Multigang Installations When combining controls in a wallbox, remove all inner side sections prior to wiring (see below). Use pliers to bend side section up and down until it breaks off. Repeat for each side section to be removed. Note: No derating is required if ganged. Limited Warranty (Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.) Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you. This product may be covered under the following U.S. patent: 7,105,763; and corresponding patents of other countries. U.S. and other patents pending. Lutron is a registered trademark and Ceana and Fassada are trademarks of Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. © 2007 Lutron Electronics Co., Inc. Installation ON OFF ON OFF ON OFF Turning Power OFF. Turn power OFF at circuit breaker (or remove fuse). 1 Danger: Verify power to switch is OFF before proceeding. Removing Wallplate and Switch. Remove the wallplate and switch mounting screws. Carefully remove switch from wall (do not remove wires). Identifying Type of Circuit. 2 Disconnecting Switch Wires. 4 Wiring the Switch.. 5 Align switch and tighten screws clockwise. Turn screws clockwise to start. Mounting Switch to Wallbox. • Form wires carefully into the wallbox, mount and align switch. • Install wallplate. 6 ON OFF ON OFF ON OFF Turning Power ON. Turn power ON at circuit breaker (or replace fuse). 7 ? Technical Assistance If you have questions concerning the installation or operation of this product, call the Lutron Technical Support Center. Please provide exact model number when calling. U.S.A. and Canada (24 hrs/7days) 1-800-523-9466 Other countries 8am – 8pm ET +1-610-282-3800 Fax +1-610-282-6311 http://www.lutron.com 030-948 030-948 English Screw Terminals: Turn screws counterclockwise to loosen. Push-in Terminals: Insert screwdriver and pull wire out. Important Wiring Information 5a - Single-Pole Wiring 5b - 3-Way Wiring Push-in Terminals: Insert wires fully. Push-in terminals are for use with #14 AWG solid copper wires only. For aluminum wires, consult an electrician. DO NOT use stranded or twisted wires. Screw Terminals: Tighten securely. Screw terminals are for use with solid copper wires only. For aluminum wires, consult an electrician. DO NOT use stranded or twisted wires. Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the switch. Use the same procedure to wire the new switch as was used with the old switch (see step 4 and below). OR Connect the bare copper or green ground wire to the green ground wire on the switch (see Important Note 4). • Connect one of the insulated wires removed from the switch to either of the screws (or push- in terminals) on the switch. • Connect the other insulated wire removed from the switch to the other screw (or push-in terminal) on the switch. Note: If a single-pole switch is to be replaced with a 3-way switch, the screw on the opposite side of the different colored screw is not used. Tighten it securely and follow instructions for “Single- Pole Wiring”. Live 120 V~ 60 Hz Light Single-Pole Switch Neutral Ground Live 120 V~ 60 Hz Light 3-Way Switch 3-Way Switch Neutral Ground Ground Ground Ground (Green wire) Different- colored screw Tag Reference Wiring Diagram Reference Wiring Diagram (Green) wire Important Note: The wall switch may have two wires attached to the same screw (see illustrations below for examples). Tape these two wires together before disconnecting. When wiring, connect wires to the new switch the same way they were connected to the old switch. One wire in the backwired hole and one to the screw. One continuous wire to the screw. Turn screws to loosen. Each control has inside section removed. Middle control has two side sections removed. Lutron Technical Support Center 1-800-523-9466 24 hrs / 7 days www.lutron.com Single-Pole Switch CN-1PS 120 V~ 60 Hz 15 A 3-way Switch CN-3PS 120 V~ 60 Hz 15 A Purchase Lutron wallplate separately. Important Notes Please read before installing 1. When no “grounding means” exist within the wallbox then the NEC® 2005, Article 404-9 allows a switch without a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, cap or remove the green ground wire on the switch and use an appropriate wallplate such as Lutron’s FassadaTM series wallplates. 2. Connect only # 12 AWG or # 14 AWG gauge copper or copper clad wire to switch. See device for strip length. 3. Install in accordance with all national and local electrical codes. 4. DO NOT use CeanaTM switches for compact Fluorescent (Energy Saver) lamps. 5. Clean unit with a soft damp cloth only. Do not use any chemical cleaners. Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299, U.S.A. Made and printed in U.S.A. 7/07 P/N 030-948 Rev. A 3 Ground (bare copper or green wire) Ground (bare copper or green wire) Single-pole circuit: Insulated wires connected to two screws of the same color. Replace with a single-pole or 3-way switch. Follow wiring “Single-Pole Wiring” when completing step 5. 3-way circuit: Insulated wires connected to three screws. One of these wires is connected to a screw of a different-color. Tag this wire to identify it when wiring. Replace with a 3-way switch. Follow wiring “3-Way Wiring” when completing step 5. OR OR Different-colored screw (COMMON) Tag 1/2 in (13 mm) OR • Connect the green or bare copper ground wire to the green ground wire on the switch (see Important Note 4). • Connect the tagged wire removed from the switch to the different-colored screw (or push-in terminal) on the switch. • Connect one of the remaining wires removed from the switch to either of the remaining screws (or push-in terminal) on the switch. • Connect the last wire removed from the switch to the remaining screw (or push-in terminal) on the switch. Caution: Do not overtighten mounting screws. In a multigang installation, tightening can make it difficult to install the wallplate.

Upload: exclusive-lighting-solutions

Post on 12-Mar-2016

212 views

Category:

Documents


0 download

DESCRIPTION

Lutron Technical Support Center 1-800-523-9466 24 hrs / 7 days www.lutron.com U.S.A. and Canada (24 hrs/7days) 1-800-523-9466 Other countries 8am – 8pm ET +1-610-282-3800 • Form wires carefully into the wallbox, mount and align switch. • Install wallplate.

TRANSCRIPT

Page 1: 030948a

Multigang InstallationsWhen combining controls in a wallbox, remove all inner side sections prior towiring (see below). Use pliers to bend side section up and down until itbreaks off. Repeat for each side section to be removed. Note: No derating isrequired if ganged.

Limited Warranty(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture withinone year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIEDWARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTYDOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGERESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION.THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’SLIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THEMANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THEPURCHASE PRICE OF THE UNIT.This warranty gives you specific legal rights, and you may have other rights which vary from state tostate. Some states do not allow the exclusion or limitation of incidental or consequential damages, orlimitation on how long an implied warranty may last, so the above limitations may not apply to you.This product may be covered under the following U.S. patent: 7,105,763; and corresponding patents ofother countries. U.S. and other patents pending. Lutron is a registered trademark and Ceana andFassada are trademarks of Lutron Electronics Co., Inc. NEC is a registered trademark of the NationalFire Protection Association, Quincy, Massachusetts.© 2007 Lutron Electronics Co., Inc.

Installation

ON

OF

F

ON

OF

F

ON

OF

F

Turning Power OFF.• Turn power OFF at circuit breaker (or remove fuse).

11

Danger: Verifypower to switch isOFF beforeproceeding.

Removing Wallplate andSwitch.• Remove the wallplate and switch mounting screws.• Carefully remove switch from wall (do not remove wires).

Identifying Type of Circuit.

22

Disconnecting Switch Wires.44

Wiring the Switch..55

Align switch

and tighten

screws

clockwise.

Turn screws

clockwise to

start.

Mounting Switch to Wallbox.• Form wires carefully into the wallbox, mount and align switch.• Install wallplate.

66

ON

OF

F

ON

OF

F

ON

OF

F

Turning Power ON. • Turn power ON at circuit breaker (or replace fuse).

77

? Technical AssistanceIf you have questions concerning the installation or operation of thisproduct, call the Lutron Technical Support Center. Please provideexact model number when calling.

U.S.A. and Canada (24 hrs/7days) 1-800-523-9466 Other countries 8am – 8pm ET+1-610-282-3800

Fax +1-610-282-6311

http://www.lutron.com

030-

948

030-

948

English

Screw Terminals:

Turn screws

counterclockwise to

loosen.

Push-in Terminals:

Insert screwdriver

and pull wire out.

Important Wiring Information

5a - Single-Pole Wiring

5b - 3-Way Wiring

Push-in Terminals: Insertwires fully. Push-in terminalsare for use with #14 AWG solidcopper wires only. Foraluminum wires, consult anelectrician. DO NOT usestranded or twisted wires.

Screw Terminals: Tightensecurely. Screw terminals are foruse with solid copper wiresonly. For aluminum wires,consult an electrician. DO NOTuse stranded or twisted wires.

Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the switch.Use the same procedure to wire the new switch as was used with the old switch (see step 4and below).

OR

• Connect the bare copper orgreen ground wire to the greenground wire on the switch (seeImportant Note 4).

• Connect one of the insulatedwires removed from the switchto either of the screws (or push-in terminals) on the switch.

• Connect the other insulated wireremoved from the switch to theother screw (or push-in terminal)on the switch.

• Note: If a single-pole switch is tobe replaced with a 3-way switch,the screw on the opposite side ofthe different colored screw is notused. Tighten it securely andfollow instructions for “Single-Pole Wiring”.

Live

120 V~60 Hz

Light

Single-PoleSwitch

Neutral

Ground

Live

120 V~60 Hz

Light

3-WaySwitch

3-WaySwitch

Neutral

Ground Ground

Ground

Ground(Green wire)

Different-coloredscrew

Tag

Reference Wiring Diagram

Reference Wiring Diagram

(Green) wire

Important Note: The wall switch may have two wires attached to the samescrew (see illustrations below for examples). Tape these two wires togetherbefore disconnecting. When wiring, connect wires to the new switch thesame way they were connected to the old switch.

One wire in

the backwired

hole and one

to the screw.

One

continuous

wire to the

screw.

Turn screws

to loosen.

Each control hasinside section

removed.

Middle control has two side sections

removed.

Lutron Technical Support Center 1-800-523-9466 24 hrs / 7 days www.lutron.com

Single-Pole SwitchCN-1PS 120 V~ 60 Hz 15 A

3-way SwitchCN-3PS 120 V~ 60 Hz 15 A

Purchase Lutron wallplate separately.

Important NotesPlease read before installing

1. When no “grounding means” exist within the wallbox then the NEC® 2005, Article404-9 allows a switch without a grounding connection to be installed as areplacement, as long as a plastic, noncombustible wallplate is used. For this typeof installation, cap or remove the green ground wire on the switch and use anappropriate wallplate such as Lutron’s FassadaTM series wallplates.

2. Connect only # 12 AWG or # 14 AWG gauge copper or copper clad wire to switch.See device for strip length.

3. Install in accordance with all national and local electrical codes.4. DO NOT use CeanaTM switches for compact Fluorescent (Energy Saver) lamps.5. Clean unit with a soft damp cloth only. Do not use any chemical cleaners.

Lutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA 18036-1299, U.S.A.Made and printed in U.S.A. 7/07 P/N 030-948 Rev. A

33

Ground(barecopper orgreen wire)

Ground(barecopper orgreen wire)

Single-pole circuit:Insulated wires connected to two screws ofthe same color. Replace with a single-pole or3-way switch. Follow wiring “Single-PoleWiring” when completing step 5.

3-way circuit:Insulated wires connected to three screws.One of these wires is connected to a screw ofa different-color. Tag this wire to identify itwhen wiring. Replace with a 3-way switch.Follow wiring “3-Way Wiring” whencompleting step 5.

OR

OR

Different-coloredscrew (COMMON)

Tag

1/2 in

(13 mm)

OR

• Connect the green or barecopper ground wire to the greenground wire on the switch (seeImportant Note 4).

• Connect the tagged wireremoved from the switch to thedifferent-colored screw (orpush-in terminal) on the switch.

• Connect one of the remainingwires removed from the switchto either of the remainingscrews (or push-in terminal) onthe switch.

• Connect the last wire removedfrom the switch to theremaining screw (or push-interminal) on the switch.

Caution: Do notovertightenmounting screws.In a multiganginstallation,tightening canmake it difficult toinstall the wallplate.

Page 2: 030948a

Instalaciones con VariosComponentesAl combinar controles en una caja de empotrar, extraiga todas las seccioneslaterales interiores antes de cablear (vea debajo). Utilice pinzas para doblarcada sección lateral hacia arriba y hacia abajo hasta que se quiebren. Repitael proceso para cada sección a remover. Nota: No se requiere reducción depotencia nominal si es agrupado.

Garantía Limitada(Válido solamente en los E.U.A., Canadá, Puerto Rico y el Caribe.)Lutron, a discreción propia, reparará o reemplazará las unidades con fallas en sus materiales ofabricación dentro del año posterior a la compra de las mismas. Para obtener el servicio de garantía,remita la unidad al lugar donde la adquirió o envíela a Lutron, 7200 Suter Rd., Coopersburg, PA18036-1299, con servicio postal prepago.ESTA GARANTÍA REEMPLAZA A TODA OTRA GARANTÍA EXPRESA Y LA GARANTÍA IMPLÍCITA DECOMERCIABILIDAD ESTÁ LIMITADA A UN AÑO DESDE LA FECHA DE COMPRA. ESTA GARANTÍA NOCUBRE EL COSTO DE INSTALACIÓN, DE REMOCIÓN NI DE REINSTALACIÓN, NI LOS DAÑOSPROVOCADOS POR USO INCORRECTO O ABUSO NI LOS DAÑOS RESULTANTES DE UN CABLEADO OUNA INSTALACIÓN INCORRECTOS. ESTA GARANTÍA NO CUBRE DAÑOS INCIDENTALES OINDIRECTOS. LA RESPONSABILIDAD DE LUTRON ANTE UNA DEMANDA POR DAÑOS CAUSADOSPOR O RELACIONADOS CON LA FABRICACIÓN, VENTA, INSTALACIÓN, ENTREGA O USO DE LAUNIDAD NO EXCEDERÁ EN NINGÚN CASO EL PRECIO DE COMPRA DE LA UNIDAD.La presente garantía le otorga derechos legales específicos y usted puede tener otros derechos quevarían según el estado. Algunos estados no admiten la exclusión o limitación de los daños incidentaleso indirectos, ni las limitaciones en la duración de las garantías implícitas, de modo que laslimitaciones anteriores pueden no ser aplicables en su caso.Este producto puede estar cubierto por las siguientes patentes de E.U.A.: 7,105,763; ycorrespondientes patentes extranjeras. Patentes pendientes de E.U.A., y extranjeras. Lutron es unamarca registrada y Ceana y Fassada son marcas registradas de Lutron Electronics Co., Inc. NEC esuna marca comercial registrada de la National Fire Protection Association, Quincy, Massachussets.© 2007 Lutron Electronics Co., Inc.

Instalación

ON

OF

F

ON

OF

F

ON

OF

F

Apagado.• Desconecte la alimentación en el cortacircuito (o quite el fusible).

11

Peligro:Compruebe que laalimentación a losinterruptores estédesconectadaantes de proseguir.

Remoción de la placa depared y el interruptor.• Retire la placa de pared y los tornillos de montaje del interruptor.• Retire el interruptor de la pared con cuidado (no saque los

cables).

Identificación del tipo decircuito.

22

Desconexión de los cablesdel interruptor.

44

Cableado del interruptor..55

Alinee el

interruptor y

ajuste los

tornillos en

sentido

horario.

Gire los

tornillos en

sentido

horario para

comenzar.

Montaje del interruptor en lacaja de empotrar.• Coloque los cables cuidadosamente en la caja de empotrar,

monte y alinee el interruptor.

• Instale la placa de pared

66

ON

OF

F

ON

OF

F

ON

OF

F

Encendido.• Encienda desde el cortacircuito (o vuelva a colocar el fusible).

77

? Asistencia TécnicaSi usted tiene alguna duda con respecto a la instalación o alfuncionamiento de este producto, comuníquese con el Centro deSoporte Técnico de Lutron. Por favor, indique el modelo exacto alllamar.

E.U.A. y Canadá (24 horas/7 días a la semana)1-800-523-9466Otros países 8 a.m. – 8 p.m.(Hora del Este)+1-610-282-3800

Fax +1-610-282-6311

http://www.lutron.com

Español

Bornes de tornillo:

Gire los tornillos en

sentido contrario a las

agujas del reloj para

aflojar.

Bornes a presión:

Introduzca el

destornillador y

extraiga el cable.

Información Importante sobre Cableado

5a – Cableado Unipolar

5b - Cableado de 3 vías

Borneras a presión: Insertelos cables completamente. Lasborneras a presión sólo seutilizan solamente con cablesde cobre sólido #14 AWG. Paracables de aluminio, consulte unelectricista. NO utilice cableretorcido ni trenzado.

Bornes de Tornillo: Ajústelosen forma segura. Los bornesde tornillo deben usarsesolamente con cable de cobresólido. Para cable de aluminio,consulte a un electricista. NOuse cable cortado o retorcido.

Recorte o pele los cables de la caja de empotrar en el indicado en el reverso del interruptor.Utilice el mismo procedimiento que utilizó con el antiguo interruptor para cablear su nuevointerruptor (vea Paso 4 y debajo).

O

• Conecte el cable a tierra verde ode cobre sin aislamiento al cablea tierra verde del interruptor (veala Nota Importante 4).

• Conecte uno de los cablesaislados extraídos del interruptora uno de los tornillos (o bornes apresión) en el interruptor.

• Conecte el cable aisaldo restanteextraído del interruptor al otrotornillo (o borne a presión) en elinterruptor.

• Nota: Si usted estáreemplazando un interruptorunipolar con un interruptor de 3posiciones, el tornillo en el ladoopuesto del tornillo de colordiferente, no va a ser utilizado.Ajústelo en forma segura y sigalas instrucciones para cableadounipolar.

Vivo

120 V~60 Hz

Luz

Interruptor dePolo Sencillo

Neutro

Tierra

Vivo

120 V~60 Hz

Luz

Interruptor de 3

Posiciones

Interruptor de 3 Posiciones

Neutro

Tierra Tierra

Tierra

Cable a tierra(Verde)

Tornillo dedistinto

color

Identificación

Diagrama de Referencia de Cableado

Diagrama de Referencia de Cableado

Cable (verde)

Nota Importante: Su interruptor de pared puede tener dos cablesconectados al mismo tornillo (vea los ejemplos ilustrados a continuación).Una ambos cables con cinta adhesiva antes de desconectarlos. Cuandorealice el cableado, conecte los cables al nuevo Interruptor de la mismaforma que estaban conectados al interruptor que se reemplaza.

Un cable en

el orificio con

cableado

posterior y

uno al

tornillo.

Un cable

continuo al

tornillo.

Afloje los

tornillos.

A cada control se leha quitado la

sección interior

Al control del medio se lehan quitado las secciones

laterales

Centro de Soporte Técnico de Lutron 1-800-523-9466 24 horas / 7 días www.lutron.com

Interruptor de Polo SencilloCN-1PS 120 V~ 60 Hz 15 A

Interruptor de 3 víasCN-3PS 120 V~ 60 Hz 15 A

Adquiera la placa de pared Lutron por separado.

Notas importantesPor favor lea antes de instalar

1. Cuando dentro de la caja de empotrar no hay “medios de conexión a tierra” elArtículo 404-9 de NEC® 2005 permite la instalación de un interruptor sin conexióna tierra como reemplazo, siempre y cuando se utilice una placa de pared plásticae incombustible. Para efectuar este tipo de instalación tape o retire el cable verdede conexión a tierra del interruptor y use una placa de pared adecuada como lasde la serie FassadaTM de Lutron.

2. Conecte al interruptor solamente cables de cobre o recubiertos de cobre # 12 AWG o # 14 AWG. Vea el dispositivo para establecer la longitud adecuada dela parte descubierta del cable.

3. La instalación se debe realizar de acuerdo con todos los códigos eléctricosnacionales y locales.

4. NO USE interruptores CeanaTM para lámparas Fluorescentes compactas (de Ahorrode Energía).

5. Limpie la unidad con un trapo húmedo solamente. No utilice productosquímicos.

Lutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA 18036-1299 E.U.A.Hecho e impreso en los E.U.A. 7/07 P/N 030-948 Rev. A

33

Tierra(cable decobre rasoo verde)

Tierra(cable decobre rasoo verde)

Circuito UNIPOLAR:Los cables aislados conectados a dos tornillosdel mismo color. Reemplace con uninterruptor unipolar o de 3 posiciones. Siga elcableado "Cableado Unipolar" al completar elPaso 5.

Circuito DE 3 POSICIONES:Cables aislados conectados a tres tornillos.Uno de estos cables está conectado a untornillo de un color diferente. Marque estecable para identificarlo al cablear.Reemplácelo con un interruptor de 3posiciones. Siga el cableado “Cableado de 3posiciones” al completar el Paso 5.

O

O

Tornillo de distintocolor (Común)

Identificación

13 mm

(1/2 in)

O

• Conecte el cable a tierra verde ode cobre sin aislamiento alcable a tierra verde en elinterruptor (vea la NotaImportante 4).

• Conecte el cable Rotulado quese removió del interruptor altornillo de color diferente (oborne a presión) en elinterruptor.

• Conecte uno de los cablesrestantes extraídos delinterruptor a uno de los tornillosrestantes (o bornes a presión)en el interruptor.

• Conecte el último cable extraídodel interruptor al tornillorestante (o borne a presión) enel interruptor.

Cuidado: Noajuste demasiadolos tornillos demontaje. En unainstalación dedispositivosmúltiples estopuede dificultar lainstalación de laplaca de pared.