• 1.Introduction -Basic concept & scan modes
• 2.Instrument -Cell design & fabrication of tips
• 3.Application -Biological and Electrochemical researches
• 4.Conclusion & References
Outline
![Page 3: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/3.jpg)
1.Introduction –basic conceptConstruction:
Position control
i-V control
In chemical solution system
Ultramicroelectrode
During the chemical reaction occurred at tip, a small current will be measured ! Signal: Current
Affect factor :1.Topography ---- Morphology2.Reaction type --- Reaction step3.Reaction rate --- Reaction constant
![Page 4: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/4.jpg)
1.Introduction –Scan modes– Feedback modeApproach curve
Far from substrate
Close to substrate
Tunnealing current
Full hindered
RneO
R oxidize to O
![Page 5: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/5.jpg)
1.Introduction –Scan modes– Feedback mode
Practical sample for conductive substrate
BCD
E
Approach curve for conductive substrate
![Page 6: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/6.jpg)
1.Introduction –Scan modes– Collection-Generate modes
1. TG/SC mode
1. SG/TC mode
BneA
Set tip and substrate in different potentials, compare the current difference between tip and substrate
Reaction constant !
Set tip and substrate in different potentials, scan the surface to measure the current
Hot spot !
![Page 7: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/7.jpg)
An illustration of the SECM instrument.
2.Instrument
![Page 8: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/8.jpg)
2.Instrument –Cell design
![Page 9: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/9.jpg)
Size limitation control by dithiol concentration or by the size of pulled capillary.
Diameter greater than 15–20 μm were very fragile and had a tendency to split open.
2.Instrument –Fabrication of tips
carbonization Immersion indithiol
![Page 10: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/10.jpg)
Charge-transfer at the liquid/liquid interface3.Application –Electrochemical researches
![Page 11: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/11.jpg)
Ion-transfer at the liquid/liquid interface
3.Application –Electrochemical researches
1
23
4
5
6
![Page 12: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/12.jpg)
A3+ + B → A2+ + B+
A2+ +e- → A3+
3.Application –Electrochemical researchesLateral mass transfer
A3+ → A2++e-
![Page 13: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/13.jpg)
Lateral charge transfer
determination of DCT
3.Application –Electrochemical researches
OsIIfilm + Ru(CN)6
3-aq ↔ OsIII
film + Ru(CN)64-
aq
![Page 14: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/14.jpg)
IMAGING MOLECULAR TRANSPORT ACROSS MEMBRANES
I. Tip Collection
II. Negative Feedback
II. Combined Mode
[]=100mM
[]=10mM
[]=100mM
[]=0mM
[]=10mM
[]=1mM
3.Application –Biological researches
![Page 15: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/15.jpg)
Generation/Collection Mode
Feedback Mode
3.Application –Biological researches
Constant Impedance Mode
![Page 16: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/16.jpg)
LOCALLY CONTROL REACTION3.Application –Biological researches
![Page 17: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/17.jpg)
4.Conclusion
1.SECM is suitable for observation of surface reaction in liquid system
2.Not only morphology, but also other properties can be measured by different modes in SECM
3.SECM can be applicated in microfabrication and biological sensoring.
Thanks for your attention!
![Page 18: 111226 表面分析分組報告(全組)](https://reader036.vdocuments.net/reader036/viewer/2022081419/55cabaf6bb61ebda608b45ab/html5/thumbnails/18.jpg)
4.References
1. Bard, A. J., & Mirkin, M. V. (2001). Scanning electrochemical microscopy. New York: Marcel Dekker
2. Phys. Chem. Chem. Phys., 2007, 9, 802–8233. Anal. Chem. 1998, 70, 1307 – 13114. J. Phys. Chem. 1995, 99, 16033-160425. J. Electroanal. Chem. 439 1997 137–1436. J. Phys. Chem. B 2001, 105, 11120-111307. J. Phys. Chem. B 2004, 108, 7219-7227