Detectors Indication Units Monitoring System INDUSTRIAL GAS DETECTION SYSTEM #199. Sanggal-ri, Kihung-up, Yongin, Kyungki-do, 449-900 Korea TEL:+82-31-280-5030 FAX:+82-31-283-2152 WEB:www.wisecontrol.com E-mail:[email protected] WISE CONTROL Inc. 248 N. Aberdeen Ave. Wayne PA 19087 Tel:USA 610 964 9976 Fax:USA 610 964 1190 For North and South America, please contact: Distributor WISE CONTROL reserves the right to amend the design and specifications of the instruments without notice. WISE GD2K02

Upload: dangkhue

Post on 26-Apr-2019

215 views

Category:

Documents


0 download

TRANSCRIPT

DetectorsIndication UnitsMonitoring System

INDUSTRIAL GAS DETECTION SYSTEM

#199. Sanggal-ri, Kihung-up, Yongin, Kyungki-do, 449-900Korea

TEL:+82-31-280-5030 FAX:+82-31-283-2152WEB:www.wisecontrol.com

E-mail:[email protected]

WISE CONTROL Inc.248 N. Aberdeen Ave.

Wayne PA 19087Tel:USA 610 964 9976Fax:USA 610 964 1190

For North and South America, please contact:

Distributor

WISE CONTROL reserves the right to amend the design andspecifications of

the instruments without notice. WISE GD2K02

IInnttrroodduuccttiioonnWISE CONTROL is an industryleader in detecting the potential danger fromcombustible and toxic gases that pose a threat topeople and property.

With over three decades of Industry experience,WISE CONTROL can provide you with the product,technical support and service you require.

WISE CONTROL’s Gas Detection products rangefrom simple gas alarm monitors and single pointalarm sensors to microprocessor datamanagement with communication via field bus toplant DCS.

Industries currently using WISE CONTROL GasMonitors include: Petrochemical and Chemical,Natural Gas plants & Refineries, Gas Storage &Loading facilities(LPG & LNG), Power Generation,Waste Water Treatment, Semi-ConductorFabrication and Steel plants.

❹ ...... Combustible Gas detector (GD-A8)❻ ...... Gas Detector Transmitter (GT 1010A)❽ ...... Gas Detector Transmitter with local display (GT1100)

...... Gas Detector Smart Transmitter (GT 2010)

...... Bar Graph Indicator, 3 color (GM 1000)

...... Intelligence Indicator (GM 2000)

...... Common Alarm Annunciator (AM 2000)...... Multi-unit Rack (MC 2100)

(22) ...... Single Indicator (SM 2000)(24) ...... Gas Vision Software

INTRODUCTION

CCoonntteennttssCONTENTS

Acetylene

Acetone

Butadiene

Benzene

Butane

Ethylene

Ethyl Alcohol

Hydrocarbon

Hydrogen

Hexane

Heptane

LNG

LPG

Methyl Alcohol

Propane

Pentane

Stylene Momomer

Vinyl Chloride

Monomer

Toluene

Xylene

Others

GD - A8Gas Detector

GT - 1010AGas DetectorTransmitter

GT - 1100Gas DetectorTransmitter WithLocal Display

GT - 2010Gas DetectorSmart Transmitter

GM - 2000Intelligence Indicator

GM - 1000Bar Graph Indicator, 3 color

SM - 2000Single Indicator

CommunicationLink Unit

Multi-unit Case (3, 6, 9, 12 POINTS)

MMI SystemGas Vision Software

Self Standing Panel

RACK MONITORING SYSTEMINDICATOR & ALARMING UNIT

COMBUSTIBLE GASDETECTORS

AI DO

DETECTOR❹ ❺

Features▶Easy Maintenance-plug In Sensor

▶Explosion Proof Housing (Exd llC T6)

▶Compact and Easy to Mount

Dimension

C O M B U S T I B L E G A S D E T E C T O R

The basic component of the detector is the Pellistor type sensor, based on the principle of Catalytic Oxidation. WISE CONTROL Sensors detect all combustible gases and aredesigned to meet Explosion Proof specificaiton Exd llC T6.

Optional ItemsWeather protection cover2″Yoke mounting blaketsAir ejector for sample drawing

COMBUSTIBLE GAS DETECTORMODEL : GD-A8

Description Specification Remarks

Principle Catalytic Oxidation

Measuring Gas Combustible Gas

Measuring Range 0 to 100% LEL LEL : Lower Explosive Limit

Sampling Diffusion

Housing Aluminium Diecasting(Body)

SUS 316 Metal (Sensor)

Heating Current 320 mA

Output mV Signal

Wire CVVS 2.0 SQ, 3 or 4 Core

Conduit Connection PF 3/4” PT, NPT Available

Response Time Less Than 20 Secs At T90 Less than 8secs At T50

Zero / Span Drift + / - 3% of F.S / Month

Expected Life Time 24 To 48 Months

Explosion Proof Exd llC T6

Operating Temperature -30℃ To 60℃ Below 95% R.H

(-22℉ To 140℉)

Standard Specifications

DETECTOR

❻ ❼

Features▶DC 4~20mA Output

▶Explosion Proof Housing (Exd llC T6)

▶Fast Response

Dimension

G A S D E T E C T O R T R A N S M I T T E R

The GT-1010A Detector consists of the Sensor, Transmitter PCB and Explosion Proof Housing which is designed for HydrogenCircumstance.The Microprocessor in the PCB provides a linear 4 to 20 mA signal which corresponds to 0 to 100% LEL Concentration of the measured gas.

Simple and Stable Transmission PCB design.

Easy maintenance by one person.

Optional Items

Weather Protection Cover2″Yoke Mounting BlacketAir Ejector For Sample Drawing

GAS DETECTOR TRANSMITTER MODEL : GT -1010A

Description Specification RemarksPrinciple Catalytic Oxidation

Measuring Gas Combustible Gas

Measuring Range 0 to 100% LEL LEL : Lower Explosive Limit

Sampling Diffusion / Suction

Housing Aluminium Diecasting

SUS 316 (Sensor Part)

Power DC 18V to 30V

Output DC 4 to 20 mA

Wire CVVS 2.0 SQ, 3 Core Shielded Cable Recomm-

ended

Conduit Size PF 3/4” PT, NPT Available

Response Time Less Than 20 Secs At T90 8 Secs At T90

Zero / Span Drift ±3% OF F.S / Month

Local Calibration Yes

Expected Life 24 to 48 Months

Explosion Proof EXd llC T6

Operating Temperature -30 to 60℃(-22 to 140℉) Below 95% R.H

Standard Specification

GT-1100❿

DETEC

TOR

❽ ❾

Features▶Local Display for measuring Values & Status

▶Applied the state of the art technology provides excellent stability

▶Easy maintenance using Remote Calibrator

▶Local calibration without opening the cover in Hazadous Location

▶Exd IIC Certified by CSA, FM and EC regulations

▶Various Installation orientations

▶Linear 4 To 20mA output can be connected to Various Kinds of receivers

Function

G A S D E T E C T O R T R A N S M I T T E R W I T H L O C A L D I S P L A Y

Optional Items

Remote Calibrator (GR 2000)Splash GuardWeather Protection Cover2B Yoke Mounting Bracket

GAS DETECTOR TRANSMITTER WITHLOCAL DISPLAYMODEL : GT -1100

Specifications

Item Description RemarksRange 0 To 100% LEL

Principle Catalytic Oxidation

Detection Diffusion

Response Time Max. 20 Secs At T90 8 Secs At T50

Zero/Span Drift ±3% OF F.S. / Month

Retransmission DC 4 To 20mA 600ohm loop Resistance

Display 3 1/2 Digit Measuring Value Param-

eter

Power DC 18V TO 30V

Power Consumption 0.6A For Initial Worn-up

0.25A For Nornal Operation

Explosion-Proof Class 1, Division 1 Group B.C & D Certified By FM, CSA

Distance Max 2.5Km

Operating Temper- 35℃ To 60℃, (-31 To 140℉) Below 95% R.H

ature

Conduit PF 3/4″ NPT, PT Available

Cable Shielded 4 Core, 2.0mm SQ.

Mounting Wall or 2B Yoke Mounting

Weight 1.6Kgs

POWER LAMP

IR SOURCE RECEIVER

CONDUIT A CONDUIT B

SENSOR

MEASURING VALUE OR PARAMETER

TROUBLE LAMP

IR SOURCE

ALARM ACK. OR RESET BOTTON

MODE SELECTION KEY

RARAMETER DATA ENTRY

PARAMETER UP

PARAMETER DOWN

Remote Calibrator(GR 2000)

3¼˝

GM-2010DETECTOR

Features▶Simplified Combination Transmitter which can function as a Single Indicator unit.▶Reduce the cost of Installation if applied with Digital Communication signal as a field bus system.▶Easy Maintenance & Calibration Service without openning the cover in Hazardous Areas.▶Various applied concentrations of the standard gas is possible with programming from the Remote

Calibrator.▶Two independent Programmable Alarm Settings.▶Isolated Output Signal can be connected with any Kind of controller, including DCS.▶Digital Display indicates gas concentrationin both Normal and Calibration modes. ▶State-of- the-Art technology, MCP based circuits provide continuous self-diagnostics and automatic

Fault Identification.▶Two independent Output Relays are programmable for Latching and Non-Latching operation.▶Relay Output are programmable for Energized (fail safe) or De-Energized operation.▶Non Volatile Memory retains Program Values & Calibration Factors during loss of power.

Dimension

G A S D E T E C T O R S M A R T T R A N S M I T T E R W I T H L O C A L D I S P L A Y

GAS DETECTOR S M A R TTRANSMITTERWITH LOCAL DISPLAYMODEL : GT -2010

Specifications

Item Description RemarksRange 0 To 100% LELPrinciple Catalytic OxidationDetection DiffusionResponse Time Max. 20 Secs At T90 8 Secs At T50Zero/span Drift ±3% Of F.S. / MonthRetransmition Isolated DC 4 To 20mA 600 Ohm loop Resistance

RS 485 (Modbus Protocol) OptionAlarm

Set Points Two Independent (H, HH)Set Value 0 To F.S ProgrammableOutput 2 X SPST (N.0 or N.C. Programm-

able)Rating AC 250V 3A

Display 4 1/2 Digit Measuring Value & Normal, Ist AL, 2nd AL. Fail & ParameterCal. Mode

Functions Test FunctionMeasuring RangeAlarm Output Hold Latch Or Non-LatchAddress For Digital Communi-

cationSpeed For RS-485Auto Zero / Span CalibrationStandard Gas Concentration Program

Power DC 16V To 30V, Max 0.5AExplosion Proof Class 1, Division 1, Group B.C & D Certified By FM, CSAConduit 3/4″PF, NPT. PT Other Size Available Cable Shielded 4 Core, 2.0mm SQDistance Max 2.5KmAmbient Temp -35℃ TO 60℃, (-31℉ To 140℉) Below 95% R.HWeight 2.15Kgs

POWER LAMP

3¼˝

IR SOURCE RECEIVER

DISPLAY WINDOW

CALIBRATION MODE

15+ AL, LAMP

2nd AL, LAMP

FAIL AL, LAMP

Optional Items

Remote Calibrator (GR 2000)Splash GuardWeather Protection Cover2B Yoke Mounting Bracket

SENSOR

INDICATOR

Features▶3 Color Changeable Bar Graph

▶Normal: Green, 1 AL: Yellow, 2 AL: Red

▶Self Diagnostics Functions

▶Bar Graph LED & Alarm Output to Receiver

▶Easy Alarm Set Point Adjustment

▶Linear DC 4 to 20mA Output Retransmission

▶High Rack Density, DIN cut size 36×144

▶Selectable the kinds of Detector by Jumper Pin

▶Plug In Modularity

▶Adjust Internal Settings without Power Off

▶Short Circuit Protection

▶0.5A Glass Fuse Protected

B A R G R A P H I N D I C A T O R

Dimension

BAR GRAPH INDICATORMODEL:GM-1000

Specifications

Item Description RemarksDisplay

Measuring 51 Segments Bar Graphic 3 Colour LED

Status Power, Fail. AL 1 & AL 2

Range 0 To 100 % LEL

Size 36(W)×144(H)×180(D)

Weigiht 670grs

Power DC 18V TO 30V

Power Consumption 10VA(Max)

Alarm

Set Points TWO (H, HH) L, LL Available

Set Value O To F.S Programmbie 2% Step

Output 2 X SPDT

Rating AC 250V 3A

Trouble N. O. or N. C.(AC 250V, 3A)

Retransmission DC 4-20mA Linear 600 ohm Load Impedance

Mounting Panel Flush Mounting

Operating Temp 0℃ TO 50℃(32℉ To 122℉)

st nd

INDICATOR

Features▶51 Segment LCD Bar Graph & 41/2 Digit Display

▶LCD Back Light

▶Universal Input Indicator use for all Kinds of Detector by Programming

▶Wide Applications connect with 2-wire, 3 wire & 4 wire Detectors

▶Selectable Range & Engineering Unit

Programmable range 0 To 9999, Unit, % LEL, ppm or Vol.%

▶Isolated Retransmmition Signal DC 4 to 20mA

▶Digital Communication Available, RS 485(Modbus)

▶3 Stage Passwords

▶Auto Zeroing

▶Alarm Output Hold

I N T E L L I G E N T I N D I C A T O R A N D A L A R M U N I T

Dimension

INTELLIGENT INDICATOR AND ALARM UNITMODEL : GM-2000

Item Description RemarksDisplay 51 Segments Bar Graph Dual Display

4 1/2 Digit Engineering Unit % LEL, PPM, Vol.%

Range 0∼100% LEL, 0 TO 9999 PPM Programmable Size 36(W)×144(H)×180(D) Weight 720grs Power DC 18V To 30VPower Consumption 10VA (Max) AlarmSet Points Two (H, HH) L, LL AvalableSet Value 0 To F.S Programmable Output 2×SPDTRating AC 250V, 3ATrouble N. O. or N.C., AC 250V, 3A

Retransmition Isolated DC 4 TO 20mA RS-485(Option) Functions 3 Stage Passwards

Alarm Output HoldProgramming Engineeing Unit %LEL, PPM, VOl.% Auto Zeroing, SpanCommunication SpeedCommunication Address

Mounting Panel Flush MouningOperating Temperat- 0℃ TO 50℃ (32℉ To 122℉)

ure

Specifications

INDICATOR

Features▶Common Alarm Device

▶3 Individual Alarm Outputs

▶Dry Contact for External Alarm or Annunciator

▶External Alarm Stop & Reset Available

▶Same Dimension as Indicator, Din-Cut

C O M M O N A L A R M A N N U N C I A T O R A L A R M U N I T

Dimension

COMMON ALARMANNUNCIATOR ALARM UNITMODEL :AM-2000

Item DescriptionDisplay Alarm Status Display By LED Power & Fail Display Buzzer Sound 75 dB at Im

Reset Switch Push Cover Plate

Ack. Botton Buzzer Stop

Output 2×SPDT For Alarm

1×SPDT For Fail

External Buzzer, N. O. or N. C.

Rating AC 250V 3A

Remote Control Remote Buzzer Stop

Remote Reset

Power DC 18 To 30V (Max, 5VA)

Mounting Panel Flush Mounting

Operating Temperature 0℃ To 50℃

Specifications

INDICATOR(21)

Features▶Various Kinds for 3ch., 6ch., 9ch. & 12ch

▶Convenience Mounting Housing Integrated

DC Power Regulator & Main power switch

▶Wall or Panel Flush Mounting

▶Easy Connection with Sensor Wire and Other

M U L T I - U N I T R A C K

Dimension

MULTI-UNIT RACKMODEL :MC-2100

Item DescriptionModel MC 2103 (3 Channels)

MC 2106 (6 Channels)

MC 2109 (9 Channels)

MC 2112 (12 Channels)

Size Refer to the Dimension Dwg.

Mounting Wall or Flush Mounting

Power AC 110V ± 10% or 220V ± 10%, 50 / 60Hz

DC Power Regulator DC 24V 3A Upto 8A

Main Switch On-Off Toggle Switch

Main Fuse Retractable Glass Fuse

Connection Front Side

Cable Entry Bottom

Specifications

INDICATOR

(22) (23)

Features▶Simple Indication with Easy Installation

▶Combine with Alarm Unit

▶Integrated DC Power Supply

S I N G L E I N D I C A T O R

Dimension

SINGLE INDICATORMODEL :SM-2000

Specifications

Item Description RemarksMode SM 2000 A(Conventional Type GD-A8

SM 2000 B(T/X With Combustible Gas ) GT-1010, GT-1100, GT-2010

SM 2000X(Toxic) GX-1100, GX-2010

Range 0 TO 100% LEL or Disired Value

Dispcay 3 1/2 Digit LED

Alarm

Set Points One

Set Value O To F.S Programmable

Output SPDT, AC 250V 3A

Retransmission DC 4 To 20mA

Power AC 85V to 240V, 50/60Hz Free Voltage

Mounting Surface Mounting

Cable Entry Bottom

GENERAL(24) (25)

Features ▶Easy to use GUI environment

▶Automatic alarm location display

▶Convenient monitoring by Graphics

▶Retrieve & checkout historical data

▶One man calibration possible

▶Low cost system using PC

▶Alarm paging to personal pager (optional)

PC Specifications▶CPU-Pentium class

▶O/S-Windows 95, 98, NT

▶RAM-32MB or Up

▶HDD-2.0GB or Up

▶Monitor-17inch or Up

▶Printer-Color Inkjet of Laser

▶Mouse, PS/2 or TouchScreen

▶Modem(optional)-14400bps or Up

G A S V I S I O N S Y S T E M

Capacity Introduction

GT-2010 GT-1010A GT-2010 GM-1000

GMS-2000, WISE CONTROL Gas Monitoring System

for Windows, is a general gas security management

system applying widely used state-of-the-art

technology.

It is easy to check the current status using either the

mouse or touch screen interface and can automatically

page the user if the alarm is activated. It is a convenient

and easy to use gas

monitoring system that uses a personal to log historical

data and produce Alatm and Daily Reports etc.

HORN VALVES

▲LOCATION

▲STATUS

▲TREND

▲ANNUCIATOR

GAS VISION SYSTEM MODEL : GMS-2000

COMPUTER