02a tos panels - · pdf filea variety of optional element types are available acoustic...

17
panels PANEL OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 POWER PANEL BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 MODULAR POWER PANEL BASICS . . . . . . . . . . . . . . . . . . . . . . . 39 SUPER PANEL BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 PLANNING WITH PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 PLANNING WITH ADD-ON LAY-IN . . . . . . . . . . . . . . . . . . . . . . 43 ELEMENT/PANEL COMPATIBILITY CHART . . . . . . . . . . . . . . . . . 44 PRIVACY SCREEN BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 PLANNING WITH PRIVACY SCREENS . . . . . . . . . . . . . . . . . . . . 47 BRIDGE BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 PLANNING WITH BRIDGES . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 DOOR PANEL BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 PANEL T BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 t/o/s application guide – April 30, 2018

Upload: phamthuan

Post on 16-Mar-2018

221 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

PANEL OVERV IEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 7

POWER PANEL BAS ICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 8

MODULAR POWER PANEL BAS ICS . . . . . . . . . . . . . . . . . . . . . . . 3 9

SUPER PANEL BAS ICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 0

PLANNING WITH PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2

PLANNING WITH ADD-ON LAY- IN . . . . . . . . . . . . . . . . . . . . . . 4 3

ELEMENT/PANEL COMPAT IB IL ITY CHART . . . . . . . . . . . . . . . . . 4 4

PR IVACY SCREEN BAS ICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 6

PLANNING WITH PR IVACY SCREENS . . . . . . . . . . . . . . . . . . . . 4 7

BR IDGE BAS ICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 8

PLANNING WITH BR IDGES . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 9

DOOR PANEL BAS ICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 0

PANEL T BAS ICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1

t/o/s application guide – April 30, 2018

Page 2: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed
Page 3: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

A variety of optional element types areavailable

Acoustic Elements (PAA) are thedefault elements for both inner andouter sides of the panels

An enclosed raceway is included onall panels at to carry power andcommunication cables: the racewayprovides a conduit that allows forinstallation of outlets, enabling accessat worksurface height

Power and communications access isprovided through the access door,access cover or facemounted

Pass Through Holes are punchedinto the frame structure to enable thepassage of communication cables. Upto 60 Category 5 communicationcables can be accommodated in eachhole power/communication element

panels

t/o/s application guide – April 30, 2018

panel overview

Panel frames are constructed ofwelded steel with an integratedbaseboard

Levelers are included and have anadjustment range of 2 1/2" to allowfor consistency of Panel height

Panels are the basic building block for which all other system components are dependent to create a comprehensiveenvironment. The following outlines the basic features of all T/O/S panels.

T/O/S offers three panel types – Power Panel (PE), Modular Power Panel (PM) and Super Panel (PX)

Page 4: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

t/o/s application guide – April 30, 2018

power panel basics

The Power Panel (PE) is an economical single-frame panel, non-segmented above 36", which supports a limited portion ofthe Element Program and provides both power pass-through and power access capabilities.

• When adding an Add-On Module (PX, PXL15. PXD) to a 36" or 42" high panel with existing wiring, a special bracket isrequired. Please contact your Teknion Customer Service Representative for more information

• Overhead storage must be hung on-module using on-module brackets on any panel or 15" add- on panel

Add-On Modules (PX, PXL15, PXD)• Can be applied to the top of any Panel toincrease height (42" high panels require PXD)

• Multiple 15" add- on modules can be appliedon a panel to increase height

• Only one 6" add-on module can used on apanel and must be at the top of each Panel. 6"add- on modules cannot be used to supportoverhead storage

•With Lay-In (PXL15 or PXD-2) includes a lay-in channel for routing communication cables

• Must be specified at Level 2 or higher

Ceiling feed entryvia Power Pole

36" height:belowworksurfaceprivacy

72" height:full standingprivacy

66" height:partialstandingprivacy

60" height:full seatedprivacy andpartialstandingprivacy

51" height:full seatedprivacy

42" height:partialseatedprivacy

81" height:full standingprivacy

18" & 60"

Over Panel (PO)• Is a custom Glass Element within a frameavailable in a Clear or Frosted finish

• Must be specified at the top level and canextend to the ceiling

Alternative to Add-On Modules:

15" - 45"h

36"h

18" - 60"w

36" - 81"h

Without lay-in With lay-in

Finishes• Frame and metal top trim areavailable in Foundation and Micacolors

• Flintwood top trim is available inFlintwood stains

• The frame can be ordered as a bareframe with all elements and trimordered separately or as a completepanel when a panel matrix is used

• Is not segmented above 36" height

• Cannot be decreased from originalheight specified however, can beincreased

• Bare frames do not include top trims

• *Lay-in option includes a lay-inchannel at the top of the panel forrouting communications cables

* (Not compatible with PAG, PTS orPTN Elements)

There are two knockouts in eachraceway for outlets, enabling access topower at worksurface height

The raceway is an enclosed area usedto carry power and communicationscabling

A base feed knockout is included perside of the Panel

Levelers offer a 2 1/2" adjustmentrange

6" & 15"

18" - 60" 18" - 60"

15"

Page 5: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

t/o/s application guide – April 30, 2018

modular power panel basics

The Modular Power Panel (PM) is a single-frame Panel, segmented above 36" which supports the full Element Programand provides both power pass-through and power access capabilities.

• Includes a horizontal rail at every 15" increment above 36"• When adding an Add-On Module (PX, PXL15) to a 36" or 42" high panel with existing wiring, a special bracket is required.Please contact your Teknion Customer Service Representative for more information

• Overhead storage can be hung on- or off-module on any panel or 15" add- on module

15"h

36"h

15"h

15"h

18" - 60"w

36" - 81"h

66" height:partialstandingprivacy

51" height:full seatedprivacy

42" height:partial seatedprivacy

36" height:belowworksurfaceprivacy

81" height:full standingprivacy

Add-On Modules (PX, PXL15, PXD)• Can be applied to the top of any Panel toincrease height (42" high panels require PXD)

• Multiple 15" add- on modules can be appliedon a panel to increase height

• Only one 6" add-on module can used on apanel and must be at the top of each Panel. 6"add- on modules cannot be used to supportoverhead storage

•With Lay-In (PXL15 or PXD-2) includes a lay-in channel for routing communication cables

• Must be specified at Level 2 or higher

Ceiling feed entryvia Power Pole

6" & 15"

18" - 60"

18" - 60"

18" - 60"

Over Panel (PO)• Is a custom Glass Element within a frameavailable in a Clear or Frosted finish

• Must be specified at the top level and canextend to the ceiling

Alternative to Add-On Modules:

15"

Without lay-in With lay-in

Finishes• Frame and metal top trim areavailable in Foundation and Micacolors

• Flintwood top trim is available inFlintwood stains

• The frame can be ordered as a bareframe with all elements and trimordered separately or as a completepanel when a panel matrix is used

• Is segmented above 36" height

• Cannot be decreased from originalheight specified however, can beincreased

• Bare frames do not include toptrims

• *Lay-in option includes a lay-inchannel at the top of the panel forrouting communications cables

* (Not compatible with PAG, PTS orPTN Elements)

There are two knockouts in eachraceway for outlets

The raceway is an enclosed area atused to carry power andcommunications cabling, enablingaccess at worksurface height

A base feed knockout is included perside of the Panel

Levelers offer a 2 1/2" adjustmentrange

Page 6: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

t/o/s application guide – April 30, 2018

super panel basics

• Includes a horizontal rail at every 15" increment above 36"• When adding an Add-On Module (PX, PXL15) to a 36" or 42" high panel with existing wiring, a special bracket is required.Please contact your Teknion Customer Service Representative for more information

• Overhead storage can be hung on- or off-module on any panel or 15" add-on panel

The Super Panel (PX) allows maximum panel-height flexibility. It is made up of individual 15" segments from 36" upwhich supports the full Element Program and provides both power pass-through and power access capabilities.

15"h

36"h

15"h

15"h

18" - 60"w

36" - 81"h

Add-On Modules (PX, PXL15)• Can be applied to the top of any Panel toincrease height

• Multiple 15" add- on modules can be appliedon a panel to increase height

• Only one 6" add- on module can be used on apanel and must be at the top of each Panel. 6"add- on modules cannot be used to supportoverhead storage

•With Lay-In (PXL15) includes a lay-in channelfor routing communication cables

• Must be specified at Level 2 or higher

Ceiling feed entryvia Power Pole

18" - 60"

Over Panel (PO)• Is a custom Glass Element within a frameavailable in a Clear or Frosted finish

• Must be specified at the top level and canextend to the ceiling

Alternative to Add-On Modules:

Without lay-in With lay-in

Finishes• Frame and metal top trim areavailable in Foundation and Micacolors

• Flintwood top trim is available inFlintwood stains

• The frame can be ordered as a bareframe with all elements and trimordered separately or as a completepanel when a panel matrix is used

• Is segmented above 36" height

• Can be decreased in height down to36"

• Bare frames do not include top trims

• *Lay-in option includes a lay-inchannel at the top of the panel forrouting communications cables

* (Not compatible with PAG, PTS orPTN Elements)

There are two knockouts in eachraceway for outlets enabling access toworksurface cabling

The raceway is an enclosed area at36" high used to carry power andcommunications cabling

A base feed knockout is included perside of the Panel

Levelers offer a 2 1/2" adjustment range

66" height:partialstandingprivacy

51" height:full seatedprivacy

42" height:partial seatedprivacy

36" height:belowworksurfaceprivacy

81" height:full standingprivacy

6" & 15"

18" - 60" 18" - 60"

15"

Page 7: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed
Page 8: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

t/o/s application guide – April 30, 2018

planning with panels

The following should be taken into consideration when planning with T/O/S panels.

Access Door (AD)

raceways

The raceway provides a conduit thatallows for installation of outlets atspecified locations within a panelthereby enabling access through AccessDoors at worksurface height

• Knockouts in raceways are spacescreated for outlets

• There are two knockouts in eachraceway

off-module planning• Larger width Panels can be used off-module to lower costs andsimplify inventory control

• Off-module connectors are required for mounting surfaces

• Off-module jumpers are required to route power through off-module connectors

3 3/4" 3 3/4" 1/8"

Two-Way

standard corners

Three or Four-Way Straight

panel creep• Panel creep is the incremental dimensional increase created by straight panel runs and panel connections

• Panel creep should be accommodated in the planning process to ensure successful installations

A raceway is an enclosed area within a panel used to carry power and communications cables

Page 9: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

t/o/s application guide – April 30, 2018

planning with the add-on lay-in

• Provides increased communications cabling capacity when added to top of any Panel• Accepts a limited portion of the T/O/S Element Program• Elements and top trim are specified separately as part of the Panel Matrix Order Form• Electrics cannot be run in lay-in trough

The Add-On Module – Lay-In provides increased integrated communication cable carrying capacity. It can be applied tothe top of any T/O/S Panel type.

integrated lay-in channel• Has an integrated 1 1/4" with a 3" high lay-in channel for routingcommunication cables

• The intended capacity of this trough is 60 Cat 5 cables

The cable capacity of the Add-On Module Lay-In will be reduced at allcorners

cable management• Wing Panels maintain cable routing capability when located on-module

• Changes in wing Panel height may reduce the cable capacity of the Add-OnModule Lay-In

add-on module lay-in along spineThe primary application of the Add-On Module – Lay-In is along the spine ofsame height T/O/S Panels. In this use, a continuous cable trough is created

CommunicationCables

Integrated Lay-InChannel

On-Module Junction

Panel Spine

Change in Height

On-ModuleWing Panels

Three-Way CornerConnection

Add-On Module – Lay-In Along Spine

Three-Way CornerConnection

Wing Panels

Panel Spine

Page 10: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

element/panel compatibility chart

t/o/s application guide – April 30, 2018

Please use the chart below to determine which elements can be used at different panel frame levels.

PE = Power Panel | PM = Modular Power Panel | PX = Super Power Panel

Element Height

PAA PAASPAABPAASB

PTAPTAS

ADADSCAPCAPCS

ADHPADE/P

PTSPTDPAGS/DPTN

PAEPHF

PAME/PPAWMPAWS

PVE

36"

PE 26 n/a 26, 32 n/a 06 06 n/a n/a n/a 26 n/a 26

PM 26, 36 n/a 26, 32 n/a 06 06 n/a n/a n/a 26 n/a 26

PX 26 n/a 26, 32 n/a 06 06 n/a n/a n/a 26 n/a 26

42" PE 06, 26 06 26, 32 06 06 06 n/a n/a 06 26 n/a 06, 26

51"

PE 15, 26 15 26, 32 15 06 06 15 15 15 15, 26 15 15, 26

PE_2 15, 26 15 26, 32 15 06 06 n/a n/a 15 15, 26 15 15, 26

PM 15, 26 15 26, 32 15 06 06 15 15 15 15, 26 15 15, 26

PM_2 15, 26 15 26, 32 15 06 06 n/a n/a 15 15, 26 15 15, 26

PX 15, 26 15 26, 32 15 06 06 15 15 15 15, 26 15 15, 26

60" PE 24, 26 24 26, 32 24 06 06 n/a n/a n/a 26 n/a 26

66"

PE 26, 30 30 26, 32 30 06 06 n/a n/a n/a 26 30 26

PM 15, 26 15 26, 32 15 06 06 15 15 15 15, 26 15, 30 15, 26

PM_2 15, 26 15 26, 32 15 06 06 n/a n/a 15 15, 26 15, 30 15, 26

PX 15, 26 15 26, 32 15 06 06 15 15 15 15, 26 15, 30 15, 26

72" PE 26, 30 36 26, 32 36 06 06 n/a n/a n/a 26 n/a 26

Panel Height

Frame Style

Page 11: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

t/o/s application guide – April 30, 2018

element/panel compatibility chart (continued)

Please use the chart below to determine which elements can be used with Panel Add-Ons.

Element Height

PAA PAASPAABPAASB

PTAPTAS

ADADSCAPCAPCS

ADHPADE/P

PTSPTDPAGS/DPTN

PAEPHF

PAME/PPAWMPAWS

PVE

81"

PE 26, 45 45 26, 32 45 06 06 n/a n/a n/a 26 n/a 26

PM 15, 26 15 26, 32 15 06 06 15 15 15 15, 26 15, 30 15, 26

PM_2 15, 26 15 26, 32 15 06 06 n/a n/a 15 15, 26 15, 30 15, 26

PX 15, 26 15 26, 32 15 06 06 15 15 15 15, 26 15, 30 15, 26

Panel Height

Frame Style

Element Height

PAAPAAS

PAABPAASB

PTAPTAS

ADADSCAPCAPCS

ADHPADE/P

PTSPTDPTNPHF

PTDPAGS/DPTN

PAE PAME/PPAWMPAWS

PVE

06"

PX 06 n/a 06 n/a n/a n/a n/a 06 n/a n/a 06

PXD 06 n/a 06 n/a n/a n/a n/a 06 n/a n/a 06

15"

PX 15 n/a 15 n/a n/a 15 15 15 15 15 15

PXD 15 n/a 15 n/a n/a 15 15 15 15 15 15

PXD_2 15 n/a 15 n/a n/a n/a n/a 15 15 15 15

PXL 15 n/a 15 n/a n/a n/a n/a 15 15 15 15

Add-On

Height

Frame Style

PE = Power Panel | PM = Modular Power Panel | PX = Super Power Panel

Page 12: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

t/o/s application guide – April 30, 2018

privacy screen basics

• Must be mounted on adjacent Panels of the same height• The total combined width of the adjacent panels must be equal to or greater than the screen width• May be same width or wider than opening to be covered• Cannot mount to 30" wide Panels; mounting brackets interfere with panel connections• The Privacy Screen is not load bearing• Direction in which the door will slide can be changed in the field• Comes complete with caps and mounting hardware

The Privacy Screen (PPSF) is a lightweight, translucent panel-mounted, sliding partition.

Overhead Cabinets cannot bemounted using off-module bracketson the same Panel as the PrivacyScreen

Add-On Modules (PX) and OverPanels (PO) cannot be applied onthe top of the Panel to which thePrivacy Screen is mounted

•Mounting Brackets for PrivacyScreens are 3" deep

• The face of the Privacy Screen sits3" from the face of the Panel towhich it is attached

36" or 42" w

51" 66" or 81" h

32 1/2" or 38 1/2" w

26 1/2" or 32 1/2" w

3"

3"

37" or 45" w

Actual Screen Size

Finishes

• Screen has a lightweight translucentfinish

• Frame is available in Foundationand Mica Colors• Caps located at the end of the framewill match the Foundation finishcolor selected for the frame. If Micaframe is selected, caps will be Black

This diagram illustrates the location of the mounting brackets anddemonstrates why the 30" wide panel cannot be used

Page 13: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

t/o/s application guide – April 30, 2018

planning with privacy screens

The following scenarios illustrate typical Privacy Screen applications.

screen width 6" wider than openingPrivacy Screen slides to completely cover an opening with 3" on each side

42" wide opening

screen mounted over two panels (Right Slide Shown)Privacy screen can be mounted over two panels except for 30" wide Panels,which cannot be used because mounting brackets interfere with Panel connectors

corner opening (Left Slide Shown)For complete closure the Panel run width that meets the Privacy Screen when fullyclosed must be 6" longer than the parallel run. This will eliminate the gap thatwould be created by the Privacy Screen sitting out 3" from the panel (see below)

42" wide Panel

42" Privacy Screen

screen and opening same width Privacy Screen slides to completely cover an opening

42" wide opening

24" wide panel

24" wide panel

42" wide panel

42" wide opening

42" Privacy Screen

42" Privacy Screen

36" wide opening with 3"overlap on either side

42" wide panel

dimensionplus 6"

equaldimension equal

Right Shown no gap Right Shown 3" gap

Page 14: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

t/o/s application guide – April 30, 2018

bridge basics

The Bridge (TP) is an on or-off module panel-attached tackable space divider that moves easily within a panelenvironment.

• A Bridge Tray (TZB) can bespecified separately for applicationto one or both sides of the Bridge

• The Diskette Holder (ASDH) and alimited selection of PersonalOrganizers (PAX) can be used whenthe Bridge Tray has not been applied(see Compliments catalogue)

Different fabric can be specified forthe left and right side of the Bridge

• The pole and T-end are specified atthe same height

• Equipped with 3" levelers

Equipped with 3" levelers

Finishes• The pole leveler and bridge tray areBlack

• Bridge can be finished with aWhiteboard or Fabric

• Pole, Frame and T-Ends areavailable in Foundation and Micacolors

• Panel-mounting hardware isavailable in Foundation colors

Pole

Fabric orWhiteboard (both sides)

Fabric (both sides)

Outer

Inner

T-End

Frame

Partition can be adjusted vertically in15" increments

51" or 66"

72" - 96"

30 & 45" for 51"high pole & t-end

45" only for 66"high pole & t-end

72" - 96"

• The Bridge is not load bearing. Cannot support shelves, cabinets or worksurfaces• Not freestanding and is not intended to provide panel support• Cannot be higher than the panel spine• Only dry erase markers can be used on the whiteboard• Consists of three parts (frame, pole and T-end), but is ordered as one unit

Page 15: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

t/o/s application guide – April 30, 2018

planning with bridges

• Panel runs must have full Panel support every 120"• Bridge is not freestanding and does not provide Panel support• Attaches to Panel on- or off-module at 21" height on 51" high bridge and at 21" and 51" height on 66" high bridge• Panel-mounted storage must be equally balanced on both sides of the Panel spine

The Bridge (TP) is an on- or off- module panel-attached tackable space divider that moves easily within a panelenvironment. The following rules apply when planning with bridges.

off-module bridge• The bridge may be attached off-module at any point along the rail,up to 5" from the module line

• If the Bridge is placed in front of an access door, the access doorwill not open

on-module bridge with panel spacer• If a Panel spacer is specified where the Bridge is applied, theworksurface can equal the Panel width as the Bridge is mounted offthe Panel Spacer

• The mounting bracket used to lock the Bridge to the panel istypically installed at the 36" height. A secondary bracket is used atthe 21" or 51" heights

Module Line

If no spacer is used, shorten surface6" to allow for bridge

6"

Panel with Spacer

Bridge does not provide Panelsupport; panel run must be supportedby off-module cantilever with foot, C-Leg, Flush End Gable or Panel every120"

120"

Module Line

5"

Available attachment

area

5"

Page 16: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

t/o/s application guide – April 30, 2018

door panel basics

• Door Panels must be connected to Panels of the same height or higher• Add-on Module (PX) or Over Panel (PO) of the same width can be stacked on the Door Panel• For wheelchair accessibility, specify the 42" wide Door Panel• If the Door Panel is to be attached to a Wall Adapter (PWA), Panel Hinges (PH40) must be ordered• The door swing is identified as left and right according to the location of the hinges

The Door Panel (PD) allows for door applications within the Panel environment, however does not allow for power pass-through or power access.

Finishes • Doors are available in FoundationLaminate, and Flintwoods finishes

• Frame is available in Foundationand Mica colors

• Top trims are available inFoundation and Mica colors andFlintwood stains

• If Flintwood is not specified for thetop trim finish, the finish will matchthe finish color of the frame

• Handles, locks and thresholds arefinished in a Brushed Chrome

Handle Style 1(Ball Handlewith Lock)

Handle Style 2(Lever Handle with Deadbolt)

Handle Style 3(Lever Handle No

Lock)

Handle Style 9(No Handle)

This style is not available in the U.S.A.

Door Door Dimensions Door Clearance (Nominal) (Frame width: side-to-side)

PD_8136 79" high x 32" wide 31"

PD_8142 79" high x 38" wide 37"

81"

36" or 42"

Page 17: 02A TOS Panels - · PDF fileA variety of optional element types are available Acoustic Elements (PAA)are the default elements for both inner and outer sides of the panels An enclosed

panels

t/o/s application guide – April 30, 2018

panel T basics

• The Panel T and trim adapter are supplied at the same height• Does not provide primary support for panel-mounted worksurfaces

The Panel T (TPTA) adds an architectural accent to a workstation while providing a secondary support to the end of apanel.

Trim adapter; color should matchpanel frame

End Trim

22"

36" - 66"

Leveling adjustment range of 3"

If the Panel T is shorter than thePanel to which it is applied,additional Intermediate Trim must bespecified

Finishes• Panel T is available in a selection ofFoundation and Mica colors

• Trim adapter is available in aselection of Foundation colors

• Panel trim adapter should match thePanel frame not the Panel T

• Hardware is Black