Retail Plug-Load Portfolio (RPP) Program

Proposed Basic Tier Product UESs

EM&V and Residential Program TeamsSeptember 24, 2015

Residential PLA Program

2

Retail Plug-Load Portfolio (RPP)Meeting Agenda

Topic Presenters

UEC/UES: Product Specific Calculation Methodologies and Values

Jia Huang, PG&E;Andrea Salazar, EMI Consulting

Residential PLA Program

3

Critical Questions for CalTF Input

Are the assumptions and proposed methods for estimating the UESs reasonable?

Does the CalTF approve the proposed values for Basic Tier UESs?

Residential PLA Program

4RPP Approach to Calculating UECs:Decision Tree

Residential PLA Program

5

Definitions

Unit energy consumption (UEC) is the average estimated annual electricity usage (kWh) per unit for a specific product or device.

Unit energy savings (UES) is the average estimated annual electricity savings (kWh) per unit for a specific product or device.

Coincidence Factor (CF) is the fraction of rated load that is actually connected during peak demand periods.

Unit Demand Reduction (UDR) is the average estimated demand reduction (kW) per unit for a specific product or device.

Residential PLA Program

6

Product ClassificationsProduct RPP Product Classes

ENERGY STAR Air Cleaners

< 100 CADR

100 - 150 CADR

> 150 CADR

ENERGY STAR Freezers

Upright with manual defrost, < 13 cu. ft.

Upright with manual defrost, 13 – 16 cu. ft.

Upright with manual defrost, > 16 cu. ft.

Upright with automatic defrost, < 13 cu. ft.

Upright with automatic defrost, 13 – 16 cu. ft.

Upright with automatic defrost, > 16 cu. ft.

Chest with manual defrost, < 13 cu. ft.

Chest with manual defrost, 13 – 16 cu. ft.

Chest with manual defrost, > 16 cu. ft.

Chest with automatic defrost, < 13 cu. ft.

Chest with automatic defrost, 13 – 16 cu. ft.

Chest with automatic defrost, > 16 cu. ft.

Residential PLA Program

7

Product Classifications (cont.)Product RPP Product Classes

ENERGY STAR + 50% Soundbars

ENERGY STAR Electric Clothes Dryers

Ventless, Standard, Any Voltage

Ventless, Compact, 120 V

Ventless, Compact, 240 V

Vented, Standard, Any Voltage

Vented, Compact, 120 V

Vented, Compact, 240 V

ENERGY STAR Gas Clothes Dryers

ENERGY STAR Room ACs

With louvered sides, < 6000 Btu/h

With louvered sides, 6000 - 7999 Btu/h

With louvered sides, 8000 - 13999 Btu/h

With louvered sides, 14000 - 19999 Btu/h

With louvered sides, 20000 - 27999 Btu/h

With louvered sides, ≥ 28000 Btu/h

Without louvered sides, < 6000 Btu/h

Without louvered sides, 6000 – 7999 Btu/h

Without louvered sides, 8000 – 10999 Btu/h

Residential PLA Program

8

Product Classifications (cont.)

Product RPP Product Classes

ENERGY STAR Room ACs

Without louvered sides, 11000 – 13999 Btu/h

Without louvered sides, 14000 – 19999 Btu/h

Without louvered sides, ≥ 20000 Btu/h

With heat pump, with louvered sides < 20000 Btu/h

With heat pump, with louvered sides ≥ 20000 Btu/h

With heat pump, without louvered sides < 14000 Btu/h

With heat pump, without louvered sides ≥ 14000 Btu/h

Casement-only

Casement-slider

Residential PLA Program

9UES Approaches, Data Needs, and Data Sources

Room Air Conditioner

sSoundbars Freezers Room Air

Cleaners

Electric Clothes Dryers

Gas Clothes Dryers

UES Approach

Non-DEER Measure

Level

Non-DEER Measure

LevelDEER

Non-DEER Measure

Level

Non-DEER Measure

Level

Non-DEER Measure

Level

Data Needs

Capacity, configuration, CEER, HOU

Power usage by mode, HOU by mode

NA

Capacity, efficiency,

HOU by mode, power

usage by mode

Load size, configuration, number of cycles per

year, combined

energy factor

Load size, configuration, number of cycles per

year, combined

energy factor

Data Sources

ENERGY STAR

criteria, federal

minimum standards,

retailer sales data

Secondary research DEER

ENERGY STAR

savings calculator,

AHAM’s 2004

Analysis of Energy

Efficiency of Room Air Cleaners,

retailer sales data

DOE Notice of Proposed Rulemaking,

DOE Technical Support

Document, ENERGY

STAR criteria, federal

minimum standards

DOE Notice of Proposed Rulemaking,

DOE Technical Support

Document, ENERGY

STAR criteria, federal

minimum standards

Residential PLA Program

10

Freezers

Residential PLA Program

11

Freezers: DEER Approach Product Type Size kWh/

yeartherms/

year kW/year

Upright freezer withmanual defrost

< 13 cu. ft. 22.1 -0.650 0.00398

13 – 16 cu. ft. 23.8 -0.699 0.00428

> 16 cu. ft. 25.5 -0.750 0.00459

Upright freezer withautomatic defrost

< 13 cu. ft. 28.0 -0.824 0.0050513 – 16 cu.

ft. 30.6 -0.900 0.00552

> 16 cu. ft. 33.2 -0.977 0.00598

Chest freezer with manual defrost

< 13 cu. ft. 16.3 -0.480 0.0029413 – 16 cu.

ft. 18.6 -0.546 0.00334

> 16 cu. ft. 20.7 -0.610 0.00373

Chest freezer with automatic defrost

< 13 cu. ft. 22.6 -0.666 0.0040813 – 16 cu.

ft. 25.8 -0.758 0.00464

> 16 cu. ft. 28.8 -0.847 0.00519

Residential PLA Program

12

Clothes Dryers

Residential PLA Program

13

Clothes Dryers: Non-DEER Measure Level Approach to Calculating UESs

Residential PLA Program

14

Clothes Dryers: Non-DEER Measure Level Approach to Calculating UESs

CEFbase-case

Federal minimum standard

CEFmeasure-case

ENERGY STAR spec

Residential PLA Program

15

Clothes Dryers: Non-DEER Measure Level Approach to Calculating UDRs

Residential PLA Program

16

Clothes Dryers: Non-DEER Measure Level Approach to Calculating UDRs

SCE multifamily laundry facility metering study

2011 DOE Technical Support Document for

Residential Clothes Dryers

2014 DOE Technical Support Document for Commercial Clothes

Washers

Residential PLA Program

17

Clothes Dryers: UESs & UDRs

 Product Type Configuration kWh/year

therms/year kW/year

Ventless ElectricDryers

StandardAny Voltage 165.6 -3.9 0.09

Compact120 V 59.3 -1.4 0.04

Compact240 V 83.5 -2.0 0.05

Vented ElectricDryers

StandardAny Voltage 162.3 0.0 0.07

Compact120 V 58.1 0.0 0.03

Compact240 V 64.7 0.0 0.03

Gas Dryers NA 5.9 NA

Residential PLA Program

18

Room Air Cleaners

Residential PLA Program

19

Room Air Cleaners: Non-DEER Measure Level Approach to Calculating UESs

Residential PLA Program

20

Room Air Cleaners: Non-DEER Measure Level Approach to Calculating UESs

PI,Base-Case = 1.0 W

PI,Measure-Case = 0.6 W

ENERGY STAR savings calculator

TA = 8 hr/day 365 days/yr

TI = 16 hr/day 365 days/yr

2004 AHAM analysis

Sales weighted average capacity for each category determined using NEEA retailer sales data

EffBase-Case= 1 CADR/W

ENERGY STAR savings calculator

EffMeasure-Case= 2 CADR/W

ENERGY STAR spec

Residential PLA Program

21

Room Air Cleaners: Non-DEER Measure Level Approach to Calculating UDRs

Residential PLA Program

22

Room Air Cleaners: Non-DEER Measure Level Approach to Calculating UDRs

We assume no variation in the time of day people leave their air cleaners on. At 8 hours of operation a day, this results in a coincident demand factor of

0.33 (8/24).

Residential PLA Program

23

Room Air Cleaners: UESs & UDRs

 Product Type Size kWh/year

therms/year kW/year

Room Air Cleaners

< 100 CADR 107.1 -2.5 0.02

100 – 150 CADR 199.3 -4.7 0.03

> 150 CADR 360.7 -8.5 0.05

Residential PLA Program

24

Soundbars

Residential PLA Program

25

Soundbars: Tier Definition Due to high market penetration of ENERGY STAR soundbars, the

basic tier for soundbars is ENERGY STAR + 50% But what does + 50% mean?

Residential PLA Program

26

Soundbars: Tier Definition Due to high market penetration of ENERGY STAR soundbars, the

basic tier for soundbars is ENERGY STAR + 50% But what does + 50% mean? Looking at the ENERGY STAR spec:

• Products must have automatic power down (APD) functionality• APD must be enabled by default

• Psleep ≤ 1 W + sum(Pwake,i)

• Products with optimal disc players must have Pactive ≤ Pon + sum(Padd,i)

• Pidle ≤ 5 W + sum(Pidle allowance,i)

• ηamplifier ≥ 0.44 for 20 ≤ Pin < 100

• ηamplifier ≥ 0.55 for Pin ≥ 100

Residential PLA Program

27

Soundbars: Tier Definition Due to high market penetration of ENERGY STAR soundbars, the

basic tier for soundbars is ENERGY STAR + 50% But what does + 50% mean? Looking at the ENERGY STAR spec:

• Products must have automatic power down (APD) functionality• APD must be enabled by default

• Psleep ≤ 1 W + sum(Pwake,i)

• Products with optimal disc players must have Pactive ≤ Pon + sum(Padd,i)

• Pidle ≤ 5 W + sum(Pidle allowance,i)

• ηamplifier ≥ 0.44 for 20 ≤ Pin < 100

• ηamplifier ≥ 0.55 for Pin ≥ 100

Residential PLA Program

28

Soundbars: Tier Definition Due to high market penetration of ENERGY STAR soundbars, the

basic tier for soundbars is ENERGY STAR + 50% But what does + 50% mean? Looking at the ENERGY STAR spec:

• Products must have automatic power down (APD) functionality• APD must be enabled by default

• Psleep ≤ 1 W + sum(Pwake,i)

• Products with optimal disc players must have Pactive ≤ Pon + sum(Padd,i)

• Pidle ≤ 5 W + sum(Pidle allowance,i)

• ηamplifier ≥ 0.44 for 20 ≤ Pin < 100

• ηamplifier ≥ 0.55 for Pin ≥ 100

+ 50% means:• 50% lower Pidle and Psleep than ENERGY STAR base requirement AND

• 50% higher ηamplifier than ENERGY STAR base requirement

Residential PLA Program

29

Soundbars: Non-DEER Measure Level Approach to Calculating UESs

Residential PLA Program

30

Soundbars: Non-DEER Measure Level Approach to Calculating UESs

TA = 1580 hr/yr

TI= 730 hr/yr

Ts= 6450 hr/yr

2,000-person survey completed in 2007

Ps, Base-Case= 4 W

Fraunhofer 2014

Ps, Measure-Case= 1.4 W

EPA analysis

PA, Base-Case = 30 W

PI, Base-Case= 12 W

Fraunhofer 2014

PA, Measure-Case = 9 W

PI, Measure-Case= 8.4 W

EPA analysis

Residential PLA Program

31

Soundbars: Non-DEER Measure Level Approach to Calculating UDRs

Residential PLA Program

32

Soundbars: Non-DEER Measure Level Approach to Calculating UDRs

We use the coincident demand factor for televisions

from the Energy Division’s March 2013 Workpaper

Disposition on Energy Efficient Televisions as a proxy for

home audio products.

Residential PLA Program

33

Soundbars: UESs & UDRs

 Product Type kWh/year

therms/year kW/year

Soundbars 53.6 -1.3 0.0009

Residential PLA Program

34

Room ACs

Residential PLA Program

35Room ACs: Non-DEER Measure Level Approach to Calculating UESs

Residential PLA Program

36Room ACs: Non-DEER Measure Level Approach to Calculating UESs

FLHC = 356.7 hr/yr

DEER

ηBase-Case

Title 20

ηMeasure-Case

ENERGY STAR spec

Average capacity for each category determined using

webcrawler data from retailer websites

Residential PLA Program

37

Room ACs: DEER(ish) Approach to Calculating UDRs

DEER lists IOU-specific, split AC kW/kWh values for residential buildings by SEER category (SEER 15, 17, 18, 19, 20 and 21).

For this workpaper we use the average across all the SEER categories to estimate the kW/kWh value for room ACs.

Residential PLA Program

38

Room ACs: UESs & UDRs Product Type Size kWh/

yeartherms/

year kW/year

Room ACWith LouveredSides

< 6000 Btu/h 7.0 -3.9 0.01

6000 – 7999 Btu/h 8.8 -4.9 0.018000 – 13999 Btu/h 14.9 -8.3 0.02

14000 – 19999 Btu/h 23.5 -13.1 0.03

20000 – 27999 Btu/h 36.5 -20.4 0.05

≥ 28000 Btu/h 47.8 -26.7 0.06

Room AC Without Louvered Sides

< 6000 Btu/h 7.7 -4.3 0.01

6000 – 7999 Btu/h 9.7 -5.4 0.01

8000 – 10999 Btu/h 15.7 -8.7 0.0211000 – 13999

Btu/h 21.6 -12.1 0.03

14000 – 19999 Btu/h 23.9 -13.3 0.03

≥ 20000 Btu/h 37.0 -20.7 0.05

Residential PLA Program

39

Room ACs: UESs & UDRs (cont.) Product Type Size kWh/

yeartherms/

year kW/year

Room AC Heat Pump With Louvered Sides

< 20000 Btu/h 17.4 -9.7 0.02

≥ 20000 Btu/h 38.3 -21.4 0.05

Room AC Heat Pump Without Louvered Sides

< 14000 Btu/h 14.6 -8.1 0.02

≥ 14000 Btu/h 33.1 -18.5 0.04

Casement-Only Room AC 16.1 -9.0 0.02

Casement-Slider Room AC 12.8 -7.2 0.02

Residential PLA Program

40

Advanced Tiers Are Coming…

What we’re thinking: Air Cleaners: ENERGY STAR + 30% Soundbars: ENERGY STAR + 75% Freezers: ENERGY STAR + 5%

What you can expect: Presentation of technical definitions of ENERGY STAR

+ xx% for each product in October Same methodology will be used to determine UESs for

Advanced Tiers

Residential PLA Program

41

Action Items and Next Steps

41

Residential PLA Program

42Meeting Objectives/Critical Questions for CalTF Input

Are the assumptions and proposed methods for estimating UESs reasonable?

Does the CalTF approve the proposed values for UESs?

Residential PLA Program

43

Appendix: Data SourcesProduct Parameter Data Source Notes

Clothes Dryers

Cycles/yr

DOE Technical Support Document

Also considered NEEA field study of 46 homes. NEEA study and DOE TSD show comparable results. DOE TSD chosen for consistency with test procedure and ENERGY STAR calculation methodology.

Pounds/cycle

CEFBase-Case Federal Standard

CEFMeasure-Case ENERGY STAR Spec

Dryer cycle run timeavg PG&E/NEEA Lab Tests

CF SCE Multifamily Laundry Study

Residential PLA Program

44

Appendix: Data SourcesProduct Parameter Data Source Notes

Room Air Cleaners

Idle mode power drawENERGY STAR Savings Calculator

No other reliable sources foundEfficiencyBase-Case

EfficiencyMeasure-Case ENERGY STAR Spec

HOU by mode2004 AHAM Report to CEC: Analysis of Energy Efficiency of Room Air Cleaners

Other sources considered: 2004 PG&E report (data from AHAM 2003), ENERGY STAR Savings Calculator (source of data not documented) & 2010 ECW report - (small sample, size of units not documented).

Sales-weighted average capacity per category

NEEA retailer sales data

Residential PLA Program

45

Appendix: Data SourcesProduct Parameter Data Source Notes

Soundbars

Power draw by modeBase-Case

Fraunhofer 2014 report for the Consumer Electronics Association (CEA)

Most comprehensive study; built on and incorporated data from Roth and McKenney 2007 and Bensch et al 2010 (ECW)

Power draw by modeMeasure-Case

EPA analysis of ENERGY STAR Version 3.0 and Version 2.1 certified models

No other reliable sources found

HOU by modeRoth and McKenney 2007 report for the CEA

No other sources with significant sample size (> 1)

CF

Energy Division’s March 2013 Workpaper Disposition on Energy Efficient TVs

Residential PLA Program

46

Appendix: Data SourcesProduct Parameter Data Source Notes

Room ACs

Average capacity per subcategory

Retailer website web crawler data

FLHc DEER

ηBase-Case Title 20

ηMeasure-Case ENERGY STAR spec

kW/kWh DEER