7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 1/24 OMS-B Overview Siemens  MN1780EU09MN_0001  © 2002 Siemens AG 1 Contents 1 Radio Commander 3 1.1 TMN Platform 4 1.2  Architecture 6 1.3 OMS-B to BSS Connectivity 11 1.4 Graphical User Interface 14 1.5 OMC Tool Set 18 2  Appendix 21 2.1 Local Maintenance Terminal 22 OMS-B Overview

Upload: alqousimuhieddine

Post on 03-Mar-2016

12 views

Category:

Documents


0 download

DESCRIPTION

ffdfds

TRANSCRIPT

Page 1: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 1/24

OMS-B Overview Siemens

 

MN1780EU09MN_0001 © 2002 Siemens AG

1

Contents

1  Radio Commander 3 

1.1  TMN Platform 4 

1.2   Architecture 6 

1.3  OMS-B to BSS Connectivity 11 

1.4  Graphical User Interface 14 

1.5  OMC Tool Set 18 

2   Appendix 21 

2.1  Local Maintenance Terminal 22 

OMS-B Overview

Page 2: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 2/24

Siemens OMS-B Overview 

 

MN1780EU09MN_0001

© 2002 Siemens AG

2

Page 3: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 3/24

Page 4: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 4/24

Siemens OMS-B Overview 

 

MN1780EU09MN_0001

© 2002 Siemens AG

4

1.1 TMN Platform

The Radio Commander RC is an Operation & Maintenance Center OMC providingelement management functionality for both 2nd generation and 3rd generation radioaccess networks. 

Network

Mgmt

Element

Management

Network

Elements

Service

Management

HLRHLR

other NE

(transport)other NE

(transport)BSSBSS

INCommander 

SwitchCommander 

RadioCommander 

EM of 

other NE

RNC

NodeBRNC

NodeBMSCMSC   UMSCUMSC

SMAPSMAP

SMPSMP   SCPSCP

Network

Planning

Tools

GSNGSN

Service Management Tools

Mobile Integrator SPOTS

Performance

Management

 

Fig. 1 TMN Platform

Page 5: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 5/24

OMS-B Overview Siemens

 

MN1780EU09MN_0001 © 2002 Siemens AG

5

Software

• Fault Management

• Configuration Mgmt.

• Performance Mgmt.

• Security Mgmt.

• SUN Solaris operat. system

• Oracle database

Hardware

•   OMP SUN Ultra 4500

•  OMT

- SUN Ultra10 (WS)

- Ultra60 (XT Server)

- Ultra5 (X-Terminal)

Q3 over

X.25/nailed-up

OMT(s)

LMT

NMC

OMC-S

Q3

Radio

Commander 

OMP(s)

BSC

BSC

 

Fig. 2 Radio Commander - Structure

Fig. 3 Radio Commander Basic and Application Packages

Page 6: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 6/24

Siemens OMS-B Overview 

 

MN1780EU09MN_0001

© 2002 Siemens AG

6

1.2 Architecture

The Radio Commander is designed as a distributed computing system consisting of aset of components connected via LAN. The architecture is based on the client/serverprinciple, which contributes to system flexibility and robustness.

Within the Radio Commander hardware architecture, the roles are distributed asfollows:

OMP (Operation and Maintenance Processor, the "server")

OMTs (Operation and Maintenance Terminals, the "clients"), typically graphical workstations for (among others)

visualization and control of network elements,

managing the BSS file system, down-/uploading files (software, database) and

collecting measurement data

In addition, the hardware is composed of the following components:

Connection equipment

Hardware for LAN and X.25 / PCM connectivity

LAN Printers

Storage devices

 Additional streamer tapes

External disk storage

Radio Commander is scalable in both hardware (multi-server/multi-processor system)and software (distribution of software processes over logical servers, easy extensionof object model etc.) System reliability is improved with load-sharing.

1.2.1 Basics

The hardware of the new Radio Commander is a commercial UNIX-based systemaimed at providing a high a degree of modularity and flexibility.

With a growing number of BSS being connected to the system, the processing powercan be easily extended by

hardware upgrade of the OMP itself (CPU, RAM, hard disk capacity),

use of additional servers (load sharing).

There is no limitation to the number of terminals that can be connected to the OMP.

Page 7: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 7/24

OMS-B Overview Siemens

 

MN1780EU09MN_0001 © 2002 Siemens AG

7

1.2.2 Capacity

The following table refers to networks composed exclusively of GSM networkelements (* E4x00 only for existing projects):

OMP configuration GSM managed networkelements

No of CPU /

RAM in GB

Type ofserver

Basic OMP 2500 TRX / 10 BSC 2 / 2 E420R

Basic OMP 10000 TRX / 40 BSC 4 / 4 E420R

Extended Simple OMP 12000 TRX / 48 BSC 4 / 4 E4x00

Ultra 10

OMT (2 sessions)

Ultra 60

OMT Server 

Ultra 5

Minimum OMT (1 session)

Ultra 1 / 200E

X Terminal

Ultra 1 / 140E Ultra 1 / 170E

 

Fig. 4 OMT / Xterminal supported

Page 8: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 8/24

Siemens OMS-B Overview 

 

MN1780EU09MN_0001

© 2002 Siemens AG

8

Ultra 10

E4500 / E4000

E420R

Ultra5

MSC

BSC

BSC

X Termina l X Terminal

CLI telnetaccess

CLI modemaccess

remote OMT remote OMT

X TerminalServer 

X.25

LANDedicated

X.25

PCM30/24 "nailed-up"

connection

Hub

OMTOMTLAN

OMP

X.25 net

Modem

BSC

•   OMP is scalable

– Basic OMP: SUN server E420R

– ...

– Multiple OMP: SUN server E4500 + E420R

•   OMT Hardware:

– SUN Ultra 5 / 10 / 60 

Fig. 5 OMP and OMT hardware - overview

Sun Blade 1000

LAN (10/100BaseT)

O MT   O MT

OM P

O&M ToolSet Server  

O MT

MultiPack

O MT

 

Fig. 6 O & M tool set

Page 9: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 9/24

OMS-B Overview Siemens

 

MN1780EU09MN_0001 © 2002 Siemens AG

9

Sun Server

Enterprise 4500

LAN (Fast Ethernet 10/100BaseT)

Console

OMT

ColourSpoolprinter 

OMT

Spoolprinter b&w 

NE‘sNE‘s

DiskArray

 Alarm Printer 

DiskArray

OMP with internal redundancy:- mirrored internal HDDs

- doubled I/O boards

- doubled communication boards

- doubled LAN connections

- mirrored external HDDs

 

Fig. 7 Redundant OMP - Hardware Architecture

NE‘sNE‘s

Sun Server

Enterprise 4500

Sun Server

Enterprise 420R

Console

LAN (Fast Ethernet 10/100BaseT)

Primary Server    Secondary Server 

ColourSpoolprinter 

OMTOMT

Spoolprinterb&w 

DiskArray

 Alarm Printer 

NE‘sNE‘s

Multiple OMP: Logical OMC with transparent access

to common database from every OMT

 

Fig. 8 Multiple OMP - Hardware Architecture

Page 10: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 10/24

Siemens OMS-B Overview 

 

MN1780EU09MN_0001

© 2002 Siemens AG

10

1.2.3 Comparison: Hardware OBR5.5 vs. RC6.0

OMP

SparcServer 1000

OBR5.xOBR5.x RC6.0RC6.0

CPU (in E4000)

CPU 167Mhz

Int. HDD (in E4x00)

2 x 2.1GB

X.25 Comm. Board

 Aurora Unit

OMC National

OMP, OMT, etc.

OMP

Suitable OMP Configuration

CPU

CPU 400Mhz

Int. HDD (in E4x00)

2 x 4.2GB

X.25 Communication Board

HSI board

OMT National

Ultra 80

 

Fig. 9 Changes in supported hardware between OBR5.5 and OBR6.0

OMP (E4x00):

2 x CPU 250Mhz

2 x CPU 400Mhz

512MB RAM

OMP (E4x00)

4 x CPU 250Mhz

4 x CPU 400Mhz

4 GB RAM

OBR5.xOBR5.x RC6.0RC6.0

Single OMP (E4x00):

1 existing E4x00

Multiple OMP:

additional E420R / E4500

External Harddisks:

Multipack

(54 GB / 109GB)

External Harddisks:

DiskArray D1000

(145 GB / 218 GB / 436 GB)

Backup&Restore (opt.

Feature):

DDS3 Autoloader 

Backup&Restore (opt.

Feature):

DLT Autoloader L9

Mandatory

Optional

 

Fig. 10 Hardware upgrade between OBR5.x and OBR6.0 (mandatory above, optional - depending on the number of TRX / BSC,below)

Page 11: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 11/24

OMS-B Overview Siemens

 

MN1780EU09MN_0001 © 2002 Siemens AG

11

1.3 OMS-B to BSS Connectivity

The connection between OMC-B and SBS is called OMAL. It can be implemented with (cold standby) redundancy.

1. Connection via PCM- Links

The OMAL (at a transmission rate of 64 kbit/s) is mapped on the BSC site in thePCMS Link, connecting BSC with TRAU and the MSC site.

The OMAL is transferred through the TRAU transparently.

 At the MSC the incoming OMAL of several incoming PCMA Links are multiplexed intoa common 2 Mbit/s link (based on the PCM30 structure), which is directly connected

 with the OMC.

This implementation is called “nailed up connection“. The OMC can control andsupervise up to 30 BSS.

 A Newbridge Sprite E1 board, equipped inside the OMP, implements thiscommunication interface.

2. Connection via Dedicated Line

The connection via dedicated line can be realized in two ways:

dedicated point to point link

connection via a private or public Packet Switched Data Network

 At the BSC site the interface is provided by the IXLT board and is based on the X.21/ V.11.

 At the OMC an external communication controller, the HSI/PCI interface board,provides the interface.

The X.25 packet switched data network requires special modems to convert the X.21/ V.11 interface into the X.25 protocol, used at the packet switched data network.

 A HSI/PCI board can be installed in the servers Sun Enterprise 4500:

HSI/PCI (High-SpeedInterface/Personal ComputerInterface)

offers four X.25 ports, each with max. 2 Mbit/sthroughput, corresponding to 4 x 30 remote systemsat 64 kbit/s per port

Page 12: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 12/24

Siemens OMS-B Overview 

 

MN1780EU09MN_0001

© 2002 Siemens AG

12

OMP - BSC connection:

OMAL

 Via A interface (PCM lines)

and nailed-up connection (NUC)

through the MSC

 Via X.25 packet data network

(switched virtual circuit) or 

point-to-point dedicated link

 

Fig. 11 Implementation of OMAL

PCMS

BSC

I

 X

LT

S

Y

N

C

H

R

O

TS 30

OMAL

TRAU

MSC

Semi permanent

or nailed up

connection (64 kbit/s)

X25A

Newbridge Sprite E1

OMP

 

Fig. 12 Interface card Newbridge sprite E1 (back view)

Page 13: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 13/24

OMS-B Overview Siemens

 

MN1780EU09MN_0001 © 2002 Siemens AG

13

BSC

I

X

L

T

OMC

H

S

I

P

C

I

PSDN

 X.25 network

Modem Modem

dedicated point to point connection

connection via a packet switched data network

 X.21/ V.11 Interface

 

Fig. 13 Two options for implementing a dedicated line

Operation and Maintenance Processor OMP

X.25 Packet Data Network PDN

Newbridge Sprite E1

 AURORA

HSI / PCI Board

MSC

TRAU

BSC BSC BSC

PCM Link E1 / T1max 31 /24 TS(each 64 kbit/s)

48 Links X.25

(each 64 kbit/s)

4 Links X.25(each 2 Mbit/s)

Nailed-Up Connection(64 kbit/s)

X.25 Connection

(64 kbit/s)

Not  for

OBR6.0

 

Fig. 14 Realization of OMAL (i/f between OMC-B and SBS)

Page 14: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 14/24

Siemens OMS-B Overview 

 

MN1780EU09MN_0001

© 2002 Siemens AG

14

1.4 Graphical User Interface

1.4.1 Basics

The Radio Commander supports different network management views. Customizedgeographical maps, on different scales, represent the territorial structure of thenetwork (e.g. nation, region and district).

The new Radio Commander provides a special maintenance view to let the operatorsee at a glance what is going on in the system. Only vital information is displayed,icons are not overloaded with information.

The Navigator  supports the operator in navigating through the graphical user

interface and Radio Commander’s network editor. The Navigator can be used totallyindependently of the GUI. Hence, it is possible to directly issue commands via thenavigator panel.

The Network Editor  allows flexible customization for GUI online (without reboot ).For basic configuration changes it is also possible to run the Network Editor in stand-alone mode.

The Network Editor supports e.g. "drag & drop" in the customization process. Therange of customization options include

Panel window contents e.g. background, dimensions, graphical objectsrepresented on the panel

Operator-defined network views e.g. new panels, new summary objects

Graphical objects e.g. panel and position in panel, link to managed or externalobject, graphical attributes (line or icon), popup menus

Page 15: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 15/24

OMS-B Overview Siemens

 

MN1780EU09MN_0001 © 2002 Siemens AG

15

Standard Network ViewOperator defined view ‘n’

Operator defined panel contains operator defined summary, ob-jects

and/or single MOs & passive objects

Operator defined panel contains links to the standard network tree

View summary summarizes all operator defined panels

 

Fig. 15 Network Views on Radio Commander

Page 16: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 16/24

Siemens OMS-B Overview 

 

MN1780EU09MN_0001

© 2002 Siemens AG

16

1.4.2 Examples

Fig. 16 Application Launcher

Fig. 17 Geographical Map

Page 17: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 17/24

OMS-B Overview Siemens

 

MN1780EU09MN_0001 © 2002 Siemens AG

17

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fig. 18 BTSone Panel with Logical Icons and Rack Layout (lower left), BSS Region Panel with Help View for State Attributes(upper right)

Page 18: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 18/24

Siemens OMS-B Overview 

 

MN1780EU09MN_0001

© 2002 Siemens AG

18

1.5 OMC Tool Set

BSS data are available "on-line" at the OMC-B and (after export) "off-line" for post-processing by the OMC Tool Set OTS.

OTS integrates and replaces the existing tools

SPOTS (performance management PM),

MIXY (configuration CM and fault management FM) and

DUIT (trace management TrM).

Four packages are available which may be used individually or in combination:

FM+ package supports alarm statistics and reporting.

PM+ package provides reports and analysis of performance and trafficmeasurements.

CM+ package enhances CLI and GUI configuration management.

TrM+ package supports IMSI tracing and Cell Traffic Recording CTR.

Page 19: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 19/24

OMS-B Overview Siemens

 

MN1780EU09MN_0001 © 2002 Siemens AG

19

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fig. 19 Operation and Maintenance Tool Set

Page 20: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 20/24

Siemens OMS-B Overview 

 

MN1780EU09MN_0001

© 2002 Siemens AG

20

Page 21: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 21/24

OMS-B Overview Siemens

 

MN1780EU09MN_0001 © 2002 Siemens AG

21

2 Appendix

Page 22: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 22/24

Siemens OMS-B Overview 

 

MN1780EU09MN_0001

© 2002 Siemens AG

22

2.1 Local Maintenance Terminal

 A few screenshots illustrating LMT handling are given below:

Fig. 20 Pop-Up Menu on LMT Input Handler

Fig. 21 LMT Input Handler with Command Viewer

Page 23: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 23/24

OMS-B Overview Siemens

 

MN1780EU09MN_0001 © 2002 Siemens AG

23

Fig. 22 LMT Input Handler with Pop-Up Menu

Fig. 23 Failure Event Report in Message Browser

Page 24: 07 Mn1780eu09mn 0001 Omsb Overview

7/18/2019 07 Mn1780eu09mn 0001 Omsb Overview

http://slidepdf.com/reader/full/07-mn1780eu09mn-0001-omsb-overview-56d7585681994 24/24

Siemens OMS-B Overview