* 6bus x 21zone a/v matrix system * local control p.a. system 500 system c-500, z-500, f-500, v-500,...
TRANSCRIPT
* 6bus x 21zone A/V matrix system* Local control P.A. system
500 SYSTEM500 SYSTEM
C-500, Z-500, F-500, V-500,
A-500, L-500, RM-500
1
Contents
500 System
1. Sales point
2. Target market
3. Products
3-1. C-500 (Main System Controller)
3-2. Z-500 (Zone Output Selector)
3-3. V-500 (Video Matrix Selector)
3-4. F-500 (Fire Sensor Receiver)
3-5. A-500 (Modular Digital Amplifier)
3-6. L-500 (Local Controller)
3-7. RM-500 (Remote Mic. Station)
4. System configuration
5. Block diagram2
500 System 500 System
3
1. Sales point
6 bus multi A/V matrix system
Audio/Video : each 8 input, 6 bus, 21 zone Audio Matrix System
Zone expansion by adding Z-500
6 bus x 10 sets of Z-500 (21 zones) = 210 zones
Priority broadcasting
EM > FIRE > TIMER > PAGING > RM1, 2, 3, 4 > LOCAL > BGM
Multi channels with digital amplification
[ 7+1(spare) channel ] x 3 : total 21+3(spare) channel digital modular
amplifier
Pre AMP : 5 channel MIC input, MIC mix On/Off selection of each bus
Extreme easiness of setting stepwise fire-alarm per each floor.
Extreme easiness of operation and installation by intutional analogue
style user interface
4
Sales point
• Local broadcasting in individual zones (by MIC. & line input of source)
• Local control (bus selection & volume control) at all zones
• No need of additional power supply.* Power is supplied from Z-500 through CAT5 cable.
• Easy installation using CAT5 cable.
Local control system
5
Sales point
• AUDIO and VIDEO synchronized control
• Easy operation with analogue style user interface.
• Monitoring of broadcasting status of set or BGM input
A/V total control system
ON AIR
6
Network control via Ethernet line
ETHERNET
SERVER PCCLIENT
RS-232C
Remote control and monitoring on the PC and network* Power on/off, volume up/down, BGM selection etc.
Sales point
7
Incorporates with existing models
• Source equipment CD-610, CD-611, CD-660, TU-610, PC-9335AD etc.
• Multi-voice file, program timer PV-632, PW-642.
• Telephone paging TP-631.
• Speaker line checker SC-624.
• PD, PB PD-9359, PD-659, PD-658, PB-607 etc.
8
• Education sites : School, college, educational institute, kindergarten, training centre
• Shopping facilities : Department store, retail, shopping mall
• Advertising medium : Customized audio visual commercial broadcasting according
to each target per zone.
• Accommodation : Hotel, hospital, nursing home, resort
• Public building : Office buildings, Restaurants
• Religious facility : Church, mosque
2. Target market2. Target market
•Audio visual broadcasting with flexible control options required applications.
•Voice evacuation system required applications.
•Single and small to medium sized applications
•Remote broadcasting required applications.
•Local self-broadcasting of its’ own zone required applications.
9
- Selective 6 BUS outputs for 8 BGM channel inputs (8x6 Matrix)
- Monitoring function to check signals and bus outputs coming to BGM through monitor
speaker.
- Various function (PP+PE+Matrix. 5 MIC mixing)
- V-500 input control linked with input selection.
- Remote-controlled by PC using RS-232C port and TCP/IP.
- 3 chimes and 2 sirens usable during broadcasting and emergency
- Priority broadcasting (EM>FIRE>TIMER>PAGING>RM1~4>LOCAL>BGM)
- Free voltage (100-240V 50/60Hz)
3-1. C-500 [Main System Controller]
10
Front panelFront panel
1. POWER BUTTON : Red-standby, Green-ON.
2. CHIME BUTTON : Selecting and operating 3 types of chimes.
Convenient to use before or after broadcasting.
3. CHIME LEVEL CONTROL VOLUME
4. BGM SIGNAL DISPLAY LED (SIGNAL LED) : GREEN on input signal of BGM 1~8.
5. MIC SIGNAL DISPLAY LED (SIGNAL AND CLIP LED) : GREEN on input signal of MIC 1~5, RED for CLIP
6. MIC MIX SELECT BUTTON AND INDICATOR
Select button of CHIME, SIREN, MIC inputs and Mixing for BUS 1~6 output.
Red LED on MIC mixing selected.
7. BGM SELECT BUTTON : BGM 1~8 selection for BUS 1~6 output.
8. BUS CHANNEL INDICATOR : Displays selected BGM for BUS 1~6 output. 11
9. BUILT-IN EM MIC : Built-in condenser MIC used during fire and EM broadcasting.
10. SYSTEM OPERATION STATUS DISPLAY LED : Represents system operation and displays broadcasting status
by turning on of each LED according to operation of the selected function.
11. EM MIC LEVEL CONTROL VOLUME :Output control volume of EM broadcasting.
12. EM TALK BUTTON : Press this button and talk in emergency for voice announcement to the zone indicated as EM
broadcasting status at Z-500 during EM broadcasting. Talk close to built-in EM MIC with button pressed during
broadcasting.
13. MONITORING SELECT INDICATOR :Displays a channel to monitor BGM input/BUS output.
14. EM ALL SELECT BUTTON :Select/release all zones connected to Z-500 system as EM broadcasting status.
15. EM TEST BUTTON :Tests the operation status of Fire Automatic Broadcasting, and can test fire contact
broadcasting by selecting the desired zone irrespective of contact of F-500.
16. SYSTEM PRIORITY OPERATION STATUS INDICATOR
17. MIC INPUT LEVEL CONTROL VOLUME :Volume control of MIC 1~5 input level.
18. MIC TONE CONTROL VOLUME : Volume control of TREBLE and BASS tones for MIC 1~5 input.
19. BUS VOLUME INDICATOR .
20. BUS TONE CONTROL VOLUME : Volume control of TREBLE and BASS tones for BUS 1~6 output.
21. BUS OUTPUT LEVEL CONTROL VOLUME : Volume control of output level of MIC 1~6.
22. MONITORING SOURCE SELECT BUTTON
23. SIREN OPERATION BUTTON : Operating flat/wave siren. GREEN LED on selecting siren.
24. MONITORING CHANNEL SELECT BUTTON
25. SIREN SOUND CONTROL VOLUME
26. MONITORING OUTPUT SOUND CONTROL VOLUME
27. SIREN OUTPUT SELECT BUTTON
28. MONITORING SPEAKER 12
Rear panelRear panel
1. MIC INPUT
2. BGM INPUT
3. TIMER INPUT
4. AC POWER
INPUT TERMINAL
5. MAIN POWER
SWITCH
6. DC POWER
INPUT TERMINAL
7. PAGING INPUT
8. VIDEO MATRIX SYSTEM (V-500) COMMUNICATION TERMINAL
9. ZONE SELECTOR (Z-500) TERMINAL
10. DRP RECORD BUTTON
11. REMOTE CONTROL COMMUNICATION TERMINAL
12. FIRE BROADCASTING SOUND SOURCE SELECT SWITCH
13. SERIAL COMMUNICATION TERMINAL
14. FIRE BROADCASTING OUTPUT VOLUME
15. REMOTE CONTACT OUTPUT TERMINAL
16. AUDIO SOUND SOURCE OUTPUT TERMINAL
17. EM MIC TERMINAL
13
A. Electrical specificationsi. INPUT SENSITIVITY
MIC INPUT (BALANCED) 1~5MIC/PHANTOM MIC…………..…………..… -50dB/600ΩLINE……………………………………….…… -10dB/20kΩ
BGM INPUT (STEREO) 1~8 …………….……………………..… -10dB/20 ii. OUTPUT LEVEL
BALANCED OUTPUT ……………………………………….…… OdB ± 3dBiii. TOTAL HARMONIC DISTORTION
MIC INPUT……………………………………………..…………… less than 0.1%BGM INPUT ………………………………………………………… less than 0.05%
iv. SIGNAL TO NOISE RATIOMIC INPUT……………………………………………………..…… better than 60dBBGM INPUT…………………………………………………….…… better than 80dB
B. General feature i. AUDIO INPUT
BGM 1~8 STEREO INPUTMIC 1~5 BALANCED INPUT (LINE/MIC/PHANTOM MIC)INT/EXT EM MIC, TIMER, PAGING LINE INPUTBuilt-in IC memory for CHIME and Fire broadcasting
ii. AUDIO OUTPUTBALANCED OUTPUT for each bus and priority broadcastingBuilt-in monitor speaker for monitoring BGM & BUS
iii. Communication terminalRS-232 with server PC for remote-control RS-422 with Z-500 for monitoring broadcasting status and system control RS-422 with V-500 for video system control
iv. Power sourceAC 100~240V 50/60Hz, DC 24V
Electrical specificationsElectrical specifications
14
- 6 Bus x 21 Zone Output (6 x 21 Matrix)
- Local self-broadcasting using L-500(local controller) up to 21zones.
(L-500x21eas, Bus selection, Volume control, MIC and Line input)
- RM-500 connectable up to 4eas (each 21channel control)
- V-500 video output controllable linked with zone selection.
- Future expandability
- Pre-amp output (zone 1,8,15 for High power amplifier.)
- Selectable EM / Timer broadcasting zone.
- Can be operated incorporated with SC-624 Line checker
3-2. Z-500 [Zone Output 3-2. Z-500 [Zone Output Selector] Selector]
15
1. PAGING BROADCASTING OUTPUT DISPLAY LAMPDetermine using dip switch on the rear side whether PAGING broadcasting is output.Display lamp turns on at the zone where switchis set to ON.
2. ZONE BROADCASTING STATUS INDICATOR
EM/FIRE/TIMER/PAGING/RM/BUS*If all Zone’s status connected with system is ‘-’, display [OFF] on the display window of C-500.
3. EM MIC BROADCASTING OUTPUT DISPLAY LAMPTurns on when pressed EM MIC Broadcasting Selection button of the zone to execute EM broadcasting.
4. TIMER ALARM BROADCASTING OUTPUT DISPLAY LAMPDetermine using dip switch on the rear side whether TIMER (PW-9242, PW-642) broadcasting is output.Display lamp turns on at the zone where switch is set to ON.
EM FIRE TIMER PAGING RM BUS
E F t P R 1~6
Front panelFront panel
16
5. BUS SELECT AND BUS GROUP SELECT BUTTONOne of 6 BUS sound sources can be selected.BUS is selected to the order of 1, 2, 3, 4, 5, 6, 1, 2, 3.....6 whenever pressing the button.
For adjusting 7 channels into same bus, push the very left BUS GROUP BUTTON among 7 channel long time, then the other right 6 channels change together into same bus with the very left channel. (EXAMPLE : If the very left channel was appointed as bus NO.3, right 6 channels are changed into NO.3.)With one more pressing the very left button for a long time, 7 channels are changed into next bus altogether. 6. EM BROADCASTING SELECT AND EM GROUP BROADCASTING SELECT BUTTONSelect the output zone to execute EM (EMERGENCY) broadcasting. If the zone is selected, the lamp turns on to display whether EM broadcasting of the relevant output is done.EM Group button is a button to select EM broadcasting zone by unit of 7-zone. If pressing the very left button, 7 display lamps turn on.
7. ZONE BUS VOLUME CONTROLLERControl bus sound volume.
8. L-500 CONTROL RIGHT BUTTON AND INDICATORAuthority to select BUS of the Local (wall mount) controller connected to each zone and authority to controlBUS sound volume is endowed.
17
1. POWER SWITCH.
2. ZONE 1, 8, 15 INDIVIDUAL OUTPUT TERMINAL
3. Z-500 AUDIO OUTPUT TERMINAL for A-500 Amplifier
4. L-500 CONNECTING TERMINAL
5. DC 24V POWER INPUT TERMINAL
6. RM1~RM4 INPUT TERMINAL AND INPUT VOLUME CONTROLLER
7. VIDEO MATRIX SYSTEM(V-500) COMMUNICATION TERMINAL
8. SPEAKER LINE CHECK COMMUNICATION TERMINAL
9. FIRE SENSOR COMMUNICATION TERMINAL
10. DATA LINK TERMINAL
11. TIME ALARM OUTPUT SELECT SWITCH
12. AUDIO LINK IN (Audio input from C-500 or Link input)
13. PAGING BROADCASTING OUTPUT SELECT SWITCH
14. AUDIO LINK OUT (Link output for expansion of Z-500)
Rear panelRear panel
18
A. Electrical specificationsi. INPUT SENSITIVITY………………………………………………………………… 0dB/20 ii. OUTPUT LEVEL……………………………………………………………………… 0dB ± 2dBiii. TOTAL HARMONIC DISTORTION……………………………………….…… less than 0.1%iv. SIGNAL TO NOISE RATIO…………………………………………………….… better than 80dB
B. General featurei. AUDIO INPUT
BALANCED AUDIO BUSii. AUDIO OUTPUT
Link audio output for audio input Audio terminal output linked in A-500 for audio per each zone ZONE 1, 8, 15 INDIVIDUAL pre-AMP OUTPUT TERMINAL for using high power AMP
iii. Communication terminalRS-422 with C-500 for monitoring broadcasting status and system controlRS-232 with V-500 for video system control RS-232 with F-500 for receiving fire informationRs-232 for checking AMP output signal failureRS-232 communication with RM-500 for REMOTE broadcastingRS-232 communication with L-500 for LOCAL CONTROL
iv. Power sourceDC 24V
Electrical specificationsElectrical specifications
19
- 8 input x 21 zone output (BNC connector)
- Automatic change of channel, bus, zone by C-500/Z-500
operation
- Built-in 4.8” high-definition TFT LCD monitor
- Monitoring input, bus, zone
- Input, output signal : Composite
- NTSC/PAL automatic support
- DC 24V
3-3. V-500 [Video Matrix System]
20
1. POWER DISPLAY LED : Red during operating.
2. DISPLAY POWER BUTTON : Turn on/off LCD power.
3. MENU BUTTON : Set environment of LCD display window.
4. MENU SELECT UP/DOWN
5. SELECT BUTTON : Select LCD environment set up.
(If not for environment setup, operate as video input select button of LCD)
6. VIDEO MONITOR LCD : Checking image of INPUT/BUS,ZONE.
7. INPUT/BUS/ZONE SELECT DISPLAY LED
8. INPUT/BUS/ZONE SELECT BUTTON
9. INPUT/BUS/ZONE DISPLAY PART : Display the selected number on the
monitor.
10. MONITORING CHANNEL SELECT BUTTON
11. DISPLAY SELECT BUTTON : Select the Image to display on Monitor
Front panelFront panel
21
Rear panel
1. DC INPUT TERMINAL
2. INPUT MODE SELECTION SWITCH
(Input : Video signal 1~8, Link Input : Selected Bus
signal 1~6)
3. VIDEO INPUT TERMINAL
4. LINK OUTPUT TERMINAL(BUS Output)
5. POWER SWITCH
6. Z-500 COMMUNICATION TERMINAL
7. C-500 COMMUNICATION TERMINAL
8. 21CH ZONE OUTPUT TERMINAL22
A. Electrical specificationsi. Image standard ………………………………………………… NTSC Composite
Videoii. Link input ………………………………………………..……… 1Vpp (100 IRE)
75Ω/8CHiii. Link output …………………………………………………… 1Vpp (100 IRE)
75Ω/6CHiv. Image output………………………………………..………… 1Vpp (100 IRE)
75Ω/21CH
B. General featurei. LCD MONITOR………………………………………..…………TFT LCD 4.8” WIDE
MONITORii. Monitoring function
8 channel video input monitoring6 channel video bus signal monitoringOutput signal to 21 zones monitoring
iii. Communication terminal RS-422 with C-500 for system control and monitoring
broadcasting status . RS-232 with Z-500 for video output control
iv. Power source DC 24V
Electrical specificationsElectrical specifications
23
- 21 fire information receive channels + expandable 3
channels
- Extremely easy macro setting of fire-alarm zone by just key
button operation
- Demonstration of macro saving status (Macro status
display)
- Displays fire generated floor and EM broadcasting zones in
fire status.
- Using noise-resistant relay sensor contact.
- Incorporated operation with Z-500
- 1 U Size , DC 24V
3-4. F-500 [Fire Sensor Receiver]
24
1. CHANNEL DISPLAYDisplays fire information receive channel (the same as the number of fire input channel on the rear side)
2. CHANNEL UP/DOWN BUTTONChannel movement during Macro setting and setup status checking.
* MACRO : A number in No ‘CHANNEL DISPLAY’ and input terminal to get fire signal in the back side of this unit are corresponded one to one. This is job to select which zone is going to get emergency broadcasting according to input fire signal that is terminal No in the back side of this unit by using button No which is located front side.
3. MACRO ASSIGNMENT BUTTON AND FIRE STATUS INDICATORSets macro and displays fire generation information by using 21 buttons. During generation of fire, It displays the broadcast zone with LED flickering.
Front panel
25
1. DC POWER INPUT TERMINAL (DC TERMINAL)
2. SERIAL TERMINAL (TO Z-500)
3. FIRE RECEIVE PANEL CONTACT INPUT CHANNEL (21-CH)
4. LINK CHANNEL
5. FIRE CONTACT OUTPUT TERMINAL
Rear panelRear panel
26
A. Electrical specificationsi. Fire sensor …………………….………………………… 24 portii. Fire alarm lamp …………………………………….…… 21 unitiii. Fire sensor operation method ………………..…… Relay contact method
B. General specificationsi. Communication terminal
RS-232C with Z-500 for fire detecting signal outputii. Power source
DC 24V
Electrical specificationsElectrical specifications
27
- 8 channel digital modular amp.
(7 +1 Spare channel)
- 30W output per each channel (at 333 ohm )
- Built-in spare amp and self amp status checking.
Automatic shift in failure status.
- Signal, Fault, Spare AMP operation LED display
per
each channel.
- Low-heat expands FAN life-time
- Monitoring per channel (By headphone)
- Operation of DC 24V battery power during
emergency with building AC power gone.
3-5. A-500 [Modular Digital 3-5. A-500 [Modular Digital Amplifier]Amplifier]
28
1. MONITOR OUTPUT JACK : by headphone. Mono signal outout
2. MONITOR VOLUME
3. MONITOR CHANNEL DISPLAY : indicates the selected
channel
4. MONITOR CHANNEL DOWN/UP SWITCH
5. Protective LED : RED On when inner protective circuit
operates due to abnormal operation generates at AMP, to inform
warn of failure status. #1 ~ #7 channel individually operates
depending on failure of the relevant channel. In this case, check of
failure of the AMP or short-circuit of a speaker and then take a
measure to prevent any failure before use.
6. SIGNAL LED DISPLAY : Green On when signal level input is
about more than -30dBv. LED of #1~#7channel operates
depending on signal level.
7. SPARE AMP PROTECTIVE LED : Red On when the spare AMP
channel failures. If there is failure in other channels due to
occurrence of problems in the spare AMP, normal broadcasting is
not done even after automatic shift.
8. SPARE AMP LED
Red On when the spare AMP operates. Red LED turns on to display
that the spare AMP operates after signal is automatically shifted to
spare AMP when the self-temperature detection circuit and the
over-current protection circuit of 7-ch of AMP operate for any
reason,
Front panelFront panel
29
1. AC POWER INPUT TERMINAL
2. POWER SWITCH
3. DC 24V INPUT TERMINAL
4. SIGNAL INPUT CONNECTOR
5. DC FAN
6. SPEAKER TERMINAL
Rear panelRear panel
30
ConnectingConnecting
31
Electrical specifications
A. Electrical specificationi. RATED OUTPUT (at T.H.D 1%)………………………………………………
30W / Channelii. OUTPUT LEVEL ……………………………………………………… 100V / 70V
(Optional)iii. TOTAL HARMONIC DISTORTION………………less than 0.1% (With
AES-17 Filter)iv. SIGNAL TO NOISE RATIO …………………… better than 80dB(With
AES-17 Filter)v. FREQUENCY RESPONSE…………………………………...……………………
80Hz ~ 16kHz
B. General specificationi. AUDIO INPUT
BALANCED AUDIO INPUT 7CHii. AUDIO OUTPUT
High impedence 30W output per each 7 channelDigital amplifier output of low power consumption and
high reliabilityAutomatic output conversion to spare amp channel in
FAULT Various protect function (OCP, OTW, OVP)
iii. Operating temperature-10 ~ +40
iv. Power sourceAC 220~240V 50/60Hz, DC 24V 32
- Bus select at local zone.
- Volume control
- Independent local MIC broadcasting
(Built-in MIC Volume)
- Independent local broadcasting by
source
equipment (CD, MP3…) (3.5 mm Jack)
- No need of additional power supply
(DC 24V supplied from Z-500)
- RS-422 communication (One CAT5 UTP
cable)
3-6. L-500 [Local Controller]3-6. L-500 [Local Controller]
33
Front function1. MIC INPUT VOLUME
Adjusts MIC input volume.
2. MIC INPUT JACK
MIC input terminal. It is recommended to balance input.
3. LINE INPUT JACK
LOCAL BGM input terminal.
4. LINE INPUT VOLUME
Adjusts volume of LOCAL BGM input.
5. BGM DISPLAY
Displays input channel of the MAIN BGM output to the
relevant zone of the Z-500. A DOT(.) display turns on
if control right is endowed to L-500.
6. BGM SELECTBUTTON
Switch to select MAIN BGM input channel.
7. ZONE VOLUME ENCODER
Volume to adjust BGM output volume in the area
where L-500 is installed.
8. BGM LIST
Position to write the name of each BGM source input
so that the user can easily know. 34
Rear function
1. Z-500 DATA CABLE
CONNECTION
TERMINAL
35
3-7. RM-500 [Remote MIC 3-7. RM-500 [Remote MIC Station]Station]
- 21channel control
- Chime (built-in 3 kinds)
- Monitoring with Control volume
- No need of additional power
supply (DC 24V supplied from
Z-500)
- RS-422 communication
(One CAT5 UTP cable)
36
1. LEVEL METER : Output volume in MIC
broadcasting.
2. MIC JACK : Connects to condenser MIC. Dynamic
MIC
can be used.
3. IN-USE LED : If power supply is applied, POEWR
LED
turns on. Displays the using status of 4 RM-500.
4. POWER LED
If power supply is applied, the Power LED turns on.
5. ALL BUTTON : Toggle function as a switch to
select all
broadcasting areas.
6. TALK BUTTON : Broadcasts with the button
pressed, as
a switch to start broadcasting after selecting the
broadcasting area. Release the button to end
broadcasting.
When press button for start broadcasting, LED turn on.
When press button for end broadcasting, LED turn off.
During broadcast, “R” is displayed on the relevant
display of both Z-500 and L-500.
7. ZONE SELECTION BUTTON
Turn on if pressing the switch to select the area to
broadcast and off if pressing it again.
Front functionFront function
37
Rear function
1. CONNECTION TERMINAL to Z-500
2. OUTPUT VOLUME
(Sound volume of MIC and chime
Broadcasting)
3. MONITOR SPEAKER VOLUME
4. CHIME MODE SELECT SWITCH38
Classroom
VCR
DVD
TV
CD-610
CD-660
TU-610
PC-9335
TP-631
PV-632
PW-642
PD-659
PB-607
Broadcasting zone
4. System 4. System configuration 1configuration 1
39
SystemSystemconfiguratioconfiguration 2n 2
PD-9359
40
5. Block diagram5. Block diagram
D-AMP(A-500)
D-AMP(A-500)
7 7 7
7 7 7
6
8
4
21
21
FIRE SENSOR
RECEIVER
(F-500)
VIDEO MATRIX
SYSTEM
(V-500)
Expansion #1 Expansion #2
PRE OUT
REMOTE
MIC #4
(RM-500)
LOCAL
CONTROLLER
#1
(LM-500)
LOCAL
CONTROLLER
#21
(LM-500)
VIDEO*6
~ ~
VIDEO MATRIX
SYSTEM
(V-500)
VIDEO*6~ ~
ZONE OUTPUT SELECTOR
(Z-500)
21
VIDEO 21 ZONE OUT
VIDEO 21 ZONE OUT
Fire receiving panel
※Examples
AudioControl/contact signalAudio & dataVideo
21+3
INTER
NET VIDEO
INPUT X 8
30
W X
7
REMOTE
MIC #1
(RM-500)
30
W X
7
30
W X
7
3
PAGING
TIMER
MIC #1
MAIN CONTROLLER SYSTEM
(C-500)
AUDIO INPUT * 8
MIC #5
PC
D-AMP(A-500)
D-AMP(A-500)
D-AMP(A-500)
7 7 7
7 7 7
4
21
FIRE SENSOR
RECEIVER
(F-500)
PRE OUT
LOCAL
CONTROLLER
#1
(L-500)
LOCAL
CONTROLLER
#21
(L-500)
ZONE OUTPUT SELECTOR
(Z-500)
Fire receiving panel
21+3
30
W X
7
REMOTE
MIC #1
(RM-500)
30
W X
7
30
W X
7
3
D-AMP(A-500)
REMOTE
MIC #4
(RM-500)
AU
DIO
*1 &
RS
-422
( )
AU
DIO
*1 &
RS
-422
( )
AU
DIO
*7
CO
NT
AC
T (
)
AU
DIO
*7
CO
NT
AC
T (
)
AU
DIO
*7
CO
NT
AC
T (
)
AU
DIO
*7
CO
NT
AC
T (
)
AU
DIO
*7
CO
NT
AC
T (
)
AU
DIO
*7
CO
NT
AC
T (
)
AU
DIO
*1 &
RS
-422
( )
AU
DIO
*1 &
RS
-422
( )
AUDIO*1 & RS-422 ( )
1
AUDIO*1 & RS-422 ( )
RS-422
RS
-23
2
RS
-23
2
AU
DIO
R
S-4
22
( )
RS-232
RS
-23
2
41