DRM/ZKF8KM2/030915/01 DRM/ZFK8KM2/030915/01 ZFK8/ZKM-2 IN-SITU ZIRCONIA ANALYSER ZFK8/ZKM-2 Zirconia Oxygen Gas Analyzers are used as combustion controllers in combustion facilities and industries which require high energy consumption. The oxygen concentration control ensures complete combustion, thus reducing CO2/SOx/NOx emissions and helping prevent air pollution. FEATURES - In-situ design with integrated detector filter - Max. Gas Temperature: -10°C to +600°C (flow rate version) -10°C to +1500°C (ejector version) - IP55 transmitter protection (options: IP66 or IP67) - Enhanced safety design with integrated and remote power isolation fuctions, including: Thermocouple failure Emergency power shut off Password protected menu functions - High speed response (4 to 7 seconds) - Modular detector design allow easy field replacement of zirconia element SPECIFICATIONS ZFK8/ZKM-2 Repeatability +/- 0.5% FS or less Drift +/- 2.0% FS or less per month Response Time 4 - 7 seconds Mounting Flange JIS5K 65A (80A for high dust) Tube Length Options 300mm to 1000mm Display 4 Digit backlit LCD Measured Gas Pressure -3 to +3 kPA Analogue Outputs 4-20mA DC or 0-1V DC Contact Output (Option) RS-485 Modbus or RS235 Modbus Power Supply 100 to 240V, 50/60Hz Consumption Approx. 100VA For more information, please feel free to contact our sales team (Contact details viewable below) Datasheet continues overleaf

Upload: lynhi

Post on 26-Mar-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ZFK8/ZKM-2 IN-SITU ZIRCONIA ANALYSER - DRM … ZKM-2 In-Situ Zirconia Analyser.pdfRM/ZKF8KM2/0015/01 RM/ZFK8KM2/0015/01 ZFK8/ZKM-2 IN-SITU ZIRCONIA ANALYSER ZFK8/ZKM-2 Zirconia Oxygen

DRM/ZKF8KM2/030915/01 DRM/ZFK8KM2/030915/01

ZFK8/ZKM-2 IN-SITU ZIRCONIA ANALYSERZFK8/ZKM-2 Zirconia Oxygen Gas Analyzers are used as combustion controllers in combustion facilities and industries which require high energy consumption. The oxygen concentration control ensures complete combustion, thus reducing CO2/SOx/NOx emissions and helping prevent air pollution.

FEATURES- In-situ design with integrated detector filter- Max. Gas Temperature: • -10°C to +600°C (flow rate version) • -10°C to +1500°C (ejector version)- IP55 transmitter protection (options: IP66 or IP67)- Enhanced safety design with integrated and remote power isolation fuctions, including: • Thermocouple failure • Emergency power shut off • Password protected menu functions- High speed response (4 to 7 seconds)- Modular detector design allow easy field replacement of zirconia element

SPECIFICATIONS

ZFK8/ZKM-2Repeatability +/- 0.5% FS or less

Drift +/- 2.0% FS or less per monthResponse Time 4 - 7 seconds

Mounting Flange JIS5K 65A (80A for high dust)Tube Length Options 300mm to 1000mm

Display 4 Digit backlit LCDMeasured Gas Pressure -3 to +3 kPA

Analogue Outputs 4-20mA DC or 0-1V DC

Contact Output (Option) RS-485 Modbus or RS235 Modbus

Power Supply 100 to 240V, 50/60HzConsumption Approx. 100VA

For more information, please feel free to contact our sales team

(Contact details viewable below)

Datasheet continues overleaf

Page 2: ZFK8/ZKM-2 IN-SITU ZIRCONIA ANALYSER - DRM … ZKM-2 In-Situ Zirconia Analyser.pdfRM/ZKF8KM2/0015/01 RM/ZFK8KM2/0015/01 ZFK8/ZKM-2 IN-SITU ZIRCONIA ANALYSER ZFK8/ZKM-2 Zirconia Oxygen

DRM/ZFK8KM2/030915/01 DRM/ZFK8KM2/030915/01

Model Method Gas & Ranges

ZFK8 Detector

ZKM Controller

Single Gas O2 (ZrO2):0-2/50% (in 1 vol% O2 steps)

Zero Gas:0.25 to 2.0% O2

Span Gas:20.6 to 21.0% O2

Typical Applications

Crematorium Combustion ControlBoiler MonitoringPower Generation

Petroleum RefiningPetrochemicalsManufacturing

Ejector Version.

Flow Tube Version.

Easy Change Detector.