- instrumentation cables
TRANSCRIPT
For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA
FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]
This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA
Grey, Black or Light blueColors
Fire retardant thermoplastic compound R16 PVC-based H.R. and O.R. suitable for CPR (R16 quality)
MaterialSHEATH
70 °CMax operating temperature
160 °CMax short circuit temperature
10 x Diam.Min. bending radiusMechanical and Installation:
Electrical:
>= 100 MOhm x kmInsulation resistance
3000 V a.c. x 10 minDielectric test cond/cond
450/750 VVoltage rating
CHARACTERISTICS
Cores are twisted in pair with optimal lay lengthTypePRIMARY CABLING
Al/polyester tap, Al in continuos contact with stranded tinned copper cl.2 MaterialTOTAL SCREEN
Pairs are cabled together with optimal lay lengthTypeTOTAL CABLING
On RequestColors
Fire retardant thermoplastic compound S17 PVC-based (S17 quality)MaterialINSULATION
Flexible annealed bare copper cl.5MaterialCONDUCTOR
CABLE CONSTRUCTION AND SPECIFICATIONS
IDENTIFICATION AND REACTION TO FIRE
FS17XOHR16 - 450/750 V - PAIR Cca-s3,d1,a3
DRAWING IS ONLY ILLUSTRATIVE
CPR cable - INSTRUMENTATION CABLES
FORELIND®
Special Electrical Cables
For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA
FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]
This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA
8000
8001
8004
8006
8008
8018
8019
8022
8024
8026
8027
8028
8031
8033
8035
78
157
288
500
903
104
217
415
758
1382
145
319630
1158
2151
7,33
10,53
14,26
18,71
25,67
8,19
11,94
16,33
21,79
29,96
8,53
14,3419,74
26,45
36,76
-
-
-
-
-
-
--
-
-
-
--
--
-
26
26
26
26
26
13,3
13,3
13,3
13,3
13,3
7,98
7,987,98
7,98
7,98
FS17XOHR16 - 450/750 V - 1X2x0,75 mm2
FS17XOHR16 - 450/750 V - 2X2x0,75 mm2
FS17XOHR16 - 450/750 V - 6X2x0,75 mm2
FS17XOHR16 - 450/750 V - 12X2x0,75 mm2
FS17XOHR16 - 450/750 V - 24X2x0,75 mm2
FS17XOHR16 - 450/750 V - 1X2x1,5 mm2
FS17XOHR16 - 450/750 V - 2X2x1,5 mm2
FS17XOHR16 - 450/750 V - 6X2x1,5 mm2
FS17XOHR16 - 450/750 V - 12X2x1,5 mm2
FS17XOHR16 - 450/750 V - 24X2x1,5 mm2
FS17XOHR16 - 450/750 V - 1X2x2,5 mm2
FS17XOHR16 - 450/750 V - 2X2x2,5 mm2FS17XOHR16 - 450/750 V - 6X2x2,5 mm2
FS17XOHR16 - 450/750 V - 12X2x2,5 mm2
FS17XOHR16 - 450/750 V - 24X2x2,5 mm2
Ohm/km mm mm kg/km
Max conductorresistance at 20°C
Nom. Underarmour Ø
Nom. Outer Ø Nom. Weight P/NIDENTIFICATION ( * )
CEI 20-11/0-1;V1 - -Insulating, sheathing and covering materials for low-voltage energy cables (CPR)
CEI 46-143 - EN 50288-7(CEI EN 50288-7)
Multi-element metallic cables used in analogue and digital communication and control. Part 7: Sectional specification for instrumentation and control cables (where applicable)
CEI 20-29 IEC 60228 EN 60228(CEI EN 60228)
Conductors of insulated cables
STANDARDS OR SPECIFICATIONS CONSTRUCTION
CEI 20-35/1-2 IEC 60332-1-2 EN 60332-1-2(CEI EN 60332-1-2)
Test on electric and optical fibre under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
CEI 20-108 - EN 50399(CEI EN 50399)
Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test - Test apparatus, procedures, results
STANDARDS OR SPECIFICATIONS TEST
DATASHEET
PAGE 02CPR cable - INSTRUMENTATION CABLES
FORELIND®
Special Electrical Cables
( * ) Any other identification on request. Please contact our technical department
Via Europa, 6 - 24055 Cologno al Serio (BG - ITALY)Phone + 39 035 899191 - Fax + 39 035 4819224www.forelind.com E-mail: [email protected]
FOR.EL.IND S.p.A.
Special Electrical Cables
®FORELIND