zero-touch energy audit -...

18
Zero-Touch Energy Audit - Finding a Automated Solution for Energy Audit ?

Upload: lethuy

Post on 12-Mar-2018

223 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

Zero-Touch Energy Audit - Finding a Automated Solution for Energy Audit

?

Page 2: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

NPCL NOIDA POWER COMPANY LIMITED

NPCL is a joint venture between RP-Sanjiv Goenka Group, a leading

business house in India and Greater Noida Industrial Development

Authority, an autonomous body of U.P. Government responsible for town

planning and infrastructure development.

Operational Area: 335 sq.km Customer Base: 85 K

MVA Peak Load: 180 MVA 10x Increase in

Customer Base & Peak

Load

Page 3: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

33 kV Substation

33/11 kV Substation

Transformer

M3

M2

M6 M7

M8

M9

M1

M4

M5

33 kV Consumer Meter

33 kV Consumer Meter

LT Consumer

Meters

11 kV Consumer Meter

Outgoing Meter

Incoming Meter

Outgoing Meter

Page 4: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

33/11 kV Substation

33 kV Substation

M1

M3

M2

M4

Loss = M1 – (M2 + M3 + M4)

33 kV Consumer Meter

33 kV Consumer Meter

Outgoing Meter

Incoming Meter

M1

M2 M3 M4

Page 5: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

33/11 kV Substation

Transformer

M5

M6

M7

M8

M9

Loss= M5 – (M6 + M7 + M8 + M9)

LT Consumer

Meters

11 kV Consumer Meter

Outgoing Meter

M5

M6 M7 M8 M9

Page 6: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

33/11 kV Substation

33 kV Substation

M1

M3

M2

M4

33/11 kV Substation

Transformer

M5

M6

M7

M8

M9

Loss= M1 – (M2 + M3 + …+ M9)

Pre-Requisite of Energy Audit = Meter Hierarchy

Tree.

Page 7: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

M

M M M

Establish

Hierarchy AU IT D Micro-Manage

Audit

Capture

Network

Updates

Accurately capture all the

Metering Points present in

the network and place them

in a logical hierarchical tree.

Micro-Manage Audit by

introducing more Meter

Levels in the hierarchical

tree.

Capture and update the

hierarchical tree in case of any

Network changes such as

Network Extension, Switching,

etc.

Page 8: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

33/11 kV Substation

33 kV Substation

M1

M3

M2

M4

Initiate Back Trace from Meter

Meter Encountered?

Consumer Meter?

Continue Back Tracing

Retrieve Meter Record from DB

Assign as Parent

Retrieve Next Meter Record from DB

No

Yes

Yes No

Page 9: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

Problem Statement:

Accurately capture all the Metering Points present in the network and place them in a logical hierarchical tree.

Solution:

For each Meter present in the DB, use back-tracing to find its Parent Meter (Non-Consumer).

Establish Hierarchy

M

M M M

Page 10: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

Substation Meter

DT Meter Consumer

Meter Auditing Error

Existing Hierarchy

Substation Meter

DT Meter Consumer

Meter Auditing Error

Boundary Meter

Division Meter

Newly Introduced Levels

Updated Hierarchy

Legends: Segment with excessive Energy Loss

Normal Segment

Large Area of Focus

Reduced Area of Focus

Page 11: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

Substation Level

Feeder Level

DT Level

Substation Level

Feeder Level

DT Level

Division Level

Boundary Level

Nodal Level

Switching Level

Pre-GIS

Post-GIS

Page 12: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

Problem Statement:

In the Existing levels of Hierarchy the “Inspection Area” (Area of Focus) is too big. This is resulting in higher rates of “Resolution Time”

Solution:

Introduce more layers (i.e. Meters) into the Hierarchical Tree in order increase the number of “Audit Sections” thereby reducing the Area of Focus.

Micro-Manage

Audit

AU IT D

Page 13: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

Substation

M1

Substation

M2

M3 M4

M5 M6

M7

Transformer

M1

M5 M3

M6 M7

M4

M2 Meter Hierarchy

Switch Closed Switch Open

Page 14: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

Substation

M1

Substation

M2

M3 M4

M5 M7

M8

Transformer

M1

M5 M3

M6 M7

M4

M2

Switch Open Switch Closed

Meter Hierarchy Updated

Page 15: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

Project Created in SAP

Design Created in GIS

Network Proposed in GIS

Proposed Network Approved

Nw Augmentation Started

Field Verification Done

Design Approved in GIS

Design Data Posted Design Data Synced

with SAP

Project Created in SAP

Design Created in GIS

Network Proposed in GIS

Proposed Network Approved

Nw Augmentation Started

Field Verification Done

Design Approved in GIS

Design Data Posted Design Data Synced

with SAP

Energy Audit Extract Triggered

Existing Process Flow

Updated Process Flow

Page 16: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

Problem Statement:

Update the Hierarchical Tree in case of any Network Changes such as Network Extensions, Network Switching, etc.

Solution:

Since all changes made to the network are routed via Business Process, update the Process Flow to trigger Energy Audit extract whenever Network Changes are captured.

Capture Network

Updates

Page 17: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

Since the Data is extract only after going through multiple layers of QAQC, the reliability of Energy Audit Reports is greatly enhanced

Enhanced Reliability

Introduction of Additional layers have drastically reduced the Timelines associated with locating the issue

Reduced

Processing Time

The triggering, extraction and delivery hierarchical tree is completely automated thereby eliminating any chance of user-related error.

Completely Automated

Solution is designed in such a way that any augmentation to the network (big/small) can easily be captured and passed on to the hierarchical tree.

Scalable Solution

Page 18: Zero-Touch Energy Audit - omangeospatialforum.orgomangeospatialforum.org/presentation/zero-touch-energy-audit... · Zero-Touch Energy Audit - Finding a Automated Solution for Energy

Red Planet Solutions 25-12, Level 25, Q-Sentral, 2A Jalan Stesen Sentral 2, Kuala Lumpur Sentral, 50470 Kuala Lumpur

Swami (Senior Consultant)

+91-9884183818

[email protected]