OMNI IITOUCH SCREENPATIENT MONITOR
n 12.1” color TFT display with touch screen.n Multi-lead ECG monitoringn Touch screen user interfacen NIBP list & OxyCRG dynamic view displayn Drug dose calculationsn Large font display with 4, 6 & 8 waveforms shownn Networkable with Central Monitoring System via a wireless or wired networkn S-T Segment & 72 hours trend data analysisn Compact design is convenient for mobile monitoringn Multi-lingual settingsn Optional: Dual IBP, EtCO2 and Built-in thermal recorderAdvanced, Affordable Medical Technology For The World
ECG, SPO2, NIBP, HR, TEMP, RESP.
Authorized Distributor:
12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436
Web: www.infiniummedical.com • Email: [email protected]
Physical Dimensions & WeightMain UnitDimension: 555mm H x 335mm W x 235mm DWeight: 5kg
ApplicationNeonatal, pediatric and adult patients
Operation EnvironmentPowerSource: External AC power or internal batteryAC Power: 100-240VAC, 50/60Hz, <150VABattery: Rechargeable Lead-Acid Operating time under the normal
condition: 1 hour Operating time after the first alarm of
low battery: 10 minesTemperatureWorking: 5-40˚CStorage: -20-65˚CRelative HumidityWorking: 30-75%Storage: ≤80%AltitudeOperating Altitude: Up to 5,000 metersHyperbaric Pressure: Up to 405.3 kPa
Peformance SpecificationsDisplay: 12.1” color TFT, Touch ScreenResolution: 800 x 600 pixelsTrace: 4, 6, 8 or 9 waveforms ECG (I, II, III, aVR, aVL, aVF, V1-V6),
PLETH, RESP, IBPx2, ETCO2Indicator: Alarm indicator Power indicator QRS beep and alarm soundTrend time: 72 hoursRecorder: Built-in, thermal array, 2 channels Record width: 48mm Recorder paper: 50mm Record speed: 25mm/s, 50mm/sOxyCRG: Combines HR, SPO2 and Respiration trends into a single graph
ECGInput: 5-lead ECG cable and standard AAMI
line for connectionLead Choice: I, II, III, aVR, aVF, aVL, VGain Choice: x0.125, x0.25, x0.5, x1.0, x2.0Filter: Diagnostic mode: 0.05-100Hz Monitoring mode: 0.05-75Hz Surgical mode: 1-20HzECG Waveforms: 7 channelsPenetration Voltage: 4000VAC 50/60Hz
ECG (cont.)Sweep Speed: 12.5, 25 and 50 mm/sHR Display Range: 15-300bpmAccuracy: ±1% or ±1bpm, whichever is greaterS-7 Segment Detection: 7 channelsMeasurement Range: -2.0mv - +2.0mvArrhythmia Analysis: 13 typesAlarm Limit Range Setting Upper limit: 80-400bpm Lower limit: 20-150bpm
RESPMeasure Method: RA-LL impedanceRange: 0-120 rpmAccuracy ±3 rpmAlarm Upper-lower Limit Setting: Upper limit: 6-120 rpm, Lower limit: 3-120 rpmSweep Speed: 12.5 and 25 mm/s
NIBPMeasuring Technology: Automatic oscillating measurementCuff Inflating: <30s (0-300mmHg, standard adult cuff)Measuring Period: AVE<40sMode: Manual, Auto, STATMeasuring Interval in AUTO Mode: 2 min-4 hrsPulse Rate Range: 30-250 (bpm)Measuring Range: Adult/Pediatric Mode SYS 40-250 (mmHg) DIA 15-200 (mmHg) Neonatal Mode SYS 40-135 (mmHg) DIA 15-100 (mmHg)Resolution: 1mmHgAccuracy: Pressure Maximum Mean error: ±5mmHg Maximum Standard deviation: 8mmHgOverpressure Protection: Adult Mode 280 (mmHg) Neonatal Mode 150 (mmHg)Alarm Limit Setting SYS 50-240 mmHg DIA 15-180 mmHg
TEMPRange: 0-50˚C (32-122˚F)Accuracy: Without sensorDisplay Resolution: 0.1˚CAlarm Upper-lower Limit Setting: Upper limit 0-50˚C Lower limit 0-50˚CChannel: 2 channels, provide T1, T2, ∆T
SPO2ASpO2: Anti-motion SpO2 SpO2% Range: 0-100%SpO2 Accuracy: ±2% 70-100%, non-motion ±3% 70-100%, motionPulse Rate Range: 30-250 bpmPulse Rate Accuracy: ±2 bpm (non-motion) ±3 bpm (motion)Alarm Upper-lower Limit Setting: upper limit 70-100% lower limit 70-100%SpO2 Probe Red light LED wavelength 660nm±5nm Infrared light LED wavelength 905nm±10nm
IBP (OPTION)Measurement Range: -50-300mmHgChannel: 2 channelsPressure transducer: sensitivity, 5µV/V/mmHgImpedance range: 300-3000ΩTransducer sites: ART, PA, CVP, RAP, LAP, ICPResolution: 1mmHgAccuracy: ±1mmHg or ±2%, whichever is greaterAlarm range: -50-300mmHg
EtCO2 (OPTION)Mode of Sampling: SidestreamPrinciple of Operation: Non-dispersive infrared (NDIR) single
beam optics, dual wavelength, no moving parts.
CO2 measurement Range: 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)CO2 Calculation Method: BTPS (Body Temperature Pressure Saturated)CO2 Resolution: 0.1mmHg(0-69mmHg), 0.25mmHg(70-150mmHg)CO2 Accuracy: 0-40 mmHg ± 2 mmHg 41-70 mmHg ± 5% of reading 71-100 mmHg ± 8% of reading 101-150 mmHg ± 10% of reading Above 80 breath per minute ± 12% of reading Sampling rate: 100HzRespiration Rate: 2-150 bpmRespiration Rate accuracy: ±1 breath Response Time: <3 seconds - includes transport time
and rise time Inspired CO2 measurement Range: 3-50 mmHg
Specifications subject to change without notice.
OMNI II TECHNICAL SPECIFICATIONS
Selectable Screens:4, 6 or 8 waveforms
OMNI IIIMULTI-FUNCTIONPATIENT MONITOR
n Facility to measure many parameters: ECG (3 or 5 lead) with ST segment monitoring, respiration, dual temperature monitoring, SpO2, non-invasive blood pressure.
n Up to 8 waveforms displayedn Multi-lead simultaneous ECG monitoringn Auto setting of alarm limitsn Graphical / Tabular trending n Color coded alarmsn Patient data entryn Battery backup (2 removable batteries)n Networking capabilityn Large high resolution 15 inch screenAdvanced, Affordable Medical Technology For The World
ECG, Respiration, SpO2, NIBP,
Temperature
Authorized Distributor:
12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436
Web: www.infiniummedical.com • Email: [email protected]
PHYSICAL DIMENSIONS & WEIGHTBase Unit: 309mm H×365mm W×159mm DWeight: 7.0kgs
APPLICATIONNeonatal, pediatric and adult patients
PEFORMANCE SPECIFICATIONSDisplay: 15” color TFTResolution: 1024×768Trace: 8 waveforms ECG(I, II, III, aVR, aVL, aVF, V1-V6),
PLETH, RESPIndicator: Alarm indicator Power indicator QRS beep and alarm soundTrend time: 1- 48 hoursRecorder: Built-in, thermal array, 2 channelsRecord width: 48mmRecorder paper: 50mmRecord speed: 25mm/s, 50mm/s
ECGInput: 5-lead ECG cable and standard AAMI
line for connectionLead Choice: I, II, III, aVR, aVF, aVL, V, TESTGain Choice: ×0.5, ×1, ×2Frequency Characteristic: 0.05~35 Hz (+3dB)ECG Waveforms: 7 channelsPenetration Voltage: 4000VAC 50/60HzSweep Speed: 12.5, 25 and 50 mm/sHR Display Range: 30~300bpmAccuracy: ±5%, whichever is greaterAlarm Limit Range Setting: upper limit:80~400bpm lower limit: 20~150bpm
RESPMeasure Method: RA-LL impedanceRange: 0~120 rpmAccuracy: + 3 rpmAlarm Upper-lower Limit Setting: upper limit: 6~120 rpm, lower limit: 3~120 rpmSweep Speed: 12.5 and 25 mm/s
NIBPMeasuring Technology: automatic oscillating measurementCuff Inflating: <30s (0~300 mmHg, standard adult cuff)Measuring Period: AVE<40s Mode Manual, Auto, STAT Measuring Interval in AUTO Mode 2 min~4 hrs
NIBP (continue)Pulse Rate Range: 30~250 (bpm)Measuring Range: Adult/Pediatric Mode SYS 40-250 (mmHg) DIA 15-200 (mmHg) Neonatal Mode SYS 40-135 (mmHg) DIA 15-100 (mmHg)Resolution: 1mmHg Accuracy: Pressure Maximum Mean error: ±5mmHg Maximum Standard deviation: 8mmHgOverpressure Protection: Adult Mode 280 (mmHg) Neonatal Mode 150 (mmHg)Alarm Limit Setting SYS 50~240 mmHg DIA 5~180 mmHg
TEMPRange: 25~50 (ºC)Accuracy: ±0.2ºC (25.0~34.9 ºC) ±0.1ºC (35.0~39.9 ºC) ±0.2ºC (40.0~44.9 ºC) ±0.3ºC (45.0~50.0 ºC)Display Resolution: 0.1 ºCAlarm Upper-lower Limit Setting upper limit 0~50 ºC, lower limit 0~50 ºCChannel: 2 channelsAlarm Limit Setting: 10~50 ºC
SPO2ASpO2: Anti-motion SpO2SpO2% Range: 0-100%SpO2 Accuracy: ±2% (70~100%, non-motion) ±3% (70~100%, motion)Pulse Rate Range: 30-250 bpmPulse Rate Accuracy: ±2 bpm ±3 bpm (motion)Alarm Upper-lower Limit Setting upper limit 70~100%, lower limit 70~100%SpO2 Probe Red light LED wavelength 660nm±5nm Infrared light LED wavelength 940nm±10nm
NETWORKINGIndustry standard 802.11b/g wireless network Frequency Range: 2.412 – 2.484 GHz Connected bedside number: up to 8 bedside monitors
POWERSource: External AC power or internal batteryAC Power: 100-240VAC, 50/60Hz, 150VABattery: Built-in and rechargeableCharge Time: 4 hoursOperating Time: 1 hour
ENVIRONMENTAL SPECIFICATIONSTemperature: Operating: 5~40 °C Storage: -10~45 °CHumidity range: Operating: ≤80 % Storage: ≤80 %
BATTERYRechargeable Lead-AcidOperating time under the normal condition - 1 hourOperating time after the first alarm of low battery - 10 minutes
RECORDER (OPTION)Record Width 48 (mm)Paper Speed 25 (mm/S)Trace 2
FUSE (SELF-RECOVERY)Input fuse: 3.15A/250V
LIFETIME8 Years
OMNI III TECHNICAL SPECIFICATIONS
The Omni III patient monitor delivers the best performance and flexibility for the price. The Omni III features a large 15” high resolution screen while still remaining light and portable.
OMNI ExprEssPORTABLE PATIENT MONITOR
n Touch Screen
n 3 waveforms displayed
n Simultaneous multi-lead ECG monitoring
n Battery backup
n Graphical and tabular trending
n Audible and visual alarms
n Advanced ST and arrhythmia detection
n Quick BP readings recall
n Optional EtCo2
n Optional printerAdvanced, Affordable Medical Technology For The World
ECG, Respiration, SpO2, NIBP, Temperature,
Recorder
Authorized Distributor:
12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436
Web: www.infiniummedical.com • Email: [email protected]
Safety Approval & Quality SystemDesigned to meet IEC60601-1-1988, EN60601-1-1, EN60601-2Class II Equipment, double insulatedType BF applied parts ISO9001 & EN46001 CertifiedPower RequirementsPower Supply AC 90-264V/47-63HzInput Power ≤55VAFuses Two fuse sockets in the rear panel indicated by “FUSE”,
IO5X20, 2A/250VBattery 12V/4.0AH sealed lead-acidCharge time ≥4 hoursOperating time ≥2 hours (full recharge)Battery Charging Method Automatic charging after monitor is connected to AC power
supply (with charge protection function)Discharge Protection When powered by battery, the monitor will be automatically
turned off when battery power is almost used up.
Performance SpecificationsECG Patient Safety Standard IEC60601-1-1988CMRR ≥60dB (Common Mode Rejection Ratio)Heart Rate Range 20 ~ 254bpm ± 1bpmHeart Rate Averaging 8 second averageST Segment Range -0.8 ~ + 0.8mVInterface AAMI 6-pinLead Selection I, II, III (3 lead mode) I, II, III, aVR, aVL, aVF, V (5 lead mode) (ST and
Arrhythmia analysis) Lead Fault Alarm Audible, Visual Input 5-lead ECG patient cableQRS Indicator Audible and Visual AlertWaveform Storage 6 minutesSweep Speed 12.5/25/50 mm/secGain Selection 4mV, 2mV, 1mV, 0.5mV, 0.25mV,AutoTrends 2 hours ➔ 4 hours ➔ 8 hours ➔ 24 hours ➔ 48 hoursPatient Isolation Breakdown voltage: 4000VAC 50Hz 60 seconds Leakage current: <10µAFrequency width Monitoring mode: 0.5 ~ 40Hz (+0.4dB,-3.0dB) Surgery mode: 0.5 ~ 20Hz (+0.4dB, -3.0dB)
(not calibration significant)Patient Drive Current <10µAEnclosure Leakage Current <0.1mAMaximum T Wave Rejection Capability 1.2mVHeart Rate Alarm Response Time < 7 secondsAspect Ratio 0.24 ~ 0.6 sec/mVAlarm Frequency Low alarm 2-2.4kHz High alarm 3-3.4kHzDefibrillator Protected & ESIS Protected Tested with 5kVRecovery Time Following Defibrillation <5 secondsRespirationMeasurement Method Thoracic ImpedanceRespiration Rate Range 0 ~ 100±1rpmAccuracy ±2 rpm
Pulse Oximetry (SpO2) SpO2 Range 0-100% Adult/Pediatric/NeonateSpO2 Averaging 8 second averageSpO2 Accuracy ±2% (70 ~ 100%), ±3% (40 ~ 70%)Pulse Rate Range 30 ~ 250bpmPulse Rate Averaging 8 beat averagePulse Rate Accuracy ±1% @ 30 ~ 100bpmSensor Types Finger, Universal “Y”, wrap probesPulse Rate Display DigitalNon-Invasive Blood Pressure ( NIBP )Method Automatic oscillometricParameters Systolic, diastolic, mean arterial pressure, pulseScale mmHg or kPaOperating Modes Manual, Automatic, ContinuousRepeat Cycles 1 ~ 10, 15, 30, 60, 90, 120 minutesDetermination - Systolic Adult/pediatric 40 ~ 250mmHg (5.3 ~ 33.3kPa) Neonate 20 ~ 160mmHg (2.7 ~ 21.3kPa) - Diastolic Adult/pediatric 10 ~ 180mmHg (1.3 ~ 24.0kPa) Neonate 10 ~ 140mmHg (1.3 ~ 18.7kPa)Cuff Pressure Range Adult/pediatric 0 ~ 300mmHg (0 ~ 40.0kPa) Neonate 0 ~ 140mmHg (0 ~ 18.7kPa)Initial Cuff Inflation Adult/pediatric 170±10mmHg (22.7±1.3kPa) Neonate 100±10mmHg (16.0±1.3kPa)Deflation Pressure 30mmHg(4.0kPa) higher than the last systolic pressure.Cuff Inflation Rate No greater than 50mmHg/secMeasurement Time Typical 25 seconds Maximum 40 seconds Typical Stat 20 secondsPressure Display Accuracy ±3mmHgBP Pulse Rate Accuracy ±2% @ 40 ~ 240bpm.Cuff Neonate, infant, pediatric, standard adult.Temperature (Dual Channel)Range 0 ~ 50°CProbe YSI ® 400 Skin surface or rectal /esophagealScale CelsiusAccuracy ±0.1°CResolution 0.1°CCO2Type Side stream, mom-dispersive IRCO2 Range 0-99mmHgScale mmHg/kPaAccuracy +- 2mmHg (0-40mmHg) +- 5mmHg (41-76mmHg) +-10mmHg (77-99mmHg)Calibration AutomaticRespiration Range 0-150rpm, +- 2rpmTFT Color DisplaySize 8 inchesMatrix 640 (H) x 480 (V) pixelsRecorder (Optional)Type Built-in 2-channel thermal array recorderPrint mode Text or waveformWaveforms Real time or alarm-triggeredResolution 400dpi vertical, 800dpi horizontalAnnotations Time, date, vital sign readings
Specifications subject to change without notice.
OMNI EXPRESS TECHNICAL SPECIFICATIONS
ISO 13485OMNI Express withbackside bracket option.
OXCYON IITABLE TOP PULSE-OXIMETER
n Accurate during motion and low perfusion
n Optional integrated printer
n Sp02, pulse rate, alarm, plethymographic waveforms display and up to 72 hours of patient trends.
n Manage data on PC via USB
n Audible and visual alarms
n 24 hour battery life, with low battery indicator
n Monitors adult, pediatrics and neonates
n Bright LCD with large digital numerics
n BCI compatible probeAdvanced, Affordable Medical Technology For The World
Adult, Pediatrics, Neonates
Authorized Distributor:
12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436
Web: www.infiniummedical.com • Email: [email protected]
Measurement Range
Pulse rate: 25 to 250 bpm
%SpO2: 0 to 100%
Perfusion: 0.1 to 20%
Saturation Accuracy
Without motion Adult: 70% to 100% ±2 digits
Neonates: 70% to 100% ±3 digits
With motion Adult: 70% to 100% ±3 digits
Neonates: 70% to 100% ±4 digits
Pulse Rate Accuracy
Without motion: 25 to 250 bpm ±3 digits
With motion: 25 to 250 bpm ±5 digits
Instrument
AC Power requirements: 100 to 240 VAC, 50/60Hz
Power Consumption: 24 VA
Fuse Rating: 1 Amp, 250V
Battery
Type: Li-ion
Capacity: up to 24 hours
Charging time: 5 hours
Environmental
Operating Temperature: 5ºC to 40ºC
Storage Temperature: -20ºC to 70ºC
Operating Huminity: 5% to 95%
Operation Altitude: -1,000 ft to 12,000 ft
Physical Characteristics
Weight: main 650g, adaptor 550g
Dimensions: 24.5cm x 24.5cm x 8.5cm
Equipment Classification: IEC 60601-1
EN865
EN/IEC 60601-1-2
Alarms: Audible and visual alarms for high
and low saturation, pulse rate,
sensor condition, system failure and
low battery
Display/Indicators: Type - grey / blue LCD
Pixels - 240 x 64 dots
Dot Pitch - 0.53mm
Data display: %SpO2, pulse rate, %SpO2 limits,
pulse rate limits, pleth waveform,
alarm status, trends, Battery
status, time
Output Interface: Serial USB
Trend Memory: Saturation and pulse rate memories
(72 hours maximum)
Standard Accessories: Reusable adult spo2 sensor
Option: Internal thermal printer
OXCYON II TECHNICAL SPECIFICATIONS
O2 SATPULSE OXIMETER
n Easy Operation by 2.8” color TFT & Touch Screen
n Large Font and Waveform Display
n Patient History Data Recall
n Two Display Directions
n Graphic and Tabular Trends
n Data Transfer and Storage to PC via USB or Bluetooth
n Continuously Adjustable Brightness
n Audio and Visual Alarm
n SpO2 Pulse-tone Modulation (Pitch Tone)Advanced, Affordable Medical Technology For The World
Neonatal, Pediatric andAdult Patients
Authorized Distributor:
12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436
Web: www.infiniummedical.com • Email: [email protected]
O2 SAT PULSE OXIMETER TECHNICAL SPECIFICATIONS
APPLICATIONNeonatal, pediatric and adult patients
PHYSICAL DIMENSIONS & WEIGHTBase Unit: 116.9mm H x 65.3mm W x 28.0mm DWeight: 110g without batteries
PEFORMANCE SPECIFICATIONS Display: 2.8_color TFT, touch screenResolution: 320 _ 240Trace: 1 plethysmogram waveformIndicator: Alarm indicator Power indicatorAlarm: Probe off, Finger out, Low power Modes: Visual and Audio User-adjustable High and Low limitsDisplay direction: TwoTrend storage: Min 72 hours
SPO2Measurement range: 0% ~100%Resolution: 1%Accuracy: ±2% (70~100%) Unspecified ( 0~69%)Alarm range: 50~100%Refreshing rate: 1s
PULSE RATE Range: 30 ~ 254 bpmResolution: 1bpmAccuracy: ±2 bpmAlarm range: 30~250 pbmRefreshing rate: 1s
ENVIRONMENT SPECIFICATIONSTemperature: Operating: 0_50 °C Storage: -20_65 °C Humidity: Operating: 10_90 °C non-condensing Storage: 10_95 °C non-condensing
POWERType: 3 AA AlkalineOperation time: About 9 hours for normal operation
Specifications subject to change without notice.
OMNIVIEWCENTRAL MONITORING SYSTEM
n Windows systemn 8 or 16 channeln Wireless or hard wiredn View up to 32 waveformsn Advanced trendingn Multi-lead ECG monitoringn Industry standard 802.11 b/g WLAN wireless connectionn Full disclosure reviewn Alarm recalln NIPB recalln Waveform and trend recordingAdvanced, Affordable Medical Technology For The World
The Infinium OmniView Includes: Complete CPU,one or two 17” Flat TFT screen, MOXA Card,Interface box, cables and connectors.
Authorized Distributor:
12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436
Web: www.infiniummedical.com • Email: [email protected]
MAIN FRAME
Power Supply: AC100-240V 6A/3A
Basic Configuration
17“ color TFT
Intel Pentium IV2.0G CPU
Windows XP professional operating system
512MB RAM
80GB Fixed Disk drive
PERFORMANCE
Display
Size: 17“ color TFT
Number of display: 1 or 2 sets (optional)
Resolution: 1280 x 1024
Waveform: ECG (I, II, III, aVR, aVL, aVF, V1-V6) PLETH, RESP, CO2, IBP, Multi-gas
Parameter: HR, ST, NIBP, IBP, SpO2, PR, RR, TEMP, EtCO2, Multi-Gas
Indicator
Up to 32-waveform presentation
12.5mm/s,25.0mm/s,50.0mm/s user-adjustable sweep speed
Alarm sound
Alarm
High and Low limits alarm
Audible and visual alarm
View
Up to 32 waveforms for 16 bedside monitors
All waveform presentation for single patient
48 hours of trend display for all parameters
Multi-leads ECG waveform display
Waveform freeze
Wireless Networking
Industry standard 802.11b/g WLAN
Compatible with Infinium Omni II and Omni III
Connected bedside number: up to 16 bedside monitors
Review
240 hours trend review for each bedside monitor
720 items parameters alarm review for each bedside monitor
720 NIBP measurements review
72 hours of 32 channels full-disclosure waveforms store and review
Printer
External Laser Printer
Record type
8 seconds real-time recording
Freeze waveform recording
Trend data recording
Alarm strip recording
OMNIVIEW CENTRAL MONITORING SYSTEM TECHNICAL SPECIFICATIONS
Main Display Major Monitoring Display
ADS IIANESTHESIA DELIVERY SYSTEM
Ventilator:
n Adult to neonatal settings
n Respiratory modes: IPPV, SIPPV, PCV, SIMV, CPAP, MANUAL
n Compliance Compensation
n I:E Ratio
n Electronic PEEP
n 10.4 inch high resolution color screen
n Easy to use operating system
n 2 hour battery backup
n Comprehensive alarmsAdvanced, Affordable Medical Technology For The World
Anesthesia Delivery System:
n Space Saving Compact design
n Sturdy yet lightweight construction for easy mobility
n Large Writing Table
n 2 large storage drawers
n Spacious monitoring shelf
n Dual flow meters (2xN20, 2xO2, 1xAir)
n Strong Back bar for fitting of 2 vaporizers
n 2 Liter Autoclavable Absorber
Authorized Distributor:
12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436
Web: www.infiniummedical.com • Email: [email protected]
Working Conditions:
Gas Supply O2, N2O, AIR Rated Pressure 0.4 MPa-1MPa Power AC110V-220V 50Hz-60HZ
Gas Delivery (5 tube 2xO2, 2xN2O, 1 AIR) O2 0.1 LPM-10LPM N2O 0.1 LPM-10LPM AIR 0.1 LPM-10LPM
N20/O2 hypoxic guard leaving O2 concentration >25%
Oxygen Flush 35LPM-75LPM
Vaporizer concentration 0.2%-5%
Low Oxygen alarm with N2O cutoff
Operating Conditions:
Ambient Temperature 15C-35C Relative Humidity <80% Atmospheric Pressure 960hPa-1040hPa
Storage:
Ambient Temperature -10C-40C Relative Humidity <90% Atmospheric Pressure 860hPa-1060hPa
Integrated Ventilator:
Screen Color 10.4 color TFT
Frequency adult 4-30 BPM child 20-60 BPM
Integrated Ventilator (continue):
Frequency (SIMV, SIPPV) 4-12 BPM
I:E Ratio 2:1-1:5
PEEP OFF 0.1-2kPa
Tidal volume adult 0.2-1.2 L child 0.0200.30 L
Max minute volume >18 LPM
PCV pressure OFF 0.5-6 kPa
Insp. Flow adult 10-50 LPM child 3-30 LPM
Insp. plateau OFF 5-50% w/5% increments
Insp. trigger pressure -2.0-2.0 kPa
On screen monitoring of:
Tidal Volume (Vt), Frequency (Freq), Minute Volume (MV), Gas Pressure (Peak), O2 concentration.
Comprehensive alarms for:
Tidal Volume (no volume, upper limit, lower limit) Airway Peak Pressure (upper limit and lower limit) Oxygen Concentration (upper limit lower limit) Low O2 supply with automatic N20 cut –off Power failure Low battery
ADS II - ANESTHESIA DELIVERY SYSTEM TECHNICAL SPECIFICATIONS
Gas System(Driving Gas, Air, N2O & O2)
Electrical Outlets Tank Valves(N2O & O2)
ADS IIIANESTHESIA DELIVERY SYSTEM
Ventilator:
n Adult, pediatric, and neonate settings
n Ventilation modes: IPPV, PCV, SIMV, PSV, MANUAL
n Compliance compensation
n Electronic PEEP
n 10.4 inch color screen
n 90 min battery backup
n Comprehensive alarms
n Comprehensive monitoringAdvanced, Affordable Medical Technology For The World
Anesthesia Delivery System:
n Stainless Steel writing table
n 3 lockable storage drawers
n GCX® Compatible mounting rails
n Selectatec type backbar for dual vaporizer fitting
n Dual flowmeter (N20, O2, AIR)
n Hypoxia safe backlit flowmeter
n 2 liter absorber with heater
n Anti-static lockable castors
n AGSS (scavenging system)
Authorized Distributor:
12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436
Web: www.infiniummedical.com • Email: [email protected]
Working Conditions: Gas Supply O2, N2O, AIR Rated Pressure 0.4 MPa-1MPa Power AC110V-220V 50Hz-60HZ
Gas Delivery (5 tube 2xO2, 2xN2O, 1 AIR) O2 0.1 LPM-10LPM N2O 0.1 LPM-10LPM AIR 0.1 LPM-10LPM
N20/O2 hypoxic guard leaving O2 concentration >25%
Oxygen Flush 35LPM-75LPM
Vaporizer concentration 0.2%-5%
Low Oxygen alarm with N2O cutoff
Operating Conditions: Ambient Temperature 15C-35C Relative Humidity <80% Atmospheric Pressure 960hPa-1040hPa
Storage: Ambient Temperature -10C-40C Relative Humidity <90% Atmospheric Pressure 860hPa-1060hPa
Integrated Ventilator: Screen Color 10.4 color TFT
Frequency adult 4-30 BPM child 20-60 BPM
Integrated Ventilator (continue): Frequency (SIMV, SIPPV) 4-12 BPM
I:E Ratio 4:1 – 1:5
PEEP 3-30cmH2O
Tidal volume 20-1400 ML Increment 10ML
Max minute volume >18 LPM
PCV pressure OFF 0.5-6 kPa
Insp. Flow adult 10-50 LPM child 3-30 LPM
Insp. plateau OFF 5-50% w/5% increments
Insp. trigger pressure -2.0-2.0 kPa
On screen monitoring of: Tidal Volume (Vt), Frequency (Freq), Minute Volume (MV), Gas Pressure (Peak), O2 concentration, Loops.
Comprehensive alarms for: Tidal Volume (no volume, upper limit, lower limit) Airway Peak Pressure (upper limit and lower limit) Oxygen Concentration (upper limit lower limit) Low O2 supply with automatic N20 cut –off PEEP Apnea Power failure Low battery
ADS III - ANESTHESIA DELIVERY SYSTEM TECHNICAL SPECIFICATIONS
Gas System(Driving Gas, Air, N2O & O2)
Fuse Panel
Integrated Scavenging System GCX Compatible Mounting Dual Flow Meters(2xN20, 2xO2, 2xAir)
ATS SurgicAl TAbleINTUITIVE MOTION / UNYIELDING STABILITY
n Silent electro-hydraulic movements
n Kidney Bridge
n Electronic control with safety lock
n Mobile anti-static castors with floor lock
n Horizontal Slide
n 180 degree rotation
n “Flex” positioning
n Easy access to electro-hydraulic system for service
n Optional battery backup
n Optional auto-reset / level function
n Optional wireless remote controlAdvanced, Affordable Medical Technology For The World
Built to the foremost standard of quality, with intuition and stability in mind the ATS surgical table is the new standard in patient positioning. The ATS surgical features a C-Arm compatible table top with a 225 KG (500 LB) lift capacity. The ATS has many advanced positioning features such as a 180 degree horizontal rotation and a horizontal slide motion to create a greater field of view for C-arm use.
Authorized Distributor:
12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436
Web: www.infiniummedical.com • Email: [email protected]
ATS - MulTifuncTionAl ElEcTro HydrAulic opErATing TAblE TEcHnicAl SpEcificATionS
Standard Accessories of ATSAnesthesia Frame 1 Waist Supporters 2
Shoulder Supporter 2 Square Clamp II 2
Arm Rest 2 Square Clamp I 5
Leg-Crutches 2
180˚ Rotation Horizontal Slide
Model Standard Advanced
Bed Size 2050x500mm 2150x500mm
Height 670-1100mm 600-950mm
Reverse Trendnelenburg anterversion≥30°, anterversion≥30°, retroversion≥30° retroversion≥30°
Title Left/Right leftoblique≥30°, leftoblique≥15°, rightoblique≥30° rightoblique≥15°
Chest Plate Adjustment ~ ≥25°/ ≥35°
Back Plate Adjustment +75°~ -20° +75°~ -20°
Head Plate Adjustment ≥40°/ ≥90° ≥40°/ ≥90°
Leg Plate Adjustment ≥90° ≥90°
Leg Plate Angle 0~ 90° 0~ 90°
Rotation 0~ 180° 0~ 180°
Longitudinal Shift ~ ≥350mm
Wireless Remote Controland Effective Distance ~ standard 2m
Wired Remote Control standard standard
Four-level PositionReset Function ~ standard
Emergency Power Supply ~ standard
InfInIum medIcalaccessorIes
Advanced, Affordable Medical Technology For The World
Standard Accessories
n 200AC Adult Cuff
n 9100 Battery
n 100L6PO 5 Lead ECG
n 20020 Cuff Hose
n 325DFS Adult Finger Sensor n 400TS Skin Temp Probe
n 9004 Grounding Cable
CO2 Accessories
n 5001SL Sample Line CO2 n 5005TA T Adapter
IBP Accessories
n 600IPC IBP Cable n 6119 Disp. IBP Transducer
Anesthetic Agent Accessories
n 5006SL Sample Line n 5007MTD Moisture Trap
InfInIum medIcalaccessorIes
Authorized Distributor:
12151 62nd St N #5 • Largo FL 33773 • USAPhone: (1) 727-531-8434 • Fax: (1) 727-531-8436
Web: www.infiniummedical.com • Email: [email protected]
More Optional Accessories
n 200LAC Large Adult Cuff n 200IC Infant Cuffn 200CC Pediatric Cuff n 200NC Neonate Cuff
n 325DEC SpO2 Extension Cable n 325DYS Y Sensor n 700PPO Printer Paper
n 800RS Roll Stand n 800WM Wall Mount n 5002SCA Nasal Cannula
n 201NDC - 205NDC Disposable Neonatal Cuff (No: 1-5)