02 baumgartner
TRANSCRIPT
![Page 1: 02 baumgartner](https://reader035.vdocuments.net/reader035/viewer/2022062302/5877f7901a28ab91178b5019/html5/thumbnails/1.jpg)
FruitBreedomics – Technical SessionSampling procedures: Hands on experience and practical detailsI. Baumgartner (Agroscope)
San Giuseppe di Comacchio (Italy), June 19th 2015
![Page 2: 02 baumgartner](https://reader035.vdocuments.net/reader035/viewer/2022062302/5877f7901a28ab91178b5019/html5/thumbnails/2.jpg)
Overview
• 96-well format – why?• Coding systems for plant identification• Demonstration on steps of leave sampling
procedure
![Page 3: 02 baumgartner](https://reader035.vdocuments.net/reader035/viewer/2022062302/5877f7901a28ab91178b5019/html5/thumbnails/3.jpg)
Companies process samples in a 96-well format
![Page 4: 02 baumgartner](https://reader035.vdocuments.net/reader035/viewer/2022062302/5877f7901a28ab91178b5019/html5/thumbnails/4.jpg)
Coding systems for individual plant identification
Individual labeling of seedlings• combination number• seedling number• (parents, resistances)
Positional coding system • 4 plates of 6 x 4 pots represent
96-well plate• No individual seedling labeling
![Page 5: 02 baumgartner](https://reader035.vdocuments.net/reader035/viewer/2022062302/5877f7901a28ab91178b5019/html5/thumbnails/5.jpg)
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
1 - I 1 - II
1 - III 1 - IV
Positional coding system I
Plants in 4 plates of 6 x 4 pots Leave samples in 96-well plate
![Page 6: 02 baumgartner](https://reader035.vdocuments.net/reader035/viewer/2022062302/5877f7901a28ab91178b5019/html5/thumbnails/6.jpg)
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
1 - I 1 - II
1 - III 1 - IV
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
2 - I 2 - II
2 - III 2 - IV
Positional coding system II
![Page 7: 02 baumgartner](https://reader035.vdocuments.net/reader035/viewer/2022062302/5877f7901a28ab91178b5019/html5/thumbnails/7.jpg)
LGC leaf sampling I
![Page 8: 02 baumgartner](https://reader035.vdocuments.net/reader035/viewer/2022062302/5877f7901a28ab91178b5019/html5/thumbnails/8.jpg)
LGC leaf sampling II
![Page 9: 02 baumgartner](https://reader035.vdocuments.net/reader035/viewer/2022062302/5877f7901a28ab91178b5019/html5/thumbnails/9.jpg)
LGC leaf sampling III
![Page 10: 02 baumgartner](https://reader035.vdocuments.net/reader035/viewer/2022062302/5877f7901a28ab91178b5019/html5/thumbnails/10.jpg)
![Page 11: 02 baumgartner](https://reader035.vdocuments.net/reader035/viewer/2022062302/5877f7901a28ab91178b5019/html5/thumbnails/11.jpg)
• Plates of 6 x 4 pots allowed plant identification without labelling
• Coding system not easy for processing of plants
• Missing plants were replaced by living plants to fill up gaps in the plates (cost), laborious
• Puncturing the leaves and expedition of the plates was efficient
• The whole procedure was more time-consuming than expected
• Costs are relatively low, DNA extraction is the most expensive, data point to low price
• Close interaction with the company (LGC genomics) was required and successful
KASP - SNP Genotyping
MAB experiences
![Page 12: 02 baumgartner](https://reader035.vdocuments.net/reader035/viewer/2022062302/5877f7901a28ab91178b5019/html5/thumbnails/12.jpg)
Thank you for your attention
powdery mildew
Agroscope good food, healthy environment