2008 2010 20112014 supermarket warehouse cold storage aquilon tm chiller aquilon tm data center co2...

34
200 8 201 0 201 1 201 4 Supermark et Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Upload: cleopatra-long

Post on 13-Dec-2015

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

2008 2010 2011 2014

Supermarket WarehouseCold Storage

AQUILON TM Chiller

AQUILON TM

Data Center

CO2 Technologies

Page 2: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

As you move your business forward, it is our goal today, to provide you with a better understanding that you do have refrigeration management options.

Page 3: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Corporate Social Responsibility

Achieving

Profitability Planet

People

Balancing needs, nature, profitability and risk………

Page 4: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Looking Ahead…………

A Changing Social Conscience A Changing Corporate

ConscienceSolutions ………

Good For BusinessGood For People

Good For The Planet

Page 5: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

“Our Government is once again taking action to address climate change. We have already taken action on some of the largest sources of emissions in this country, the transportation and electricity generation sectors, and today, building on our record, we are proud to announce that Canada will be taking pre-emptive action to reduce and limit harmful HFC emissions, before they increase.”– The Honourable Leona Aglukkaq, Canadian Minister of the Environment, September 2014

Looking Ahead………… Unpredictable Future?

‘‘To reduce emissions of HFCs, the United States can and will lead both through international diplomacy as well as domestic actions.’’ This proposed rule is part of our domestic commitment to take action now and, by doing so, also supporting efforts to secure a global HFC phasedown. - President Obama’s Climate Action Plan, June 2013

Page 6: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Risk Mitigation – Health & Safety

Employees, Environment &The Community You

Work In

"I own a large inventory of a hazardous chemical refrigerant, stored and operating within the daily work activity of many employees, suppliers and possibly customers. A catastrophic leak of this chemical can seriously injure or kill. What am I going to do to prevent an accident, and who holds responsibility under the law of making it so?"

Ammonia has excellent heat transfer capabilities and does not contribute to either ozone layer depletion (ODP) or global warming (GWP) . For this reason it has been well established for many years. In fact, some users are so loyal to ammonia that discussion of any other refrigerant solution receives little consideration.

However, risk mitigation strategies, Corporate Social Responsibility, public perception, anticipated new regulations and legislations, and the increasing availability and feasibility of options such as CO2, are changing this landscape.

Page 7: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Risk Mitigation – Health, & Safety

Employees, Environment &The Community You

Work In

……..Town officials urged residents to leave the area Friday morning, fearing that smoke irritants and hazardous materials could cause health risks. Tecumseh fire Chief Doug Pitre says that two holding tanks have been filled with ammonia from the plant, which might have become a hazard if the fire had not been contained………. - Excerpt of CTV news report, July 18, 2014

Reduction of 90% of the NH3

charge

CO2 provides……..

Page 8: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Looking Ahead………… Future Looking Clearer?

Cap-and-Trade System

The Ontario government will move forward with a cap-and-trade system and its carbon pricing system. Proceeds from this program will be directed toward key priorities that will help lower greenhouse gases.

There will be an overall emission limit (the cap) on those facilities included in the program, and methods of rewarding companies under this threshold. 

Ontario Government – April 2015

Page 9: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

So………… What About Carbon Dioxide

Page 10: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

History of CO2

• Technology that originally emerged in the mid-19th century

• 1850 : First CO2 refrigeration patent by Alexander Twining (England)

• 1890 : CO2 is seen as the only “safe” refrigerant

• Golden age from 1920 to 1930 with system up to 350T, to be phased out in favor of synthetic refrigerants (R-12)

In the latter part of the 20th century, scientists began to understand the relationship between synthetic refrigerant usage and the impact to the ozone layer and global warming. With the signing of the Montreal Protocol, the world’s developed economies focused on restrictions and a planned course of action towards elimination of the Ozone Depletion (ODP) CFC and HCFC synthetics

Page 11: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

• As a result, CO2 resurfaced in the 1990s

• 1991 : “Transcritical” patent by Gustav Lorentzen (Norway)

• 2009 : First appearance of CO2 systems in grocery stores in Canada

History of CO2

• 2010 : First CO2/NH3 cascade system for distribution centers in Canada (Carnot)

• 2010 : First Ice rink with (in slab) recirculated CO2 system in North America

• 2012 : First Ice rink with direct heat recovery CO2 system in North America (Carnot)

• >2013: Transfer of technology to other refrigeration applications (Carnot)

• 2013 : First Data center to run a CO2 cooling unit (Carnot AQUILON TM unit)

• Reliable and proven systems• Presence in Europe for over 20 years

• Presence in Canada for more than 7 years

Page 12: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Securing Their Future – Consumer Goods Forum

On refrigeration, the Forum agreed to begin phasing-out hydrofluorocarbon (HFC) refrigerants as of 2015 and replace them with non-HFC refrigerants.

X

Page 13: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

With a

Ozone Depletion Potential of “0”

Global Warming Potential of “1”

Non Poisonous

Non Toxic

Non Corrosive………..

Page 14: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

provides owners with a solution that is

Flexible

Reliable

Cost Effective

Safe …..and

Environmentally

Responsible!

CO2

Page 15: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Will be prohibited from January 1st, 2020:- Commercial refrigeration with HFC at GWP of 2500 or more

- Ex.: R404A, …

Will be prohibited in 2022:- Commercial refrigeration (including sealed) with HFC at GWP of 1500 or more

- Ex.: R410A/R134A/R422D/R407C, …- Commercial refrigeration plant with a capacity of 40kW or more with GWP of 1500

or more (including actual retrofit fluids)- Ex.: R134A/R422D/R427A

Will be prohibited in 2025:- Air conditioning with GWP of 750 or more

From 2015 and reducing gradually:- The European Commission will allocate quotas to producers and importers of

HFCs- The HFC production and their entry in the European market : in general, the use of

HFCs will be reduced as follows:

European Freon Restriction Summary

2015 2016-17 2018-20 2021-23 2024-26 2027-29 20300%

20%

40%

60%

80%

100%

120%

-80% by 2030

Page 16: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Profiles

Over 80 Systems Installed…

Page 17: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Arenas & Distribution Centers

Innovation

Rigor

Passion

The problems

The vision

Innovation

Rigor

Passion

The problems

The vision

AFTER

BEFORE

Reduction of 90% of the NH3

charge

Page 18: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Innovation

Passion

Mohamad

Spring 2012 : First meeting between end user and Carnot engineers.

November 2013 : The first prototype.

Innovation

Passion

Mohamad Rigor

The vision

The problems - HFCs- Leaks- Energy

Rigor

The prototype system function very well. Subsequent to additonal engineering collaboration, the first field unit was installed in August 2014.

AQUILON TM – The Future of Data Center Cooling

Page 19: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Distribution Centers and Supermarkets

Page 20: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies
Page 21: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Mitigating Risk………….Improving ROI…..NH3 / CO2 Hybrid Refrigeration System

Page 22: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

NH3 / CO2 Cascade Refrigeration System

Surface: 12,000 m2 – 12m highConsumption :

• 4.563.442 lbs/day• (2.069.945 kg/day)

Ripening room : • 22 Bananas (CO2) • 3 Avocados (CO2)

• 22 bay loading dock

Business CaseThe Carnot system :

• Temperature between 0 and 15oC

• 512 TR • 800 lbs NH3

• 4500 lbs CO2

Page 23: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

NH3 / CO2 Refrigeration system

Page 24: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Technologies Unique to CO2

• Quick and efficient evaporation• No additional energy consumption• No heat addition in the system• Single pipe CO2 system provides both heating and cooling

with no additional requirements for supplemenatry heating.

Hot gas defrost

Page 25: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

• Designed so that the heat recovery is direct• Heat is 8 times greater than traditional systems with

intermediate glycol loop combined with ammonia• Typical heat reclaim yields hot water at 185F• No energy consumption or any additional equipment (pumps,

glycol loop, heating, etc.)

Heat recovery

Page 26: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

New Patented Technologies

• Free cooling Mode at all times with outside temperature of 7˚C (nearly 4000 hours per year and up to 14˚C)

• Ammonia compressors completely stopped

• Equipment lifecycle cost reduced

“Free cooling” Mode

Page 27: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

CO2 Transcritical Refrigeration System• Warehouse

• Products Cranberry• Volume 544 310 kg (1 200 000 lbs)• Area 4 180 sq. m (45 000 sq. ft.)• Height 12 m (40 ft)• Loading dock 4 doors

• System• Refrigerant R744 only (CO2)• Capacity 644 kW (183 TR)• Temperature - 18˚C (0˚F)• Refrigerant charge 1 500 kg (3 300 lbs)• Heat recovery Sub-floor• Defrost Hot gas

Page 28: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies
Page 29: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

CO2 Transcritical Refrigeration System

• Benefits• No HFCs• No NH3 (ammonia)• Non-toxic refrigerant• No cooling tower : Eliminate water consumption and chemical treatment• Reduces piping and insulation sizes by 50%• Full heat recovery for building• Free cooling mode (thermosyphon) also available• Typical installed costs up to 20% less than ammonia

Page 30: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

/ (Chillers)

Page 31: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Positively IMPACTS your

Environmental STEWARDSHIP in

THREE ways

1. Lowers Global Warming Potential by eliminating Freon2. Lowers Fossil fuel burning through high quality heat reclaim3. Lower energy consumption reduces power consumption from grid

Page 32: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Positively IMPACTS your

BUSINESS in

THREE ways

1. Frequently has lower initial cost of installation2. Frequently has lower lifecycle owning & operating costs3. Always lowers risk management and increases public perception

Page 34: 2008 2010 20112014 Supermarket Warehouse Cold Storage AQUILON TM Chiller AQUILON TM Data Center CO2 Technologies

Thank you