BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
1
Contents 1 Commissioning procedure 3 2 Visual inspection of BTSE 7 3 Reset CCTRL 11 4 Download BTSE software 15 5 Activate BTSE software 21 6 Set rack 25 7 Create hardware related managed objects 29 7.1 CREATE ENVABTSE 32 7.2 Set attributes for BTS site equipment 33 7.3 Creation of Bport 34 7.4 Enter BTS site manager attributes 36 7.5 LAPDLE creation 38 8 Verify module state/status 41 9 Manually switch to phase three 43 10 Generate backup files 45 11 BTSE restart verification 49 12 Functional structure 53 13 Exercises 59
BTSE commissioning
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
2
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
3
1 Commissioning procedure
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
4
To bring-up the BTSE, follow the "Procedures" chapter in the ITMN:BTSE BS XX. In the CML:BTSE you will find more information about the meaning of specific attributes.
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manually Switchto Phase Three
Reset CCTRL
Download BTSE Software
Activate BTSE Software
Create Hardware RelatedManaged Objects
Set Environmental Alarmsand BTS Site Equipment
Set Rack Attributes
Enter BTS Site ManagerAttributes
Verify ModuleState/Status
Create Bport and Xconnect
Fig. 1 BTSE bring-up
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
6
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
7
2 Visual inspection of BTSE
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
8
Visually inspect the BTSE mechanics, electrics and modules. Follow the appropriate chapters in the ITMN:BTSE BS XX.
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BBSIG
BBSIG
CB FP
AIR FILTER
ACOM
ACOM
ACOM
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
PA
TPU
PA
TPU
PA
TPU
PA
TPU
PA
TPU
PA
TPU
PA
TPU
DCPA
DCTPU
DCTPU
DCPA
DCPA
DCTPU
DCTPU
DCPA
DCPA
DCTPU
DCPA
DCTPU
GPSU
BBSIG
BBSIG
BBSIG
BBSIG
MCLK
CCTRL
LI
ALCO
FANS
Fig. 2 Visual inspection of BTSE
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
10
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
11
3 Reset CCTRL
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
12
Press the small black push button on the CCTRL board. After about 15 seconds the CCTRL reaches the start connection status. LED Indication of CCTRL: RY: green RBM: red ACT: yellow PRGA: off SPA1: off SPA2: green, flashing
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TAD
LED green
LED yellow
Pushbutton
RY
ACT
RES
LED red
LED red
CCTRL
LED green LED greenSPA 1 SPA 2
PRGA
RBM
Fig. 3 CCTRL front plate with LED and reset button
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
14
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
15
4 Download BTSE software
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
16
In BTSE phase 1 only very few commands are available. One of them is DNLALLEXE: LMT tree: MANAGED-ELEMENT --> SOFTWARE-MANAGEMENT Command: DNLALLEXE Name: none Attributes: SCRDIR=<path where the SW Load is stored on the LMT>
HEADER=<enter header according to the SW Load e.g.: HSxxxxxx.SWL> OVERWRITE=YES
Submit Command line: DNLALLEXE:SRCDIR="<path where the SW Load is stored on the LMT>", HEADER="HSxxxxxx.swl", OVERWRITE=YES; The result is a complete SW download, on LMT the load progress in % is indicated. The entire procedure requires about ca 10 minutes. During the download procedure the CCTRL PRGA LED is flashing. Check during downloading whether all BTSE executable files (*.swi files) are successfully transferred.
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fig. 4 Software download to BTSE
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
18
SW Image Description Module btsarc01.swi analog radio controller TPU/TRXA
btsdrx01.swi digital radio controller TPU/TRXD
btsdrx03.swi digital radio controller TPU/TRXD2
btsbbx01.swi baseband and signaling processors BBSIG
btsbbx03.swi baseband and signaling processors BBSIG44
btsbmc01.swi base station master controller CCTRL
btscac01.swi central alarm controller ALCO
btscck01.swi common clock CCLK
btslic01.swi link interface controller LI
btslic04.swi link interface controller LI BTSE executable files
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
19
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LMT
download software
CCTRL Flash EPROM
Fig. 5 Download BTSE software
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
20
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
21
5 Activate BTSE software
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
22
From LMT perform the following steps: LMT tree: MANAGED-ELEMENT --> BSS-FUNCTIONAL --> BTS --> BTSM Command: ACTIVATE BTSM Name: NAME=BTSM:0 Attributes: FID=<Name of the Software Load Header file: HSxxyyzz.SWL>
FV=<Software Load Header: SS-VV-RR-PR-LL-CL_Year-Month-Day Submit Command line: ACTSW BTSM:NAME=BTSM:0,FID=<Name of the Software Load Header file: HSxxyyzz.SWL>, FV=<Software Load Header: SS-VV-RR-PR-LL-CL_Year-Month-Day This procedure requires about 1 minute. The BTSE switches from phase 1 to phase 2 and therefore a new Logon is necessary.
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fig. 6 Activate BTSM
CCTRL Flash EPROM
activate software
RAM of Processors
Fig. 7 Activate BTSE software
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
24
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
25
6 Set rack
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
26
To enter the rack attributes, perform the following steps from LMT: LMT tree: MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE --> RACK Command: SET RACK Name: NAME=RACK:0 Attributes: BATTBAK=<installed or not_installed>
TYPBTSE=BSxx TYPRFSR=<Type of RF Subrack: horizontal or vertical>
Submit Command line: SET RACK:NAME=RACK:0,BATTBAK=<installed or not_installed>,TYPBTSE=BSxx, TYPRFSR=<Type of RF Subrack: horizontal or vertical>;
BA TTBAK This attribute indicates whether or not a battery backup is installed.
TYPBTSE This attribute identifies the type of BTSE. Validity range: BS20, BS21E, BS60, BS61E, BS22.
TYPRFSR This attribute identifies the type of the RF subrack. Validity range: RF_SUBRACK_V1 (horizontal design), RF_SUBRACK_V2 (vertical design).
Rack attributes
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
27
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fig. 8 Set rack attributes
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
28
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
29
7 Create hardware related managed objects
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
30
The CCTRL is the only module, which is created automatically by the system. All other modules have to be created by manually. Creating these so called hardware related managed objects means that the modules are defined in the local database of the BTSE, which is stored on the CCTRL Flash EPROM. For each BTSE up to 14 different types of hardware related managed objects have to be created. For each module (type), which is equipped in the specific BTSE you are just commissioning, perform the following steps from the LMT: LMT tree: MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE --> RACK -->
Module Command: CREATE Module Name: NAME=RACK:0/Module:<Module Number> Attributes: depending on the module type Submit Command line: CREATE Module:NAME=NAME=RACK:0/Module:<Module Number>,Attributes According to this scheme, create all the modules, which are equipped in the specific BTSE you are just commissioning. Refer to the corresponding procedure in the ITMN:BTSE BS XX. The following table summarizes the different types of possible managed objects. Refer to the customer specific documentation in order to determine the managed objects, which need to be created for the site.
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
31
Module Parameter range
ACOM/TXAMOD 0...2
ALCO 0
BBSIG 0...5
CCLK 0
FAN 0...2
GPSU 0
LI 0
PA 0...5
RXAMOD 0...5
RXMUCO/RXAMCO 0...7
TPU 0...5
AC_DC 0
FICOM_VSWR 0...2
FICOM_TNF 0...5 List of the hardware related managed objects
Fig. 9 Example: Creation of ACOM (wiring data)
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
32
7.1 CREATE ENVABTSE To configure external alarms perform the following steps from LMT: LMT tree: MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE --> RACK -->
ENVABTSE Command: CREATE ENVABTSE Name: NAME=RACK:0/ENVABTSE:<Number of environmental alarm> Attributes: INTINF=<interfaceInformation>
ASEV=<associatedSeverity> ASTRING=<associatedString>
Submit Command line: CREATE ENVABTSE:NAME=RACK:0/ENVABTSE:<Number of environmental alarm>, INTINF=<interfaceInformation>, ASEV=<associatedSeverity>, ASTRING=<associatedString>
Number of environmental alarm This attribute selects one of the 20 possible environmental alarms. Validity range: 0 - 19.
associatedSeverity This attribute allows the operator to define a specific severity level for the failure event report related to an environmental alarm. Validity range: CRITICAL, MAJOR, MINOR, WARNING.
associatedString This attribute allows the operator to define a specific text string for the failure event report related to an environmental alarm. Validity range: STRING with max. 26 ASCII characters.
interfaceInformation Depending on the type of external alarm sensor this attribute must be set to high for a break contact (‘’normal closed’’) or to low for a make contact (‘’normal open’’).
Attributes of BTSE environmental alarms
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
33
7.2 Set attributes for BTS site equipment
Fig. 10 Set BTSE attributes
locationName This attribute identifies a location. Validity range: a string of 1 to n, n = 37 characters (default: EARTH).
vendorName This attribute identifies the vendor of the associated object. Validity range: a string of 1 to n, n = 37 characters (default: SIEMENS).
swLoadSafety This attribute describes the file ID and the version number of the SW Load stored in the BTSE as the most trusted SW load that is used if the intended SW is damaged in some way.
salesUniqueName With the help of this attribute a sales unique name can be set. This sales unique name must be a string with min = max = 11 characters.
Important BTS site equipment attributes
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
34
7.3 Creation of Bport Before the BTSM attributes can be set, the Bports must be created. The range of possible values for BS2x/6x is "0,2" A layer1 control timeslot (16 kbit/s) is needed when the line configuration is "loop" or when two PCMB lines are connected to the BTSE. These two configurations are mutually exclusive.
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
35
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fig. 11 Creation of Bport
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
36
7.4 Enter BTS site manager attributes Here, the attributes of the BTS_Site_Manager (BTSM) are set. The BTS Site Manager represents the O&M functionality related to a site and not to any specific BTS. A site is a logical grouping of one or more BTS (maximum 3) at a single physical location with common management needs. This configuration has to match with the related LPDLM-Object in the BSC. Note: the LAPD signaling on BTSM must terminate on Bport 0.
ABISTIME This attribute provides the time-of-day time of the BTSE. This attribute functions as a reference for all time stamp activities in the BTSE. Validity range: Year 1000-9999, Month 1-12, Day 1-31, Hour 0-23, Minute 0-59, Second 0-59.
ABISCH This attribute identifies the LAPD signaling Timeslot Number (and Subslot Number) allocated on the Abis-interface. Validity range: Timeslot_Number: 1-31 (PCM30), 1-24 (PCM24). Subslot Number: a (bits 1,2)=0, b (bits 3,4)=1, c (bits 5,6)=2, d (bits 7,8)=3, 64 kb/s signal.=0xFF.
TEI This attribute contains the Terminal Endpoint Identifier used in the layer2 addressing on the Abis-Interface for the logical O&M Link. The TEI is used to identify a specific point-to-point connection; each BTSM normally has one associated TEI. Validity range: 0-63.
BTS site manager attributes
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
37
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fig. 12 Set BTSM attributes
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
38
7.5 LAPDLE creation The object LAPDLE identifies the time slot on Abis used for communication between BSC and BTSE (as viewed from BTSE). Its counterpart on the BSC side is called "LPDLM". It is possible to configure up to 8 LAPDLE/LPDLM objects on two PCMB lines. Each line must carry at least one LAPDLE/LPDLM. The LAPD links are either all 64 kbit/s (3 and more TRX per BTSE) or all 16 kbit/s (max 2 TRX/BTSE), and either all satellited or all not satellited. Note: The object "LPDLM" on the BSC command tree indicates a time slot, which may carry both LPDLM and LPDLR type LAPD signaling. The settings for LAPDLE (BTSE commissioning) and LPDLM (BSC database) must be consistent.
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
39
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fig. 13 LAPDLE creation
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
40
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
41
8 Verify module state/status
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
42
Check the state and status of all the hardware modules created. For all successfully created objects the administrative state must be unlocked and the operational state must be enabled. From LMT, perform the following steps: LMT tree: MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE --> RACK -->
<module> Command: GET <Module Name> Name: NAME=RACK:0/<Module Name> Attributes: REQATTL=AST&OST Submit Command line: GET Module:NAME=RACK:0/<Module Name>, REQATTL=AST&OST;
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
43
9 Manually switch to phase three
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
44
For forced switchover to phase three a special command (connect BSC to BTSM command) must be entered at the LMT. LMT tree: MANAGED-ELEMENT --> BSS-FUNCTIONAL --> BTS --> BTSM Command: CONNBSC BTSM Name: NAME=BTSM:0 Attributes: none Submit Command line: CONNBSC BTSM:NAME=BTSM:0; To unlock the BTSM, perform the following steps from LMT: LMT tree: MANAGED-ELEMENT --> BSS-FUNCTIONAL --> BTSM --> Command: UNLOCK BTSM Name: NAME=BTSM:0 Attributes: none Submit Command line: UNLOCK BTSM:NAME=BTSM:0;
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
45
10 Generate backup files
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
46
In order to save the latest BTSplus configuration, a backup copy is generated and stored on site, e.g. on a floppy disk. By default; all files necessary to perform the backup and restore procedure are stored in subdirectory C:/Siemens/LMTxxx/BkBts/BTSplusyy on the LMT hard disk (where yy can be 16, 17 or 18 to indicate BR7.0, BR8.0 or BR9.0 SW version used in the BTS, respectively). BTSplus backup files are generated in phase 2 or 3 by performing the following steps:
• start BTS Backup tool (from LMT Evolution , menu View)
• Select the command GET (button or file menu) The objects and attributes of the BTSE are stored in up to 8 TXT files (e.g. GETBPORP) describing the current configuration. For the restoring these files are converted into script files (e.g. script1p.lmt) generated. These script files should be backed up on CD and left in the BTSE so that you can use them in case of a COBA failure.
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
47
Fig. 14 Start BKBTS tool
Fig. 15 Folder for backup files
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
48
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
49
11 BTSE restart verification
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
50
Power off and on the BTSE to ensure that the BTSE recovers without errors in case of a total loss of power.
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
51
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BBSIG
BBSIG
CB FP
AIR FILTER
ACOM
ACOM
ACOM
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
RXMUC
PA
TPU
PA
TPU
PA
TPU
PA
TPU
PA
TPU
PA
TPU
PA
TPU
DCPA
DCTPU
DCTPU
DCPA
DCPA
DCTPU
DCTPU
DCPA
DCPA
DCTPU
DCPA
DCTPU
GPSU
BBSIG
BBSIG
BBSIG
BBSIG
MCLK
CCTRL
LI
ALCO
FANS
Fig. 16 Restart verification
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
52
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
53
12 Functional structure
RXAMCO1
TPU 0
TPU 1
DCTPU0
DCTPU1
DCPA0
DCPA1
FAN 0
BackupBatteryGPSU 0
PDB
...Diversity
-48 V 230 V AC
ALCO 0
ALCO 0
MCUX 0
BBSIG 0
MSG 0
LI 0
LMT
Site Inputs
Site Outputs
BU
S 1
BU
S 2
Abis
RXAMCO1
Cell 0
DUKITfx (2:1)
PA 1
PA 0
DUKIT0
1
0
1
1
0
0
0
DCBreaker AC/DC 0
Fig. 17 Functional blocks of a 2 carrier BTSE (BS20) with DUKIT (configured for 1 cell with 2 carriers)
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
54
TPU 0
TPU 1
DCTPU 0
DCTPU 1
DCPA 1
DCPA 1
FAN 0
GPSU 0 BackupBattery
HOSTEXCHANGE HOSTER
AC/DC 0
AC/DC 1
PDB
ALCO 0
CCTRL 0
MCLK 0
BBSIG 1
MCLK 0
LI 0
LMT
Site Inputs
Site Outputs
BU
S 2
BU
S 1
LinkEquipment
Abis
Cell 0
DUKITfx (2:1)
RXAMCO0
RXAMCO1
230 V AC
...Diversity
-48 VDC
Breaker
PA 0
PA 1
DUKIT 0
0
1
0
1
0
0
1
Fig. 18 Functional blocks of a 2 carrier BTSE (BS21E) with DUKIT (configured for 1 cell with 2 carriers)
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
55
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DUCOMT
PA TPU
RXAMCO
RXAMCO
FCB 0...Diversity
BU
S 1
LI
CCLK
CCTRL
ALCO
BBSIG
Abis
BU
S 2
LMT
FP230V AC
ACMDC
Fig. 19 Functional blocks of a 2 carrier BTSE (BS22) with DUCOMT (configured for 1 cell with 2 carriers)
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
56
HYCOMPA TPU BBSIG
CCLK
CCTRL
ALCO
GPSU FP-48 V DCDCTPUDCPA
FAN 2
FAN 1
FAN 0
RXMUCORXAMOD
RXMUCORXAMOD
LMT
Site Inputs
Site Outputs
LI
Abis(OVPT, NTPM or µWave)
...Diversity
BU
S 2
BUS
1
Fig. 20 Functional blocks of a 6 carrier BTSE with HYCOM (configured for 1 cell with 4 carriers)
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
57
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DLCOM
RXAMCO
RXAMCO
DCPA DCTPUFAN 2
FAN 1
FAN 0
...Diversity ALCO
CCLK
GPSU FP
LMT
SiteInput
SiteOutput
-48 V DC
BUS
2
Abis
BBSIG
LI
CCTRL
TPUPA
BU
S 1
Fig. 21 Functional blocks of a 6 carrier BTSE with DUCOM (configured for 1 cell with 4 carriers)
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
58
FICOM
RXAMCORXFIL
RXAMCORXFIL
RXMUCO
RXMUCO
DCPA DCTPU
GPSU FP
ALCO
CCTRL
CCLK
LITPUPA
BU
S 1
BU
S 2
BBSIG
-48 V DC
LMT
Site Inputs
Site Outputs
...Diversity
FAN 2
FAN 1
FAN 0
Abis
Fig. 22 Functional blocks of a 6 carrier BTSE with FICOM (configured for 1 cell with 6 carriers)
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
59
13 Exercises
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
60
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
61
Exercise 1 Commission a BTSE in the Training Center. Remember, in the Training Center you will find an already running system. Therefore, before you follow chapters 1, 2 and 3 of this register, you have to do some previous work and to add some additional steps in order to bring the system down. Previous work to be done:
• Write down the name of the software load header file and the software load header itself for the BTSE. Take a look to the subdirectory containing the BTSE software on your LMT hard disk. Compare it with the information in the BSC database.
• With which command can you display the currently running software on the BTSE?
• Find out the configuration (star, loop or multidrop chain) of the BTSE.
• Find out the TEI and SalesUniqueName of the BTSE.
• Find out which timeslot is used for LAPD signaling.
• Find out whether a 64 kbit/s or a 16 kbit/s timeslot is used for LAPD signaling.
• Find out whether or not CRC is used.
• Find out whether or not environmental alarms have to be equipped. Usually „find out“ means: ask your boss or your colleagues. Since we have a running system in the Training Center you can also interrogate the system itself. Therefore use the following commands from LMT: LMT tree: MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE Command: GET BTSE Name: NAME=BTSE:0 Attributes: REQATTL= SWLDINT, SWLDSAF, SWLDST; Submit Command line: GET BTSE SWL: NAME=BTSE:0, REQATTL= SWLDINT, SWLDSAF, SWLDST;
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
62
LMT tree: MANAGED-ELEMENT --> BSS.FUNCTIONAL --> BTSM Command: GET BTSM Name: NAME=BTSM:0 Attributes: REQATTL= ABISCH, TEI; Submit Command line: GET BTSM: NAME=BTSM:0, REQATTL= ABISCH, TEI; LMT tree: MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE --> RACK -->
LI Command: GET LI Name: NAME=RACK:0/LI:0 Attributes: REQATTL= BERT, LCONF, ALRMT1/2/3, ALRMCOUNTER; Submit Command line: GET LI: NAME=RACK:0/LI:0, REQATTL= REQATTL= BERT, LCONF, ALRMT1/2/3, ALRMCOUNTER;
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
63
Exercise 2 Additional steps in order to bring the system down
I) Lock BTSM and disconnect (by command) BTSE from BSC From LMT, enter the following commands: LMT tree: MANAGED-ELEMENT --> BSS-FUNCTIONAL --> BTSM Command: LOCK BTSM Name: NAME=BTSM:0 Attributes: none Submit Command line: LOCK BTSM: NAME=BTSM:0; LMT tree: MANAGED-ELEMENT --> BSS-FUNCTIONAL --> BTSM Command: DISCBSC Name: NAME=BTSM:0; Attributes: none Submit Command line: DISCBSC BTSM: NAME=BTSM:0; BTSE switches from phase 3 to phase 2. A new Logon is necessary.
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
64
BTSE commissioning Siemens
MN1784EU12MN_0001 © 2002 Siemens AG
65
Exercise 3 I) Format CCTRL Flash EPROM
From LMT, perform the following steps: LMT tree: MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE Command: FORMAT BTSE FLASH Name: NAME=BTSE:0; Attributes: none Submit Command line: FORMAT BTSE FLASH: NAME=BTSE:0; This procedure requires about 1-2 minutes. The BTSE switches from phase 2 to phase 1. A new Logon is necessary.
II) Power off the BTSE Switch off all fuses. Follow now chapters 1, 2 and 3 of this register to commission the BTSE.
Siemens BTSE commissioning
MN1784EU12MN_0001© 2002 Siemens AG
66