Dip-FreeTM
URL :http://www.dipfree.com 05059930267075
&
(Voltage Sag, Dip)
10% ~ -90%
0.5 ~ 30 Cycle
(Interruption, Outage)
90% 1
&
, , , , ,
,
,
,
: 17, 19
: 39 2
47, 49
) S (Power Vaccine Line)
: -10% ~ -100% 1,000msec
Components :
Solutions
Dip-FreeTM NontripDip-Free : 250VA ~ 5,000VA
Nontrip (NT-CMxx) : M/C
Nontrip (NT-CP2) : SMPS
DSP : SMPS
DSP
0505993 0267075
: Dip-Free
: , 1
S, CE, T V
Dip Counter
Dip (0.1 ~ 5.0sec)
Dip (AC170~190V, AC85~99V)
Dip (AC200/210/220/230V, AC100/110/120V)
Off-line : Stand by.
: , GAS
Power Capacitor : 10
: 1msec
: Off-Line
: UPS CVT 2~3
Oversize ,
, : Step-Up
Dip (Option : )
Dip-Free
0505993
Dip-Free
Dip-Free 1
Dip-Free 2
Dip-Free 3
Dip-Free 2 ()
Dip-Free 1 ()
Dip-Free 4 ()
Dip-Free 3 ()
Dip-Free : AC230V
Dip-Free : AC120V
Dip-Free
Manual Bypass Switch
1.(Vrms), (Arms).
2. (pf). ( 0.8 )
3. (VA) = (Vrms) x (Arms) x (1.5)
4. Dip-Free
Ex) 1) = AC217Vrms , = 1.6Arms
2) (pf) = 0.7
3) = (217 x 1.6) x (1.5) = 520.8
4) AC230V Series Dip-Free DVC-0600-N2
5) DVCBPSW-25 (25A )
Line Out
(Supply)
Line in
1 2 2 3
(Load)
DVCBPSW-25
21 2 3
21 2 3
Dip-FreeTM
Dip-Free TerminalTM
BY-PASS
NTC RK5394
AC IN AC OUT
125
19.2
19.2
142
110
371. :
2. : ,
3. : 25A, 40A
4. : DVCBPSW-25, DVCBPSW-40(DVC-5000-N2, DVC-2500-N1 )
M/C, Relay : Nontrip
Nontrip ,
( Voltage-Sag, Dip) Magnetic
Contactor Trip
.
.
SMU (Super Magnetic Unit)
AC AC/DC M/C
. M/C
,
Socket Type
1
.
( 0267075)
S CE 0267075
Nontrip
Nontrip
Nontrip
PW(Green) :
CH(Red) : Dip Control
OP(Yellow) : Dip
RESET : Counter Voltage Dip 0 Reset .
TEST : Unit . Magnet Contactor Coil
Test .()
COUNTER : Voltage Dip 0~9,
0
Voltage Dip , Unit
(1) ,
.
.
Nontrip
Nontrip
1) Nontrip .
2) Nontrip SOCKET .
3) SOCKET Cable .
4) OFF Nontrip SOCKET
5) .
6) OFF & ON Nontrip .
10mm
NT-CMxx 2 (AC/DC M/C)
NT-CMxx 1 (AC M/C)
NT-CP2 2 ()
NT-CP2 1 ()
DSP
SMPS : DSP
DSP SMPS(Switching Module Power Supply)
Trip
, (Voltage-Sag, Dip)
SMPS Trip .
SMPS(Switching Module Power Supply)
19inch Rack Type
1
CE, TV
: CP3000 / CP1800
: 3,000VA / 1,800VA
: 1 200Vac ~ 230Vac, 50/60Hz
: 200Vdc ~ 230Vdc
: 185Vac 3V
: 1,000msec
: SMPS
CP3000
CP1800
DSP
DSP
PW(Green) :
CH(Red) : Dip Control
OP(Yellow) : Dip
RESET : Counter Voltage Dip 0 Reset .
TEST : Unit .()
COUNTER : Voltage Dip 0~9,
0
Voltage Dip , Unit
(1) ,
.
.
H N G + - G
INPUT OUTPUT
HNG
HNG
220VacInput
220VdcOutput
DSP
DSP
1.DSP (200Vac ~ 230Vac Only)
2.DSP
3. DSP Rack S/W Off
4. DSP On
5.
6. Off On :
: mm
: .
- CP3000 (3KVA) : 4U
- CP1800 (1.8KVA) : 2U
VDS
Voltage Dip Simulator : VDS
VDS (Voltage Dip, Sag)
.
100%
LCD
: VDS-2000 / VDS-3000
: 2,000VA / 3,000VA
: 1 200Vac ~ 230Vac, 50/60Hz
: 1 0Vac ~ 230Vac, 50/60Hz
: 0 ~ 360 (10)
: 1msec ~ 9,999msec
: 1 ~ 100
: