ZXWR RNC Routine Maintenance
Applicable to Staff with Skill Certificate Level II or Lower
Released by GU Product Support Dept.
![Page 2: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/2.jpg)
Internal Only▲
Version Introduction
References:
1.
2.
Version Date Author Checked by
Amendment Record
R1.0 2011-03-24 Zhao chenmu *** None
![Page 3: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/3.jpg)
Internal Only▲
Course Objectives:
To understand the routine maintenance works
To master the routine maintenance works
![Page 4: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/4.jpg)
Internal Only▲
Content
Daily Maintenance
Weekly Maintenance
Monthly Maintenance
Quarterly Maintenance
![Page 5: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/5.jpg)
Internal Only▲
Daily Maintenance
Daily maintenance has four tasks: RNC environment check OMM server status check RNC MO( Managed Object ) status check RNC alarm audit
![Page 6: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/6.jpg)
Internal Only▲
Daily Maintenance—RNC environment check
Equipment Room Temperature
Recommended temperature: 15ºC to 30ºC. Humidity
Recommended humidity: 40% to 65%. Security
The burglarproof net, door and window are intact. Cleanness
The equipment room is tidy and clean without distinct dust.
![Page 7: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/7.jpg)
Internal Only▲
Daily Maintenance—OMM server status check
OMM client can login normally. Performance data can be exported normally. System configuration data backup policy running normally.
![Page 8: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/8.jpg)
Internal Only▲
Daily Maintenance—OMM server status check
OMM client can login normally. From client PC run ‘run-client’ icon and try to login.
![Page 9: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/9.jpg)
Internal Only▲
Daily Maintenance—OMM server status check
Performance data can be exported normally. Open PM GUI first.
![Page 10: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/10.jpg)
Internal Only▲
Daily Maintenance—OMM server status check
Performance data can be exported normally. In PM GUI, open ‘Performance Data Query’.
![Page 11: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/11.jpg)
Internal Only▲
Daily Maintenance—OMM server status check
Performance data can be exported normally. From pop up dialog, select ‘RNC-KPI index’ and click ok.
![Page 12: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/12.jpg)
Internal Only▲
Daily Maintenance—OMM server status check
If system can generate non-blank value it means PM work normally.
If all are blank value, please contact next level for troubleshooting.
![Page 13: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/13.jpg)
Internal Only▲
Daily Maintenance—OMM server status check
System configuration data backup policy running normally.
![Page 14: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/14.jpg)
Internal Only▲
Daily Maintenance—OMM server status check
From CM GUI, select ‘Management’ click ‘Data Recover’.
![Page 15: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/15.jpg)
Internal Only▲
Daily Maintenance—OMM server status check
In the ‘Data Recover’ dialog click ‘select’ button.
![Page 16: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/16.jpg)
Internal Only▲
Daily Maintenance—OMM server status check
In the open dialog, make sure the latest backup data time stamp is this morning.
![Page 17: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/17.jpg)
Internal Only▲
Daily Maintenance—RNC MO status check
RNC MO connected normally. In CM GUI check RNC MO connection is normal
status.
![Page 18: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/18.jpg)
Internal Only▲
Daily Maintenance—RNC MO status check
RNC configuration data modification indicator is ‘Blue color’ (nothing changed).
![Page 19: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/19.jpg)
Internal Only▲
Daily Maintenance—RNC Alarm Audit
Audit RNC real-time alarm
![Page 20: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/20.jpg)
Internal Only▲
Open Fault Management
Daily Maintenance—RNC Alarm Audit
![Page 21: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/21.jpg)
Internal Only▲
Export realtime alarms
Daily Maintenance—RNC Alarm Audit
![Page 22: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/22.jpg)
Internal Only▲
Save as .xls format
Daily Maintenance—RNC Alarm Audit
![Page 23: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/23.jpg)
Internal Only▲
Check RNC real-time alarm from the xls file.
Daily Maintenance—RNC Alarm Audit
![Page 24: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/24.jpg)
Internal Only▲
Daily Maintenance—RNC History Alarm Audit Open history alarms
![Page 25: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/25.jpg)
Internal Only▲
Click ‘quick search’ icon in History Alarm Query GUI
Daily Maintenance—RNC History Alarm Audit
![Page 26: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/26.jpg)
Internal Only▲
Select ‘Happen Time’ in the filter Time range set to 24 hours Then click ‘OK’ button.
Daily Maintenance—RNC History Alarm Audit
![Page 27: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/27.jpg)
Internal Only▲
After few seconds, 24 hours history alarms appears.
Daily Maintenance—RNC History Alarm Audit
![Page 28: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/28.jpg)
Internal Only▲
Export the history data and analysis RNC history alarms about 24 hours.
Daily Maintenance—RNC History Alarm Audit
![Page 29: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/29.jpg)
Internal Only▲
Open Notificatons
Daily Maintenance—RNC History Notifications Audit
![Page 30: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/30.jpg)
Internal Only▲
Audit Node B 24 hours history notifications Click ‘Quick Search’ icon.
Daily Maintenance—RNC History Notifications Audit
![Page 31: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/31.jpg)
Internal Only▲
Select ‘Happen Time’ in the filter Time range set to 24 hours Then click ‘OK’ button.
Daily Maintenance—RNC History Notifications Audit
![Page 32: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/32.jpg)
Internal Only▲
After few seconds, 24 hours history notifications appears.
Daily Maintenance—RNC History Notifications Audit
![Page 33: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/33.jpg)
Internal Only▲
Audit Node B 24 hours history notifications Export the history data and analysis the history
Node B notifications.
Daily Maintenance—RNC History Notifications Audit
![Page 34: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/34.jpg)
Internal Only▲
Content
Daily Maintenance
Weekly Maintenance
Monthly Maintenance
Quarterly Maintenance
![Page 35: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/35.jpg)
Internal Only▲
Weekly Maintenance
Weekly maintenance have two tasks OMM client virus scan. System configuration data export (XLS format).
![Page 36: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/36.jpg)
Internal Only▲
Weekly Maintenance—OMM client virus scan
Use Anti-virus software scan OMM client PC.
![Page 37: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/37.jpg)
Internal Only▲
Weekly Maintenance—System configuration data export (XLS format)
In CM GUI, select ‘RNC Managed Element’ MO.
![Page 38: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/38.jpg)
Internal Only▲
Weekly Maintenance—System configuration data export (XLS format)
After this, from menu bar add ‘RNC ManagedElement’ menu.
Select ‘Configuration Data Export Tool’ item.
![Page 39: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/39.jpg)
Internal Only▲
Weekly Maintenance—System configuration data export (XLS format)
In the pop up dialog has 6 pages. Click ‘Select All’ for each page.
![Page 40: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/40.jpg)
Internal Only▲
Weekly Maintenance—System configuration data export (XLS format)
Click ‘Export Data’ button.
![Page 41: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/41.jpg)
Internal Only▲
Weekly Maintenance—System configuration data export (XLS format)
Select save directory and wait few minutes.
![Page 42: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/42.jpg)
Internal Only▲
Weekly Maintenance—System configuration data export (XLS format)
System will generate a folder in your PC.
![Page 43: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/43.jpg)
Internal Only▲
Content
Daily Maintenance
Weekly Maintenance
Monthly Maintenance
Quarterly Maintenance
![Page 44: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/44.jpg)
Internal Only▲
Monthly Maintenance
Monthly maintenance have two tasks OMM server disk space check. NTP status check.
![Page 45: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/45.jpg)
Internal Only▲
Monthly Maintenance—OMM server disk space check
Delete old configuration data stored in OMM ../ums-svr\backup\sysmanager folder.
Use df –k to confirm system disk space.
![Page 46: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/46.jpg)
Internal Only▲
Monthly Maintenance—NTP status check
Check OMM server TOD time is the same with TOD source.
Check RNC TOD time is the same with OMM server.
![Page 47: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/47.jpg)
Internal Only▲
Monthly Maintenance—NTP status check
Check OMM server TOD time is the same with TOD source. In OMM server GUI, from ‘System’ menu select
‘Show System Time’ item.
![Page 48: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/48.jpg)
Internal Only▲
Monthly Maintenance—NTP status check
Check OMM server TOD time is the same with TOD source. In OMM server GUI, from ‘System’ menu select
‘Show System Time’ item.
![Page 49: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/49.jpg)
Internal Only▲
Monthly Maintenance—NTP status check
Compare the result with TOD source. Any time shift ask next level support.
![Page 50: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/50.jpg)
Internal Only▲
Monthly Maintenance—NTP status check
Check RNC TOD time is the same with OMM server. Double click ‘RNC Ground Resource Management’ MO
![Page 51: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/51.jpg)
Internal Only▲
Monthly Maintenance—NTP status check
In the right view click ‘Synchronize NE’s Clock’ icon.
![Page 52: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/52.jpg)
Internal Only▲
Monthly Maintenance—NTP status check
If successful, RNC TOD time already adjusted. If failed, ask next level for support.
![Page 53: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/53.jpg)
Internal Only▲
Content
Daily Maintenance
Weekly Maintenance
Monthly Maintenance
Quarterly Maintenance
![Page 54: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/54.jpg)
Internal Only▲
Quarterly Maintenance
Quarterly maintenance have one task Cleaning up RNC cabinet dust filter.
![Page 55: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/55.jpg)
Internal Only▲
Chapter/Course Review
Why we need routine maintenance? What we should do?
![Page 56: ZXWR RNC O&M](https://reader033.vdocuments.net/reader033/viewer/2022061202/547cc05bb4af9f674e8b4595/html5/thumbnails/56.jpg)
Internal Only▲