1 Introduction to the Recommendations and their Application Principles 1.1 National and International Regulations for Piling Works (1) Since the implementation of DIN EN 1997-1:2009-09: Eurocode 7: Geo- technical Design - Part I: General Rules, pile analysis and design in Germany is governed by ^ - Section 7 of Eurocode EC 7-1 (Eurocode 7), in conjunction with - DIN 1054:2010-12: Subsoil - Verification of the Safety of Earthworks and Foundations - Supplementary Rules to the German version DIN EN 1997- I, and the - National Annex to EC 7-1, namely DIN EN 1997-1/NA:2010-12: National Annex - Nationally Determined Parameters - Eurocode 7: Geotechnical Design - Part I: General Rules. These three coordinated documents are summarised in the German Eurocode 7 Handbook, Volume 1 [44]. Note: In case amendments or corrections are made to the standards included in the German Eurocode 7 Handbook, Volume I [44], the changes must be adopted even when not yet incorporated in [44]. (2) In addition, the individual pile systems are governed by the following execution standards: DIN E N 1536: Execution of special geotechnical works - Bored piles. DIN SPEC 18140: Supplementary provisions to DIN EN 1536. DIN EN 12699: Execution of special geotechnical works - Displacement piles. DIN SPEC 18538: Supplementary provisions to DIN EN 12699. DIN E N 14199: Execution of special geotechnical works - Micropiles. DIN SPEC 18539: Supplementary provisions to DIN E N 14199. DIN E N 12794: Precast concrete products - Foundation piles. DIN E N 1993-5: Design of steel structures - Part 5: Piling. (3) Because diaphragm wall elements are often employed in the same way as pile foundations, the respective execution standard must also be consider- ed: DIN E N 1538: Execution of special geotechnical works - Diaphragm walls in conjunction with: DIN 4126: Stability analysis of diaphragm walls. Recommendaiions on Piling - EA PJahle. EditoTs: German Geoiechnieal Society (Deiilsche Geselhchafi fiir Gealechnik e. V.) e 20U Emsl & Sohn GmbH & Co. KG- Published 2014 by ErasI & Sohn Gmbli & Co. KG. 1

Upload: hakhanh

Post on 01-Feb-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1 Introduction to the Recommendations and their ...ftc.lib.tsinghua.edu.cn/files/books/ED5/description/... · 1 Introduction to the Recommendations and their Application Principles

1 Introduction to the Recommendations and their Application Principles

1.1 National and International Regulations for Piling Works

(1) Since the implementation o f D I N E N 1997-1:2009-09: Eurocode 7: Geo­technical Design - Part I: General Rules, pile analysis and design in Germany is governed by ^

- Section 7 o f Eurocode E C 7-1 (Eurocode 7), in conjunction with - D I N 1054:2010-12: Subsoil - Verification o f the Safety o f Earthworks and

Foundations - Supplementary Rules to the German version D I N E N 1997-I, and the

- National Annex to E C 7-1, namely D I N E N 1997-1/NA:2010-12: National Annex - Nationally Determined Parameters - Eurocode 7: Geotechnical Design - Part I: General Rules.

These three coordinated documents are summarised in the German Eurocode 7 Handbook, Volume 1 [44].

Note: In case amendments or corrections are made to the standards included in the German Eurocode 7 Handbook, Volume I [44], the changes must be adopted even when not yet incorporated in [44].

(2) In addition, the individual pile systems are governed by the fol lowing execution standards:

DIN E N 1536: Execution o f special geotechnical works - Bored piles. DIN S P E C 18140: Supplementary provisions to D I N E N 1536. DIN E N 12699: Execution o f special geotechnical works - Displacement

piles. DIN S P E C 18538: Supplementary provisions to D I N E N 12699. DIN E N 14199: Execution o f special geotechnical works - Micropi les . DIN S P E C 18539: Supplementary provisions to D I N E N 14199. DIN E N 12794: Precast concrete products - Foundation piles. DIN E N 1993-5: Design o f steel structures - Part 5: P i l ing .

(3) Because diaphragm wal l elements are often employed in the same way as pile foundations, the respective execution standard must also be consider­ed:

DIN E N 1538: Execution o f special geotechnical works - Diaphragm walls

in conjunction with:

DIN 4126: Stability analysis o f diaphragm walls.

Recommendaiions on Piling - EA PJahle. EditoTs: German Geoiechnieal Society (Deiilsche Geselhchafi fiir Gealechnik e. V.) e 20U Emsl & Sohn GmbH & Co. KG- Published 2014 by ErasI & Sohn Gmbli & Co. KG.

1

Page 2: 1 Introduction to the Recommendations and their ...ftc.lib.tsinghua.edu.cn/files/books/ED5/description/... · 1 Introduction to the Recommendations and their Application Principles

T (4) In addition, several ISO standards are being compiled for a number o f special topics relating to piles. They are however not l ikely to be implemented as building regulations in Germany. Currently, these include:

D I N E N ISO 22477-1: Geotechnical investigation and testing - Testing o f geotechnical structures - Part 1: Pile load test by sta­tic axially loaded compression.

On a national basis, the regulations in Section 9 should be adopted for static pile testing.

1.2 Types of Analysis and Limit States using the Partial Safety Factor Approach

1.2.1 New standards generation and their application to pile foundations

(1) B y European Commission decision national building design and execution standards either already have been or w i l l in future be replaced by European standards. Actually numerous European standards have been published for geotechnical design and execution o f special geotechnical works.

(2) The European standards governing pile execution are listed in 1.1.

(3) Analysis and design o f pile foundations is dealt with in the European stan­dard D I N E N 1997-1: Geotechnical Design (Eurocode 7) in conjunction with D I N 1054 and D I N E N 1 9 9 7 - l / N A , see 1.1. These three standards were im­plemented by the German Bui ld ing Authorities for use in Germany as o f 01.07.2012.

(4) Unt i l the time o f implementation o f the Eurocodes as binding building regulations a new generation o f national standards using the partial safety factor approach served as temporary solution for al l fields o f structural engi­neering. The following standards in particular represented the governing stan­dards for pile foundations:

D I N 1055-100:2001-03: Basis o f structural design: D I N 1054:2005-01:

D I N 18800:1990-11: D I N 1045-2:2001-07:

Verification o f the safety o f earthworks and founda­tions; Steel structures and; Concrete, reinforced and prestressed concrete struc­tures - Part 2: Concrete - Specification, properties,

^ production and conformity - Appl icat ion rules for D I N E N 206-1.

(5) These Recommendations on Pi l ing (EA-Pfahle) are based on the standards listed in 1.1 above and. for design in particular, on Eurocode E C 7-1, in con­junction with D I N 1054 and the N A as stipulated in 1.1 (1).

1.2.2 Actions, effects and re

(1) The partial safety factor appro used to specify the requisite safety contrast to this, with the implemei technical standards generation folk common global safety factors into and partial safety factors for resista

(2) The basis for stability analyse: for actions and resistances. The ch "k", is a value o f which the specific or fallen short o f during the refei design working life o f the siructi Characterisfic values are generally analyses or empiricism.

(3) If the "intemar" or "external" fects at the pile head or at given de|

- A s action effects, e.g. normal fc - A s stresses, e.g. compression, t

valent stress.

In addition, further effects o f actior

- A s dynamic or cyclic loads; - A s change to the structural elen - A s change in the position o f iso

settlement, rotation.

(4) The cross-section and the inten ing factors in the design of individi applied for this purpose.

(5) The characteristic values of i factors, those o f resistances are di designated as design values o f elTe acterised by the index "d" . For s distinguished, also see 1.2.3, 1.2.4 i

(6) In addition to actions, design for pile analyses, similar to other s loading cases E C 1, L C 2 and L C D I N 1054:2005-01, have been con' ses after DiN EN 1997-1 (EC 7-1) as fol lows:

- B S - P (persistent (design) situati - B S - T (transient (design) situatic - B S - A (accidental (design) situat

2

Page 3: 1 Introduction to the Recommendations and their ...ftc.lib.tsinghua.edu.cn/files/books/ED5/description/... · 1 Introduction to the Recommendations and their Application Principles

1.2.2 Actions, effects and resistances

(1) The partial safety factor approach has its origins in probability theory, as used to specify the requisite safety factors from a probabihstic perspective. In contrast to this, with the implementation o f D I N 1054:2005-01, the new geo­technical standards generation follows a more pragmatic split o f the previously common global safety factors into partial safety factors for actions or effects, and partial safety factors for resistances.

(2) The basis for stability analyses is represented by the characteristic values for actions and resistances. The characteristic value, represented by the index "k", is a value o f which the specified probability is assumed not to be exceeded or fallen short of during the reference period, taking into consideration the design working life o f the structure or the corresponding design situation. Characteristic values are generally specified based on testing, measurements, analyses or empiricism.

(3) If the ' i n l ema l " or "external" pile capacity needs to be analysed, the ef­fects at the pile head or at given depths are required: ^ |

- As action effects, e.g. normal force, shear force, bending moment; - As stresses, e.g. compression, tension, bending stress, shear stress or equi­

valent stress.

In addition, further effects o f actions can occur:

- As dynamic or cyclic loads; - As change to the structural element, e.g. strain, deformation or crack width; - As change in the position o f isolated piles or pile groups, e.g. displacement,

settlement, rotation.

(4) The cross-section and the internal resistance o f the material arc the govern­ing factors in the design o f individual components. Specific standards are to be applied for this purpose.

(5) The characteristic values o f the effects are multiplied by partial safety factors, those o f resistances are divided. The values acquired in this way are designated as design values o f effects or resistances respectively and are char­acterised by the index "d" . For stability analyses, different l imit states are distinguished, also see 1.2.3, 1.2.4 and3 .1 . ! (4).

(6) In addition to actions, design situations are also taken into consideration for pile analyses, similar to other structural elements. To this end the previous loading cases L C 1, L C 2 and L C 3, adopted for use in analysis according to DIN 1054:2005-01, have been converted to design situations for use in analy­ses after DIN E N 1997-1 (EC 7-1) and D I N 1054:2010-12, and D I N E N 1990 as follows:

- BS-P (persistent (design) situation); - BS-T (transient (design) situation) and; - BS-A (accidental (design) situation).

3

Page 4: 1 Introduction to the Recommendations and their ...ftc.lib.tsinghua.edu.cn/files/books/ED5/description/... · 1 Introduction to the Recommendations and their Application Principles

In addition, there is the seismic design situation B S - E . More detailed informa­tion is given in the E C 7-1 German Handbook [44] and in [133].

1.2.3 Limit states and national application of the EC 7-1 German Handbook

(1) The term "Hmit slate" is used with two different meanings:

a) In soil mechanics, the state o f the soil in which displacements o f individual soil particles against each other are so great that the mobilisable shear strength achieves its greatest values in either the entire soil mass, or at least in the region o f a failure plane, is known as the " l imi t state o f plastic f low". It cannot become greater even i f more movement occurs, but could become smaller. The l imit state o f plastic flow characterises the active earth pres­sure, passive earth pressure, bearing capacity, "external" pile failure, slope stability, and global stability.

b) A second limit state in the sense o f the new safety factor approach is a state o f the load-bearing structure where, i f exceeded, the design requirements are no longer fulfilled. j

(2) The fol lowing limit states are differentiated using the partial safety factor approach:

a) The ultimate limit state is a condition o f the structure which , i f exceeded, immediately leads to a calculated collapse or another fonn o f failure. It is referred to as " U L S " in E C 7 and D I N 1054. Further distinguishing is de­scribed in (5).

b) The serviceability limit state is a condition o f the structure which, i f ex­ceeded, no longer fulfils the conditions specified for its use. It is referred to as " S L S " in E C 7 and D I N 1054.

(3) For ultimate limit state analysis ( U L S ) , Eurocode E C 7-1 provides three options. With one exception (see (6) and (9)), the supplementary rules o f D I N 1054 for use in Gemiany are based on Analysis Method 2 o f E C 7-1. The partial safety factors are applied to both, effects and resistances. To differenti­ate this from the other permitted scenario, in which the partial safety factors are not applied to the effects but to the actions, this procedure is designated as Analysis Method 2* in [133], also sec the E C 7-1 Handbook [44].

(4) The National Annex to E C 7-1 and D I N 1054 represent a formal l ink be­tween E C 7-1 and national German standards, see E C 7-1 German Handbook [44]. In D I N 1054 and the National Annex it is stated which o f the possible analysis methods and partial safety factors are applicable in the respective national domains. In addition, the applicable, supplementary national codes may also be given. The supplementary national codes may not contradict E C 7-1. Moreover, the National Annex may not repeat information already given in E C 7-1.

(5) Eurocode E C 7-1 distinguish^ the ultimate limit state ( U L S ) :

a) E Q U : Loss o f equilibrium o f t l ground. The designation is deri'

b) S T R : Internal failure or very lai tural elements, where the stren The designation is derived from

c) G E O : Failure or very large di where the strength o f the soil c tion is derived from "geotcchni(

d) U P L : Loss o f equilibrium of tht water pressure. The designation

e) H Y D : Hydraulic ground failure caused by a fiow gradient. The ure".

(6) In the terminology o f the E C state is sub-divided into G E O - 2 ant

a) G E O - 2 : Failure or very large with the calculation o f the actio ising shear strength for passivi bearing resistance, and when ai chored retaining walls, and fo foundations. The G E O - 2 limit 2*. see (3), as outlined in the E(

b) G E O - 3 : Failure or very large with the analysis o f the over strength for analysis of the saf and, nonnally, when analysing : sideration o f structural elemeni state calculation follows Analys man Handbook [44].

(7) The E Q U , U P L and H Y D liir, br ium. These include:

a) Safety analysis against overtumi b) Safety analysis against buoyan

( U P L ) ; c) Safety analysis against hydraulit

(8) The limit states E Q U , U P L an. tanees.

The governing l imit state condition

4

Page 5: 1 Introduction to the Recommendations and their ...ftc.lib.tsinghua.edu.cn/files/books/ED5/description/... · 1 Introduction to the Recommendations and their Application Principles

(5) Eurocode E C 7-1 distinguishes the fol lowing subordinate l imit states o f the uhimate limit state ( U L S ) :

a) EQU: Loss of equilibrium o f the structure, regarded as a rigid body, or the ground. The designation is derived from "equil ibrium".

b) STR: Internal failure or very large deformations o f the structure or its struc­tural elements, where the strength o f the materials governs the resistance. The designation is derived from "structural failure".

c) GEO: Eailure or very large deformation o f the structure or the ground, where the strength of the soil or rock governs the resistance. The designa­tion is derived from "geotechnical failure".

d) UPL: Loss of equilibrium o f the structure or the ground due to buoyancy or water pressure. The designation is derived from "uplift".

e) H Y D : Hydraulic ground failure, internal erosion o f or piping in the ground, caused by a flow gradient. The designation is derived from "hydraulic fail­ure", i

(6) In the terminology o f the E C 7-1 German Handbook [44] the G E O limit state is sub-divided into G E O - 2 and G E O - 3 :

a) GEO-2: Failure or very large deformation o f the ground in conjunction with the calculation o f the action effects and the dimensions, i.e. when util­ising shear strength for passive earth pressure, for sliding resistance and bearing resistance, and when analysing deep slide surface stability for an­chored retaining walls, and for base resistance and skin friction o f pile foundations. The G E O - 2 limit state calculation follows Analysis Method 2*, see (3), as outlined in the E C 7-1 German Handbook [44].

b) GEO-3: Failure or very large deformation o f the ground in conjunction with the analysis o f the overall stability, i.e. when util ising the shear strength for analysis o f the safety against slope failure and global failure and. normally, when analysing slope stabilisation measures, including con­sideration of structural elements, e.g. anchors or piles. The G E O - 3 limit state calculation follows Analysis Method 3 as outlined in the E C 7-1 Ger­man Handbook [44].

(7) The E Q U , U P L and H Y D limit states describe the loss o f static equili­brium. These include:

a) Safety analysis against overturning ( E Q U ) ; b) Safety analysis against buoyancy or uplift, e.g. o f a tension pile group

(UPL); c) Safety analysis against hydraulic heave ( H Y D ) .

(8) The limit states E Q U , U P L and H Y D involve actions only, but no resis­tances.

The governing limit state condition is:

F. = F k Y d . ^ G , . y , , = G , ; , (1.1)

5

Page 6: 1 Introduction to the Recommendations and their ...ftc.lib.tsinghua.edu.cn/files/books/ED5/description/... · 1 Introduction to the Recommendations and their Application Principles

i.e. the destabilising actions F^, multiplied by the partial safety factor yj^, > 1,0, may only be as large as the stabilising action 0^, multiplied by the partial safe­ty factor Ysib < 1,0.

(9) The G E O - 2 limit state describes the failure o f structures and structural elements or the failure o f the ground. It includes:

a) Analysis o f the bearing capacity o f structures and structural elements sub­jected to loads from the ground or supported by the ground;

b) Analysis o f the bearing capacity of the ground to demonstrate that it is not exceeded, e.g. passive earth pressure, bearing resistance, pile resistance or sliding resistance.

The analysis to demonstrate that the bearing capacity o f the ground is not ex­ceeded is performed exactly as for any other construction material. The limit state condition is always the governing condition:

E a - E , - Y , < R , / Y , = R , ; (1.2)

i.e. the characteristic effect Et̂ , multiplied by the partial safety factor yn for actions or strains, may only become as large as the characteristic resistance R^, divided by the partial safety factor yp.

(10) The G E O - 3 limit state is a peculiarity o f earthworks and ground engi­neering. It describes the loss o f overall stability. It includes:

a) Analysis o f safety against slope failure;

b) Analysis o f safety against global failure.

The limit state condition is always the governing condition:

Ed<Rd; (1.3) i.e. the design value E j o f the effects may only become as large as the design value o f the resistance R^. The geotechnical actions and resistances are deter­mined using the design values for shear strength:

tan^; = tan^;/y^ and c ; | - c ;^ /y^ and, respectively

tan^,,, = t a n ^ „ , / y ^ , and c, - c..

(1.4a)

(1.4b)

i.e. the friction tan 9 and the cohesion c are reduced from the outset using the partial safety factors y ,̂ and y^^.

(11) The serviceability l imit state (SLS) describes the state o f a structure or structural clement at which the conditions specified for its use are no longer met, but without loss o f Its bearing capacity. The analysis is based on the an­ticipated displacements and deformations being compatible with the purpose o f the structure.

1.2.4 Transitional regulation of the Reconnmendatic with the EC 7-1 Germa

(1) These Recommendations on I E C 7-1 German Handbook [44],

(2) A decisive difference between book [44] and D I N 1054:2005-01 i factors yi. (lower) and the correlat Overal l , however, yp and ^ result 1 side, l ike D I N 1054:2005-01, see [i

(3) The existing limit states to D l the E C 7-1 German Handbook [44]

a) The previous G Z I A limit statt restrictions to the E Q U , U P L z man Handbook [44].

b) The previous G Z I B limit statt restrictions to the S T R limit st£ as the "internal" pile capacity G E O - 2 limit state as in the E C wi th the "external" design of t pi le capacity.

c) The previous G Z I C limit state G E O - 3 limit state as in the E C with the analysis o f the ovei strength for analysis o f safety a,

1.3 Planning and Testing

(1) These Recommendations use t German Handbook [44] and the EC

(2) The designer should consult a possession o f the requisite knowlec ning.

(3) A geotechnical design report accordance with the E C 7-1 Genu; ence to the ground investigation re Handbook [45].

(4) Pi le foundations are classified Geotechnical Category G C 3. See for classification criteria.

(5) Where pile foundations are cl geotechnical expert with requisite

6

Page 7: 1 Introduction to the Recommendations and their ...ftc.lib.tsinghua.edu.cn/files/books/ED5/description/... · 1 Introduction to the Recommendations and their Application Principles

1.2.4 Transitional regulations for applying of the Recommendations on Piling in conjunction with the EC 7-1 German Handbook

(1) These Recommendations on Pi l ing are based on the provisions o f the EC 7-1 German Handbook [44].

(2) A decisive difference between the provisions o f the E C 7-1 German Hand­book [44] and D I N 1054:2005-01 is the specification o f different partial safety factors YP (lower) and the correlation factors c, (higher) for pile foundations. Overall, however, yp and £, result in a comparable magnitude on the resisting side, like D I N 1054:2005-0'l, see [59].

(3) The existing limit states to D I N 1054:2005-01 are replaced as follows in the E C 7-1 German Handbook [44]:

a) The previous G Z l A limit state to D I N 1054:2005-01 corresponds without restrictions to the E Q U , U P L and H Y D limit states as in the E C 7-1 Ger­man Handbook [44].

b) The previous G Z I B limit state to D I N 1054:2005-01 corresponds without restrictions to the STR limit state as in the E C 7-1 German Handbook [44] as the "internal" pile capacity (material strength). In addition, there is the G E O - 2 limit state as in the E C 7-1 German Handbook [44], in conjunction with the "external" design o f the foundation elements, e.g. the "external" pile capacity.

c) The previous G Z IC limit state as in D I N 1054:2005-01 corresponds to the GEO-3 limit state as in the E C 7-1 German Handbook [44], in conjunction with the analysis o f the overall stability, i.e. when util ising the shear strength for analysis o f safety against slope failure and global failure.

1.3 Planning and Testing Pile Foundations

(1) These Recommendations use the terms "designer" (planner) as the E C 7-1 German Handbook [44] and the E C 7-2 German Handbook [45].

(2) The designer should consult a specialist pile foundation planner i f not in possession of the requisite knowledge and experience for pile foundation plan­ning.

(3) A geotechnical design report must be compiled for pile foundations in accordance with the E C 7-1 German Handbook [44], which must make refer­ence to the ground investigation report in accordance with the E C 7-2 German Handbook [45].

(4) Pile foundations are classified as either Geotechnical Category G C 2 or Geotechnical Category G C 3. See 3.2 and the E C 7-1 German Handbook [44] for classification criteria.

(5) Where pile foundations are classified as Geotechnical Category G C 3, a geotechnical expert with requisite experience must be consulted during the

7

Page 8: 1 Introduction to the Recommendations and their ...ftc.lib.tsinghua.edu.cn/files/books/ED5/description/... · 1 Introduction to the Recommendations and their Application Principles

structural engineering appraisal o f the ground investigation report and the geotechnical design report. In particular, the geotechnical expert should verify the ground mode!, the soil parameters and the design approach, and, in agree­ment with the independent verifier, should carry out comparative analyses.

(6) The execution o f pile foundations should be supervised by a specialist planner or a geotechnical expert with the requisite experience and specialist knowledge o f pile foundations. Where pile foundations arc classified as Geo­technical Category G C 3. the expert mentioned in (5) must also be consulted to check the detailed design and to supervise the pile execution works.

^ 1 I

1,

f