2010 brochures

20
OMNI II TOUCH SCREEN PATIENT MONITOR n 12.1” color TFT display with touch screen. n Multi-lead ECG monitoring n Touch screen user interface n NIBP list & OxyCRG dynamic view display n Drug dose calculations n Large font display with 4, 6 & 8 waveforms shown n Networkable with Central Monitoring System via a wireless or wired network n S-T Segment & 72 hours trend data analysis n Compact design is convenient for mobile monitoring n Multi-lingual settings n Optional: Dual IBP, EtCO2 and Built-in thermal recorder Advanced, Affordable Medical Technology For The World ECG, SPO2, NIBP, HR, TEMP, RESP.

Upload: christine-mqikela

Post on 02-Dec-2014

218 views

Category:

Documents


4 download

DESCRIPTION

Medical Equipment- Patient Monitors, Anaesthetic Delivering Machines, Saturation Monitors

TRANSCRIPT

Page 1: 2010 Brochures

OMNI IITOUCH SCREENPATIENT MONITOR

n 12.1” color TFT display with touch screen.n Multi-lead ECG monitoringn Touch screen user interfacen NIBP list & OxyCRG dynamic view displayn Drug dose calculationsn Large font display with 4, 6 & 8 waveforms shownn Networkable with Central Monitoring System via a wireless or wired networkn S-T Segment & 72 hours trend data analysisn Compact design is convenient for mobile monitoringn Multi-lingual settingsn Optional: Dual IBP, EtCO2 and Built-in thermal recorderAdvanced, Affordable Medical Technology For The World

ECG, SPO2, NIBP, HR, TEMP, RESP.

Page 2: 2010 Brochures

Authorized Distributor:

12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436

Web: www.infiniummedical.com • Email: [email protected]

Physical Dimensions & WeightMain UnitDimension: 555mm H x 335mm W x 235mm DWeight: 5kg

ApplicationNeonatal, pediatric and adult patients

Operation EnvironmentPowerSource: External AC power or internal batteryAC Power: 100-240VAC, 50/60Hz, <150VABattery: Rechargeable Lead-Acid Operating time under the normal

condition: 1 hour Operating time after the first alarm of

low battery: 10 minesTemperatureWorking: 5-40˚CStorage: -20-65˚CRelative HumidityWorking: 30-75%Storage: ≤80%AltitudeOperating Altitude: Up to 5,000 metersHyperbaric Pressure: Up to 405.3 kPa

Peformance SpecificationsDisplay: 12.1” color TFT, Touch ScreenResolution: 800 x 600 pixelsTrace: 4, 6, 8 or 9 waveforms ECG (I, II, III, aVR, aVL, aVF, V1-V6),

PLETH, RESP, IBPx2, ETCO2Indicator: Alarm indicator Power indicator QRS beep and alarm soundTrend time: 72 hoursRecorder: Built-in, thermal array, 2 channels Record width: 48mm Recorder paper: 50mm Record speed: 25mm/s, 50mm/sOxyCRG: Combines HR, SPO2 and Respiration trends into a single graph

ECGInput: 5-lead ECG cable and standard AAMI

line for connectionLead Choice: I, II, III, aVR, aVF, aVL, VGain Choice: x0.125, x0.25, x0.5, x1.0, x2.0Filter: Diagnostic mode: 0.05-100Hz Monitoring mode: 0.05-75Hz Surgical mode: 1-20HzECG Waveforms: 7 channelsPenetration Voltage: 4000VAC 50/60Hz

ECG (cont.)Sweep Speed: 12.5, 25 and 50 mm/sHR Display Range: 15-300bpmAccuracy: ±1% or ±1bpm, whichever is greaterS-7 Segment Detection: 7 channelsMeasurement Range: -2.0mv - +2.0mvArrhythmia Analysis: 13 typesAlarm Limit Range Setting Upper limit: 80-400bpm Lower limit: 20-150bpm

RESPMeasure Method: RA-LL impedanceRange: 0-120 rpmAccuracy ±3 rpmAlarm Upper-lower Limit Setting: Upper limit: 6-120 rpm, Lower limit: 3-120 rpmSweep Speed: 12.5 and 25 mm/s

NIBPMeasuring Technology: Automatic oscillating measurementCuff Inflating: <30s (0-300mmHg, standard adult cuff)Measuring Period: AVE<40sMode: Manual, Auto, STATMeasuring Interval in AUTO Mode: 2 min-4 hrsPulse Rate Range: 30-250 (bpm)Measuring Range: Adult/Pediatric Mode SYS 40-250 (mmHg) DIA 15-200 (mmHg) Neonatal Mode SYS 40-135 (mmHg) DIA 15-100 (mmHg)Resolution: 1mmHgAccuracy: Pressure Maximum Mean error: ±5mmHg Maximum Standard deviation: 8mmHgOverpressure Protection: Adult Mode 280 (mmHg) Neonatal Mode 150 (mmHg)Alarm Limit Setting SYS 50-240 mmHg DIA 15-180 mmHg

TEMPRange: 0-50˚C (32-122˚F)Accuracy: Without sensorDisplay Resolution: 0.1˚CAlarm Upper-lower Limit Setting: Upper limit 0-50˚C Lower limit 0-50˚CChannel: 2 channels, provide T1, T2, ∆T

SPO2ASpO2: Anti-motion SpO2 SpO2% Range: 0-100%SpO2 Accuracy: ±2% 70-100%, non-motion ±3% 70-100%, motionPulse Rate Range: 30-250 bpmPulse Rate Accuracy: ±2 bpm (non-motion) ±3 bpm (motion)Alarm Upper-lower Limit Setting: upper limit 70-100% lower limit 70-100%SpO2 Probe Red light LED wavelength 660nm±5nm Infrared light LED wavelength 905nm±10nm

IBP (OPTION)Measurement Range: -50-300mmHgChannel: 2 channelsPressure transducer: sensitivity, 5µV/V/mmHgImpedance range: 300-3000ΩTransducer sites: ART, PA, CVP, RAP, LAP, ICPResolution: 1mmHgAccuracy: ±1mmHg or ±2%, whichever is greaterAlarm range: -50-300mmHg

EtCO2 (OPTION)Mode of Sampling: SidestreamPrinciple of Operation: Non-dispersive infrared (NDIR) single

beam optics, dual wavelength, no moving parts.

CO2 measurement Range: 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)CO2 Calculation Method: BTPS (Body Temperature Pressure Saturated)CO2 Resolution: 0.1mmHg(0-69mmHg), 0.25mmHg(70-150mmHg)CO2 Accuracy: 0-40 mmHg ± 2 mmHg 41-70 mmHg ± 5% of reading 71-100 mmHg ± 8% of reading 101-150 mmHg ± 10% of reading Above 80 breath per minute ± 12% of reading Sampling rate: 100HzRespiration Rate: 2-150 bpmRespiration Rate accuracy: ±1 breath Response Time: <3 seconds - includes transport time

and rise time Inspired CO2 measurement Range: 3-50 mmHg

Specifications subject to change without notice.

OMNI II TECHNICAL SPECIFICATIONS

Selectable Screens:4, 6 or 8 waveforms

Page 3: 2010 Brochures

OMNI IIIMULTI-FUNCTIONPATIENT MONITOR

n Facility to measure many parameters: ECG (3 or 5 lead) with ST segment monitoring, respiration, dual temperature monitoring, SpO2, non-invasive blood pressure.

n Up to 8 waveforms displayedn Multi-lead simultaneous ECG monitoringn Auto setting of alarm limitsn Graphical / Tabular trending n Color coded alarmsn Patient data entryn Battery backup (2 removable batteries)n Networking capabilityn Large high resolution 15 inch screenAdvanced, Affordable Medical Technology For The World

ECG, Respiration, SpO2, NIBP,

Temperature

Page 4: 2010 Brochures

Authorized Distributor:

12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436

Web: www.infiniummedical.com • Email: [email protected]

PHYSICAL DIMENSIONS & WEIGHTBase Unit: 309mm H×365mm W×159mm DWeight: 7.0kgs

APPLICATIONNeonatal, pediatric and adult patients

PEFORMANCE SPECIFICATIONSDisplay: 15” color TFTResolution: 1024×768Trace: 8 waveforms ECG(I, II, III, aVR, aVL, aVF, V1-V6),

PLETH, RESPIndicator: Alarm indicator Power indicator QRS beep and alarm soundTrend time: 1- 48 hoursRecorder: Built-in, thermal array, 2 channelsRecord width: 48mmRecorder paper: 50mmRecord speed: 25mm/s, 50mm/s

ECGInput: 5-lead ECG cable and standard AAMI

line for connectionLead Choice: I, II, III, aVR, aVF, aVL, V, TESTGain Choice: ×0.5, ×1, ×2Frequency Characteristic: 0.05~35 Hz (+3dB)ECG Waveforms: 7 channelsPenetration Voltage: 4000VAC 50/60HzSweep Speed: 12.5, 25 and 50 mm/sHR Display Range: 30~300bpmAccuracy: ±5%, whichever is greaterAlarm Limit Range Setting: upper limit:80~400bpm lower limit: 20~150bpm

RESPMeasure Method: RA-LL impedanceRange: 0~120 rpmAccuracy: + 3 rpmAlarm Upper-lower Limit Setting: upper limit: 6~120 rpm, lower limit: 3~120 rpmSweep Speed: 12.5 and 25 mm/s

NIBPMeasuring Technology: automatic oscillating measurementCuff Inflating: <30s (0~300 mmHg, standard adult cuff)Measuring Period: AVE<40s Mode Manual, Auto, STAT Measuring Interval in AUTO Mode 2 min~4 hrs

NIBP (continue)Pulse Rate Range: 30~250 (bpm)Measuring Range: Adult/Pediatric Mode SYS 40-250 (mmHg) DIA 15-200 (mmHg) Neonatal Mode SYS 40-135 (mmHg) DIA 15-100 (mmHg)Resolution: 1mmHg Accuracy: Pressure Maximum Mean error: ±5mmHg Maximum Standard deviation: 8mmHgOverpressure Protection: Adult Mode 280 (mmHg) Neonatal Mode 150 (mmHg)Alarm Limit Setting SYS 50~240 mmHg DIA 5~180 mmHg

TEMPRange: 25~50 (ºC)Accuracy: ±0.2ºC (25.0~34.9 ºC) ±0.1ºC (35.0~39.9 ºC) ±0.2ºC (40.0~44.9 ºC) ±0.3ºC (45.0~50.0 ºC)Display Resolution: 0.1 ºCAlarm Upper-lower Limit Setting upper limit 0~50 ºC, lower limit 0~50 ºCChannel: 2 channelsAlarm Limit Setting: 10~50 ºC

SPO2ASpO2: Anti-motion SpO2SpO2% Range: 0-100%SpO2 Accuracy: ±2% (70~100%, non-motion) ±3% (70~100%, motion)Pulse Rate Range: 30-250 bpmPulse Rate Accuracy: ±2 bpm ±3 bpm (motion)Alarm Upper-lower Limit Setting upper limit 70~100%, lower limit 70~100%SpO2 Probe Red light LED wavelength 660nm±5nm Infrared light LED wavelength 940nm±10nm

NETWORKINGIndustry standard 802.11b/g wireless network Frequency Range: 2.412 – 2.484 GHz Connected bedside number: up to 8 bedside monitors

POWERSource: External AC power or internal batteryAC Power: 100-240VAC, 50/60Hz, 150VABattery: Built-in and rechargeableCharge Time: 4 hoursOperating Time: 1 hour

ENVIRONMENTAL SPECIFICATIONSTemperature: Operating: 5~40 °C Storage: -10~45 °CHumidity range: Operating: ≤80 % Storage: ≤80 %

BATTERYRechargeable Lead-AcidOperating time under the normal condition - 1 hourOperating time after the first alarm of low battery - 10 minutes

RECORDER (OPTION)Record Width 48 (mm)Paper Speed 25 (mm/S)Trace 2

FUSE (SELF-RECOVERY)Input fuse: 3.15A/250V

LIFETIME8 Years

OMNI III TECHNICAL SPECIFICATIONS

The Omni III patient monitor delivers the best performance and flexibility for the price. The Omni III features a large 15” high resolution screen while still remaining light and portable.

Page 5: 2010 Brochures

OMNI ExprEssPORTABLE PATIENT MONITOR

n Touch Screen

n 3 waveforms displayed

n Simultaneous multi-lead ECG monitoring

n Battery backup

n Graphical and tabular trending

n Audible and visual alarms

n Advanced ST and arrhythmia detection

n Quick BP readings recall

n Optional EtCo2

n Optional printerAdvanced, Affordable Medical Technology For The World

ECG, Respiration, SpO2, NIBP, Temperature,

Recorder

Page 6: 2010 Brochures

Authorized Distributor:

12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436

Web: www.infiniummedical.com • Email: [email protected]

Safety Approval & Quality SystemDesigned to meet IEC60601-1-1988, EN60601-1-1, EN60601-2Class II Equipment, double insulatedType BF applied parts ISO9001 & EN46001 CertifiedPower RequirementsPower Supply AC 90-264V/47-63HzInput Power ≤55VAFuses Two fuse sockets in the rear panel indicated by “FUSE”,

IO5X20, 2A/250VBattery 12V/4.0AH sealed lead-acidCharge time ≥4 hoursOperating time ≥2 hours (full recharge)Battery Charging Method Automatic charging after monitor is connected to AC power

supply (with charge protection function)Discharge Protection When powered by battery, the monitor will be automatically

turned off when battery power is almost used up.

Performance SpecificationsECG Patient Safety Standard IEC60601-1-1988CMRR ≥60dB (Common Mode Rejection Ratio)Heart Rate Range 20 ~ 254bpm ± 1bpmHeart Rate Averaging 8 second averageST Segment Range -0.8 ~ + 0.8mVInterface AAMI 6-pinLead Selection I, II, III (3 lead mode) I, II, III, aVR, aVL, aVF, V (5 lead mode) (ST and

Arrhythmia analysis) Lead Fault Alarm Audible, Visual Input 5-lead ECG patient cableQRS Indicator Audible and Visual AlertWaveform Storage 6 minutesSweep Speed 12.5/25/50 mm/secGain Selection 4mV, 2mV, 1mV, 0.5mV, 0.25mV,AutoTrends 2 hours ➔ 4 hours ➔ 8 hours ➔ 24 hours ➔ 48 hoursPatient Isolation Breakdown voltage: 4000VAC 50Hz 60 seconds Leakage current: <10µAFrequency width Monitoring mode: 0.5 ~ 40Hz (+0.4dB,-3.0dB) Surgery mode: 0.5 ~ 20Hz (+0.4dB, -3.0dB)

(not calibration significant)Patient Drive Current <10µAEnclosure Leakage Current <0.1mAMaximum T Wave Rejection Capability 1.2mVHeart Rate Alarm Response Time < 7 secondsAspect Ratio 0.24 ~ 0.6 sec/mVAlarm Frequency Low alarm 2-2.4kHz High alarm 3-3.4kHzDefibrillator Protected & ESIS Protected Tested with 5kVRecovery Time Following Defibrillation <5 secondsRespirationMeasurement Method Thoracic ImpedanceRespiration Rate Range 0 ~ 100±1rpmAccuracy ±2 rpm

Pulse Oximetry (SpO2) SpO2 Range 0-100% Adult/Pediatric/NeonateSpO2 Averaging 8 second averageSpO2 Accuracy ±2% (70 ~ 100%), ±3% (40 ~ 70%)Pulse Rate Range 30 ~ 250bpmPulse Rate Averaging 8 beat averagePulse Rate Accuracy ±1% @ 30 ~ 100bpmSensor Types Finger, Universal “Y”, wrap probesPulse Rate Display DigitalNon-Invasive Blood Pressure ( NIBP )Method Automatic oscillometricParameters Systolic, diastolic, mean arterial pressure, pulseScale mmHg or kPaOperating Modes Manual, Automatic, ContinuousRepeat Cycles 1 ~ 10, 15, 30, 60, 90, 120 minutesDetermination - Systolic Adult/pediatric 40 ~ 250mmHg (5.3 ~ 33.3kPa) Neonate 20 ~ 160mmHg (2.7 ~ 21.3kPa) - Diastolic Adult/pediatric 10 ~ 180mmHg (1.3 ~ 24.0kPa) Neonate 10 ~ 140mmHg (1.3 ~ 18.7kPa)Cuff Pressure Range Adult/pediatric 0 ~ 300mmHg (0 ~ 40.0kPa) Neonate 0 ~ 140mmHg (0 ~ 18.7kPa)Initial Cuff Inflation Adult/pediatric 170±10mmHg (22.7±1.3kPa) Neonate 100±10mmHg (16.0±1.3kPa)Deflation Pressure 30mmHg(4.0kPa) higher than the last systolic pressure.Cuff Inflation Rate No greater than 50mmHg/secMeasurement Time Typical 25 seconds Maximum 40 seconds Typical Stat 20 secondsPressure Display Accuracy ±3mmHgBP Pulse Rate Accuracy ±2% @ 40 ~ 240bpm.Cuff Neonate, infant, pediatric, standard adult.Temperature (Dual Channel)Range 0 ~ 50°CProbe YSI ® 400 Skin surface or rectal /esophagealScale CelsiusAccuracy ±0.1°CResolution 0.1°CCO2Type Side stream, mom-dispersive IRCO2 Range 0-99mmHgScale mmHg/kPaAccuracy +- 2mmHg (0-40mmHg) +- 5mmHg (41-76mmHg) +-10mmHg (77-99mmHg)Calibration AutomaticRespiration Range 0-150rpm, +- 2rpmTFT Color DisplaySize 8 inchesMatrix 640 (H) x 480 (V) pixelsRecorder (Optional)Type Built-in 2-channel thermal array recorderPrint mode Text or waveformWaveforms Real time or alarm-triggeredResolution 400dpi vertical, 800dpi horizontalAnnotations Time, date, vital sign readings

Specifications subject to change without notice.

OMNI EXPRESS TECHNICAL SPECIFICATIONS

ISO 13485OMNI Express withbackside bracket option.

Page 7: 2010 Brochures

OXCYON IITABLE TOP PULSE-OXIMETER

n Accurate during motion and low perfusion

n Optional integrated printer

n Sp02, pulse rate, alarm, plethymographic waveforms display and up to 72 hours of patient trends.

n Manage data on PC via USB

n Audible and visual alarms

n 24 hour battery life, with low battery indicator

n Monitors adult, pediatrics and neonates

n Bright LCD with large digital numerics

n BCI compatible probeAdvanced, Affordable Medical Technology For The World

Adult, Pediatrics, Neonates

Page 8: 2010 Brochures

Authorized Distributor:

12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436

Web: www.infiniummedical.com • Email: [email protected]

Measurement Range

Pulse rate: 25 to 250 bpm

%SpO2: 0 to 100%

Perfusion: 0.1 to 20%

Saturation Accuracy

Without motion Adult: 70% to 100% ±2 digits

Neonates: 70% to 100% ±3 digits

With motion Adult: 70% to 100% ±3 digits

Neonates: 70% to 100% ±4 digits

Pulse Rate Accuracy

Without motion: 25 to 250 bpm ±3 digits

With motion: 25 to 250 bpm ±5 digits

Instrument

AC Power requirements: 100 to 240 VAC, 50/60Hz

Power Consumption: 24 VA

Fuse Rating: 1 Amp, 250V

Battery

Type: Li-ion

Capacity: up to 24 hours

Charging time: 5 hours

Environmental

Operating Temperature: 5ºC to 40ºC

Storage Temperature: -20ºC to 70ºC

Operating Huminity: 5% to 95%

Operation Altitude: -1,000 ft to 12,000 ft

Physical Characteristics

Weight: main 650g, adaptor 550g

Dimensions: 24.5cm x 24.5cm x 8.5cm

Equipment Classification: IEC 60601-1

EN865

EN/IEC 60601-1-2

Alarms: Audible and visual alarms for high

and low saturation, pulse rate,

sensor condition, system failure and

low battery

Display/Indicators: Type - grey / blue LCD

Pixels - 240 x 64 dots

Dot Pitch - 0.53mm

Data display: %SpO2, pulse rate, %SpO2 limits,

pulse rate limits, pleth waveform,

alarm status, trends, Battery

status, time

Output Interface: Serial USB

Trend Memory: Saturation and pulse rate memories

(72 hours maximum)

Standard Accessories: Reusable adult spo2 sensor

Option: Internal thermal printer

OXCYON II TECHNICAL SPECIFICATIONS

Page 9: 2010 Brochures

O2 SATPULSE OXIMETER

n Easy Operation by 2.8” color TFT & Touch Screen

n Large Font and Waveform Display

n Patient History Data Recall

n Two Display Directions

n Graphic and Tabular Trends

n Data Transfer and Storage to PC via USB or Bluetooth

n Continuously Adjustable Brightness

n Audio and Visual Alarm

n SpO2 Pulse-tone Modulation (Pitch Tone)Advanced, Affordable Medical Technology For The World

Neonatal, Pediatric andAdult Patients

Page 10: 2010 Brochures

Authorized Distributor:

12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436

Web: www.infiniummedical.com • Email: [email protected]

O2 SAT PULSE OXIMETER TECHNICAL SPECIFICATIONS

APPLICATIONNeonatal, pediatric and adult patients

PHYSICAL DIMENSIONS & WEIGHTBase Unit: 116.9mm H x 65.3mm W x 28.0mm DWeight: 110g without batteries

PEFORMANCE SPECIFICATIONS Display: 2.8_color TFT, touch screenResolution: 320 _ 240Trace: 1 plethysmogram waveformIndicator: Alarm indicator Power indicatorAlarm: Probe off, Finger out, Low power Modes: Visual and Audio User-adjustable High and Low limitsDisplay direction: TwoTrend storage: Min 72 hours

SPO2Measurement range: 0% ~100%Resolution: 1%Accuracy: ±2% (70~100%) Unspecified ( 0~69%)Alarm range: 50~100%Refreshing rate: 1s

PULSE RATE Range: 30 ~ 254 bpmResolution: 1bpmAccuracy: ±2 bpmAlarm range: 30~250 pbmRefreshing rate: 1s

ENVIRONMENT SPECIFICATIONSTemperature: Operating: 0_50 °C Storage: -20_65 °C Humidity: Operating: 10_90 °C non-condensing Storage: 10_95 °C non-condensing

POWERType: 3 AA AlkalineOperation time: About 9 hours for normal operation

Specifications subject to change without notice.

Page 11: 2010 Brochures

OMNIVIEWCENTRAL MONITORING SYSTEM

n Windows systemn 8 or 16 channeln Wireless or hard wiredn View up to 32 waveformsn Advanced trendingn Multi-lead ECG monitoringn Industry standard 802.11 b/g WLAN wireless connectionn Full disclosure reviewn Alarm recalln NIPB recalln Waveform and trend recordingAdvanced, Affordable Medical Technology For The World

The Infinium OmniView Includes: Complete CPU,one or two 17” Flat TFT screen, MOXA Card,Interface box, cables and connectors.

Page 12: 2010 Brochures

Authorized Distributor:

12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436

Web: www.infiniummedical.com • Email: [email protected]

MAIN FRAME

Power Supply: AC100-240V 6A/3A

Basic Configuration

17“ color TFT

Intel Pentium IV2.0G CPU

Windows XP professional operating system

512MB RAM

80GB Fixed Disk drive

PERFORMANCE

Display

Size: 17“ color TFT

Number of display: 1 or 2 sets (optional)

Resolution: 1280 x 1024

Waveform: ECG (I, II, III, aVR, aVL, aVF, V1-V6) PLETH, RESP, CO2, IBP, Multi-gas

Parameter: HR, ST, NIBP, IBP, SpO2, PR, RR, TEMP, EtCO2, Multi-Gas

Indicator

Up to 32-waveform presentation

12.5mm/s,25.0mm/s,50.0mm/s user-adjustable sweep speed

Alarm sound

Alarm

High and Low limits alarm

Audible and visual alarm

View

Up to 32 waveforms for 16 bedside monitors

All waveform presentation for single patient

48 hours of trend display for all parameters

Multi-leads ECG waveform display

Waveform freeze

Wireless Networking

Industry standard 802.11b/g WLAN

Compatible with Infinium Omni II and Omni III

Connected bedside number: up to 16 bedside monitors

Review

240 hours trend review for each bedside monitor

720 items parameters alarm review for each bedside monitor

720 NIBP measurements review

72 hours of 32 channels full-disclosure waveforms store and review

Printer

External Laser Printer

Record type

8 seconds real-time recording

Freeze waveform recording

Trend data recording

Alarm strip recording

OMNIVIEW CENTRAL MONITORING SYSTEM TECHNICAL SPECIFICATIONS

Main Display Major Monitoring Display

Page 13: 2010 Brochures

ADS IIANESTHESIA DELIVERY SYSTEM

Ventilator:

n Adult to neonatal settings

n Respiratory modes: IPPV, SIPPV, PCV, SIMV, CPAP, MANUAL

n Compliance Compensation

n I:E Ratio

n Electronic PEEP

n 10.4 inch high resolution color screen

n Easy to use operating system

n 2 hour battery backup

n Comprehensive alarmsAdvanced, Affordable Medical Technology For The World

Anesthesia Delivery System:

n Space Saving Compact design

n Sturdy yet lightweight construction for easy mobility

n Large Writing Table

n 2 large storage drawers

n Spacious monitoring shelf

n Dual flow meters (2xN20, 2xO2, 1xAir)

n Strong Back bar for fitting of 2 vaporizers

n 2 Liter Autoclavable Absorber

Page 14: 2010 Brochures

Authorized Distributor:

12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436

Web: www.infiniummedical.com • Email: [email protected]

Working Conditions:

Gas Supply O2, N2O, AIR Rated Pressure 0.4 MPa-1MPa Power AC110V-220V 50Hz-60HZ

Gas Delivery (5 tube 2xO2, 2xN2O, 1 AIR) O2 0.1 LPM-10LPM N2O 0.1 LPM-10LPM AIR 0.1 LPM-10LPM

N20/O2 hypoxic guard leaving O2 concentration >25%

Oxygen Flush 35LPM-75LPM

Vaporizer concentration 0.2%-5%

Low Oxygen alarm with N2O cutoff

Operating Conditions:

Ambient Temperature 15C-35C Relative Humidity <80% Atmospheric Pressure 960hPa-1040hPa

Storage:

Ambient Temperature -10C-40C Relative Humidity <90% Atmospheric Pressure 860hPa-1060hPa

Integrated Ventilator:

Screen Color 10.4 color TFT

Frequency adult 4-30 BPM child 20-60 BPM

Integrated Ventilator (continue):

Frequency (SIMV, SIPPV) 4-12 BPM

I:E Ratio 2:1-1:5

PEEP OFF 0.1-2kPa

Tidal volume adult 0.2-1.2 L child 0.0200.30 L

Max minute volume >18 LPM

PCV pressure OFF 0.5-6 kPa

Insp. Flow adult 10-50 LPM child 3-30 LPM

Insp. plateau OFF 5-50% w/5% increments

Insp. trigger pressure -2.0-2.0 kPa

On screen monitoring of:

Tidal Volume (Vt), Frequency (Freq), Minute Volume (MV), Gas Pressure (Peak), O2 concentration.

Comprehensive alarms for:

Tidal Volume (no volume, upper limit, lower limit) Airway Peak Pressure (upper limit and lower limit) Oxygen Concentration (upper limit lower limit) Low O2 supply with automatic N20 cut –off Power failure Low battery

ADS II - ANESTHESIA DELIVERY SYSTEM TECHNICAL SPECIFICATIONS

Gas System(Driving Gas, Air, N2O & O2)

Electrical Outlets Tank Valves(N2O & O2)

Page 15: 2010 Brochures

ADS IIIANESTHESIA DELIVERY SYSTEM

Ventilator:

n Adult, pediatric, and neonate settings

n Ventilation modes: IPPV, PCV, SIMV, PSV, MANUAL

n Compliance compensation

n Electronic PEEP

n 10.4 inch color screen

n 90 min battery backup

n Comprehensive alarms

n Comprehensive monitoringAdvanced, Affordable Medical Technology For The World

Anesthesia Delivery System:

n Stainless Steel writing table

n 3 lockable storage drawers

n GCX® Compatible mounting rails

n Selectatec type backbar for dual vaporizer fitting

n Dual flowmeter (N20, O2, AIR)

n Hypoxia safe backlit flowmeter

n 2 liter absorber with heater

n Anti-static lockable castors

n AGSS (scavenging system)

Page 16: 2010 Brochures

Authorized Distributor:

12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436

Web: www.infiniummedical.com • Email: [email protected]

Working Conditions: Gas Supply O2, N2O, AIR Rated Pressure 0.4 MPa-1MPa Power AC110V-220V 50Hz-60HZ

Gas Delivery (5 tube 2xO2, 2xN2O, 1 AIR) O2 0.1 LPM-10LPM N2O 0.1 LPM-10LPM AIR 0.1 LPM-10LPM

N20/O2 hypoxic guard leaving O2 concentration >25%

Oxygen Flush 35LPM-75LPM

Vaporizer concentration 0.2%-5%

Low Oxygen alarm with N2O cutoff

Operating Conditions: Ambient Temperature 15C-35C Relative Humidity <80% Atmospheric Pressure 960hPa-1040hPa

Storage: Ambient Temperature -10C-40C Relative Humidity <90% Atmospheric Pressure 860hPa-1060hPa

Integrated Ventilator: Screen Color 10.4 color TFT

Frequency adult 4-30 BPM child 20-60 BPM

Integrated Ventilator (continue): Frequency (SIMV, SIPPV) 4-12 BPM

I:E Ratio 4:1 – 1:5

PEEP 3-30cmH2O

Tidal volume 20-1400 ML Increment 10ML

Max minute volume >18 LPM

PCV pressure OFF 0.5-6 kPa

Insp. Flow adult 10-50 LPM child 3-30 LPM

Insp. plateau OFF 5-50% w/5% increments

Insp. trigger pressure -2.0-2.0 kPa

On screen monitoring of: Tidal Volume (Vt), Frequency (Freq), Minute Volume (MV), Gas Pressure (Peak), O2 concentration, Loops.

Comprehensive alarms for: Tidal Volume (no volume, upper limit, lower limit) Airway Peak Pressure (upper limit and lower limit) Oxygen Concentration (upper limit lower limit) Low O2 supply with automatic N20 cut –off PEEP Apnea Power failure Low battery

ADS III - ANESTHESIA DELIVERY SYSTEM TECHNICAL SPECIFICATIONS

Gas System(Driving Gas, Air, N2O & O2)

Fuse Panel

Integrated Scavenging System GCX Compatible Mounting Dual Flow Meters(2xN20, 2xO2, 2xAir)

Page 17: 2010 Brochures

ATS SurgicAl TAbleINTUITIVE MOTION / UNYIELDING STABILITY

n Silent electro-hydraulic movements

n Kidney Bridge

n Electronic control with safety lock

n Mobile anti-static castors with floor lock

n Horizontal Slide

n 180 degree rotation

n “Flex” positioning

n Easy access to electro-hydraulic system for service

n Optional battery backup

n Optional auto-reset / level function

n Optional wireless remote controlAdvanced, Affordable Medical Technology For The World

Built to the foremost standard of quality, with intuition and stability in mind the ATS surgical table is the new standard in patient positioning. The ATS surgical features a C-Arm compatible table top with a 225 KG (500 LB) lift capacity. The ATS has many advanced positioning features such as a 180 degree horizontal rotation and a horizontal slide motion to create a greater field of view for C-arm use.

Page 18: 2010 Brochures

Authorized Distributor:

12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436

Web: www.infiniummedical.com • Email: [email protected]

ATS - MulTifuncTionAl ElEcTro HydrAulic opErATing TAblE TEcHnicAl SpEcificATionS

Standard Accessories of ATSAnesthesia Frame 1 Waist Supporters 2

Shoulder Supporter 2 Square Clamp II 2

Arm Rest 2 Square Clamp I 5

Leg-Crutches 2

180˚ Rotation Horizontal Slide

Model Standard Advanced

Bed Size 2050x500mm 2150x500mm

Height 670-1100mm 600-950mm

Reverse Trendnelenburg anterversion≥30°, anterversion≥30°, retroversion≥30° retroversion≥30°

Title Left/Right leftoblique≥30°, leftoblique≥15°, rightoblique≥30° rightoblique≥15°

Chest Plate Adjustment ~ ≥25°/ ≥35°

Back Plate Adjustment +75°~ -20° +75°~ -20°

Head Plate Adjustment ≥40°/ ≥90° ≥40°/ ≥90°

Leg Plate Adjustment ≥90° ≥90°

Leg Plate Angle 0~ 90° 0~ 90°

Rotation 0~ 180° 0~ 180°

Longitudinal Shift ~ ≥350mm

Wireless Remote Controland Effective Distance ~ standard 2m

Wired Remote Control standard standard

Four-level PositionReset Function ~ standard

Emergency Power Supply ~ standard

Page 19: 2010 Brochures

InfInIum medIcalaccessorIes

Advanced, Affordable Medical Technology For The World

Standard Accessories

n 200AC Adult Cuff

n 9100 Battery

n 100L6PO 5 Lead ECG

n 20020 Cuff Hose

n 325DFS Adult Finger Sensor n 400TS Skin Temp Probe

n 9004 Grounding Cable

CO2 Accessories

n 5001SL Sample Line CO2 n 5005TA T Adapter

IBP Accessories

n 600IPC IBP Cable n 6119 Disp. IBP Transducer

Anesthetic Agent Accessories

n 5006SL Sample Line n 5007MTD Moisture Trap

Page 20: 2010 Brochures

InfInIum medIcalaccessorIes

Authorized Distributor:

12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436

Web: www.infiniummedical.com • Email: [email protected]

More Optional Accessories

n 200LAC Large Adult Cuff n 200IC Infant Cuffn 200CC Pediatric Cuff n 200NC Neonate Cuff

n 325DEC SpO2 Extension Cable n 325DYS Y Sensor n 700PPO Printer Paper

n 800RS Roll Stand n 800WM Wall Mount n 5002SCA Nasal Cannula

n 201NDC - 205NDC Disposable Neonatal Cuff (No: 1-5)