2011 inverter cassette brochure

2
Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. Inverter In-Ceiling Cassette LG AIR CONDITIONERS Optional (PQWRHDF0) Wireless Remote Controller PQRCVSL0QW • Easy to read large font • Large wide LCD • Easy installation The wired remote controller with a large wide LCD screen featuring large font letters and easy key design enables the user more convenient control of operational conditions of the indoor unit. 2 remote control in 1 indoor unit. Order 1 more wired remote control (PQRCVSL0QW). New Wired Remote Controller We at LG are committed to making the lives of our customers more comfortable. Through continuous improvement in R&D and innovation to enhance energy efficiency, LG introduces the new H-Inverter, an energy efficient, quiet unit giving you and your business ultimate comfort. Life is Good with LG High Efficiency Inverter The LG inverter air conditioner comes with a BLDC compressor that uses a strong neodymium magnet. Its compressor thus has improved efficiency compared with the AC inverter. Powerful BLDC Compressor 1 2 4 5 3 Minimized Oil circulation High Efficiency Motor Optimize Compression Efficiency Optimize Vibration, Noise High Reliability 1 2 3 4 5 With the advancement of inverter technology comes more quiet, economical and powerful air conditioning systems. The LG air conditioner is manufactured using PFC and sine wave technology. DC Inverter Technology Step-up Inverter using PFC & Sine Wave Control Technology (PFC : Power Factor Correction)compared to conventional. DC 280V Partial switching Full range Sine wave switching DC 380V (Boost up) Loss Full range • Sine wave Control in BLDC Compressor • PFC Control in Power Input The Brushless DC (BLDC) fan motor offers additional energy savings as it is more efficient that an AC motor. The efficiency gain varies with output velocity, at full velocity an energy saving of up to 20% is achieved. BLDC Fan Technology 100 80 60 40 20 0 200 300 400 500 600 700 800 900 1000 DC motor AC motor Approx 20% increase Approx 40% increase Efficiency(%) Motor Speed(rpm) Night Quiet Operation is a control feature designed to reduce the noise level of the outdoor unit at night. The feature is activated via a dip switch on the outdoor PCB. *Model UU18WH has the lowest Night Quiet noise level 48dB 39dB Night Quiet Operation Noise Level [dB(A)] Day time Night Quiet UU12WH UU21WH UU24WH Nois 52 Day t 52 52 UU36WH UU42WH UU48WH UU12WH UU21WH UU24WH UU36WH UU42WH UU48WH time 52 55 45 Night 45 44 t Quiet 4 4 47 Day time Night Quiet 840x204x840 950x25x950 35/33/31 52 3.54 4.04 840x204x840 950x25x950 39/37/34 48 3.70 4.07 840v246x840 950x25x950 40/38/36 52 3.92 4.22 840v246x840 950x25x950 40/38/36 52 3.65 4.15 840x288x840 950x25x950 47/45/42 55 3.85 4.47 840x288x840 950x25x950 47/45/42 55 3.41 4.11 840x288x840 950x 25x950 47/45/42 55 3.23 3.81 3.5/4.2 5.0/5.5 6.0/7.0 7.0/8.0 10.0/11.2 12.5/14.0 13.4/15.5 UT12Q Indoor: UTN12WH Outdoor: UU12WH Front Panel: PT-UMC UT18Q Indoor: UTN18WH Outdoor: UU18WH Front Panel: PT-UMC UT21Q Indoor: UTN21WH Outdoor: UU21WH Front Panel: PT-UMC UT24Q Indoor: UTN24WH Outdoor: UU24WH Front Panel: PT-UMC UT36Q Indoor: UTN36WH Outdoor: UU36WH Front Panel: PT-UMC UT42Q Indoor: UTN42WH Outdoor: UU42WH Front Panel: PT-UMC UT48Q Indoor: UTN48WH Outdoor: UU48WH Front Panel: PT-UMC Package Model Dimension(mm) Indoor Unit Decoration Panel Sound Pressure(dB(A)±3) Indoor(H/M/L) Outdoor Capacity(kW) Cooling / Heating Indoor Unit OutdoorUnit EER/COP(W/W) Cooling Heating The LG H-Inverter series has achieved high system efficiency in both Cooling and Heading modes through the use of BLDC Compressor & Fan motors and the use of DC Inverter technology. This has resulted in most models* achieving a heating COP of 4.0 *Except model UT48Q that achieved a COP of 3.81 High Efficiency LG H-Inverter A Company B Company 4.47 3.85 3.96 3.57 3.76 3.14 Cooling Heating *Based on UT36Q. Specifications Set Name UT12Q UT18Q UT21Q UT24Q UT36Q UT42Q UT48Q Indoor UTN12WH UTN18WH UTN21WH UTN24WH UTN36WH UTN42WH UTN48WH Front Panel PT-UMC PT-UMC PT-UMC PT-UMC PT-UMC PT-UMC PT-UMC Power Supply Ø/V/Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 Capacity Cooling kw 1.4 ~ 3.5 ~ 4.2 2.0 ~ 5.0 ~ 5.5 2.8 ~ 6.0 ~ 8.0 2.8 ~ 7.0 ~ 8.4 4.5 ~ 10.0 ~ 13.0 5.0 ~ 12.5 ~ 14.9 5.5 ~ 13.4 ~ 16.0 Heating kw 1.6 ~ 4.2 ~ 5.0 2.2 ~ 5.5 ~ 6.05 3.2 ~ 7.0 ~ 9.0 3.2 ~ 8.0 ~ 9.4 4.9 ~ 11.2 ~ 14.0 5.5 ~ 14.0 ~ 16.8 6.4 ~ 15.5 ~ 17.9 Current Nominal running A 0.6 0.6 0.6 0.6 0.72 0.72 0.72 Fan Motor Output x Number of Unit 60 x 1 60 x 1 124 x 1 124 x 1 124 x 1 124 x 1 124 x 1 Air Flow Rate(H/M/L) CMM 13/12/10 17/15/13 21/18/16 21/18/16 32/26.1/20.2 32/26.7/21.5 32/27.4/22.8 CFM 445/410/340 582/519/459 742/636/565 742/636/565 1130/922/713 1130/943/759 1130/968/805 Coil Coil Row x Column x FPI mm 2Rx8Cx19FPI 2Rx8Cx19FPI 2Rx10Cx19FPI 2Rx10Cx19FPI 2Rx12Cx19FPI/ 1Rx10Cx19FPI 2Rx12Cx19FPI/ 1Rx10Cx19FPI 2Rx12Cx19FPI/ 1Rx10Cx19FPI Dimensions (WxHxD) Body mm 840x204x840 840x204x840 840v246x840 840v246x840 840x288x840 840x288x840 840x288x840 Decorative Panel mm 950x25x950 950x25x950 950x25x950 950x25x950 950x25x950 950x25x950 950x 25x950 Weight Body kg 21 21 23.5 23.5 28 28 28 Decorative Panel kg 5 5 5 5 5 5 5 Sound Level (H/M/L) dB(A)+3 35/33/31 39/37/34 40/38/36 40/38/36 47/45/42 47/45/42 47/45/42 Piping Connections Liquid(Ø) mm 6.35 6.35 9.52 9.52 9.52 9.52 9.52 Gas(Ø) mm 9.52 12.7 15.88 15.88 15.88 15.88 15.88 Drain(OD/ID) mm 32/25 32/25 32/25 32/25 32/25 32/25 32/25 Dehumidification Rate l/h 1.3 2.1 2.7 2.7 2.7 3.6 3.6 Referigerant R410A R410A R410A R410A R410A R410A R410A Power and transmission interunit cable No.*mm² 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 Outdoor UU12WH UU18WH UU21WH UU24WH UU36WH UU42WH UU48WH Running Current Cooling A 4.4 6.0 7.6 9.5 11.5 16.8 18.7 Heating A 4.6 6.7 7.7 9.0 11.3 15.0 18.0 Power Supply Ø,V,Hz 1 , 220-240 , 50 1 , 220-240 , 50 1 , 220-240 , 50 1 , 220-240 , 50 1 , 220-240 , 50 1 , 220-240 , 50 1 , 220-240 , 50 Power Supply Cable (includes earth) No.*mm² 3 x 2.5 3 x 2.5 3 x 2.5 3 x 2.5 3 x 5.0 3 x 5.0 3 x 5.0 Interunit Cable (includes earth) No.*mm² 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 Dimensions W x H x D mm 870x655x320 870x808x320 950x834x330 950v834x330 950 x 1380 x 330 950 x 1380 x 330 950 x 1380 x 330 Net Weight kg 46 58 63 63 103 103 103 Compressor Oil Charge cc 570 900 900 900 1 300 1 300 1 300 Oil Type FVC68D FVC68D FVC68D FVC68D FVC68D FVC68D FVC68D Refrigerant Cycle Charge(at 5m) g(oz) 1 250(44.16) 2 000(70.6) 2 200(77.6) 2 200(77.6) 3600(127) 3600(127) 3600(127) Additional Refrigerant Charge(over 10m) g/m 20 20 40 40 40 40 40 Heat Exchange Tube Size(OD) mm 7.0 7.0 7.0 7.0 7.0 7.0 7.0 Fan motor Output kW 0.083 0.124 0.124 0.124 0.124 0.124 0.124 Fan Discharge Side/Top Side Discharge Side Discharge Side Discharge Side Discharge Side discharge Side discharge Side discharge Air Circulation CMM(CFM) 50(1766) 58(2048) 58(2048) 58(2048) 55(1942) x 2 55(1942) x 2 55(1942) x 2 Sound Level Night quiet Sound Pressure dB(A)±3 45 39 44 44 47 47 47 Sound pressure level dB(A)±3 52 48 52 52 55 55 55 Sound power level at 1.5m dBA±3 66 62 67 67 71 71 71 Piping connection Liquid(Ø) mm 6.35 6.35 9.52 9.52 9.52 9.52 9.52 Gas(Ø) mm 9.52 12.7 15.88 15.88 15.88 15.88 15.88 Drain(OD/ID) mm 17/13 17/13 17/13 17/13 17/13 17/13 17/13 Max. Piping Length/Elevation m 30/20 50/30 50/30 50/30 75/30 75/30 75/30 Operational Temperature Range Cooling °CDB -10 ~ 48 -10 ~ 48 -10 ~ 48 -10 ~ 48 -10 ~ 48 -10 ~ 48 -10 ~ 48 Heating °CDB -15 ~ 24 -15 ~ 24 -15 ~ 24 -15 ~ 24 -15 ~ 24 -15 ~ 24 -15 ~ 24 AUS-CST1101 New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : 02-8805-4000 FAX : 02-8805-4248 Customer information Centre is available 7AM-7PM on 1300 54 2273 (1300 LG CARE) www.lg.com.au/airconditioning Western Australia Unit 1/1A 2 Business Way Malaga 6090 PO Box 1724 Malaga WA 6944 PH : 08-9249-3721 FAX : 08-9249-1300 Queensland 23 Terrace Place MURARRIE QLD 4172 PH : 07-3908-9000 FAX : 07-3399-4179 New Zealand Unit A, 38 Highbrooke Drive, East Tamaki, 2013 New Zealand PH : +64 (09) 914-2444 FAX : +64 (09) 914-2441 Customer Service Helpline 0800 54 2273 (0800 LG CARE) www.lg.co.nz South Australia 91 Transport Avenue NETLEY SA 5037 PH : 08-8238-0200 FAX : 08-8238-0299 Victoria 3 John Deere Court, Parkwest Estate DERRIMUT VIC 3030 PH : 03-8369-0900 FAX : 03-9931-0677 Note : • Due to our policy of innovation some specifications may be changed without notification. • Actual cooling & heating capacity will vary as ambient temperature decreases. Please consult your LG sales representative for performance data outside of AS3823.1.2. standard conditions. • Sound level are determined in an anachoic chamber at a distance of 1 m. Actual installed noise levels will vary depending on the installed location. • Information contained in this brochure is a guide only and LG strongly recommends that you ask for advice from specialist installers and retailers, who can assist with measuring rooms and testing. Specialists can tell you the best size and type of air conditioner suited for your needs. * Auto changeover is not operable when using the fresh air interlock feature. Features • Air supply outlet - 4 • Airflow direction control(up & down) - auto • Auto swing(up & down) • Airflow steps(fan/cool/heat) - 4/5/4 • Chaos wind(auto wind) • Jet cool(Power wind) • Swirl wind • Plasma air purifier - PTPKM0 • Prefilter(washable / anti-fungus) • Drain pump • E.S.P. control • High ceiling operation • Hot start • Self diagnosis • Soft dry operation • Auto changeover • Auto Elevation Grille - PTEGM0 • Auto restart operation • Child lock • Forced operation • Group control • Sleep mode • Timer(on/off) • Timer(weekly) • Two thermistor control • Dry contact - PQDSB • Wide Character wired remote controller, Picto wired remote controller - PQRCVSL0QW • Deluxe wired remote controller - PQRCUDS0 • Network Soluation(LGAP) • PI 485 - PMNFP14A0 • Simple wired remote controller - PQRCUCS0C • Wired remote controller(for hotel use) - PQRCFCS0C • Wireless LCD remote control - PQWRHDF0(H/P)

Upload: fatjoebird

Post on 27-Jan-2016

222 views

Category:

Documents


0 download

DESCRIPTION

Inverter Cassette Brochure for LG

TRANSCRIPT

Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.

Inverter In-Ceiling Cassette

LG Air Conditioners

Optional (PQWRHDF0) Wireless Remote Controller

PQRCVSL0QW

• Easy to read large font• Large wide LCD• Easy installation

The wired remote controller with a large wide LCD screen featuring large font letters and easy key design enables the user more convenient control of operational conditions of the indoor unit. 2 remote control in 1 indoor unit. Order 1 more wired remote control (PQRCVSL0QW).

New Wired Remote Controller

We at LG are committed to making the lives of our customers more comfortable. Through continuous improvement in R&D and innovation to enhance energy efficiency, LG introduces the new H-Inverter, an energy efficient, quiet unit giving you and your business ultimate comfort.

Life is Good with LG

High Efficiency Inverter

The LG inverter air conditioner comes with a BLDC compressor that uses a strong neodymium magnet. Its compressor thus has improved efficiency compared with the AC inverter.

Powerful BLDC Compressor1

2

4

5

3

Minimized Oil circulation

High Efficiency Motor

Optimize Compression Efficiency

Optimize Vibration, Noise

High Reliability

1

2

3

4

5

With the advancement of inverter technology comes more quiet, economical and powerful air conditioning systems. The LG air conditioner is manufactured using PFC and sine wave technology.

DC Inverter Technology

Step-up Inverter using PFC & Sine Wave Control Technology (PFC : Power Factor Correction)compared to conventional.

Loss

DC 280V

Partial switching Full range Sine wave switching

• PFC Control in Power Input

• Sine wave Control in BLDC Compressor

DC 380V(Boost up)

Full range

Loss

DC 280V

Partial switching Full range Sine wave switching

• PFC Control in Power Input

• Sine wave Control in BLDC Compressor

DC 380V(Boost up)

Full range

• Sine wave Control in BLDC Compressor

• PFC Control in Power Input

The Brushless DC (BLDC) fan motor offers additional energy savings as it is more efficient that an AC motor.The efficiency gain varies with output velocity, at full velocity an energy saving of up to 20% is achieved.

BLDC Fan Technology 100

80

60

40

20

0

200 300 400 500 600 700 800 900 1000

DC motor

AC motor

Approx 20% increase

Approx 40% increase

Effic

ienc

y(%

)

Motor Speed(rpm) BLDC Fan motor

100

80

60

40

20

0

200 300 400 500 600 700 800 900 1000

DC motor

AC motor

Approx 20% increase

Approx 40% increase

Effic

ienc

y(%

)

Motor Speed(rpm) BLDC Fan motor

Night Quiet Operation is a control feature designed to reduce the noise level of the outdoor unit at night. The feature is activated via a dip switch on the outdoor PCB.

* Model UU18WH has the lowest Night Quiet noise level 48dB 39dB

Night Quiet Operation

Noi

se L

evel

[dB

(A)]

Day time Night Quiet

Day timeNight Quiet

UU12WH

UU21WHUU24WH

Noi

s

52

Day t

52 52

UU36WH UU42WH UU48WH

UU12WHUU21WHUU24WH

UU36WH UU42WH UU48WH

time

5255

45

Night

45 44

t Quiet

4447

Noi

se L

evel

[dB

(A)]

Day time Night Quiet

Day timeNight Quiet

UU12WH

UU21WHUU24WH

Noi

s

52

Day t

52 52

UU36WH UU42WH UU48WH

UU12WHUU21WHUU24WH

UU36WH UU42WH UU48WH

time

5255

45

Night

45 44

t Quiet

4447

840x204x840950x25x950

35/33/3152

3.544.04

840x204x840950x25x950

39/37/3448

3.704.07

840v246x840950x25x950

40/38/3652

3.924.22

840v246x840 950x25x950

40/38/3652

3.654.15

840x288x840950x25x950

47/45/4255

3.854.47

840x288x840950x25x950

47/45/4255

3.414.11

840x288x840950x 25x950

47/45/4255

3.233.81

3.5/4.2

5.0/5.5

6.0/7.0

7.0/8.0

10.0/11.2

12.5/14.0

13.4/15.5

UT12QIndoor: UTN12WHOutdoor: UU12WH Front Panel: PT-UMC

UT18QIndoor: UTN18WHOutdoor: UU18WH Front Panel: PT-UMC

UT21QIndoor: UTN21WH Outdoor: UU21WH Front Panel: PT-UMC

UT24QIndoor: UTN24WH Outdoor: UU24WH Front Panel: PT-UMC

UT36QIndoor: UTN36WH Outdoor: UU36WH Front Panel: PT-UMC

UT42QIndoor: UTN42WH Outdoor: UU42WH Front Panel: PT-UMC

UT48QIndoor: UTN48WH Outdoor: UU48WH Front Panel: PT-UMC

Package ModelDimension(mm)

Indoor Unit Decoration Panel

Sound Pressure(dB(A)±3)Indoor(H/M/L)

Outdoor

Capacity(kW)Cooling / HeatingIndoor Unit OutdoorUnit

EER/COP(W/W)Cooling Heating

The LG H-Inverter series has achieved high system efficiency in both Cooling and Heading modes through the use of BLDC Compressor & Fan motors and the use of DC Inverter technology. This has resulted in most models* achieving a heating COP of 4.0

*Except model UT48Q that achieved a COP of 3.81

High Efficiency

LG H-Inverter A Company B Company

*Based on UT36Q.

4.47

3.85 3.963.57 3.76

3.14

CoolingHeating

LG H-Inverter A Company B Company

*Based on UT36Q.

4.47

3.85 3.963.57 3.76

3.14

CoolingHeating

LG H-Inverter A Company B Company

*Based on UT36Q.

4.47

3.85 3.963.57 3.76

3.14

CoolingHeating

Specifications

Set Name UT12Q UT18Q UT21Q UT24Q UT36Q UT42Q UT48QIndoor UTN12WH UTN18WH UTN21WH UTN24WH UTN36WH UTN42WH UTN48WHFront Panel PT-UMC PT-UMC PT-UMC PT-UMC PT-UMC PT-UMC PT-UMCPower Supply Ø/V/Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50

Capacity Cooling kw 1.4 ~ 3.5 ~ 4.2 2.0 ~ 5.0 ~ 5.5 2.8 ~ 6.0 ~ 8.0 2.8 ~ 7.0 ~ 8.4 4.5 ~ 10.0 ~ 13.0 5.0 ~ 12.5 ~ 14.9 5.5 ~ 13.4 ~ 16.0Heating kw 1.6 ~ 4.2 ~ 5.0 2.2 ~ 5.5 ~ 6.05 3.2 ~ 7.0 ~ 9.0 3.2 ~ 8.0 ~ 9.4 4.9 ~ 11.2 ~ 14.0 5.5 ~ 14.0 ~ 16.8 6.4 ~ 15.5 ~ 17.9

Current Nominal running A 0.6 0.6 0.6 0.6 0.72 0.72 0.72

FanMotor Output x Number of Unit 60 x 1 60 x 1 124 x 1 124 x 1 124 x 1 124 x 1 124 x 1

Air Flow Rate(H/M/L)CMM 13/12/10 17/15/13 21/18/16 21/18/16 32/26.1/20.2 32/26.7/21.5 32/27.4/22.8CFM 445/410/340 582/519/459 742/636/565 742/636/565 1130/922/713 1130/943/759 1130/968/805

Coil Coil Row x Column x FPI mm 2Rx8Cx19FPI 2Rx8Cx19FPI 2Rx10Cx19FPI 2Rx10Cx19FPI 2Rx12Cx19FPI/1Rx10Cx19FPI

2Rx12Cx19FPI/1Rx10Cx19FPI

2Rx12Cx19FPI/1Rx10Cx19FPI

Dimensions (WxHxD)

Body mm 840x204x840 840x204x840 840v246x840 840v246x840 840x288x840 840x288x840 840x288x840Decorative Panel mm 950x25x950 950x25x950 950x25x950 950x25x950 950x25x950 950x25x950 950x 25x950

Weight Body kg 21 21 23.5 23.5 28 28 28Decorative Panel kg 5 5 5 5 5 5 5

Sound Level (H/M/L) dB(A)+3 35/33/31 39/37/34 40/38/36 40/38/36 47/45/42 47/45/42 47/45/42

Piping Connections

Liquid(Ø) mm 6.35 6.35 9.52 9.52 9.52 9.52 9.52Gas(Ø) mm 9.52 12.7 15.88 15.88 15.88 15.88 15.88Drain(OD/ID) mm 32/25 32/25 32/25 32/25 32/25 32/25 32/25

Dehumidification Rate l/h 1.3 2.1 2.7 2.7 2.7 3.6 3.6Referigerant R410A R410A R410A R410A R410A R410A R410APower and transmission interunit cable No.*mm² 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75

Outdoor UU12WH UU18WH UU21WH UU24WH UU36WH UU42WH UU48WHRunning Current

Cooling A 4.4 6.0 7.6 9.5 11.5 16.8 18.7Heating A 4.6 6.7 7.7 9.0 11.3 15.0 18.0

Power Supply Ø,V,Hz 1 , 220-240 , 50 1 , 220-240 , 50 1 , 220-240 , 50 1 , 220-240 , 50 1 , 220-240 , 50 1 , 220-240 , 50 1 , 220-240 , 50Power Supply Cable (includes earth) No.*mm² 3 x 2.5 3 x 2.5 3 x 2.5 3 x 2.5 3 x 5.0 3 x 5.0 3 x 5.0Interunit Cable (includes earth) No.*mm² 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75Dimensions W x H x D mm 870x655x320 870x808x320 950x834x330 950v834x330 950 x 1380 x 330 950 x 1380 x 330 950 x 1380 x 330Net Weight kg 46 58 63 63 103 103 103

CompressorOil Charge cc 570 900 900 900 1 300 1 300 1 300Oil Type FVC68D FVC68D FVC68D FVC68D FVC68D FVC68D FVC68D

Refrigerant Cycle Charge(at 5m) g(oz) 1 250(44.16) 2 000(70.6) 2 200(77.6) 2 200(77.6) 3600(127) 3600(127) 3600(127)Additional Refrigerant Charge(over 10m) g/m 20 20 40 40 40 40 40Heat Exchange Tube Size(OD) mm 7.0 7.0 7.0 7.0 7.0 7.0 7.0Fan motor Output kW 0.083 0.124 0.124 0.124 0.124 0.124 0.124Fan Discharge Side/Top Side Discharge Side Discharge Side Discharge Side Discharge Side discharge Side discharge Side dischargeAir Circulation CMM(CFM) 50(1766) 58(2048) 58(2048) 58(2048) 55(1942) x 2 55(1942) x 2 55(1942) x 2

Sound Level

Night quiet Sound Pressure dB(A)±3 45 39 44 44 47 47 47

Sound pressure level dB(A)±3 52 48 52 52 55 55 55

Sound power level at 1.5m dBA±3 66 62 67 67 71 71 71

Piping connection

Liquid(Ø) mm 6.35 6.35 9.52 9.52 9.52 9.52 9.52Gas(Ø) mm 9.52 12.7 15.88 15.88 15.88 15.88 15.88Drain(OD/ID) mm 17/13 17/13 17/13 17/13 17/13 17/13 17/13

Max. Piping Length/Elevation m 30/20 50/30 50/30 50/30 75/30 75/30 75/30Operational Temperature Range

Cooling °CDB -10 ~ 48 -10 ~ 48 -10 ~ 48 -10 ~ 48 -10 ~ 48 -10 ~ 48 -10 ~ 48Heating °CDB -15 ~ 24 -15 ~ 24 -15 ~ 24 -15 ~ 24 -15 ~ 24 -15 ~ 24 -15 ~ 24

AUS-CST1101

New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766PH : 02-8805-4000 FAX : 02-8805-4248

Customer information Centre is available 7AM-7PM on 1300 54 2273 (1300 LG CARE)www.lg.com.au/airconditioning

Western Australia Unit 1/1A 2 Business Way Malaga 6090PO Box 1724 Malaga WA 6944 PH : 08-9249-3721 FAX : 08-9249-1300 Queensland

23 Terrace Place MURARRIE QLD 4172 PH : 07-3908-9000 FAX : 07-3399-4179

New Zealand Unit A, 38 Highbrooke Drive,East Tamaki, 2013 New Zealand PH : +64 (09) 914-2444 FAX : +64 (09) 914-2441

Customer Service Helpline 0800 54 2273 (0800 LG CARE)www.lg.co.nz

South Australia 91 Transport Avenue NETLEY SA 5037 PH : 08-8238-0200 FAX : 08-8238-0299

Victoria 3 John Deere Court, Parkwest Estate DERRIMUT VIC 3030 PH : 03-8369-0900 FAX : 03-9931-0677

Note : • Due to our policy of innovation some specifications may be changed without notification. • Actual cooling & heating capacity will vary as ambient temperature decreases. Please consult your LG sales representative for performance data outside of AS3823.1.2. standard conditions. • Sound level are determined in an anachoic chamber at a distance of 1 m. Actual installed noise levels will vary depending on the installed location. • Information contained in this brochure is a guide only and LG strongly recommends that you ask for advice from specialist installers and retailers, who can assist with measuring rooms and

testing. Specialists can tell you the best size and type of air conditioner suited for your needs.

* Auto changeover is not operable when using the fresh air interlock feature.

Inverter12K

Inverter24K

ARTCOOL24K

ARTCOOL12K 20dB(A)* Inverter12K

Inverter24K

ARTCOOL24K

ARTCOOL12K 20dB(A)* Inverter12K

Inverter24K

ARTCOOL24K

ARTCOOL12K 20dB(A)*

Features• Air supply outlet - 4 • Airflow direction control(up & down) - auto • Auto swing(up & down) • Airflow steps(fan/cool/heat) - 4/5/4 • Chaos wind(auto wind) • Jet cool(Power wind) • Swirl wind • Plasma air purifier - PTPKM0 • Prefilter(washable / anti-fungus) • Drain pump • E.S.P. control • High ceiling operation • Hot start • Self diagnosis • Soft dry operation • Auto changeover • Auto Elevation Grille - PTEGM0 • Auto restart operation • Child lock • Forced operation • Group control • Sleep mode • Timer(on/off) • Timer(weekly) • Two thermistor control • Dry contact - PQDSB • Wide Character wired remote controller, Picto wired remote controller - PQRCVSL0QW • Deluxe wired remote controller - PQRCUDS0 • Network Soluation(LGAP) • PI 485 - PMNFP14A0 • Simple wired remote controller - PQRCUCS0C • Wired remote controller(for hotel use) - PQRCFCS0C • Wireless LCD remote control - PQWRHDF0(H/P)

Inverter In-Ceiling CassetteEasy to Install & Service

LG A I R C O N D I T I O N E R S

One Touch Panel Fitting MethodThe simple push-up panel design easily connects the panel with the body, enabling the installer to use hands freely.

Hanger adjust Drain leakage check

4 Corners Detachable PanelsThe attachable/detachable corner design makes it easy to adjust the hanger during installation and to check for possible leakage in the drain connection pipe.

Right-hand work and parallel piping enhance the convenience of installation.

During installation, a position where there is no gas pipe/liquid pipe interference.

Parallel refrigerant piping and absence of gas pipe / liquid pipe interference makes the pipe connections easier.

Simple Connecting Piping Position and Direction

Reduced size and footprint of outdoor unit will provide a better solution for small offices and shops.

4 way1 way

Inner SVC valve- 4 Way piping is possible. (Front, Rear, Right, Down)- Excellent exterior.

1 2 Convenient Lifting HandleFitted hand grips for easy lifting and installation.

3 Compact Design & Ez SVC- Remove 3 screws for SVC access.- Front panel removal system.

3 screws

Ez SVC

The indoor unit with its slim and compact size enables successful installation in confined spaces.

Slim & Compact sizeModel Size

UTN12WH, UTN18WH 204mm

UTN21WH, UTN24WH 246mm

UTN36WH, UTN42WH, UTN48WH

288mm5 kW Model

204mm245mm

ConventionalLG

All vane operation Individual vane operation Individual vane angle control

Direct air flow Indirect air flow

Vane angle control satisfies both users who like direct air or indirect wind and it also reduces cold air drafts.

4 Vane Indepedent Operation

Milestone1 9 5 8 1 9 6 8 1 9 8 5 1 9 9 0 1 9 9 5 1 9 9 8 2000 2 0 0 1 2002 2004 2008 2009

Company foundedManufactured Korea’s first air conditionerIntroduced Korea’s first inverter air conditionerProduced rotary compressorChanged company name to LG Electronics Produced scroll compressorProduced Korea’s first commercial air conditionerBecame world’s number one seller of residential air conditionersIntroduced the world’s first picture frame air conditionerLaunched the LG Home Net Brand of integrated home networking solutionAchieved world’s highest annual sales in air conditioners with 10 million unitsReached total global sales of 100 million air conditionersAC Company created as part of LG Electronics’ business reorganization

Improved wide vanes reduce dead bands and provide better air and temperature distribution.

Wide Jet Air Flow

27°C

15°C

t262524232221201918

27°C

15°C

t262524232221201918

New Cassette

Current

Even air distribution

Air flow dead zonein 4 corners

567mm

487mm

80mm Wider!Using this kit, a duct can be fitted to increase the intake of outdoor air.

Fresh air intake kit (Option)

Case.1 Case.2 Case.3

Existing type Ceiling pollution prevention type

Ceilingpollutions

Ceiling

Louver Louver

Product Product CeilingThe new outlet design can reduce ceiling contamination from air currents flowing along the ceiling.

Design to Reduce Ceiling Stains

Normal air flow Swirl Swing (pleasant air)

Swirl swing distributes air evenly throughout the room to ensure a more comfortable conditioned environment by adjusting the movement of the louvres.

Swirl Swing

Group ControlThe optional Group Control can link and control up to 16 indoor units from one control device.

You can set on/off programing options on your air conditioning system for a period of one week.

• 24-Hour ON/ OFF Timer in 1 hour intervals • TEST RUN Mode • Self-Diagnosis function • 3-Step Fan Speed selection • Operation Indication • Room Temperature Display • Only 20mm thick

Weekly Programing

One motor per vane is adopted to control each of the four vanes independently, freely controlling air currents according to requirements.

Independent Automatic Vane Control

0 : 30˚

2 : 40˚3 : 50˚

4 : 60˚5 : 70˚

BLDC Motor

High Efficiency turbo fan

Variable range of air of the interior fan motor

- Improved outlet & airflow design.- Removal of unnecessary noise through the high efficiency turbo fan. - Resonance noise removal by anti vibration design & BLDC motor.

BLDC motor, Low indoor noise with high efficiency turbo fan.

Improved Low Noise

New CassetteCurrentDepending on the height of the installation,

LG air conditioners allow you to vary the speed of the indoor fan motor. When installation is low, the RPM can be reduced but it can be increased when the installation is high to ensure optimum comfort levels. The speed can be adjusted via the slide switch on the back of the LCD wired remote.

High Ceiling OperationWhen cooling rooms in the event of low outdoor temperatures, the BLDC inverter compressor and outdoor BLDC fan motor are used to adjust the air flow and volume, with a view to ensuring efficient operation by allowing the air conditioner to keep operating at -10°C without turning it off.

Wide Operating Range

Indo

or T

emp

(˚C

)

Outdoor Temp(˚C)

16

18

30

32

-15 -10 24 48

Cooling

Heating

Low AmbientControl