ith] conventional free air thermal current 8 A[Ie] rated operational current 0.3 A at 70 °C 115 V DC-13 conforming to VDE 0660

0.3 A at 70 °C 115 V DC-13 conforming to IEC 60947-5-1/19910.1 A at 70 °C 250 V DC-13 conforming to VDE 06600.1 A at 70 °C 250 V DC-13 conforming to IEC 60947-5-1/19913 A at 70 °C 250 V AC-15 conforming to VDE 06603 A at 70 °C 250 V AC-15 conforming to IEC 60947-5-1/19913 A at 70 °C 24 V AC-15 conforming to VDE 06603 A at 70 °C 24 V AC-15 conforming to IEC 60947-5-1/19913 A at 70 °C 115 V AC-15 conforming to VDE 06603 A at 70 °C 115 V AC-15 conforming to IEC 60947-5-1/19912 A at 70 °C 24 V DC-13 conforming to VDE 06602 A at 70 °C 24 V DC-13 conforming to IEC 60947-5-1/1991

Switching capacity in mA 10 mA at 12 V

Page 2: Zelio Control RM4TU02

2

Switching voltage 250 V AC<= 440 V AC

Contacts material 90/10 silver nickel contactsNumber of cables 2Height 78 mmWidth 22.5 mmDepth 80 mmTerminals description ISO n°1 (15-16-18)OC

(25-26-28)OC(L1-L2-L3)COALT

Output relay state Tripped, fault present9 mm pitches 2.5Product weight 0.11 kgTerminals description ISO n°2 (11-12-14)OC

(21-22-24)OC(L1-L2-L3)COALT

EnvironmentStandards EN/IEC 60255-6Product certifications CSA

GLUL

Ambient air temperature for storage -40...85 °CAmbient air temperature for operation -20...65 °CRelative humidity 15...85 % 3K3 conforming to IEC 60721-3-3Vibration resistance 0.35 ms (f = 10...55 Hz) conforming to IEC 60068-2-6Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27IP degree of protection IP50 (casing) conforming to IEC 60529

IP20 (terminals) conforming to IEC 60529Pollution degree 3 conforming to IEC 60664-1Dielectric test voltage 2.5 kVNon-dissipating shock wave 4.8 kVResistance to electrostatic discharge 8 kV air conforming to IEC 61000-4-2 level 3

6 kV contact conforming to IEC 61000-4-2 level 3Resistance to electromagnetic fields 10 V/m conforming to IEC 61000-4-3 level 3Resistance to fast transients 2 kV conforming to IEC 61000-4-4 level 3Protection against electric shocks 2 kV conforming to IEC 61000-4-5 level 3Disturbance radiated/conducted CISPR 11 group 1 - class A

CISPR 22 - class A

Page 3: Zelio Control RM4TU02

3

Product data sheetDimensions Drawings

RM4TU02

3-phase Supply Control Relays

Dimensions

Page 4: Zelio Control RM4TU02

4

Product data sheetMounting and Clearance

RM4TU02

3-phase Supply Control Relays

Rail mounting

Screw fixing

Page 5: Zelio Control RM4TU02

5

Product data sheetConnections and Schema

RM4TU02

3-Phase Supply Control Relays

Wiring Diagram

L1,L2,L3

Supply to be monitored

15(11)-18(14),15(11)-16(12)

1st C/O contact of the output relay

25(21)-28(24),25(21)-26(22)

2nd C/O contact of the output relay

Application Scheme

Example

(1) Fault

Page 6: Zelio Control RM4TU02

6

Product data sheetPerformance Curves

RM4TU02

Electrical Durability and Load Limit Curves

AC LoadCurve 1: Electrical durability of contacts on resistive load in millions of operating cycles

X Current broken in AY Millions of operating cyclesCurve 2: Reduction factor k for inductive loads (applies to values taken from durability Curve 1)

X Power factor on breaking (cos φ)Y Reduction factor K

Example: An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.5 A and cos φ =0.3.For 0.5 A, curve 1 indicates a durability of approximately 1.5 million operating cycles.As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2.For cos φ = 0.3: k = 0.6The electrical durability therefore becomes:

1.5 x 106 operating cycles x 0.6 = 900 000 operating cycles

DC LoadLoad limit curve

X Current in AY Voltage in V1 L/R = 20 ms2 L/R with load protection diode3 Resistive load

Page 7: Zelio Control RM4TU02

7

Product data sheetTechnical Description

RM4TU02

Function Diagram

Undervoltage Detection Only

t Fixed time delay = 550 msU 3-phase supply voltage monitored (between terminals L1, L2 and L3)S Overvoltage or undervoltage setting15/18,15/16;25/28,25/26

Output relays connections (refer to Connections and Schema)

Relay status: black color = energized.