© abb - page 1 iec 61850 - proven technology and innovation iec 61850 uca 2.0 iec 60870...

14
ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process Bus Comm Architectur e Configurati on Language

Upload: martina-richards

Post on 22-Dec-2015

273 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

1

IEC 61850 - proven technology and innovation

IEC 61850UCA 2.0 IEC 60870

Communication conceptsData Models

Ethernet Technology

Process Bus

Comm Architecture

Configuration Language

Page 2: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

2

Overview on activities

OCIS, 1998 - 2000: Communication between Station and Bay Level

GOOSE demo, 2001: Transmission of trip - signals over serial communication

IEC 61850-9-1 interoperability, 2001 - 2002: Communication between CT/VT’s and protection relays

IEC 61850-8-1 interoperability, 2002 - 2003: First installations with interoperability between ABB, ALSTOM and SIEMENS

Page 3: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

3

The OCIS - Project

Project goals Assist the standardization process to reach one

world-wide standard IEC 61850 Assist the harmonization process between IEC

61850 and UCA.2 Test and compare original IEC 61850 and

UCA.2 drafts with respect to feasibility, applicability and efficiency

Test the independence of IEC 61850 from the communication stack (Verify the basic communication architecture)

Project duration The project started in 1998 and terminated with

a conference in 2000

Page 4: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

4

StationsbusMMS/EthernetIEC 61850-8-1

StationsbusFMS/Profibus

Test setupThe OCIS

project

Page 5: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

5

Summary of results

The communication concepts as defined in IEC 61850 drafts fulfill the requirements of substation communication

The object model of UCA needs extensions to be applicable by the European market

Ethernet is suitable as station bus IEC 61850 based applications are independent from the

communication stack and therefore future proof IEC 61850 provides interoperability between devices

from multiple vendors

The OCIS project

Page 6: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

6

The GOOSE Demo

GOOSE: Generic Object Oriented System Event

Project goals Verify the concepts of the IEC enhanced

GOOSE Verify the basic concepts of the substation

configuration language Demonstrate interoperability and

configurability between multiple vendors

Project duration Project start January 2001 Demonstration at Utility Initiative Meeting in

Vancouver, May 24, 2001

Page 7: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

7

Analog inputs

Ethernet Network

Switchgear Sim

Relay

Test Equipment

Network Analyzer

Basic Demo setupThe GOOSE

demo

Relay

Page 8: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

11

Goose Message: PositionsGoose Message: Positions

SIEMENS Relay ABB Relay

ABB PASS Simulation

OMICRON Test Equipment

Ethernet Network

Analog inputs

1. Simulated fault

2. Trip generated

4. Reclose command

Goose Message: RecloseGoose Message: Reclose

3. New position

Goose Message: PositionsGoose Message: Positions

Goose Message: TripGoose Message: Trip

5. New position

Case 1: Trip and auto-reclosingThe GOOSE

demo

Page 9: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

12

Summary of results

The GOOSE concept is suitable to transmit trip signals over a serial communication

The use of the configuration language to configure the GOOSE message facilitates interoperability between devices from multiple vendors

With the demonstration at the UCA user group meeting, an important milestone towards a global standard was reached

The GOOSE demo

Page 10: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

13

IEC 61850-9-1 interoperability

Project goals demonstrate interoperability between non

conventional sensors, protection relays and revenue meters with IEC 61850-9-1

develop first prototypes of devices supporting IEC 61850-9-1

Project duration Cooperation of ABB and SIEMENS to support

IEC 61850-9-1 announced at CIGRE 2000 meeting

Interoperability tests at KEMA Nov 2001 Demonstration at Utility Initiative Meeting in Dana

Point, January 10, 2002 Demonstration at Hannover Fair, April 2002

Page 11: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

14

Protection relays

Merging units

Point-to-point link according to

IEC 61850-9-1

SIE

ME

NS

SIE

ME

NS

to instrumental transformers

Revenue meter

IEC 61850-9-1 interoperability Basic test setup

Revenue meter

SIE

ME

NS

SIE

ME

NS

Page 12: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

16

From point-to-point link to process bus

REB500ABB ABB Network Partner

PIS

A

PIS

A

PIS

A

PIS

A

A

PIS

AA

PIS

AB

MergingUnit

MergingUnit

Other Bays

Protection Unit

I

REB500ABB ABB Network Partner

PIS

A

PS

A

PIS

A

PIS

A

A

PIS

AA

PIS

AB

MergingUnit

MergingUnit

MergingUnit

Other Bays Other Bays

Protection Unit

EthernetSwitch

IEC 61850-9-1 interoperability

Page 13: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

17

61850-9-1 Ethernet sample rates:1000S/s, 4000S/s

Proprietary interface

sample rate:8000S/s

Omicron Test Set

3 U3 I

Relay

Merging Unit

Switch / Media Converter

Sensor Simulator

Phs CPhs BPhs A

Switch / Media Converter

RelayMeter

Merging Unit

Detailed test setupIEC 61850-9-1

interoperability

Page 14: © ABB - Page 1 IEC 61850 - proven technology and innovation IEC 61850 UCA 2.0 IEC 60870 Communication concepts Data Models Ethernet Technology Process

© A

BB

- P

age

18

Summary of results

The point - to - point link connecting non conventional instrumental transformers according to IEC 61850-9-1 is ready to be used and will be supported in future by ABB and SIEMENS

Communication links supporting IEC 61850-9-1 may be connected with an Ethernet switch implementing a first step of a process bus solution.

IEC 61850-9-1 interoperability