2004 standard fiber trailer pricing - mohawk...

3
A WBE and ISO 9001:2000 Certified Company Mohawk Ltd. is pleased to provide the following proposal for a Manhole/Pipe/Cable Splicing Trailer per the following specifications: Trailer: Rollingstar RS824TS70 8’x24’ Custom Enclosed Trailer: 15,000 lb. GVWR, smooth FRP fiberglass insulated wall system, structural steel frame w/extended tongue, tandem 7,000 lb. torsion electric brake axle suspension, radial tires on white modular wheels, adjustable height pintle coupler w/7,000 lb. drop-leg jack & welded safety chains, one piece aluminum roof, D.O.T. compliant lighting Exterior walls panels are insulated FRP composite walls, 1" R-7 urethane foam insulation. 1/4 panels, 1-1/2 total wall thickness Interior partition walls are ½” FRP panels over metal or wood frame Foldable wall system for middle access room to include (2) wall sections (composite FRP panels), hinged together and to exterior wall return, latches, angle ceiling bumpers w/gasket and floor sweep (seal) Bright white gel coat interior and exterior wall finish Fabricated recessed wall section at front streetside of the trailer to accommodate Bard Air Conditioner (approx. dimensions per print), include removable WTB locking access door approx. 18" wide x 48"high in side to access air conditioner Conspicuity tape sides and rear "Bump" rollers heavy duty, mounted under rear trailer frame Extended trailer tongue w/painted steel treadplate surface Front step, 16"Dx24"W, hinged to store on top of tongue, steel grate surface, removable handrail Rear steps, heavy-duty fabricated grate surface, hinged or foldaway Gantry for electric chain hoist, includes steel frame around rear interior compartment door to support "I" beam which is also welded to rear trailer header (chain hoist provided by customer) (3) through-the-floor vault access holes w/retractable manhole rim includes: approx 36" through-floor hole w/flange and walk-on cover attached to a collapsible reinforced PVC hose/boot with manhole rim and restraining system to hold manhole rim in retracted position Front personnel door, 32" wide commercial steel, no window or screen, knob & deadbolt style locksets Rear personnel door, 32" wide commercial steel, no window or screen, knob & deadbolt style locksets (3) Interior doors, flat panel steel w/jamb and threshold, full weather-stripping and seal Double rear doors w/camlock next to rear personnel door, approx width is 48"W x full height (3) 12"x12" exterior access door located at each manhole access area, WTB aluminum treadplate w/"T" latch and seal Finished ceilings are polyboard liner over roof bows w/insulation Flooring: 1/8" steel treadplate w/painted non-slip sand-type finish (3) 2.5" I.D.x8" long pipe w/flange welded and reinforced to steel floor for customer supplied davit crane (3) Fire extinguisher holders, 8" I.D. steel pipe x 12" long welded to floor (fire extinguisher supplied by customer) 2" water line running full length of trailer w/2" male quick connects at each exterior end & at (3) locations inside of trailer ((5) total), all quick connects supplied with latching caps 800-225-6642 PO Box 340 One Newell Lane Chadwicks, NY 13319 Fax: 315-737-7347 www.mohawkltd.com E-mail - [email protected]

Upload: lamtram

Post on 12-Mar-2018

217 views

Category:

Documents


1 download

TRANSCRIPT

A WBE and ISO 9001:2000 Certified Company

Mohawk Ltd. is pleased to provide the following proposal for a Manhole/Pipe/Cable Splicing Trailer per the following specifications: Trailer: • Rollingstar RS824TS70 8’x24’ Custom Enclosed Trailer: 15,000 lb. GVWR, smooth FRP

fiberglass insulated wall system, structural steel frame w/extended tongue, tandem 7,000 lb. torsion electric brake axle suspension, radial tires on white modular wheels, adjustable height pintle coupler w/7,000 lb. drop-leg jack & welded safety chains, one piece aluminum roof, D.O.T. compliant lighting

• Exterior walls panels are insulated FRP composite walls, 1" R-7 urethane foam insulation. 1/4 panels, 1-1/2 total wall thickness

• Interior partition walls are ½” FRP panels over metal or wood frame • Foldable wall system for middle access room to include (2) wall sections (composite FRP

panels), hinged together and to exterior wall return, latches, angle ceiling bumpers w/gasket and floor sweep (seal)

• Bright white gel coat interior and exterior wall finish • Fabricated recessed wall section at front streetside of the trailer to accommodate Bard Air

Conditioner (approx. dimensions per print), include removable WTB locking access door approx. 18" wide x 48"high in side to access air conditioner

• Conspicuity tape sides and rear • "Bump" rollers heavy duty, mounted under rear trailer frame • Extended trailer tongue w/painted steel treadplate surface • Front step, 16"Dx24"W, hinged to store on top of tongue, steel grate surface, removable

handrail • Rear steps, heavy-duty fabricated grate surface, hinged or foldaway • Gantry for electric chain hoist, includes steel frame around rear interior compartment door to

support "I" beam which is also welded to rear trailer header (chain hoist provided by customer) • (3) through-the-floor vault access holes w/retractable manhole rim includes: approx 36"

through-floor hole w/flange and walk-on cover attached to a collapsible reinforced PVC hose/boot with manhole rim and restraining system to hold manhole rim in retracted position

• Front personnel door, 32" wide commercial steel, no window or screen, knob & deadbolt style locksets

• Rear personnel door, 32" wide commercial steel, no window or screen, knob & deadbolt style locksets

• (3) Interior doors, flat panel steel w/jamb and threshold, full weather-stripping and seal • Double rear doors w/camlock next to rear personnel door, approx width is 48"W x full height • (3) 12"x12" exterior access door located at each manhole access area, WTB aluminum

treadplate w/"T" latch and seal • Finished ceilings are polyboard liner over roof bows w/insulation • Flooring: 1/8" steel treadplate w/painted non-slip sand-type finish • (3) 2.5" I.D.x8" long pipe w/flange welded and reinforced to steel floor for customer supplied

davit crane • (3) Fire extinguisher holders, 8" I.D. steel pipe x 12" long welded to floor (fire extinguisher

supplied by customer) • 2" water line running full length of trailer w/2" male quick connects at each exterior end & at

(3) locations inside of trailer ((5) total), all quick connects supplied with latching caps

800-225-6642 PO Box 340 • One Newell Lane • Chadwicks, NY 13319 • Fax: 315-737-7347

www.mohawkltd.com • E-mail - [email protected]

A WBE and ISO 9001:2000 Certified Company

800-225-6642 PO Box 340 • One Newell Lane • Chadwicks, NY 13319 • Fax: 315-737-7347

www.mohawkltd.com • E-mail - [email protected]

• (2) 1" airline running full length of trailer with ball valves at one exterior end & at (3) locations inside of trailer ((4) total)

• 48"x24" steel workbench top, double 3/4" plywood core w/steel top, finished edges 3-sides, (2) steel support frame w/tube or pipe legs (supports)

• 72"x18" steel workbench top, double 3/4" plywood core w/steel top, finished edges 3-sides, (2) steel support frame w/tube or pipe legs (supports)

• (1) Bench vise 8" Wilton or equivalent

Electrical • AC Power Panel, single phase 200 amp w/circuit breakers • Voltage meter to monitor incoming power included near AC power panel • (2) Appleton "PowerTite" 200 amp pin and sleeve receptacle w/AJA Mounting Box; 3W4P, 2-

1/2" hub; ADJA20034-250, one located front exterior wall and one located in the front manhole access area, both are power input devices to the AC power panel

• Transfer switch (manual) between the (2) Appleton 200 amp pin & sleeve receptacles, either of which can be the power input for the trailer

• (9) 48" fluorescent ceiling lights, 110 volt surface mount w/wrap around lens, (2) 3-way 110 volt wall switches (see adder below for explosion-proof lighting)

• (6) double duplex wall outlet, 20 amp, metal surface mount box • (3) double duplex outlet on extension cord, 20 amp, metal box w/25' SJO power cord,

permanently wired to junction box • (3) 110v GFCI protected duplex power outlets, exterior w/weatherproof cover • (2) 50 amp 125V 2 pole 3 wire twist lock receptacle, surface mounted metal double duplex

box, Hubbel CS6370 or equivalent, mounted in front manhole access room • LED running light system, 7-diode, (2) 15" turn/tail lights, (15) markers • Emergency strobe light system includes (8 lightheads total) with (2) single pattern power

supplies • Exhaust fan, through the wall mounted with hood, located over curbside work bench, Broan

or equivalent 10" @ 380 CFM, with wall switch • (6) 500W 110 volt flush mount quartz scene lights (4.2A), individually switched • (4) 110V 4' electric baseboard heater w/integral thermostat (4.2A), includes steel or aluminum

guards HVAC Systems • Furnish and install new Bard 5 Ton HVAC unit on front exterior wall of trailer • Furnish and install new Bard 3 Ton HVAC unit on recessed side exterior wall of trailer • Furnish and install new sheet metal supply and return ductwork, vents, dampers and

accessories • Furnish and install all required HVAC controls and electrical subsystems